• 제목/요약/키워드: Rotating Facility

검색결과 52건 처리시간 0.022초

Pulsar observation with KVN

  • Kim, Chunglee;Dodson, Richard;Jung, Taehyun;Sohn, Bong Won
    • 천문학회보
    • /
    • 제39권1호
    • /
    • pp.52.1-52.1
    • /
    • 2014
  • Radio pulsars are highly magnetized, rapidly rotating neutron stars that emit synchrotron radiation along the magnetic axes at their spin frequencies. Traditionally, pulsar observations have been done at low frequencies (MHz up to a few GHz), since radio pulsar spectrum is known to a power-law with a steep negative spectral index. More recently, high-frequency pulsar observations (several GHz and above) have been made as a broadband spectrometer and fast computers became available. High-frequency pulsar observations will provide information on radio emission mechanism of pulsars in the vicinity of the neutron star surface. There is also huge interest from gravitational-wave and astrophysics community to find a pulsar in the center of our Galaxy. The Korean VLBI Network has three 21-m single dishes in the Korean peninsula. Using KVN's lowest observational frequency of 22-GHz, we performed test observations with the KVN targeting a few selected known, bright pulsars. In addition, we have been developing pulsar pipelines that can be utilized with a VLBI facility using Mark-V. We present a brief introduction of radio pulsars and show data obtained with the KVN.

  • PDF

블레이드 표면거칠기에 따른 터빈 성능저하 (Turbine Performance Degradation Due to Blade Surface Roughness)

  • 박일영;윤용일;송성진
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2003년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.92-98
    • /
    • 2003
  • Turbine blades experience significant surface degradation with service. This paper presents experimental evidence of blade surface roughness reducing turbine efficiency. Performance tests were conducted in a low speed, single-stage axial flow turbine rig with roughened blade surfaces. Sheets of sandpaper with equivalent sandgrain roughnesses of 106 and $400{\mu}m$ were used to roughen the blades. In these tests, effects of roughened stator vanes and rotor blades were separately evaluated. In the fully rough regime ($k_{s}=400{\mu}m$), the experimental results show an 11 percent decrease in normalized efficiency with roughness only on stator vanes ; an 8 percent decrease with roughness only on rotor blades ; and a 19 percent decrease with roughness on both the stator and rotor blades. In the transitionally rough regime ($k_{s}=106{\mu}m$), the trends are similar approximately 4 percent decrease with either roughened stator or roughened rotor and an 8 percent decrease with roughness on both stator and rotor blades. Thus, roughened stator vanes incur more performance penalty than roughened rotor blades.

  • PDF

스팀터빈의 공력성능 평가를 위한 공기 상사실험 (Air Similarity Test for the Evaluation of Aerodynamic Performance of Steam Turbine)

  • 임병준;이은석;양수석;이익형;김영상;권기범
    • 한국유체기계학회 논문집
    • /
    • 제7권5호
    • /
    • pp.29-35
    • /
    • 2004
  • The turbine efficiency is an important factor in power plant, and accurate evaluation of steam turbine performance is the key issue in turbo machinery industry. The difficulty of evaluating the steam turbine performance due to its high steam temperature and pressure environment makes the most steam turbine tests to be replaced by air similarity test. This paper presents how to decide the similarity conditions of the steam turbine test and describes its limitations and assumptions. The test facility was developed and arranged to conduct an air similarity turbine performance test with various inlet pressure, temperature and mass flow rate. The eddy-current type dynamometer measures the turbine-generated shaft power and controls the rotating speed. Pressure ratio of turbine can be controled by back pressure control valve. To verify its test results, uncertainty analysis was performed and relative uncertainty of turbine efficiency was obtained.

가스터빈 슬링거 연소기 실험연구 (An Experimental Study of the Gas Turbine Slinger Combustor)

  • 최성만;이강엽;이동훈;박정배
    • 한국항공우주학회지
    • /
    • 제34권2호
    • /
    • pp.68-74
    • /
    • 2006
  • 가스터빈 슬링거 연소기의 연소특성을 연구하기 위한 실험적 연구를 수행하였다. 연소실험을 위한 시험리그를 제작하여 한국항공우주연구원의 연소시험설비에 설치하였다. 점화성능 시험결과 점화한계에 영향을 주는 두개의 중요한 인자를 발견할 수 있었다. 첫 번째는 연료노즐의 회전수이고, 두 번째는 질량유량이다. 좋은 점화성능을 가지기 위해서는 연료노즐의 회전속도와 공기유량을 증가시킴으로서 가능하다. 연소성능 시험결과 연소효율은 99.6%, 패턴 팩터는 15%, 프로파일 팩터는 3%로 측정 되었다. 연구결과 슬링거 연소기의 점화와 연소특성은 기존의 환형 연소기에 비하여 상당한 차이점을 가지고 있음을 알 수 있었다.

Registration-free 3D Point Cloud Data Acquisition Technique for as-is BIM Generation Using Rotating Flat Mirrors

  • Li, Fangxin;Kim, Min-Koo;Li, Heng
    • 국제학술발표논문집
    • /
    • The 8th International Conference on Construction Engineering and Project Management
    • /
    • pp.3-12
    • /
    • 2020
  • Nowadays, as-is BIM generation has been popularly adopted in the architecture, engineering, construction and facility management (AEC/FM) industries. In order to generate a 3D as-is BIM of a structural component, current methods require a registration process that merges different sets of point cloud data obtained from multiple locations, which is time-consuming and registration error-prone. To tackle this limitation, this study proposes a registration-free 3D point cloud data acquisition technique for as-is BIM generation. In this study, small-size mirrors that rotate in both horizontal and vertical direction are used to enable the registration-free data acquisition technique. First, a geometric model that defines the relationship among the mirrors, the laser scanner and the target component is developed. Second, determinations of optimal laser scanner location and mirror location are performed based on the developed geometrical model. To validate the proposed registration-free as-is BIM generation technique, simulation tests are conducted on key construction components including a PC slab and a structural wall. The result demonstrates that the registration-free point cloud data acquisition technique can be applicable in various construction elements including PC elements and structural components for as-is BIM generation.

  • PDF

소형 송풍기 소음의 음향학적 상사성에 관한 연구 (Acoustical Similarity for Small Cooling Fans Revisited)

  • 김용철;진성훈;이승배
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1995년도 춘계학술대회논문집; 전남대학교, 19 May 1995
    • /
    • pp.196-201
    • /
    • 1995
  • The broadband and discrete sources of sound in small cooling fans of propeller type and centrifugal type were investigated to understand the turbulent vortex structures from many bladed fans using ANSI test plenum for small air-moving devices (AMDs). The noise measurement method uses the plenum as a test apparatus to determine the acoustic source spectral density function at each operating conditions similar to real engineering applications based on acoustic similarity laws. The characteristics of fans including the head rise vs. volumetric flow rate performance were measured using a performance test facility. The sound power spectrum is decomposed into two non-dimensional functions: an acoustic source spectral distribution function F(St,.phi.) and an acoustic system response function G(He,.phi.) where St, He, and .phi. are the Strouhal number, the Helmholtz number, and the volumetric flow rate coefficient, respectively. The autospectra of radiated noise measurements for the fan operating at several volumetric flow rates,.phi., are analyzed using acoustical similarity. The rotating stall in the small propeller fan with a bell-mouth guided is mainly due to a leading edge separation. It creates a blockage in the passage and the reduction in the flow rate. The sound power levels with respect to the rotational speeds were measured to reveal the mechanisms of stall and/or surge for different loading conditions and geometries, for example, fans installed with a impinging plate. Lee and Meecham (1993) studied the effect of the large-scale motions like impinging normally on a flat plate using Large-Eddy Simulation(LES) and Lighthill's analogy.[ASME Winter Annual Meeting 1993, 93-WA/NCA-22]. The dipole and quadrupole sources in the fans tested are shown closely related to the vortex structures involved using cross-correlations of the hot-wire and microphone signals.

  • PDF

Flow-accelerated corrosion assessment for SA106 and SA335 pipes with elbows and welds

  • Kim, Dong-Jin;Kim, Sung-Woo;Lee, Jong Yeon;Kim, Kyung Mo;Oh, Se Beom;Lee, Gyeong Geun;Kim, Jongbeom;Hwang, Seong-Sik;Choi, Min Jae;Lim, Yun Soo;Cho, Sung Hwan;Kim, Hong Pyo
    • Nuclear Engineering and Technology
    • /
    • 제53권9호
    • /
    • pp.3003-3011
    • /
    • 2021
  • A FAC (flow-accelerated corrosion) test was performed for a straight pipe composed of the SA335 Gr P22 and SA106 Gr B (SA106-SA335-SA106) types of steel with welds as a function of the flow rate in the range of 7-12 m/s at 150 ℃ and with DO < 5 ppb at pH levels ranging from 7 to 9.5 up to a cumulative test time of 7200 h using the FAC demonstration test facility. Afterward, the experimental pipe was examined destructively to investigate opposite effects as well as entrance effects. In addition, the FAC rate obtained using a pipe specimen with a 50 mm inner diameter was compared with the rate obtained from a rotating cylindrical electrode. The effects of the complicated fluid flows at the elbow and orifice of the pipeline were also evaluated using another test section designed to examine the independent effects of the orifice and the elbow depending on the distance and the combined effects on orifice and elbow. The tests were performed under the following conditions: 130-150 ℃, DO < 5 ppb, pH 7 and a flow rate of 3 m/s. The FAC rate was determined using the thickness change obtained from commercial room-temperature ultrasonic testing (UT).

메탈부쉬 누락예방을 위한 데이터마이닝 기법의 적용 및 비교 (Application and Comparison of Data Mining Technique to Prevent Metal-Bush Omission)

  • 고상현;이동주
    • 산업경영시스템학회지
    • /
    • 제46권3호
    • /
    • pp.139-147
    • /
    • 2023
  • The metal bush assembling process is a process of inserting and compressing a metal bush that serves to reduce the occurrence of noise and stable compression in the rotating section. In the metal bush assembly process, the head diameter defect and placement defect of the metal bush occur due to metal bush omission, non-pressing, and poor press-fitting. Among these causes of defects, it is intended to prevent defects due to omission of the metal bush by using signals from sensors attached to the facility. In particular, a metal bush omission is predicted through various data mining techniques using left load cell value, right load cell value, current, and voltage as independent variables. In the case of metal bush omission defect, it is difficult to get defect data, resulting in data imbalance. Data imbalance refers to a case where there is a large difference in the number of data belonging to each class, which can be a problem when performing classification prediction. In order to solve the problem caused by data imbalance, oversampling and composite sampling techniques were applied in this study. In addition, simulated annealing was applied for optimization of parameters related to sampling and hyper-parameters of data mining techniques used for bush omission prediction. In this study, the metal bush omission was predicted using the actual data of M manufacturing company, and the classification performance was examined. All applied techniques showed excellent results, and in particular, the proposed methods, the method of mixing Random Forest and SA, and the method of mixing MLP and SA, showed better results.

배관내 압력변동 신호를 이용한 유량 추정 방법 연구 (A Study on Flow Rate Estimation Using Pressure Fluctuation Signals in Pipe)

  • 이정한;장대식;박진호
    • 한국압력기기공학회 논문집
    • /
    • 제19권2호
    • /
    • pp.155-162
    • /
    • 2023
  • In nuclear power plants, the flow rate information is a major indicator of the performance of rotating equipment such as pumps, and is a very important one required for facility operation and maintenance. To measure a flow rate, various types of methods have been developed and used. Among them, the differential pressure type using orifice and the direct doppler type using ultrasonic waves are the most commonly used. However, these flow rate measurement methods have limitations in installation, conditions and status of the measuring part, etc. To solve this problem, we have studied a new technique for measuring flow rate from scratch. In this paper, we have devised a technique to estimate the flow rate using an average moving velocity of large-scale eddy in turbulence that occurs in the piping flow field. The velocity of the large-scale eddy can be measured using the pressure fluctuation signals on the inner surface of the pipe. To estimate the flow rate, at first a cross-correlation function is applied to the two pressure fluctuation signals located at different positions in the down stream for calculating the time delay between the moving eddies. In order to validate the proposed flow rate estimation method, CFD analyses for the internal turbulence flow in pipe are conducted with a fixed flow condition, where the pressure fluctuation signals on the pipe inner surface are simulated. And then the average flow velocity of the large scale eddy is to be estimated. The estimated flow velocity is turned out to be similar to the fixed (known) flow rate.

추락 및 투신자살 방지시스템의 조사 및 Rollinder System 적용기술 (Evaluation of Prevention System of Falls and Committing Suicide with Application Technology of Rollinder System)

  • 박세만;백충현;최병정
    • 한국산학기술학회논문지
    • /
    • 제20권5호
    • /
    • pp.591-598
    • /
    • 2019
  • 대한민국은 심각한 자살시도에 휘말려 2003년 이후 지금까지 OECD 회원국 가운데 자살률 통계에 있어 상위권을 차지하고 있으며, 전년 대비 -5.0% 소폭하락 했지만 여전히 사망 요인 중 10세 이상 전 연령에서 자살이 가장 높으며, 이것은 반드시 해결해야 할 매우 중요한 사안들이다. 자살 수단별 사망률의 변화추이를 살펴보면 추락 및 투신을 통한 자살이 큰 비중을 차지하고 있으며, 국내뿐만 아니라 해외에서도 이에 대한 근본적인 대책마련이 없어 쉽게 해결할 수 없는 심각한 문제로 대두되고 있다. 대표적인 예로 미국의 금문교에 최근 2억 달러를 들여 자살방지 그물망을 설치하고 있으며, 뉴질랜드의 경우 교량에 철망을 철거했다가 치솟은 자살률로 인해 디자인을 바꿔 다시 설치했으며, 캐나다와 호주의 경우도 교량에 철책을 둘러쌓아 교량의 미관을 포기한 채 투신자살만을 방지하고 있다. 따라서 본 논문은 국내 외의 자살방지 시스템과 관련된 특허기술에 대한 비교평가를 제안하고, 보안시설 및 제한구역에서의 접근차단, 특수시설에서의 월담방지와 추락 및 투신자살을 효과적으로 방지하기 위한 기계적 기술적 시스템인 롤린더 시스템을 제시하고자 한다. 마창대교는 롤린더 시스템 설치 전인 2016년 까지 8년간 33명이 자살시도를 하였으나, 2017년 롤린더 시스템 설치 후에는 자살시도의 획기적인 감축효과를 거두었다.