• Title/Summary/Keyword: Room fire

Search Result 528, Processing Time 0.031 seconds

A Research on Thermal Properties & Fire Resistance of A Water Film Covered Glazing System for Large Atrium Space (대규모 아트리움에 적용되는 수박형성 유리벽의 열적 특성 및 내화성능에 관한 연구)

  • 박형주;지남용
    • Fire Science and Engineering
    • /
    • v.13 no.4
    • /
    • pp.38-55
    • /
    • 1999
  • In order practically to use fire-defective glazing materials for the compartment wall where a fire-protection rating is mandated, there have been many trials internationally, This research focuses on a feasibility that, if certain water film covered all surface of glass, the glazing system can endure without breaking out under the compartment fire. First of all, a water film spray system was specially designed to wet the entire surface of the glass and also to have tiny small amount of water rebounded from the surface after emitted from nozzles. After this system has proven to have perfect performance, small-scale tests were done to find out if the water film covered glazing system react to the high temperature curve in a small furnace room. Finally, on basis of the obtained data, full-scale experiments were done so that water-film covered glazing system can pass the Korean Standard (KS) test for fire resistance, KS F2257.

  • PDF

Service Design for Using the Drones in the Early Stages Fires of Dense Residential Areas (주택가 밀집지역 화재발생 초기 드론 활용 서비스디자인 연구)

  • Youn, Gyo-Hee
    • The Journal of the Korea Contents Association
    • /
    • v.19 no.11
    • /
    • pp.111-121
    • /
    • 2019
  • Recently, through the services that use drones at fire sites to deliver on-site and road conditions into the situation room and life-saving activities or the deliveries of first aid outfits at the accident scenes that are inaccessible to humans, there are more and more cases of dealing with emergency situations. Therefore, by studying the service design using drones in the initial stage of response to fires in dense residential areas, this study was intended to reify the service design area of the response stage, including the dispatch of fire sites and the fire suppression. To do this, through literature researches, research directions were explored by examining the concept and process review of service design, and by analyzing the application cases using service design. In order examine the validity of this study, a one-on-one interview was conducted to identify the use and problems of drones among incumbent firefighters, and identified the applicability of drones to fire sites by targeting drone experts. Field research was conducted to identify the location and distance of road conditions, site conditions, and 119 safety centers, by making Yongsan-gu, the most vulnerable area to fire in Seoul, as a research sample. And, among the methodologies of service design, Persona and Customer Journey Map were prepared and Insight was derived, by using virtual scenarios for the experience values and behavior analyses of the interested parties. Through these processes, this researcher intended to present the fire-response service design and help establish the direction of service design in the initial stages of fire in Korea.

Study on the Analysis of Differential Pressure of the Access Door for a Smoke Control Zone and the Effectiveness of the Measurement Criteria of its Opening Force (제연구역 출입문의 차압 및 개방력 측정기준의 실효성 분석에 관한 연구)

  • Lee, Jae-Ou;Choi, Chung-Seog
    • Fire Science and Engineering
    • /
    • v.26 no.4
    • /
    • pp.24-30
    • /
    • 2012
  • The purpose of this study is to analyze the problem in measuring the differential pressure between the fire area and the neighboring smoke control zone as well as the opening force of a fire door and to present the actual values measured by an objective method. NFSC 501A specifies that the force necessary to open an access door when operating a smoke control system shall be less than 110 N. When the smoke control system does not operate in the space where it is installed, the door opening force can be measured by the test method in KS F 2805. However, when the smoke control system operates, additional opening force is required to overcome the force generated by the differential pressure between the fire area and smoke control room. Therefore, it can be seen that the method proposed by the standard has insufficient reliability. The analog measuring device and digital measuring device showed that the opening forces, $F_a$ and $F_d$, of the fully closed door before the smoke control system were 27.8 N and 27.4 N, respectively. When the door remained open by $5^{\circ}$, the opening forces, $F_a$ and $F_d$, were 33 N and 33.6 N, respectively. When the smoke control system operated and the door was fully closed, the door opening forces, $F_a$ and $F_d$, were 77.6 N and 76.0 N, respectively. Therefore, since the door opening forces are different from the criteria presented by KS F 2805, it is required to review the criteria appropriately.

A Study on Daylight Control Method for Securing Visual Comfort and Reducing Lighting Loads on Interior Lighting Environment (실내조명환경의 시각적 쾌적성 확보 및 조명부하 저감을 위한 채광제어방법에 관한 연구)

  • Han, Sang-Pil
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.6
    • /
    • pp.100-105
    • /
    • 2012
  • In previous study, to investigate the impression of the compound lighting based on the AC-Model at the full-size room, the impressions of various compound lighting were completed as compared with that of the uniform lightings through the comparison method (a paired comparison) by Semantic Differential scaling. Also, we examined the effect of the supplementary lighting type increasing the lights at the side of the window and the blind-control lighting type, and they were compared with the existing compound lighting type. In results, pared comparison of the compound lighting and the uniform lighting, indicates that the impression of the compound lighting is generally similar to that of the uniform lighting when there are same ratios of the light from the window. Based on these results, we suggest that the AC-Model might be applied to various conditions. And we also introduce the method for daylighting that it is possible to reduce discomfort glare and to improve visual impressions as the supplementary type and blind-control type on the compound lighting. And it was found that electric power consumption of the compound lighting room was lower than that of the uniform lighting room when as same lighting ratio of the compound lighting and the uniform lighting from the window was provided or there was the lighting distribution simulated to same light ratio from the window. Since the method of the ACModel was described in the experimental condition, additional studies should be performed to determine if this model could be applied to different window configurations, lighting layout and types of a room.

Design of PTZ Camera-Based Multiview Monitoring System for Efficient Observation in Vessel Engine Room (선박 기관실의 효율적인 감시를 위한 PTZ 카메라 기반의 멀티뷰 모니터링 시스템 설계)

  • Kim, Heon-Hui;Hong, Sang-Jun;Nam, Taek-Kun
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.27 no.7
    • /
    • pp.1129-1136
    • /
    • 2021
  • A pan-tilt-zoom (PTZ) camera-based monitoring system for efficient monitoring in the engine room of a vessel was designed. A number of places exist where traditional analog instruments are still used in vessel engine rooms, and blind spots closely related to safety exist, for which flooding or fire is a concern. A camera-based monitoring system that guarantees a wide range at a relatively fast cycle for these monitoring points can be an effective alternative to enhance the safety of a vessel. Therefore, a multiview monitoring system is proposed in which the functions of the existing PTZ camera are further strengthened using a software. The monitoring system comprises four modules: camera control, location registration, traversal control, and multiview image reconstruction. The effectiveness of the method was evaluated through a series of experiments in an engine room environment.

A Study on the Characteristics of the Multilayer-Type PTC Thermistor for Fire Detection Sensor (화재감지센서 활용을 위한 적층헝 PTC서미스터의 특성에 관한 연구)

  • Chu Soon-Nam;Baek Dong-Hyun
    • Fire Science and Engineering
    • /
    • v.19 no.2 s.58
    • /
    • pp.75-80
    • /
    • 2005
  • This dissertation is about the development of PTC(Positive Temperature Coefficient) thermistor by composition method. A multilayer-type PTC samples were fabricated under optimal conditions after setting the experimental composition equation as $(0.90Ba+0.05Sr+0.05Ca)TiO_3+0.01TiO_3+0.01SiO_2+0.0008MnO_2+0.0018Nb_2O_5$ and their testing results were analyzed. The fabrication method of SMD(Surface Mounted Device) multilayer -type sample based on the composition ratio has the advantages in lowering its resistivity at room temperature, considerably, and increasing maximum current level, as needed. Although there is a disadvantage of peak resistivity drop by the multilayer, causing the increasement of thermal capacity. and thereby, increasing the switching delay time, a high applying voltage can increase the peak resistivity and shorten the switching delay time. The voltage-current characteristic showed that the more multilayers increased the initial maximum current and the transition voltage that increased the resistivity abruptly according to the curie point. The element it could be applied with the sensor for the fire detector.

Experimental Study on Features of Air Egress Velocity in Vestibule Pressurization System (특별피난계단 부속실 제연설비의 방연풍속 기류특성에 관한 실험적 연구)

  • Ryu, Sung-Ho;Lee, Su-Kyung;Hong, Dae-Hwa;Yoon, Myong-O;Choi, Keum-Ran;Park, Jae-Hyun
    • Fire Science and Engineering
    • /
    • v.24 no.5
    • /
    • pp.79-86
    • /
    • 2010
  • In this study, we confirmed the fact that air egress velocity of pressure differential system which is installed in vestibule of smokeproof stairway in domestic high-rise building becomes back-flow into the vestibule not into the livingroom when the doors open to escape in case of fire by actual measurement. It concerned that fire smoke inflow into the vestibule of smokeproof stairway. so, reflux symptoms were developing the condition does not occur by creating an area of $2m^2$ and a model. if it‘s area is less, airflow in upper area was severely reflux. in the case upward 45 gradient of supply damper’s angle of blade, The results that reflux symptoms include upper door but bottom has some reflux. also vestibule of smokeproof stairway‘s area of $4m^2$ in the living room door in the direction of the flow distributon was normal. if a vestibule of smokeproof stairway is smaller, it designed to be performance-based design should be.

A Study on Design Improvement for Smoke-Control System Using the Pressurization of the Elevator Shaft (승강로 가압 제연설비의 설계개선에 관한 연구)

  • Kim, Il-Young;Kim, Kyung-Jin;Hong, Ji-Hwan;Kwon, Chang-Hee;Yoo, Chul-Kwon
    • Fire Science and Engineering
    • /
    • v.33 no.3
    • /
    • pp.74-83
    • /
    • 2019
  • In the U.S., the pressurization of elevator shaft was developed in 1972 to allow vulnerable people, such as the elderly and weak who could not use escape stairs in case of fire, to evacuate. It is an advantage in terms of space saving by not using vertical ducts. This study drew the problem of the pressurization of elevator shaft based on the existing domestic patents and proposed improvements. The smoke control volume calculation method is proposed by using vertical modeling. Leakage gaps in elevator doors need to be reviewed through experimental data or actual data. The evacuation floor was divided, the openings in the elevator machine room were automatically closed to the fire signal and the relief damper was installed to improve the performance. The improved method functions as the smoke control damper supplying the air flow rather than maintaining the differential pressure. To increase reliability of the research results, the procedure was performed to verify by using Contam.

Combustion Characteristics of Pinus rigida Specimens Treated with Phosphorus-Nitrogen Additives (인-질소 첨가제로 처리된 리기다 소나무 시험편의 연소특성)

  • Chung, Yeong-Jin
    • Fire Science and Engineering
    • /
    • v.29 no.6
    • /
    • pp.13-19
    • /
    • 2015
  • This study was performed to test the combustive properties of Pinus rigida specimens treated with phosphorus (P) and nitrogen (N) additives. Each Pinus rigida specimen was painted three times with 15 wt% P-N additive solutions at room temperature. After drying the treated specimens, the combustion properties were examined using a cone calorimeter (ISO 5660-1). The time to ignition (TTI) for the treated specimens was 90 to 148 s except for the specimen treated with PP/$4NH_4^+$, and the time to flameout (TF) was 556 to 633 s, which was longer than that of virgin plate. While the The specimens treated with P-N additives showed 12.5 to 43.4% higher mean heat release rate ($HRR_{mean}$) and 11.8 to 43.1% higher total heat release (THR) than virgin plate. The effective heat of combustion (EHC) was by 2.9 to 17.5% lower than that of virgin plate. It can thus be concluded that the combustion-retardation properties were partially improved compared to those of virgin plate.

Combustion Chracteristics of the Pinus rigida and Castanea savita Dried at Room Temperature (실온에서 건조된 리기다 소나무와 밤나무의 연소특성)

  • Chung, Yeong-Jin;Jin, Eui
    • Fire Science and Engineering
    • /
    • v.24 no.3
    • /
    • pp.86-92
    • /
    • 2010
  • One of the limitation of wood as building materials is its flammability. The purpose of this paper is to examine the combustion properties of the Pinus rigida and Castanea savita which are grown in Korea and meet the desirable characteristics for use of construction materials. The cone calorimeter (ISO 5660-1) was used to determine the heat release rate (HRR) and fire smoke index, as well as CO and $CO_2$ production and smoke obscuration. The $HRR_{mean}$ of the Castanea savita and Pinus rigida at $50\;kW/m^2$ of radiant heat flux was $70.4\;kW/m^2$ and $68.5\;kW/m^2$. Furthermore, the THR of Castanea sativata was 120.8 MJ/kg and it was higher than the THR of Pinus rigida ($81.9\;MJ/m^$). These results are depend on the bulk density of tested wood species. The Castanea savita has high $CO_{mean}$ yield and high CO/$CO_2$ yield compared with that of Pinus rigida.