• Title/Summary/Keyword: Root mean square (RMS)

Search Result 495, Processing Time 0.03 seconds

The Effects of the Jean Patterns on Muscle Activity of the Lower Limbs during Walking (청바지의 패턴이 보행 시 하지 근 활동에 미치는 영향)

  • Song, Young-Eun;Chu, Mi-Seon
    • Fashion & Textile Research Journal
    • /
    • v.11 no.6
    • /
    • pp.911-917
    • /
    • 2009
  • The purpose of this study was to investigate muscle activity of the lower limbs when walking in jeans in order to obtain basic information for development of new jeans patterns with excellent movement adaptability. Using three types of jeans (basic, medium, and slim) with different ease on hip, knee circumference, and crotch length, and two different types of shoes, Electromyogram (EMG) of the lower limbs muscle was measured for four healthy subjects walking on treadmills and stairs. EMG of vastus lateralis, semitendinous, tibialis anterior and medial head of gastrocnemius muscles was measured. The muscle activity was assessed in RMS (Root Mean Square) value of the EMG. On the treadmill in sneakers, only the vastus lateralis muscle showed a significant difference in RMS value depending on patterns. Basic and medium jeans allowed higher muscle activity than trunks of slim jeans did. On the treadmill in high heels and slim jeans, the RMS values of all muscles were significantly smaller than in basic jeans, whereas no significant differences were shown while in trunks or medium jeans. On the stairs either in sneakers or in high heels, no significant differences were shown between all muscle activities for all types of jeans. On the treadmill, greater fatigue was induced in all muscles from walking in high heels than in sneakers for all jeans patterns. When walking on the stairs wearing either type of shoes, however, the effect of jeans pattern on muscle activities was different from muscle to muscle.

Optical Clock Recovery from RZ and NRZ data using a Multi-Section Laser Diode with a DFB Reflector (DFB 반사기가 집적된 다중전극 레이저 다이오드를 이용한 RZ 및 NRZ 데이터 신호의 광클럭 재생)

  • Jeon, Min-Yong;Leem, Young-Ahn;Kim, Dong-Churl;Sim, Eun-Deok;Kim, Sung-Bock;Park, Kyung-Hyun;Yee, Dae-Su
    • Korean Journal of Optics and Photonics
    • /
    • v.17 no.1
    • /
    • pp.68-74
    • /
    • 2006
  • We have extracted an optical clock signal from a return-to-zero(RZ) pseudorandom bit sequence(PRBS) and non-return-to-zero(NRZ) PRBS data in a pulsation multi-section laser diode with DFB reflector. The ms timing jitter achieved less than 1 ps for the input 11.727 Gbit/s RZ PRBS and NRZ PRBS data. The PRE data wasconverted from the NRZ data using an NRZ to pseudo-return to zero(PRZ) converter module. The optical clock was extracted from the PRZ data which contains the clock components. Although the input PRZ data gives a timing jitter of 2 ps, the extracted clock has timing jitter of ${\~}$1 ps.

Trueness and precision of scanning abutment impressions and stone models according to dental CAD/CAM evaluation standards

  • Jeon, Jin-Hun;Hwang, Seong-Sig;Kim, Ji-Hwan;Kim, Woong-Chul
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.5
    • /
    • pp.335-339
    • /
    • 2018
  • PURPOSE. The purpose of the present study was to compare scanning trueness and precision between an abutment impression and a stone model according to dental computer-aided design/computer-aided manufacturing (CAD/CAM) evaluation standards. MATERIALS AND METHODS. To evaluate trueness, the abutment impression and stone model were scanned to obtain the first 3-dimensional (3-D) stereolithography (STL) file. Next, the abutment impression or stone model was removed from the scanner and re-fixed on the table; scanning was then repeated so that 11 files were obtained for each scan type. To evaluate precision, the abutment impression or stone model was scanned to obtain the first 3-D STL file. Without moving it, scanning was performed 10 more times, so that 11 files were obtained for each scan type. By superimposing the first scanned STL file onto the other STL files one by one, 10 color-difference maps and reports were obtained; i.e., 10 experimental scans per type. The independent t-test was used to compare root mean square (RMS) data between the groups (${\alpha}=.05$). RESULTS. The $RMS{\pm}SD$ values of scanning trueness of the abutment impression and stone model were $22.4{\pm}4.4$ and $17.4{\pm}3.5{\mu}m$, respectively (P<.012). The $RMS{\pm}SD$ values of scanning precision of the abutment impression and stone model were $16.4{\pm}2.9$ and $14.6{\pm}1.6{\mu}m$, respectively (P=.108). CONCLUSION. There was a significant difference in scanning trueness between the abutment impression and stone model, as evaluated according to dental CAD/CAM standards. However, all scans showed high trueness and precision.

The Effects of Changing the Respiratory Muscles and Acoustic Parameters on the Children With Spastic Cerebral Palsy (체간 조절을 통한 앉기 자세 교정이 경직형 뇌성마비 아동들의 호흡근과 음향학적 측정치들의 변화에 미치는 효과)

  • Kim, Sun-Hee;Ahn, Jong-Bok;Seo, Hye-Jung;Kwon, Do-Ha
    • Physical Therapy Korea
    • /
    • v.16 no.2
    • /
    • pp.16-23
    • /
    • 2009
  • The purpose of this study was to investigate the effects postural changes on respiratory muscles and acoustic parameters of the children with spastic cerebral palsy. Nine children with spastic cerebral palsy who required assistance when walking were selected. The ages of the children ranged from 6 to 9 years old. The phonation of the sustained vowel /a/ and the voice qualities of each child such as fundamental frequency($F_0$; Hz), pitch variation (Jitter; %), amplitude variation (Shimmer; %) and noise to harmonic ratio (NHR) were analyzed by Multi-Dimensional Voice Program (MDVP). The muscle activity of three major respiratory muscles: pectoralis major muscle, upper trapezius muscle and rectus abdorminalis muscle, were measured by examining the root mean square (RMS) of the surface EMG to investigate the impact of changes in the adjusted sitting posture of each subject. However, the RMS of pectoralis major muscle showed a significant differences (p<.05). Secondly, there were no significant differences in $F_0$, Jitter and Shimmer between pre and post posture change, but there was a significant difference in NHR (p<.05). The data were collected in each individual; once prior and once after the sitting posture change. The data were analyzed by Wilcoxon signed ranks-test using SPSS version 14.0 for Windows. The findings of this study were as follows; Firstly, the RMS of upper trapezius and rectus abdorminalis muscle were not significant different between pre and post sitting posture changes. From the result, it is concluded that changes in the adjusted sitting posture decreases the abnormal respiratory patterns in the children with spastic cerebral palsy which is characterized by the hyperactivity of the respiratory muscles in breathing. Also, there is increased on the voice qualities in children with spastic cerebral palsy.

  • PDF

Precise Measurement Method and Error Analysis with Roughness Variables for Estimation of Scattering Coefficients (지표면 산란 계수 예측을 위한 정확한 지표면 거칠기 변수 측정 방법 및 오차 분석)

  • Kweon, Soon-Koo;Hwang, Ji-Hwan;Oh, Yisok;Hong, Sungwook
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.1
    • /
    • pp.91-97
    • /
    • 2013
  • The input parameters of scattering models for computing the backscattering coefficients of earth terrains are mainly soil moisture and surface roughness. The backscattering coefficients of soil surfaces are more sensitive to surface roughness than soil moisture. In this study, we propose a precise measurement method for roughness parameters and analyze measurement errors. We measured surface roughness using a pin-board profiler(1 m, 0.5 cm interval) and a laser profiler(1 m, 0.25 cm interval). The measurement differences between two profilers in an average sense are 0.097 cm for root-mean-square (RMS) height and 1.828 cm for correlation length. The analysis of the correlation functions and relative errors shows that the laser measurements are more stable than the pin-board measurements. The differences of the calculated backscattering coefficients using a surface scattering model between pin-board and laser profiler measurements are less than 1 dB.

Interfacial Adhesion Properties of Surface Treated Polyarylate Fiber with Polyethylene Naphthalate (폴리아릴레이트 섬유의 표면처리에 의한 폴리에틸렌 나프탈레이트 수지와의 계면접착특성)

  • Yong, Da Kyung;Choi, Han Na;Yang, Ji Woo;Lee, Seung Goo
    • Journal of Adhesion and Interface
    • /
    • v.13 no.1
    • /
    • pp.24-30
    • /
    • 2012
  • Morphological changes of polyarylate (PAR) fiber treated with formic acid and ultraviolet (UV) were observed by using a scanning electron microscope (SEM) and an atomic force microscope (AFM). The results were analysed by using root mean square (RMS) roughness. In addition, the chemical changes of surface was investigated using contact angle and the interfacial adhesive strength between PAR fiber and PEN (Polyethylene naphthalate) matrix was calculated using the Pull-out test results. As the acid treatment concentration and UV irradiation time increased, cracks and pores were produced on the PAR fiber surface. Due to the roughness increased, the contact angle was decreased. For this reason, RMS roughness of PAR fiber was increased and the interfacial adhesive strength between the PAR fiber and PEN matrix was improved. The increase of interfacial adhesive strength was responsible for the increase of surface area which have cracks and pores.

High Frequency Signal Analysis of Oxidizer Pump for 7-tonf Turbopump (7톤급 터보펌프 산화제펌프의 고주파 신호 분석)

  • Bae, Joon-Hwan;Choi, Chang-Ho;Choi, Jong-Soo
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.24 no.6
    • /
    • pp.61-68
    • /
    • 2020
  • 7-tonf turbopump real-propellant tests in Naro Space Center were conducted and high-frequency signals from an accelerometer and pressure sensors installed on the casing and the inlet/outlet pipeline of LOX pump were analyzed to estimate the structural and hydrodynamic stabilities. Waterfalls, frequency spectrums and RMS(Root Mean Square) values of the measured signals were calculated and characteristic instability frequencies by the rotating cavitation and the rear floating ring seal(F.R.S) were investigated. Static pressures of the inlet/outlet pipeline and an acceleration of the pump casing are strongly affected on pressure fluctuation induced by the rear floating ring seal in the leakage path. Despite the acceleration RMS value seems totally small, the rotating-speed-related synchronous frequency affecting the shaft instability is distinctly observed in the frequency contour.

The Effect of Modified Swing Method on the Muscle Activation Patterns of Upper Limb in Wheelchair Badminton Players

  • You Joo SHIN;Duk Chan JANG;Sangbum PARK
    • Journal of Sport and Applied Science
    • /
    • v.7 no.2
    • /
    • pp.1-12
    • /
    • 2023
  • Purpose: The purpose of this study was to investigate the possibility of modified swing to prevent shoulder injury by analyzing differences in the muscle activation patterns of upper limb by the swing method in wheelchair badminton players. Research design, data, and methodology: 10 wheelchair badminton players participated in the experiment as subjects and performed 10 high clears and 10 smashes in both traditional and modified swing methods toward a shuttlecock hung at the height of racket impact point. For each trial, activation patterns of biceps brachii, triceps brachii, anterior deltoid, and posterior deltoid were measured from the upper limb participating in the swing from which the duration, peak, and root mean square (RMS) of electromyography (EMG) activities from swing initiation to shuttle impact were calculated. The maximum swing velocity of the smash and the distance of the high clear were also measured with both methods to compare differences in the swing velocity and shuttle hit distance. Results: Differences in the EMG peak and RMS of the anterior deltoid by swing methods were shown to differ by the skill type, being higher in the traditional swing method than the modified during only the high clear. The EMG peak and RMS, and the duration of the posterior deltoid were higher and longer with the traditional swing method than the modified during both the smash and high clear. The intensities of the biceps brachii and triceps brachii activities measured during the smash and high clear were higher in the traditional swing method than the modified, and the biceps brachii and triceps activity durations during the high clear were shorter in the modified swing method than the traditional. The maximum swing velocity of the smash was faster with the traditional swing method than the modified, while the distance of the high clear did not differ significantly. Conclusions: These results suggest that the modified swing can be an effective performance method for preventing shoulder injuries without undue loss of impact power in wheelchair badminton players by reducing excessive loads imposed on the shoulder and allowing the optimal use of the elbow extension.

Effect of build orientation on the accuracy and internal porosity of removable partial denture metal frameworks (적층 빌드 방향이 가철성 국소의치 금속 구조물의 정확도와 내부 다공성에 미치는 영향)

  • Geon Hee Ham;Ji-Hwan Kim
    • Journal of Technologic Dentistry
    • /
    • v.46 no.3
    • /
    • pp.73-83
    • /
    • 2024
  • Purpose: This study aimed to investigate whether the accuracy and internal porosity of removable partial denture frameworks differ depending on the build direction in the selective laser melting method. Methods: A partially edentulous maxillary study model was scanned, and the anterior-posterior palatal bar was then digitally designed. The angles formed between the z-axis and the path of the insertion and removal were divided into five groups: -60°, -30°, 0°, 30°, and 60°. For each group, three removable partial denture metal frameworks were fabricated and used as specimens. The inner surface of each sample was scanned and superimposed on the design file to obtain the root mean square (RMS) value, and the average RMS value of each group was measured. One sample was randomly selected from each group, and the equivalent diameter and sphericity of the pores were analyzed using industrial X-ray three-dimensional computed tomography. To compare statistical differences between groups, the Kruskal-Wallis test of SPSS Statistics ver. 27.0 (IBM) was used (α=0.05). Results: The average RMS values of the whole inner surface accuracy of the specimens were in the order of -60°<0°<-30°<30°<60° (p<0.05). The equivalent diameter and sphericity of internal pores were significantly different among groups (p<0.001). Conclusion: The build orientation of the selective laser melting method influences the accuracy and internal porosity of removable partial denture frameworks.

Precise Orbit Determination of GRACE-A Satellite with Kinematic GPS PPP

  • Choi, Byung-Kyu;Roh, Kyoung-Min;Yoo, Sung-Moon;Jo, Jung-Hyun;Lee, Sang-Jeong
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.1 no.1
    • /
    • pp.59-64
    • /
    • 2012
  • Precise Point Positioning (PPP) has been widely used in navigation and orbit determination applications as we can obtain precise Global Positioning System (GPS) satellite orbit and clock products. Kinematic PPP, which is based on the GPS measurements only from the spaceborne GPS receiver, has some advantages for a simple precise orbit determination (POD). In this study, we developed kinematic PPP technique to estimate the orbits of GRACE-A satellite. The comparison of the mean position between the JPL's orbit product and our results showed the orbit differences 0.18 cm, 0.54 cm, and 0.98 cm in the Radial, in Along-track, and Cross-track direction respectively. In addition, we obtained the root mean square (rms) values of 4.06 cm, 3.90 cm, and 3.23 cm in the satellite coordinate components relative to the known coordinates.