• Title/Summary/Keyword: Room impulse response

Search Result 38, Processing Time 0.023 seconds

Analysis of Infrared Wireless Indoor Communication Link with a Source on the Wall (벽면에 광소스가 위치하는 경우의 실내 무선 광링크 분석)

  • Ji, Yun-Gyu
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.37 no.2
    • /
    • pp.46-54
    • /
    • 2000
  • Because the installation of the optical cables in rooms is difficult, we can terminate the optical cable at the main enterence and use infrared wireless communications in the room. In this paper, we calculate the impulse response of the infrared wireless communication link and the optical power penalty due to multipath effect up to the third reflections with the source on the sidewall. We can locate the optical sources on the sidewall without problem because of relative large power reflected from the ceiling and sidewalls once. And the optical power penalty due to multipath effect can be neglected at the speed of 2 Mb/s.

  • PDF

Sound Externalization using Multichannel Room Impulse Response (멀티채널 룸임펄스 응답 기반 외재화 알고리즘)

  • Jang, In-Seon;Lee, Yong-Ju;Jang, Dae-Young;Kang, Kyeong-Ok
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2008.02a
    • /
    • pp.139-142
    • /
    • 2008
  • 헤드폰 또는 이어폰으로 오디오 청취 시 흔히 음상이 머리 내부에 맺히는 현상이 발생하게 되며, 이러한 현상을 음상 내재화(Inside Head Localization; IHL)라 한다. 오디오의 음상이 머리 주변 혹은 머리 내부에 맺히게 되면 공간감이나 입체감이 떨어지게 되어 음향의 현실감을 저하시키게 되며 또한 청취에 따른 피로도가 증가하게 된다. 이러한 음상 내재화 현상을 제거하여, 헤드폰/이어폰을 통해 오디오 청취 시 음상이 머리의 외부에 맺히도록(Out of Head Localization; OHL) 하는 기술을 음상 외재화(Sound Externalization) 기술이라 한다. 룸 임펄스 응답이 방향 큐와 연계하여 생성되었을 경우 외재화가 가능하다는 실험적 사실을 바탕으로 기존의 음상 외재화 방법은 일반적인 HRTF (Head Related Transfer Function)를 이용하여 외재화 필터를 구성해왔다. 본 논문에서는 구체마이크로폰을 이용하여 녹음한 멀티채널 룸 임펄스 응답을 기반으로 모델링 된 외재화 필터를 이용한 음원 외재화 방법을 제안한다. 또한 실험 및 결과 분석을 통하여 본 알고리즘의 전방 음원 외재화 성능의 우수성을 입증하고, 외재화 알고리즘 적용 후의원 신호 음상 보존 성능을 확인한다.

  • PDF

Functional Gene Analysis to Identify Potential Markers Induced by Benzene in Two Different Cell Lines, HepG2 and HL-60

  • Kim, Youn-Jung;Song, Mi-Kyung;Sarma, Sailendra Nath;Choi, Han-Saem;Ryu, Jae-Chun
    • Molecular & Cellular Toxicology
    • /
    • v.4 no.3
    • /
    • pp.183-191
    • /
    • 2008
  • Volatile organic compounds (VOCs) are common constituents of cleaning and degreasing agents, paints, pesticides, personal care products, gasoline and solvents. And VOCs are evaporated at room temperature and most of them exhibit acute and chronic toxicity to human. Benzene is the most widely used prototypical VOC and the toxic mechanisms of them are still unclear. The multi-step process of toxic mechanism can be more fully understood by characterizing gene expression changes induced in cells by toxicants. In this study, DNA microarray was used to monitor the expression levels of genes in HepG2 cells and HL-60 cells exposed to the benzene on IC20 and IC50 dose respectively. In the clustering analysis of gene expression profiles, although clusters of HepG2 and HL-60 cells by benzene were divided differently, expression pattern of many genes observed similarly. We identified 916 up-regulated genes and 1,144 down-regulated genes in HepG2 cells and also 1,002 up-regulated genes and 919 down-regulated genes in HL-60 cells. The gene ontology analysis on genes expressed by benzene in HepG2 and HL-60 cells, respectively, was performed. Thus, we found some principal pathways, such as, focal adhesion, gap junction and signaling pathway in HepG2 cells and toll-like receptor signaling pathway, MAPK signaling pathway, p53 signaling pathway and neuroactive ligand-receptor interaction in HL-60 cells. And we also found 16 up-regulated and 14 down-regulated commonly expressed total 30 genes that belong in the same biological process like inflammatory response, cell cycle arrest, cell migration, transmission of nerve impulse and cell motility in two cell lines. In conclusion, we suggest that this study is meaningful because these genes regarded as strong potential biomarkers of benzene independent of cell type.

Echo Canceller with Improved Performance in Noisy Environments (잡음에 강인한 반향 제거기 연구)

  • 이세원;박호종
    • The Journal of the Acoustical Society of Korea
    • /
    • v.22 no.4
    • /
    • pp.261-268
    • /
    • 2003
  • Conventional acoustic echo cancellers using ES algorithm have simple structure and fast convergence speed compared with those using NLMS algorithm, but they are very weak to external noise because ES algorithm updates the adaptive filter taps based on average energy reduction rate of room impulse response in specific acoustical condition. To solve this problem, in this paper, a new update algorithm for acoustic echo canceller with stepsize matrix generator is proposed. A set of stepsizes is determined based on residual error energy which is estimated by two moving average operators, and applied to the echo canceller in matrix from, resulting in improved convergence speed. Simulations in various noise condition show that the proposed algorithm improves the robustness of acoustic echo canceller to external noise.

Comparison of IIR Filter and Wavelet Filter on Acoustic Decay Measurements (음 감쇠 측정에서의 IIR 필터와 웨이블렛 필터의 영향에 대한 수치 계산, 비교)

  • 이상권;이민성;김봉기
    • The Journal of the Acoustical Society of Korea
    • /
    • v.20 no.5
    • /
    • pp.5-13
    • /
    • 2001
  • It is well known that there are two experimental errors on acoustic decay measurements. ,One is due to the influence of the band pass filter the other one is that of an averaging device. In this paper the influence of the filter is investigated in detail. To minimize the influence of the filter, the product of the filter bandwidth B (3dB bandwidth) and the reverberation time T/sub 60/ of the room under test should be at least 16. Moreover, if the initial part of an acoustic decay curve is important, the strong requirement, i. e. BT/sub 60/〉64, must be satisfied. In this paper, the wavelet filter bank instead of the band pass filter bank is applied to obtain an acoustic decay curve. As a result, the influence of filter is reduced and then the value of BT/sub 60/ required for obtaining an acceptable decay curve becomes at least 4. The strong requirement for the initial part of a decay curve is also replaced by the BT/sub 60/〉16 instead of BT/sub 60/〉64.

  • PDF

Effectiveness of Monetary Policy in Korea Due to Time Varying Monetary Policy Stance (거시경제 및 통화정책 기조 변화가 통화정책의 유효성에 미친 영향 분석)

  • Kim, Tae Bong
    • KDI Journal of Economic Policy
    • /
    • v.36 no.3
    • /
    • pp.1-23
    • /
    • 2014
  • This paper has studied the monetary policy in Korea with a time varying VAR model using four key macroeconomic variables. First, inclusion of the exchange rate was a crucial factor in evaluating Korean monetary policy since the monetary policy demonstrated sensitivity to exchange rate movements during the crisis periods of both the Asian financial crisis of 1997 and the global financial crisis of 2008. Second, a specification of the stochastic volatilities in TVP-VAR model is important in explaining excessive movements of all variables in the sample. The overall moderation of variables in 2000s was more or less due to a reduction of the stochastic volatilities but also somewhat due to the macroeconomic fundamental structures captured by impulse response functons. Third, the degree of the monetary policy effectiveness of inflation was mitigated in recent periods but with increased persistence. Lastly, the monetary policy stance towards inflation stabilization has advanced ever since the inflation targeting scheme was adopted. However, there still seems to be a room for improvement in this aspect since the degree of the monetary policy stance towards inflation stabilization was relatively weaker than to output stabilization.

  • PDF

A Robust Acoustic Echo Canceler with Stepsize Predictor for Environment Noise (주변 노이즈에 강건한 Stepsize 예측기를 갖는 음향 반향 제거기)

  • Lee, Se-Won;Kang, Hee-Hoon;Lee, Won-Seok
    • Journal of the Institute of Electronics Engineers of Korea TE
    • /
    • v.39 no.2
    • /
    • pp.44-50
    • /
    • 2002
  • Conventional acoustic echo cancelers using ES(Exponentially weighted Stepsize) algorithm have simple operational configuration and fast convergence speed batter then NLMS algorithm, but they are very weak in external noise because ES algorithm updates filter taps using an average energy reduction rate of room impulse response in specific acoustical condition. So, a new configuration of acoustic echo canceler with stepsize generator and selector is proposed in this thesis. The proposed stepsize generator and selector improve conventional acoustic echo canceler's weakness in external noise and improve the system robustness. The stepsize generator generates additional stepsize value using moving averager, which is the residual noise energy of error signal multiplied by constant ${\gamma}$. The stepsize selector selects the stepsize value that has better performance in an acoustic echo canceler using a coefficient decision factor ${\Delta}_{differ}$ The simulation results show that the proposed algorithm reduces residual error by 5[dB] to 10[dB], improves misadjustment regardless of external noise's SNR. 

Establishment of the Room Acoustic Criteria for the Korean Traditional Music Halls Using Subjective Listening Tests (청감실험에 의한 국악당의 음향설계조건 설정)

  • Haan, Chan-Hoon;Shin, Jic-Su
    • The Journal of the Acoustical Society of Korea
    • /
    • v.26 no.7
    • /
    • pp.343-352
    • /
    • 2007
  • The present study aims to investigate the design standard for acoustic criteria of Korean traditional music which could be used for the design of Korean traditional music halls. In order to do this, subjective listening tests were undertaken to musicians using auralized sounds which were convolved with the impulse response of traditional instruments recorded in an anechoic chamber. 94 pairs of sound were made which have different value of acoustic parameters including RT, BR, Brilliance, G, C80, ITDG, IACC. A paired comparison method(PCM) was used to analyze the results from the subjective listening tests. The results show that the preference of acoustic criteria for the Korean traditional music is far different from those of western music. As a result, specific range of acoustic criteria were suggested for the appropriate acoustic conditions of Korean traditional music. Also, a guideline of the acoustic design of halls for performing the Korean traditional music was suggested which could be used as a basic reference in the future works.