• Title/Summary/Keyword: Room fire

Search Result 528, Processing Time 0.032 seconds

A Study on the Characterstics of the BaT$iO_3$PTC Thermistor for Fire Detection Sensor (화재감지센서 활용을 위한 BaT$iO_3$계 PTC 서미스터의 특성에 관한 연구)

  • 추순남;최명규;백동현;박정철
    • Fire Science and Engineering
    • /
    • v.16 no.4
    • /
    • pp.15-19
    • /
    • 2002
  • This dissertation is about the development of $BaTiO_3$-type PTC(Positive Temperature Coefficient) thermistor by composition method. A multilayer-type PTC samples were fabricated under optimal conditions after setting the experimental composition equation as ($Ba_{0.95-x}$S $r_{0.05}$$Ca_{x}$ )$TiO_3$-$0.01TiO_2$-$0.01SiO_2$-$\alpha$$MnCO_3$-$\beta$N $b_2$ $O_{5}$.) and their testing results were analyzed. The optimal sin-tering and cooling temperatures were 13$50^{\circ}C$ for two hours and $100^{\circ}C$/h for an hour, respectively; By composing Ca and Mn, dopants to lower the resistivity at room temperature, and Nb, a dopant to raise peak resistivity(Ca:5 mol%, Mn:0.08 mol%, Nb:0.18 mol%), appropriately, a PTC thermistor, having the characteristics of relatively low resistivity at room temperature and high peak resistivity and a good temperature coefficient, has been developed. And we find that it is possible of application for fire detection sensor.r.r.

A Study On Effectiveness of Prevent Smoke Backflow in Apartment (계단식 공동주택 방연풍속 실효성에 대한 연구)

  • Lee, Kwang­Soo;Yoon, Myong­O;Lee, Jun
    • Journal of the Society of Disaster Information
    • /
    • v.17 no.1
    • /
    • pp.1-9
    • /
    • 2021
  • Purpose: The purpose of this study is to analyze the differential pressure and velocity to prevent smoke backflow of Stairways Apartment House fire, and verified the effectiveness of smoke velocity standards proposed by NFSC 501A. Method: The smoke control design of the stairways apartment house of the real model and the performance of the velocity to prevent smoke backflow according to the window opening conditions of the living room were analyzed using the CONTAM program. Result: Although the differential pressure performance of the apartment's smoke control system was satisfactory, it was found that Performance of velocity to prevent smoke backflow did not come out according to the opening condition of the living room window. Conclusion: In the case of Stairways Apartment House, it is necessary to review the method of making exceptions to the 'velocity to prevent smoke backflow' standard required by the National Fire Safety Codes(NFSC 501A)

A Study on the Characteristics of FDS Heat Release Rate Predictions for Fire involving Solid Combustible Materials in a Closed Compartment (밀폐된 구획 내 복합소재 고체 가연물의 연소시 열방출률의 FDS 예측 특성)

  • Hong, Ter-Ki;Roh, Beom-Seok;Park, Seul-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.11
    • /
    • pp.349-356
    • /
    • 2020
  • The heat release rate (HRR) and fire growth rate of fire for the solid combustibles consisting of multi-materials was measured through the ISO 9705 room corner test, and the computational analysis in a closed compartment was performed to simulate a fire using the heat release rate prediction model provided by a Fire Dynamics Simulator (FDS). The method of predicting the heat release rate provided by the FDS was divided into a simple model and a pyrolysis model. Each model was applied and computational analysis was performed under the same conditions. As the solid combustible consisting of multi-materials, a cinema chair composed mostly of PU foam, PP, and steel was selected. The simple model was over-predicted compared to the predicted heat release rate and fire growth rate using the pyrolysis model in a closed compartment.

A Study on the Fire Safety Assessment of a Ship (선박의 화재안전도에 관한 연구)

  • Jung-Hoon Lee;Jae-Ohk Lee;Young-Soon Yang
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.38 no.1
    • /
    • pp.116-122
    • /
    • 2001
  • In this paper, to make a base of the fire safety assessment about ship's fire protection design and Classification Society rule, statistical informations and modeling techniques for the fire safety engineering are investigated and probabilistic safety assessment methods in the structural reliability engineering are introduced. FSEM(Fire Safety Evaluation Module) developed in this paper calculates the probability of fatality, which can be used as an index of fire safety. FSEM is used to calculate the probability of fatality of the evacuees in a small room installed according to the rules for fire-proof. Sensitivity analysis is executed to investigate FSEM's applicability to ship. From results, the necessity of new criterion for ship's fire safety design, the need to study the human behavior in the evacuation from fire, and the development of new fire progress model considering special situations in ships are acknowledged.

  • PDF

The Comparative Analysis of Passenger Evacuation Results Using CFAST and FLUENT (CFAST 와 FLUENT 화재유동해석을 통한 승객피난 시뮬레이션 결과 비교분석)

  • Jang, Yong-Jun;Park, Won-Hee;Jung, Woo-Sung;Lee, Chang-Hyun
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.1354-1361
    • /
    • 2007
  • The evacuation simulation study was performed with the boundary condition of a fire simulator, referring to Dae-gu Subway Fire Accident which was a real station fire. The subway station was modelled from B3F station building to B2F waiting room in fire simulation. Also, a fire simulation were performed with CFAST and FLUENT. In CFAST, the total 29 zones were divided into 18 station buildings in B3F and 11 station buildings in B2F. In FLUENT, the simulated space had the same establishment as zone of CFAST. The study focused on possibility for application of fire simulation in underground station by comparing the resulted values from two simulators. For application of fire effect, the fire data were loaded directly to EXODUS in the case of CFAST and performed a passenger evacuation simulation. In the case of FLUENT, Out Data values of a fire simulation were difficult to be compatible with EXODUS. Two resulted values of passenger evacuation simulation by fire simulation were compared with the Dae-gu Subway Fire Accident in reality.

  • PDF

On the Reliability of the Computational Fire Model Based on the Yield Rate Concept of Combustion Gases (생성율 개념에 기초한 화재모델의 신뢰성에 대한 연구)

  • Kim, Sung-Chan;Ko, Gwon-Hyun;Lee, Seong-Hyuk
    • Fire Science and Engineering
    • /
    • v.23 no.4
    • /
    • pp.130-136
    • /
    • 2009
  • The present study has been performed to evaluate the reliability of the fire field model (FDS version 5.2) with yield rate concept of combustion products. The CO and smoke density predicted by FDS model was directly compared with measurement in a reduced scale ISO-9705 room. The GER (global equivalence ratio) concept was used to characterize the CO and smoke density with ventilation condition in the fire compartment. The FDS model tends to under-predict CO concentration and smoke density than those of measurement for the under-ventilated conditions. Also, the discrepancy between predicted and measured result increases as GER increases. In order to improve the reliability of the fire model for performance evaluation of fire safety, the fire model is necessary to be validated in various fire cases as well as develop detailed physical model.

Fire and Evacuation Analysis in Environmental Energy Facilities (환경에너지 시설내 화재 및 피난해석)

  • Jeon, Yong-Han;Kim, Jong-Yoon
    • Fire Science and Engineering
    • /
    • v.33 no.3
    • /
    • pp.84-90
    • /
    • 2019
  • In this study, a fire and evacuation inside an electronic equipment room in environmental energy facilities were conducted and evaluated using a numerical analysis method. In the fire simulation, the visual distance, temperature distribution, and CO concentration distribution were analyzed using FDS. Based on the results, the Pathfinder program, which is an evacuation simulation, was used to calculate the evacuation time of the occupants and derive an evacuation safety evaluation. As a result, the Available safe Egress time (ASET) of P-01 and P-05 was 203.3 and 398.6 s, respectively. For the Required safety Egress time (RSET) results, all evacuees were evacuated at all points and the safety of the evacuee was secured this simulation showed that the safety evaluation is based on the non - operation of the fire - fighting equipment to improve the safety, making it possible to secure better evacuation safety performance owing to the fire of other fire - fighting facilities.

A Study on Fire Dynamics Simulation on the Arrangement of Aero System in the Residential (주거공간 에어로 시스템 배치에 관한 화재시뮬레이션 연구)

  • Choi, Doo Chan;Ko, Min Hyeok;Lee, Doo Hee;Park, Kye Won;Choi, Jeong Min;Lee, Yong Kwon;Kim, Gil Nam;Sun, Kyoung Soo
    • Journal of the Society of Disaster Information
    • /
    • v.17 no.4
    • /
    • pp.890-896
    • /
    • 2021
  • Purpose: The called Aero System is important to find the well detected place in the livingroom or bedroom so, it needs to the confirmation through the Fire Dynamics Simulation Method: A fire simulation of a residential space of 59 m2 was performed, and in order to find the point where the fire environment was exposed quickly, measuring points were installed at 0.6 m and 1.5 m in height for each bedroom and living room, and the point where the fire was quickly detected was confirmed. Result: It was confirmed that the temperature and carbon monoxide sensor set at a point of 1.5 m was quickly detected at the reference value. Conclusion: The Fire detection would be relatively quick if the product in which the fire extinguishing module and the AQI module were separated was installed on the wall.

Buckling resistance behavior of WGJ420 fire-resistant weathering steel columns under fire

  • Yiran Wu;Xianglin Yu;Yongjiu Shi;Yonglei Xu;Huiyong Ban
    • Steel and Composite Structures
    • /
    • v.47 no.2
    • /
    • pp.269-287
    • /
    • 2023
  • The WGJ420 fire-resistant weathering (FRW) steel is developed and manufactured with standard yield strength of 420 MPa at room temperature, which is expected to significantly enhance the performance of steel structures with excellent fire and corrosion resistances, strong seismic capacity, high strength and ductility, good resilience and robustness. In this paper, the mechanical properties of FRW steel plates and buckling behavior of columns are investigated through tests at elevated temperatures. The stress-strain curves, mechanical properties of FRW steel such as modulus of elasticity, proof strength, tensile strength, as well as corresponding reduction factors are obtained and discussed. The recommended constitutive model based on the Ramberg-Osgood relationship, as well as the relevant formulas for mechanical properties are proposed, which provide fundamental mechanical parameters and references. A total of 12 FRW steel welded I-section columns with different slenderness ratios and buckling load ratios are tested under standard fire to understand the global buckling behavior in-depth. The influences of boundary conditions on the buckling failure modes as well as the critical temperatures are also investigated. In addition, the temperature distributions at different sections/locations of the columns are obtained. It is found that the buckling deformation curve can be divided into four stages: initial expansion stage, stable stage, compression stage and failure stage. The fire test results concluded that the residual buckling capacities of FRW steel columns are substantially higher than the conventional steel columns at elevated temperatures. Furthermore, the numerical results show good agreement with the fire test results in terms of the critical temperature and maximum axial elongation. Finally, the critical temperatures between the numerical results and various code/standard curves (GB 51249, Eurocode 3, AS 4100, BS 5950 and AISC) are compared and verified both in the buckling resistance domain and in the temperature domain. It is demonstrated that the FRW steel columns have sufficient safety redundancy for fire resistance when they are designed according to current codes or standards.

A Numerical Study on the Smoke Behavior by Solar Radiation through Ceiling Glass in Atrium Fires

  • Jeong, Jin-Yong
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.10 no.3
    • /
    • pp.117-128
    • /
    • 2002
  • This paper describes the smoke filling process of a fire field model based on a self-deve-loped SMEP (Smoke Movement Estimating Program) code to the simulation of fire induced flows in the two types of atrium space containing a ceiling heat flux. The SMEP using PISO algorithm solves conservation equations for mass, momentum, energy and species, together with those for the modified k-$\varepsilon$ turbulence model with buoyancy production term. Also it solves the radiation equation using the discrete ordinates method. Compressibility is assumed and the perfect gas law is used. Comparison of the calculated upper-layer average tempera-ture and smoke layer clear height with the zone models has shown reasonable agreement. The zone models used are the CFAST and the NBTC one-room. For atrium fires with ceiling glass the ceiling heat flux by solar heat causes a high smoke temperature near the ceiling. However, it has no effect on the smoke movement such as the smoke layer clear heights that are important in fire safety. In conclusion, the smoke layer clear heights that are important in evacuation activity except the early of a fire were not as sensitive as the smoke layer tem-perature to the nature of ceiling heat flux condition. Thus, a fire sensor in atrium with ceiling glass has to consider these phenomena.