A Model Experiment Study to Secure the Straight Line Distance between the Air Inlet and Exhaust Section of the Living Room (거실제연설비중 공기유입구와 배출구간 직선거리 확보를 위한 모형실험연구)

  • Saeng-Gon Lee;Se-Hong Min
    • Journal of the Society of Disaster Information
    • /
    • v.19 no.2
    • /
    • pp.439-450
    • /
    • 2023
  • Purpose: When conducting fire inspections in Korea, there are objects that violate the fire protection regulations that require a straight line distance of more than 5m between the air inlet and the discharge section if the floor area is less than 400m2, and this paper analyzes the reasons and conducts a model experimental study to support the need for related fire protection regulations. Method: Domestic firefighting objects were investigated and confirmed, domestic and foreign papers, policies, and laws and regulations were examined, and spaces with a straight line distance of less than 5m and more than 5m between the air inlet and discharge section were selected and analyzed through model experiments in a living room of less than 400m2 . Result: When examining the domestic fire protection regulations (NFPCNational Fire Perpormance Code), the separation distance between the air inlet and the outlet is more than 5m when the floor area is less than 400m2 , but as a result of the actual investigation, it was confirmed that there are firefighting objects that cannot keep the separation distance. In addition, when a paper review of overseas fire protection regulations for a straight line distance of more than 5m showed that there was no regulation on the straight line distance between the air inlet and the discharge section, the model experiment showed that the discharge speed was better when the straight line distance between the air inlet and the discharge section was more than 5m than when it was less than 5m. Conclusions: In this study, when examining overseas fire laws and regulations by comparing the performance of the fire protection ratio for the straight line distance between the air inlet and the exhaust section, there is no mandatory regulation for the straight line distance, but the domestic fire protection regulations (NFPCNational Fire Perpormance Code) require more than 5m. It is hoped that this will be reflected in the design stage in the future, and a foundation will be laid to reduce the responsibility and burden of fire superintendents.

A Study on the Flow Coefficient of Compartment Fire (건물화재시 개구부의 흐름계수에 관한 연구)

  • 허만성
    • Fire Science and Engineering
    • /
    • v.10 no.4
    • /
    • pp.19-27
    • /
    • 1996
  • The objective of this research is to study on the upper layer temperature, interface height and flow regime in case of several furniture fires such as trashcan, chair, carpet, sofa, mattress and wardrobe as a fire starter in a residential room by performing the experimental studies. The upper layer temperature and the Interface height were relatively well agreed with the experimental results when the flow coefficient at the opening was 0.65-0.8 for the rectangular trashcan, 0.65-0.9 for the circular trashcan and chair, and 0.7-0.9 for the carpet, sofa, mattress and wardrobe. The interface heights for the seven furniture fires were around 1[m] maintaining steady state. However, at the time of the maximum temperature, the interface height was lowered to 0.25[m]-0.75[m] from the floor. The flow regime at the opening was filling and buoyant for the distributed fire, and for the concentrated fire it was filling and then quickly changed to flow, and the flow period was long. The descending speed of the interface height was proportioned to the inflammability of the furniture and the contact surface area with air. The time required to come down around 1[m] was within 1-3 minutes.

  • PDF

A Study on Development way of Fire fighting 119 angers of Jeju Islander (제주도민의 119화를 위한 소방의 발전방안)

  • Koh, Jae-Moon;Kim, Tae-Min;Kim, Hyo-Sik
    • The Korean Journal of Emergency Medical Services
    • /
    • v.7 no.1
    • /
    • pp.147-178
    • /
    • 2003
  • In terms of reinforcing the functions and services of rescue 119 and emergency corps, we must review the following considerations : Building up security system along with operational expansion, building up a system for emergency medical treatment, buliding up a comprehensive information management system for rescue and emergency, constructing a provincial safety museum and so forth. For the ways to better the works of rescue 119, we can review the following considerations : Improving the education for fire fighting trainging corps under Jeju Provicial Fire and disaster management department, providing rescue members with more opportunity for clinical practices, enhancing the morale of rescue members, installing a comprehensive briefing room for emergency rescue members, building up medical networks along with reasonable policies for information service, operating the consulting system for rescue 119 and so on. Provide little more superior quality high fire fighting service to jeju islander, and need long-term and elaborate research to correspond in rising fire fighting man-power demand newly and investment. Construction of well-matched disaster administration system is assignment that must hurry in international free city. That jejudo receives time factor about that is received for another thing area's number of persons or equipment when regional special quality large scale or disaster happens is that of course the support receives limitation immediately. Jeju fire fighting services is one story reform, specialization taking into account particular situation of jeju area to grow as sightseeing and center of culture intending international free city, should be upgraded. So, it may do big contribution naturally in jeju international free city phase that coincide jeju islander's social welfare promotion and safety desire.

  • PDF

A Study of Evacuation in Elderly Care Facilities Fire (요양시설 화재 시 피난에 관한 연구)

  • Cha, Jong-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.11
    • /
    • pp.602-607
    • /
    • 2017
  • The development of science and technology has increased the average life expectancy and resulted in a significant increase in the elderly population. Due to the preponderance of the nuclear family in modern society and the weakening of the spirit of filial piety and respect for the elderly caused by the influence of Western civilization, elderly people are usually not living with their family, but have become dependent on elderly care facilities and, consequently, the number of elderly care facilities has increased significantly. On May 28, 2014, a fire occurred in the elderly care facilities in Jangseong, South Jeolla Province, and despite the rapid extinction of the fire by firefighters, 21 of the 28 casualties died due to smoke inhalation. This study was conducted for the purpose of providing measures to prevent smoke from entering into the rooms from which elderly people have difficulty evacuating in the case of fire. The use of the air curtain method to prevent smoke inflow was proposed and an experiment was conducted in which smoke was generated with a smoke generator. As a result of the experiment, it was confirmed that more than 90% of the smoke inflow was blocked if the door was closed in the room where the air curtain was installed.

Bending Tests of H steel-Partial Concrete Incased Composite Beams (H형강-국부 콘크리트 합성보지 휨 실험)

  • Kim, Sung-Hoon;Kim, Dae-Kon
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.9 no.3 s.43
    • /
    • pp.77-85
    • /
    • 2005
  • After the collapse of the World Trade Center in september 11, 2001 and due to the frequent fire-caused damages of buildings during earthquake attacks, social concerns have been increased for the fire proof of the structural members of buildings. Recently, researches have been conducted to improve the fire resistance for building members not by the traditional ways but by utilizing the fire-resisting characteristics of reinforced concrete and structural characteristics of H-steel. In this paper, laboratory tests were conducted in room temperature to investigate the structural performance of the composite beams, which were developed to improve the fire resistance, comprising with concrete incasement between upper and lower flanges of H steel. From the experimental results, the displacement ductility factors of $6\~8$ were obtained. The difference of flexural behavior ol H steel-partial concrete incased composite beams with various composite details seems to be minor. The amount of longitudinal rebars is the most influential factor for the flexural strength of the composite beams. Therefore, if this type of composite beams are selected for designing a building located in moderate seismic lone, identical beam size could be used in several stories of the building.

Characteristics of Air Egress Velocity in Vestibule Pressurization System Using the Fire Dynamics Simulator (FDS를 이용한 특별피난계단 부속실 제연설비의 방연풍속 기류특성)

  • Ryu, Sung-Ho;Lee, Su-Kyung;Hong, Dae-Hwa;Choi, Keum-Ran
    • Fire Science and Engineering
    • /
    • v.24 no.6
    • /
    • pp.153-159
    • /
    • 2010
  • In this study, we confirmed the fact that air egress velocity of pressure differential system installed at vestibule of smokeproof stairway in domestic high-rise building becomes back-flow to stair-lobby at upper vestibule. Rather it do not back-flow to the livingroom. when fire occur and the door opens to escape from fire zone. so we carry out actual and computational fluid dynamics measurement. In the case upward 45 gradient of supply damper's blade, The simulation results that air flow of upper vestible is steady but back-flow phenomenon occurred at the bottom. However, in the case of $4m^2$, direction of the flow was ideal to living room. If a vestibule’s area is smaller, it must be designed and built according to performance-based design.

Performance Evaluation of a Natural Smoke Ventilator in Jeju (배연창의 개방층 설정방식에 따른 배연성능 평가 연구(제주지역 중심으로))

  • Lim, Chae-Hyun
    • Fire Science and Engineering
    • /
    • v.30 no.1
    • /
    • pp.6-11
    • /
    • 2016
  • This study analyzed the performance of smoke exhaustion installed to secure the life safety from the smoke each opening modes, as performing the simulation on the Jeju regions generating to strong windy using CONTAM. We assessed the effectiveness of the system under conditions of high external winds as well as an ambient wind conditions. It also assessed the relative effectiveness of opening all vents versus opening only those vents which served rooms in which the fire was located. This study revealed external winds exerted a substantial impact on the performance of the smoke ventilation system. It was found that opening the ventilation system in the room containing the fire resulted in a greater performance than opening vents in both fire in all rooms. The reduced performance of the smoke ventilation system upon the opening of all vents is thought to be due to the intrusion of outside air, and the establishment of unfavorable air circulation, caused by the negative pressure generated in the building.

The 2018 Fire department emergency medical technician survey (2018년 소방공무원 응급구조사 총조사)

  • Yun, Hyeongwan;Park, Jooho;Lee, Hyeongyeong;Han, Seungtae;Lee, Jeamin
    • The Korean Journal of Emergency Medical Services
    • /
    • v.25 no.3
    • /
    • pp.145-162
    • /
    • 2021
  • Purpose: The 2018 General survey of emergency assistance was conducted to examine the working conditions and welfare, including educational direction, interests, and awareness of work, of the fire department emergency medical technicians (EMT). This would be used as basic data for future policy directions. Methods: Among the fire-fighting officers in 16 cities nationwide, emergency rescue workers engaged in first-aid activities were targeted. With prior consent, a survey was conducted through electronic documents. Of the total 1,227 people, responses from 1,151 were finally analyzed, excluding 76 who did not respond appropriately. Results: The working conditions and welfare of 119 firefighters were moderate, but in the fields of education and interest, the learning according to the regulations was high. In particular, satisfaction with the scope of work was found to be below average. However, it was positive that it will play a role as a social safety net in the future and will converge with cutting-edge science. Conclusion: Although this study was a total investigation of the EMT survey, conducting an EMT survey on all fire fighters in Korea is difficult. Further research is needed, particularly on first-class emergency medical personnel who play a major role in 119 paramedics.

A Study on the Multiple Spurious Operation Analysis in Fire Events Probabilistic Safety Assessment of Domestic Nuclear Power Plant (국내 원자력발전소의 화재사건 확률론적안전성평가에서 다중오동작 분석 연구)

  • Kang, Dae Il;Jung, Yong Hun;Choi, Sun Yeong;Hwang, Mee-Jeong
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.6
    • /
    • pp.136-143
    • /
    • 2018
  • In this study, we conducted a pilot study on the multiple spurious operations (MSO) analysis in the fire probabilistic safety assessment (PSA) of domestic nuclear power plant (NPP) to identify the degree of influence of the operator actions used in the MSO mitigation strategies. The MSO scenario of the domestic reference NPP selected for this study is refueling water tank (RWT) drain down event. It could be caused by spurious operations of the containment spray system (CSS) of the reference NPP. The RWT drain down event can be stopped by the main control room (MCR) operator actions for stopping the operation of CSS pump or closing the CSS motor operated valve if the containment spray actuation signal (CSAS) is spuriously actuated. Outside the MCR, it can be stopped by operator actions for closing the CSS manual valves or motor operated valve or stopping the operation of CSS pump. The quantification result of a fire PSA model that takes into account all recovery actions for the RWT drain down event lead to risk reduction by about 95%, compared with quantification result of fire PSA model without considering them. Among the various operator actions, the recovery action for the spurious CSAS operations and the operator action for the manual valve are identified as the most important operator actions. This study quantitatively showed the extent to which the operator actions used as MSO countermeasures have affected the fire PSA quantification results. In addition, we can see the rank of importance among the operator recovery actions in quantitative terms.

Experimental and numerical investigation on post-earthquake fire behaviour of the circular concrete-filled steel tube columns

  • Wang, Yu-Hang;Tang, Qi;Su, Mei-Ni;Tan, Ji-Ke;Wang, Wei-Yong;Lan, Yong-Sen;Deng, Xiao-Wei;Bai, Yong-Tao;Luo, Wei;Li, Xiao-Hua;Bai, Jiu-Lin
    • Steel and Composite Structures
    • /
    • v.38 no.1
    • /
    • pp.17-31
    • /
    • 2021
  • Post-earthquake fire is a common disaster which causes serious safety issues to infrastructures. This study aims to investigate the residual loading capacities of circular concrete-filled steel tube (CFST) columns under post-earthquake fire experimentally and numerically. The experimental programme contains two loading steps - pre-damage cyclic loading at room temperature and transient state tests with constant compression loads. Three finite element models are developed and validated against the test results. Upon validation, a total of 48 numerical results were generated in the parametric study to investigate the effects of thickness and strengths of steel tube, axial compression ratio and damage degree on the fire resistance of circular CFST columns. Based on the analysis on experimental and numerical results, the loading mechanism of circular CFST columns is discussed. A design method is proposed for the prediction of fire resistance time under different seismic pre-damage and compression loads. The predictions by the new method is compared with the newly generated experimental and numerical results and is found to be accurate and consistent with the mean value close to the unity and a coefficient of variation around 1%.