• 제목/요약/키워드: Root filling material

검색결과 82건 처리시간 0.02초

Gutta percha 충전시 도말층 유무에 따른 근관벽과의 접합도에 관한 주사전자현미경적 연구 (A SCANNING ELECTRON MICROSCOPIC STUDY ON THE ADAPTATION OF ROOT CANAL FILLING MATERIAL TO ROOT CANAL WALL WITH AND WITHOUT SMEAR LAYER)

  • 문주훈;조영곤
    • Restorative Dentistry and Endodontics
    • /
    • 제17권2호
    • /
    • pp.365-382
    • /
    • 1992
  • The purpose of this study was to evaluate the adaptation of filling material to the dentinal walls of root canals with and without smear layer. Fifty extracted upper and lower anterior teeth were selected, and the root canals were instrumented with K - files 1mm short of the apical foramen by step - back method. The teeth were randomly divided into two groups of 25 each : in the group I, smear layers were not removed, and in the group II, smear layers were removed by 15% EDTA solution. Again the two groups 25 teeth were randomly divided into unfilled contol group and filling groups(lateral, ultrasonic, ULTRAFIL, McSpadden compaction group). Upon completion of root canal filling, the teeth were grooved on the both the labial and lingual surfaces and then split with mallet and chisel. Each specimens were examined with JSM - 840 Scanning Electron Microscope (JEOL., Japan). The results were as follows : 1. In the contol group, dentinal tubules of group I couldn't be distinguished in the canal wall, but those of group II appeared to be open and patent. 2. In the filling groups of group I, the tubular penetration of the sealer or gutta percha couldn't be seen, but in the filling groups of group II, it could be seen except McSpadden compaction group. 3. In the filling groups, ULTRAFIL group showed the best adaptation of filling material to root canal wall among the group I, and lateral and ultrasonic condensation group showed the best adaptation of filling material among the group II. McSpadden compaction group showed the worst adaptation in group I, II. 4. Generally, the group II showed better adapation of filling material to root canal wall than the group I.

  • PDF

A micro-computed tomographic study of remaining filling materials of two bioceramic sealers and epoxy resin sealer after retreatment

  • Kim, KyungJae;Kim, Da Vin;Kim, Sin-Young;Yang, SungEun
    • Restorative Dentistry and Endodontics
    • /
    • 제44권2호
    • /
    • pp.18.1-18.9
    • /
    • 2019
  • Objective: This study evaluated the presence of residual root canal filling material after retreatment using micro-computed tomography (micro-CT). Materials and Methods: Extracted human teeth (single- and double-rooted, n = 21/each; C-shaped, n = 15) were prepared with ProFile and randomly assigned to three subgroups for obturation with gutta-percha and three different sealers (EndoSeal MTA, EndoSequence BC sealer, and AH Plus). After 10 days, the filling material was removed and the root canals were instrumented one size up from the previous master apical file size. The teeth were scanned using micro-CT before and after retreatment. The percentage of remaining filling material after retreatment was calculated at the coronal, middle, and apical thirds. Data were analyzed using the Kruskal-Wallis test and Mann-Whitney U test with Bonferroni post hoc correction. Results: The tested sealers showed no significant differences in the percentage of remaining filling material in single- and double-rooted teeth, although EndoSeal MTA showed the highest value in C-shaped roots (p < 0.05). The percentage of remaining filling material of AH Plus and EndoSeal MTA was significantly higher in C-shaped roots than in single- or double-roots (p < 0.05), while that of BC sealer was similar across all root types. EndoSeal MTA showed the highest values at the apical thirds of single- and double-roots (p < 0.05); otherwise, no significant differences were observed among the coronal, middle, and apical thirds. Conclusions: Within the limitations of this study, a large amount of EndoSeal MTA remained after retreatment, especially in C-shaped root canals.

Biocompatibility of root-end filling materials: recent update

  • Saxena, Payal;Gupta, Saurabh Kumar;Newaskar, Vilas
    • Restorative Dentistry and Endodontics
    • /
    • 제38권3호
    • /
    • pp.119-127
    • /
    • 2013
  • The purpose of a root-end filling is to establish a seal between the root canal space and the periradicular tissues. As root-end filling materials come into contact with periradicular tissues, knowledge of the tissue response is crucial. Almost every available dental restorative material has been suggested as the root-end material of choice at a certain point in the past. This literature review on root-end filling materials will evaluate and comparatively analyse the biocompatibility and tissue response to these products, with primary focus on newly introduced materials.

Effects of four novel root-end filling materials on the viability of periodontal ligament fibroblasts

  • Akbulut, Makbule Bilge;Arpaci, Pembegul Uyar;Eldeniz, Ayce Unverdi
    • Restorative Dentistry and Endodontics
    • /
    • 제43권3호
    • /
    • pp.24.1-24.12
    • /
    • 2018
  • Objectives: The aim of this in vitro study was to evaluate the biocompatibility of newly proposed root-end filling materials, Biodentine, Micro-Mega mineral trioxide aggregate (MM-MTA), polymethylmethacrylate (PMMA) bone cement, and Smart Dentin Replacement (SDR), in comparison with contemporary root-end filling materials, intermediate restorative material (IRM), Dyract compomer, ProRoot MTA (PMTA), and Vitrebond, using human periodontal ligament (hPDL) fibroblasts. Materials and Methods: Ten discs from each material were fabricated in sterile Teflon molds and 24-hour eluates were obtained from each root-end filling material in cell culture media after 1- or 3-day setting. hPDL fibroblasts were plated at a density of $5{\times}10^3/well$, and were incubated for 24 hours with 1:1, 1:2, 1:4, and 1:8 dilutions of eluates. Cell viability was evaluated by XTT assay. Data was statistically analysed. Apoptotic/necrotic activity of PDL cells exposed to material eluates was established by flow cytometry. Results: The Vitrebond and IRM were significantly more cytotoxic than the other root-end filling materials (p < 0.05). Those cells exposed to the Biodentine and Dyract compomer eluates showed the highest survival rates (p < 0.05), while the PMTA, MM-MTA, SDR, and PMMA groups exhibited similar cell viabilities. Three-day samples were more cytotoxic than 1-day samples (p < 0.05). Eluates from the cements at 1:1 dilution were significantly more cytotoxic (p < 0.05). Vitrebond induced cell necrosis as indicated by flow cytometry. Conclusions: This in vitro study demonstrated that Biodentine and Compomer were more biocompatible than the other root-end filling materials. Vitrebond eluate caused necrotic cell death.

초음파 근관기구를 이용한 근관충전법의 근관폐쇄능에 관한 주사 전자현미경적 연구 (A SCANNING ELECTRON MICROSCOPIC EVALUATION OF THE ROOT CANAL FILLING WITH ULTRASONIC ENDODONTIC INSTRUMENT)

  • 최라영;이인숙
    • Restorative Dentistry and Endodontics
    • /
    • 제15권2호
    • /
    • pp.104-114
    • /
    • 1990
  • The purpose of this study was to evaluate the adaptation of root canal filling material to the dentinal wall of root canal and to compare the sealing ability of the root canal filling materials using ultrasonic endodontic instrument with injection-molded thermoplasticized gutta-percha filling method and lateral condensation method. Fifty fresh human single root exlracted for orthodontic treatment, were randomly selected, and instrumented by step-back technique. And then, the teeth were divided into 5 groups according to each root canal filling methods. In the experimental group 1 and group 2, the root canals were filled with gutta perdia cases using ultrasonic instrument with and without sealer. In the experimental group 3 and 4, using jection-moldeed thermoplasticized gutta-percha method by obtul$^{(R)}$ canals were filled with and without sealer. In the control group, the canals were filled with sealer by lateral candensation. And then, 5 teeth of each group were immersed in black Indian ink, decalcified and cleared. The depth of dye penetration into the root canal were evaluated with stereoscope (Reichert Ltd., USA). Among the 5 teeth remaining in each group, the single longituding grooves were made on the labial and lingual root surfaces and then immersed in the liquid nitrogen to fracture the teeth spontaneously without any distortions of gutta-percha. Each specimens were examined with X-650 Scanning Electron Microscope(Hitachi ltd, Japan) to show the adaptation to the canal wall, void, homogenicity of filling material and location of gutta-percha or sealer in the dentinal tubules of the root canal. The observations were as follows : 1. The experimental group 1 showed smaller mean dye penetration than control group, and showed the penetraton of sealer in the dentinal tubules of apical third of the root canal. 2. The experimental group 2 and group 4 showed the penetration of gutta-percha in the dentinal tubules of root canals. 3. The experimental group 1 and group 3 showed less mean dye penetration than the experimental group 2 and group 4. 4. The experimental group 1 and group 2 showed better adaptation of filling materials than control group.

  • PDF

수종의 치근단역충전 재료가 MG63 osteoblast-like cells에 미치는 영향 (THE EFFECT OF SEVERAL ROOT-END FILLING MATERIALS ON MG63 OSTEOBLAST-LIKE CELLS)

  • 이정호;손원준;이원철;백성호
    • Restorative Dentistry and Endodontics
    • /
    • 제35권3호
    • /
    • pp.222-228
    • /
    • 2010
  • 본 연구의 목적은 현재 치근단 역충전재로 널리 사용되고 있는 MTA와 새롭게 개발된 제품인 DB를 MG63 세포를 사용하여 비교하는 것이다. 치근단 역충전재료로는 MTA, DB, IRM을 사용하였고 대조군으로는 tissue culture plastic을 사용하였다. 각 재료를 혼합하고 혼합물의 경화가 일어나도록 24시간 동안 놓아두었다. MG63 세포를 각 군에 뿌려준 후 세포가 재료에 부착될 수 있도록 4시간 배양하였다. 치근단 역충전재를 세포에 접촉시킨 후 세포수준의 초기 반응을 관찰하였다. 12시간 더 배양한 후 세포가 각 재료에 붙어 있는 정도를 관찰하고, 각 재료가 골형성에 미치는 영향을 알아보기 위해 ELISA를 이용하여 $TGF{\beta}1$, OC를 측정하였고 ALP의 양도 측정하였다. 결과는 일원배치분산분석법으로 통계처리하였다. 그 결과, 재료에 부착이 일어난 세포의 수 항목과 OC 항목에서만 MTA와 DB간에 통계적으로 차이가 없었다. 다른 항목들에서는 모든 군 간에 통계적으로 유의한 차이가 있었다. DB가 MTA와 완전히 같은 세포반응을 보이지는 않았지만 부착이 일어난 세포의 수는 재료의 생체적합성을 나타내며 OC는 골형성 정도를 나타내므로 DB가 역충전 재료로 사용된다면 MTA와 유사한 결과를 보일 것으로 예측된다.

Effectiveness and safety of rotary and reciprocating kinematics for retreatment of curved root canals: a systematic review of in vitro studies

  • Lucas Pinho Simoes;Alexandre Henrique dos Reis-Prado;Carlos Roberto Emerenciano Bueno;Ana Cecília Diniz Viana ;Marco Antonio Hungaro Duarte ;Luciano Tavares Angelo Cintra;Cleidiel Aparecido Araujo Lemos;Francine Benetti
    • Restorative Dentistry and Endodontics
    • /
    • 제47권2호
    • /
    • pp.22.1-22.18
    • /
    • 2022
  • Objectives: This systematic review (register-osf.io/wg7ba) compared the efficacy and safety of rotary and reciprocating kinematics in the removal of filling material from curved root canals. Materials and Methods: Only in vitro studies evaluating both kinematics during retreatment were included. A systematic search (PubMed/MEDLINE, Scopus, and other databases, until January 2021), data extraction, and risk of bias analysis (Joanna Briggs Institute checklist) were performed. Efficacy in filling removal was the primary outcome. Results: The search resulted in 2,795 studies, of which 15 were included. Efficacy was measured in terms of the remaining filling material and the time required for this. Nine studies evaluated filling material removal, of which 7 found no significant differences between rotary and reciprocating kinematics. Regarding the time for filling removal, 5 studies showed no difference between both kinematics, 2 studies showed faster results with rotary systems, and other 2 showed the opposite. No significant differences were found in apical transportation, centering ability, instrument failure, dentin removed and extruded debris. A low risk of bias was observed. Conclusions: This review suggests that the choice of rotary or reciprocating kinematics does not influence the efficacy of filling removal from curved root canals. Further studies are needed to compare the kinematics safety in curved root canals.

만곡된 근관에서 Gutta-Percha 제거 시 스테인리스스틸 수기구와 회전식 NiTi 재치료용 기구의 효과 비교 (A Comparison of the Effectiveness of Stainless-Steel Hand Instrument and Rotary NiTi Retreatment Instrument to Remove Gutta-Percha in Curved Root Canals)

  • 남동구;김민정;조혜진;이광원;유미경
    • 구강회복응용과학지
    • /
    • 제27권1호
    • /
    • pp.99-107
    • /
    • 2011
  • 비외과적 재근관치료의 주된 목표는 치근주변의 치유를 위하여 근관 공간을 완전히 멸균하는 것이며, 이 목표를 달성하기 위해서는 이전 충전물질의 완전한 제거가 요구된다. 전통적으로 근관충전물질의 제거는 스테인리스스틸 수기구를 통해서 이루어져 왔으며 이는 시간과 노력이 많이 소요되는 작업이다. 최근 보다 효율적인 근관충전물질의 제거를 위해 재치료용 회전식 NiTi 기구가 소개되었다. 이 연구에서는 만곡된 근관에서의 스테인리스스틸 수기구, ProTaper Universal Retreatment (Dentsply Maillefer, Ballaigues, Switzerland), Mtwo retreatment (Sweden & Martina, Padova, Italy)의 gutta-percha 제거 효율을 비교하였다. 재치료 후 근관 내 남겨진 gutta-percha의 양은 실험군 사이에 유의한 차이가 발견되지 않았다. 하지만 재치료에 소요된 시간은 재치료용 회전식 NiTi 기구를 이용한 실험군에서 더 적게 소요되는 것으로 나타났다.

Impact of root canal curvature and instrument type on the amount of extruded debris during retreatment

  • Burcu Serefoglu;Gozde Kandemir Demirci;Seniha Micoogullari Kurt;Ilknur Kasikci Bilgi;Mehmet Kemal Caliskan
    • Restorative Dentistry and Endodontics
    • /
    • 제46권1호
    • /
    • pp.5.1-5.13
    • /
    • 2021
  • Objectives: The aim of the current study was to assess whether the amount of extruded debris differs for straight and severely curved root canals during retreatment using H-files, R-Endo, Reciproc and ProTaper Universal Retreatment (PTU-R) files. Additionally, the area of residual filling material was evaluated. Materials and Methods: Severely curved (n = 104) and straight (n = 104) root canals of maxillary molar teeth were prepared with WaveOne Primary file and obturated with gutta-percha and AH Plus sealer. Root canal filling materials were removed with one of the preparation techniques: group 1: H-file; group 2: R-Endo; group 3: Reciproc; group 4: PTU-R (n = 26). The amount of extruded material and the area of the residual filling material was measured. The data were analyzed with 2-way analysis of variance (ANOVA) and 1-way ANOVA at the 0.05 significance level. Results: Except for Reciproc group (p > 0.05), PTU-R, R-Endo, and H-file systems extruded significantly more debris in severely curved canals (p < 0.05). Each file system caused more residual filling material in severely curved canals than in straight ones (p < 0.05). Conclusions: All instruments used in this study caused apical debris extrusion. Root canal curvature had an effect on extruded debris, except for Reciproc system. Clinicians should be aware that the difficult morphology of the severely curved root canals is a factor increasing the amount of extruded debris during the retreatment procedure.

Enhancing the Physicochemical Properties of Sodium Iodide-based Root Canal Filling Material with Lanolin Incorporation

  • Hye Shin Park;Jongsoo Kim;Joonhaeng Lee;Jisun Shin;Mi Ran Han;Jongbin Kim;Yujin Kim;Junghwan Lee
    • 대한소아치과학회지
    • /
    • 제51권2호
    • /
    • pp.140-148
    • /
    • 2024
  • This study aimed to enhance the physicochemical properties of sodium iodide-based root filling materials, particularly solubility. In earlier developmental stages, the iodoform-containing paste exhibited high antibacterial efficacy but failed to meet only the solubility requirement among the ISO 6876 criteria. Therefore, this study focused on enhancing the physicochemical properties of the paste under development, particularly centering on reducing its solubility. Four experimental groups were established, including three control group. The previously developed D30 paste was named the Oil 33 group, and the control group was named the Vitapex® group. The Oil 50 group, in which the oil content was increased, and the Oil 45L group, in which lanolin was incorporated. The physical properties (solubility, pH, flowability, and film thickness) of the four pastes were evaluated according to the ISO 6876 standards. No significant differences were observed between the Oil 45L and Vitapex® groups in any of the physical property evaluations. While the Oil 33 and Oil 50 groups met the ISO 6876 standards for flowability and film thickness, the Oil 45L group met all the physical properties. However, reducing the overall oil content may be necessary to enhance the antimicrobial properties. The result of the physicochemical experiments showed that the Oil 45L group with the newly formulated composition and incorporated lanolin exhibited low solubility meeting the ISO 6876 standard of ≤ 3%. We were able to develop a paste with more stable solubility than previous iodide-based root-filling materials. Therefore, the oil content must be further adjusted to improve its antimicrobial properties. If other physical properties also meet the ISO 6876 standards and demonstrate excellent results in cytotoxicity tests, this root filling material could potentially replace existing options.