• Title/Summary/Keyword: Root mean square (RMS)

Search Result 495, Processing Time 0.026 seconds

Analysis of Muscle Activity of the Scapular Rotators With Changes of Shoulder Abduction Angle in Both Erect and Slouched Trunk Position (척주 기립자세와 굽힌자세에서 어깨관절 외전각도 변화에 따른 어깨뼈 주위 근 활성도 분석)

  • Kim, Duck-Hwa;Choi, Jong-Duk;Oh, Jae-Seop
    • Physical Therapy Korea
    • /
    • v.11 no.1
    • /
    • pp.45-52
    • /
    • 2004
  • Altered scapular kinematics in the scapular joint is commonly believed to be a factor contributing to trunk posture. The purpose of this study was to analyze the muscle activity with several changes of the shoulder angle. Tests were performed on 10 male subjects by repeated measures. Each subject was measured while sitting in both erect and slouched trunk positions. In each sitting posture, a three-dimensional motion analysis measurement was used to measure thoracic angle and shoulder abduction angle. Measurements were taken with the shoulder abdcution angle at $0^{\circ}$, $30^{\circ}$, $60^{\circ}$, $90^{\circ}$, $120^{\circ}$, and $150^{\circ}$. By using surface Electromyography (EMG) electrodes, we recorded the activity of the upper trapezius, middle trapezius, lower trapezius, middle deltoid, and serratus anterior muscle while the subject held a 4 kg weight at each angle. The mean of root mean square (RMS) of EMG activity was calculated. The middle trapezius, lower trapezius, and middle deltoid muscle activity showed significantly higher results but serratus anterior muscle activity showed significantly lower results (p<.05). With the shoulder angle increased, the muscle activity was also significantly increased (p<.05). In conclusion, the thoracic spine posture significantly affects the scapular muscle during scapular plane abduction, and the slouched posture is associated with increased trapezius muscle activity and with decreased serratus anterior muscle activity.

  • PDF

Feature Extraction and Evaluation for Classification Models of Injurious Falls Based on Surface Electromyography

  • Lim, Kitaek;Choi, Woochol Joseph
    • Physical Therapy Korea
    • /
    • v.28 no.2
    • /
    • pp.123-131
    • /
    • 2021
  • Background: Only 2% of falls in older adults result in serious injuries (i.e., hip fracture). Therefore, it is important to differentiate injurious versus non-injurious falls, which is critical to develop effective interventions for injury prevention. Objects: The purpose of this study was to a. extract the best features of surface electromyography (sEMG) for classification of injurious falls, and b. find a best model provided by data mining techniques using the extracted features. Methods: Twenty young adults self-initiated falls and landed sideways. Falling trials were consisted of three initial fall directions (forward, sideways, or backward) and three knee positions at the time of hip impact (the impacting-side knee contacted the other knee ("knee together") or the mat ("knee on mat"), or neither the other knee nor the mat was contacted by the impacting-side knee ("free knee"). Falls involved "backward initial fall direction" or "free knee" were defined as "injurious falls" as suggested from previous studies. Nine features were extracted from sEMG signals of four hip muscles during a fall, including integral of absolute value (IAV), Wilson amplitude (WAMP), zero crossing (ZC), number of turns (NT), mean of amplitude (MA), root mean square (RMS), average amplitude change (AAC), difference absolute standard deviation value (DASDV). The decision tree and support vector machine (SVM) were used to classify the injurious falls. Results: For the initial fall direction, accuracy of the best model (SVM with a DASDV) was 48%. For the knee position, accuracy of the best model (SVM with an AAC) was 49%. Furthermore, there was no model that has sensitivity and specificity of 80% or greater. Conclusion: Our results suggest that the classification model built upon the sEMG features of the four hip muscles are not effective to classify injurious falls. Future studies should consider other data mining techniques with different muscles.

Evaluation of the usefulness of IGRT(Image Guided Radiation Therapy) for markerless patients using SGPS(Surface-Guided Patient Setup) (표면유도환자셋업(Surface-Guided Patient Setup, SGPS)을 활용한 Markerless환자의 영상유도방사선치료(Image Guided Radiation Therapy, IGRT)시 유용성 평가)

  • Lee, Kyeong-jae;Lee, Eung-man;Lee, Jeong-su;Kim, Da-yeon;Ko, Hyeon-jun;Choi, Shin-cheol
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.33
    • /
    • pp.109-116
    • /
    • 2021
  • Purpose: The purpose of this study is to evaluate the usefulness of Surface-Guided Patient Setup by comparing the patient positioning accuracy when image-guided radiation therapy was used for Markerless patients(unmarked on the skin) using Surface-Guided Patient Setup and Marker patients(marked on the skin) using Laser-Based Patient Setup. Materials And Methods: The position error during IGRT was compared between a Markerless patient initially set up with SGPS using an optical surface scanning system using three cameras and a Marker patient initially set up with LBPS that aligns the laser with the marker drawn on the patient's skin. Both SGPS and LBPS were performed on 20 prostate cancer patients and 10 Stereotactic Radiation Surgery patients, respectively, and SGPS was performed on an additional 60 breast cancer patients. All were performed IGRT using CBCT or OBI. Position error of 6 degrees of freedom was obtained using Auto-Matching System, and comparison and analysis were performed using Offline-Review in the treatment planning system. Result: The difference between the root mean square (RMS) of SGPS and LBPS in prostate cancer patients was Vrt -0.02cm, Log -0.02cm, Lat 0.01cm, Pit -0.01°, Rol -0.01°, Rtn -0.01°, SRS patients was Vrt 0.02cm, Log -0.05cm, Lat 0.00cm, Pit -0.30°, Rol -0.15°, Rtn -0.33°. there was no significant difference between the two regions. According to the IGRT standard of breast cancer patients, RMS was Vrt 0.26, Log 0.21, Lat 0.15, Pit 0.81, Rol 0.49, Rtn 0.59. Conclusion:. As a result of this study, the position error value of SGPS compared to LBPS did not show a significant difference between prostate cancer patients and SRS patients. In the case of additionally performed SGPS breast cancer patients, the position error value was not large based on IGRT. Therefore, it is considered that it will be useful to replace LBPS with SGPS, which has the great advantage of not requiring patient skin marking..

Orbit Determination of High-Earth-Orbit Satellites by Satellite Laser Ranging

  • Oh, Hyungjik;Park, Eunseo;Lim, Hyung-Chul;Lee, Sang-Ryool;Choi, Jae-Dong;Park, Chandeok
    • Journal of Astronomy and Space Sciences
    • /
    • v.34 no.4
    • /
    • pp.271-280
    • /
    • 2017
  • This study presents the application of satellite laser ranging (SLR) to orbit determination (OD) of high-Earth-orbit (HEO) satellites. Two HEO satellites are considered: the Quasi-Zenith Satellite-1 (QZS-1), a Japanese elliptical-inclinedgeosynchronous-orbit (EIGSO) satellite, and the Compass-G1, a Chinese geostationary-orbit (GEO) satellite. One week of normal point (NP) data were collected for each satellite to perform the OD based on the batch least-square process. Five SLR tracking stations successfully obtained 374 NPs for QZS-1 in eight days, whereas only two ground tracking stations could track Compass-G1, yielding 68 NPs in ten days. Two types of station bias estimation and a station data weighting strategy were utilized for the OD of QZS-1. The post-fit root-mean-square (RMS) residuals of the two week-long arcs were 11.98 cm and 10.77 cm when estimating the biases once in an arc (MBIAS). These residuals were decreased significantly to 2.40 cm and 3.60 cm by estimating the biases every pass (PBIAS). Then, the resultant OD precision was evaluated by the orbit overlap method, yielding three-dimensional errors of 55.013 m with MBIAS and 1.962 m with PBIAS for the overlap period of six days. For the OD of Compass-G1, no station weighting strategy was applied, and only MBIAS was utilized due to the lack of NPs. The post-fit RMS residuals of OD were 8.81 cm and 12.00 cm with 49 NPs and 47 NPs, respectively, and the corresponding threedimensional orbit overlap error for four days was 160.564 m. These results indicate that the amount of SLR tracking data is critical for obtaining precise OD of HEO satellites using SLR because additional parameters, such as station bias, are available for estimation with sufficient tracking data. Furthermore, the stand-alone SLR-based orbit solution is consistently attainable for HEO satellites if a target satellite is continuously trackable for a specific period.

Improvement of Capturing Velocity in the Fume Hood using Computational Fluid Dynamics(I) - Uniform flow (전산유체역학을 이용한 흄후드 제어유속 개선(I) - 균일류)

  • Jung, Jong-Hyeon;Lee, Sang-Woon;Lee, Sang-Man;Shon, Byung-Hyun;Lee, Jung-Hee;Jung, Yu-Jin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.2
    • /
    • pp.962-969
    • /
    • 2013
  • This study used Computational Fluid Dynamics(CFD) to assess the properties of the air current inflow and the flow velocity distribution in the fume hood. In order to verify the effect of improvement, it was also predicted the characteristics of the flow pattern in case the hood face is structurally improved. The assessment of the capture velocity with the existing fume hood confirmed maximum 23 to 30% difference as compared to the root mean square (RMS). And the hood face showed great difference in flow velocity, with the flow velocity in the upper part is 58 to 68% faster than that in the lower part of the hood. So, as a result of the improvement of the hood designed to maintain a steady exhaust at the hood face (that is, installing a baffle on the inner wall and designing the slot type face), a difference of maximum 7% as compared to RMS appeared while maximum 12% differentiation in flow velocity through sections was predicted, showing mitigation of much of the difference in control velocity as compared to the previous structure.

Optimized DSP Implementation of Audio Decoders for Digital Multimedia Broadcasting (디지털 방송용 오디오 디코더의 DSP 최적화 구현)

  • Park, Nam-In;Cho, Choong-Sang;Kim, Hong-Kook
    • Journal of Broadcast Engineering
    • /
    • v.13 no.4
    • /
    • pp.452-462
    • /
    • 2008
  • In this paper, we address issues associated with the real-time implementation of the MPEG-1/2 Layer-II (or MUSICAM) and MPEG-4 ER-BSAC decoders for Digital Multimedia Broadcasting (DMB) on TMS320C64x+ that is a fixed-point DSP processor with a clock speed of 330 MHz. To achieve the real-time requirement, they should be optimized in different steps as follows. First of all, a C-code level optimization is performed by sharing the memory, adjusting data types, and unrolling loops. Next, an algorithm level optimization is carried out such as the reconfiguration of bitstream reading, the modification of synthesis filtering, and the rearrangement of the window coefficients for synthesis filtering. In addition, the C-code of a synthesis filtering module of the MPEG-1/2 Layer-II decoder is rewritten by using the linear assembly programming technique. This is because the synthesis filtering module requires the most processing time among all processing modules of the decoder. In order to show how the real-time implementation works, we obtain the percentage of the processing time for decoding and calculate a RMS value between the decoded audio signals by the reference MPEG decoder and its DSP version implemented in this paper. As a result, it is shown that the percentages of the processing time for the MPEG-1/2 Layer-II and MPEG-4 ER-BSAC decoders occupy less than 3% and 11% of the DSP clock cycles, respectively, and the RMS values of the MPEG-1/2 Layer-II and MPEG-4 ER-BSAC decoders implemented in this paper all satisfy the criterion of -77.01 dB which is defined by the MPEG standards.

Quantitative Evaluation of Image Quality using Automatic Exposure Control (AEC 사용 유무에 따른 영상의 화질평가)

  • Kim, Gwang-ho;Yoo, Gwan-ju;Kang, Ji-won;Ko, Bong-joo;Kim, Kyoun-lan;Kim, Min-hee;Yoon, Young-woo;Ye, Soo-young;Choi, Seok-yoon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.10a
    • /
    • pp.86-89
    • /
    • 2015
  • Quantitative Evaluation of Image Quality using Automatic Exposure Control This it leads, the relationship of control and image between of photographing condition, DR proper use method proposing. Chest phantom acquires Chest PA images which it follows in conditional change, Image evaluation factor (SNR (Signal to Noise Ratio), CNR (Contrast to Noise Ratio), PSNR (Peak Signal to Ratio), RMS (Root Mean Square)). It excepted RMS price, SNR, CNR, PSNR the case which uses AEC it came out being high The fact that the quality of image is better there was a case which does not use AEC. but Price it was slight. Image qualitative it was deficient in AEC use presence. Through this, the overall situation and most efficient use of radiation workers is better suited. But Passive AEC use would be appropriate for use rather than proactive AEC.

  • PDF

Assembly and Testing of a Visible and Near-infrared Spectrometer with a Shack-Hartmann Wavefront Sensor (샤크-하트만 센서를 이용한 가시광 및 근적외선 분광기 조립 및 평가)

  • Hwang, Sung Lyoung;Lee, Jun Ho;Jeong, Do Hwan;Hong, Jin Suk;Kim, Young Soo;Kim, Yeon Soo;Kim, Hyun Sook
    • Korean Journal of Optics and Photonics
    • /
    • v.28 no.3
    • /
    • pp.108-115
    • /
    • 2017
  • We report the assembly procedure and performance evaluation of a visible and near-infrared spectrometer in the wavelength region of 400-900 nm, which is later to be combined with fore-optics (a telescope) to form a f/2.5 imaging spectrometer with a field of view of ${\pm}7.68^{\circ}$. The detector at the final image plane is a $640{\times}480$ charge-coupled device with a $24{\mu}m$ pixel size. The spectrometer is in an Offner relay configuration consisting of two concentric, spherical mirrors, the secondary of which is replaced by a convex grating mirror. A double-pass test method with an interferometer is often applied in the assembly process of precision optics, but was excluded from our study due to a large residual wavefront error (WFE) in optical design of 210 nm ($0.35{\lambda}$ at 600 nm) root-mean-square (RMS). This results in a single-path test method with a Shack-Hartmann sensor. The final assembly was tested to have a RMS WFE increase of less than 90 nm over the entire field of view, a keystone of 0.08 pixels, a smile of 1.13 pixels and a spectral resolution of 4.32 nm. During the procedure, we confirmed the validity of using a Shack-Hartmann wavefront sensor to monitor alignment in the assembly of an Offner-like spectrometer.

Comparison of Muscle Activity During a Push-up on a Suspension Sling and a Fixed Support (슬링(sling)과 고정된 지지면에서의 팔굽혀펴기 동작 시 근 활성도 비교)

  • Oh, Jae-Seop;Park, Jun-Sang;Kim, Suhn-Yeop;Kwon, Oh-Yun
    • Physical Therapy Korea
    • /
    • v.10 no.3
    • /
    • pp.29-40
    • /
    • 2003
  • The purpose of this study was to compare the muscle activity during a push-up on a suspension sling and a fixed support at the same level. Tests were performed on 15 male subjects. Electromyography using a surface EMG recorded the activity of the triceps, pectoralis major, and internal and external oblique muscles during each push-up. EMG activity was recorded at 0, 45, and 90 degrees of elbow flexion in the push-up position on a suspension sling or a fixed support at the same height above the floor (30 cm). The testing order was selected randomly. The subjects were asked to maintain the push-up position with straight knees, hips, and trunk for 5 seconds at each elbow angle. The mean root mean square (RMS) of EMG activity was calculated. EMG activity was normalized using the maximum voluntary isometric contractιn elicited using a manual muscle testing technique. Two-factor repeated measures analysis of variance (ANOVA) was used to compare the average RMS value of EMG activity for each condition. The EMG activity for the pectoralis major, and internal and external oblique muscles during a push-up on a sling was significantly higher than on a fixed support at all angles of elbow flexion (p<.01). There were significant differences in the EMG activity of the pectoralis major and triceps brachii muscles at difference angles of elbow flexion (p<.05). The pectoralis major muscle had the highest EMG activity at 90 degrees of elbow flexion on both the sling and fixed support. The triceps brachii muscle had the highest EMG activity at 45 degrees of elbow flexion on both the sling and fixed support. The internal and external oblique muscles had the highest EMG activity at 0 degrees of elbow flexion, although the difference with angle of flexion was not significant. These results suggest that to improve proximal and trunk stability and muscle strength, push-ups are more useful when performed on a suspension sling than On a fixed support.

  • PDF

Probability Distribution of Nonlinear Random Wave Heights Using Maximum Entropy Method (최대 엔트로피 방법을 이용한 비선형 불규칙 파고의 확률분포함수)

  • 안경모
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.10 no.4
    • /
    • pp.204-210
    • /
    • 1998
  • This paper presents the development of the probability density function applicable for wave heights (peak-to-trough excursions) in finite water depth including shallow water depth. The probability distribution applicable to wave heights of a non-Gaussian random process is derived based on the concept of the maximum entropy method. When wave heights are limited by breaking wave heights (or water depth) and only first and second moments of wave heights are given, the probability density function developed is closed form and expressed in terms of wave parameters such as $H_m$(mean wave height), $H_{rms}$(root-mean-square wave height), $H_b$(breaking wave height). When higher than third moment of wave heights are given, it is necessary to solve the system of nonlinear integral equations numerically using Newton-Raphson method to obtain the parameters of probability density function which is maximizing the entropy function. The probability density function thusly derived agrees very well with the histogram of wave heights in finite water depth obtained during storm. The probability density function of wave heights developed using maximum entropy method appears to be useful in estimating extreme values and statistical properties of wave heights for the design of coastal structures.

  • PDF