• 제목/요약/키워드: Room fire

검색결과 528건 처리시간 0.029초

단일화재실험을 통한 화재성상예측 및 건축구조물의 화재안전 설계에 관한 연구 (A Study on the Fire Safety Design and Predicting Fire Behavior Using Compartment Fire Test)

  • 윤웅기;서동구;김동은;권영진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2013년도 춘계 학술논문 발표대회
    • /
    • pp.107-108
    • /
    • 2013
  • In this study, combustibles investigation and fire growth rate experiment were performed for predicting initial fire behavior in buildings. Combustibles investigation was performed for residential buildings, which is most frequently affected by fire in Korea. Spatial characteristics and combustibles properties were separately investigated, and occupied area and layout characteristics of combustibles were identified to produce general layout models. Of the layout models, room was selected for fire test of a single compartment. From this test, fire propagation for each combustible was identified, which was delayed compared to the summed heat release rate of a single combustible.

  • PDF

방화구획에 있어서 수막설비의 이론적 고찰 (An Analytical Study of Water Curtain in Fire Partition)

  • 김화중
    • 한국화재소방학회논문지
    • /
    • 제3권1호
    • /
    • pp.3-9
    • /
    • 1989
  • This paper is study that the mathemetical model of water mebrane splinklikler capacity in fire prevention block. The methmetical investigation are performed about prediction of five temperature in room and water membrane splinkler capacity by use of experimental model. The good correlation between predicted and experimental results is indication the adequacy of the mothemetical model. However. further experimental and analytical worke are needed before a more general mathemetical model can be proposed.

  • PDF

원자력발전소 주제어실 화재 시 공조모드가 배연성능 및 거주성에 미치는 영향 분석 (Effect of the HVAC Conditions on the Smoke Ventilation Performance and Habitability for a Main Control Room Fire in Nuclear Power Plant)

  • 김범규;임혁순;이영승;김명수
    • 한국화재소방학회논문지
    • /
    • 제30권5호
    • /
    • pp.74-81
    • /
    • 2016
  • 본 연구의 목적은 원자력발전소 주제어실 화재시 운전원의 거주성을 평가하는 것이다. 운전원의 거주성 분석을 위해 FDS v.6.0을 사용하였으며 이를 통해 주제어실 화재 시 배연성능과 운전원의 거주성에 있어 도출되는 문제점을 확인하였다. 본 연구에서는 공조환기설비의 운전조건을 핵심변수로 지정하고 그에 따라 3가지 시나리오로 분류하였다. 수치해석결과, Case 1(공조설비 작동시)의 경우가 연기온도, 복사열, 광학밀도 및 연기층높이에 의한 영향이 가장 심각한 것으로 나타났다. 이에 반해, Case 2(공조설비 미작동시)와 Case 3(공조설비 미작동시 풍량 1.5배 증가 시)는 Case 1보다 더 안전한 것으로 나타났다. 약 820초경 연기온도를 확인한 결과, Case 1이 Case 2와 Case 3보다 약 63% 정도 더 높게 나타났다. 복사열에 의한 영향도 Case 1에서 가장 높게 나타나, Case 2 및 Case 3와는 최대 약 68% 이상의 차이를 보였다. 분석결과를 통해, 주제어실의 공조환기설비는 배연성능에 큰 영향을 미쳐 운전원 거주안전을 지키기 위한 주요 인자인 것을 확인하였다. 다만, 급기구와 배연구가 천정부에 동시에 설치되어 있어 Case 2와 Case 3의 경우 연기층높이에 있어 불연속적 패턴을 나타냈다.

건물화재시 연기층 형성과 영역모델에 관한 연구 (A Study on the Formation of Smoke Layer and the Zone modelling in Compartment Fire)

  • 허만성
    • 한국안전학회지
    • /
    • 제12권4호
    • /
    • pp.70-78
    • /
    • 1997
  • The objective of this research is to study on the upper and lower layer temperature, interface height and pressure in case of carpet, chair, trashcan and wardrobe fires in a residential room by performing the theoretical and experimental studies. The theoretical results of the upper and lower layer temperature, the interface height and the pressure were qualitatively well coincided with the experimental results. The uniformly distributed fire in case of carpet showed that the ignition and the initial growth period were relatively short while the fully developed period was considerably long. The concentrated fires such as the wardrobe showed that the ignitions and the initial growth periods were relatively long. The interface heights were around 1m as the steady state. However, at the time of the maximum temperature, the interface height was lowered to 0.5m from the floor. The pressure variation in the fire room ranged between 0.1mmAq and 0.4mmAq, and the temperature reached the highest while the pressure was maximum.

  • PDF

방범·방재 기능을 갖는 에너지 절약형 조명기기 구현 (The implement of energy saving illuminator with a function of crime and fire prevention)

  • 한영오
    • 한국전자통신학회논문지
    • /
    • 제5권3호
    • /
    • pp.339-343
    • /
    • 2010
  • 본 연구에서는 방범방재 기능을 갖는 에너지 절약형 조명기기를 개발하였다. 개발된 조명기기와 관리실을 지그비 무선통신으로 연결하여 조명기기에서 획득된 정보를 전송할 수 있어 편리하게 모니터링이 가능하다. 본 조명기기를 교실 또는 사무실 내부에 여러 개의 일반 형광등과 병행하여 1개만 설치하면 학교 또는 일반 건물을 위한 저비용 방범방재 및 에너지절약형 무선 네트워크 시스템 구축이 가능하다.

단일구획실험을 통한 화재안전설계에 관한 기초적 연구 (A Basic Study on the Fire Experiment of a Single Area for Fire Safety Design.)

  • 김동은;윤웅기;서동구;권영진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2013년도 추계 학술논문 발표대회
    • /
    • pp.110-111
    • /
    • 2013
  • This research studies in the field of domestic fires are an issue in many scientific fire research as a research method to validate the domestic environment and ISO-9705 housing on the basis of experiments in virtual space by making a single fire compartment space for conducting experiments and Appearance of a fire occurring within each flammable Heat Release Rate analysis was carried out mainly. Placed within the space of one flammable HRR calculated as the sum of the number of single-room fire experiments conducted and the results compared with the value in comparing the conduct of fire locations and fire load within the building area of the future, the HRR value represents the change in domestic a consideration of the safety of the building is to propose matters.

  • PDF

건축물 실내화재의 단계에 대한 연구 (Study on building room fire development stages)

  • 차종호
    • 한국방재학회:학술대회논문집
    • /
    • 한국방재학회 2008년도 정기총회 및 학술발표대회
    • /
    • pp.169-172
    • /
    • 2008
  • 기존의 문헌들은 화재시 화재단계, 피난, 건물구조, 화재감지 등을 별개의 개념으로 정리하였으나 이 논문에서는 건축물 실내화재의 단계를 초기-성장기-Flash Over-감쇠기로 나누고 그에 해당되는 화재의 단계, 연소의 진행특성, 인간의 대응 특성, 화재의 동적방호, 화재감지를 정리하고 그로 인하여 인명보호, 재산보호를 실현할 수 있고, 나아가 경제성 측면에서도 검측할 수 있도록 연구를 하였다.

  • PDF

공동주택에서의 화재경보음 전달 (Fire Alarm Sound Transmission in Apartment Units)

  • 정정호
    • 한국화재소방학회논문지
    • /
    • 제32권3호
    • /
    • pp.67-75
    • /
    • 2018
  • 공동주택 화재 발생시 인명피해 최소화 및 재실자의 신속한 대피를 위해서는 화재 발생 사실이 경보음을 통해 전체 세대로 전달되어야 한다. 공동주택의 경우 엘리베이터 실과 같은 공용공간에 경종이 설치되어 있으나, 세대내 공간으로 경보음이 충분히 전달되지 못하는 것으로 알려져 있다. 본 연구에서는 실제 공동주택에서의 주,야간 소음을 측정하여 공동주택 세대 내 소음 발생 실태를 조사하고 세대내 공간으로의 경보음 전달 정도를 분석하였다. 엘리베이터 실에서 발생되는 경보음이 공동주택 내부로 전달되는 경우 방화문 및 방문의 차음성능으로 인해 충분히 전달되지 못하는 것으로 나타났다. 공동주택 내에서 발생되는 각종 소음 레벨을 고려하면 공동주택 외부에서 발생되는 경보음을 청취하여 피난행동을 시작하는 데는 어려움이 있는 것으로 판단된다. 이를 개선하기 위해 공동주택 거실의 월패드와 각 방별로 경보음 발생기를 설치한 경우에 대하여 음향시뮬레이션을 실시하였다. 각 방별로 경보음 발생기를 설치한 경우에서만 배경소음 + 15 dB 기준과 75 dB (A) 기준을 만족하는 것으로 나타났다.

Structural stability of fire-resistant steel (FR490) H-section columns at elevated temperatures

  • Kwon, In-Kyu;Kwon, Young-Bong
    • Steel and Composite Structures
    • /
    • 제17권1호
    • /
    • pp.105-121
    • /
    • 2014
  • A fundamental limitation of steel structures is the decrease in their load-bearing capacity at high temperatures in fire situations such that structural members may require some additional treatment for fire resistance. In this regard, this paper evaluates the structural stability of fire-resistant steel, introduced in the late 1999s, through tensile coupon tests and proposes some experimental equations for the yield stress, the elastic modulus, and specific heat. The surface temperature, deflection, and maximum stress of fire-resistant steel H-section columns were calculated using their own mechanical and thermal properties. According to a comparison of mechanical properties between fire-resistant steel and Eurocode 3, the former outperformed the latter, and based on a comparison of structural performance between fire-resistant steel and ordinary structural steel of equivalent mechanical properties at room temperature, the former had greater structural stability than the latter through $900^{\circ}C$.

Fast and Efficient Method for Fire Detection Using Image Processing

  • Celik, Turgay
    • ETRI Journal
    • /
    • 제32권6호
    • /
    • pp.881-890
    • /
    • 2010
  • Conventional fire detection systems use physical sensors to detect fire. Chemical properties of particles in the air are acquired by sensors and are used by conventional fire detection systems to raise an alarm. However, this can also cause false alarms; for example, a person smoking in a room may trigger a typical fire alarm system. In order to manage false alarms of conventional fire detection systems, a computer vision-based fire detection algorithm is proposed in this paper. The proposed fire detection algorithm consists of two main parts: fire color modeling and motion detection. The algorithm can be used in parallel with conventional fire detection systems to reduce false alarms. It can also be deployed as a stand-alone system to detect fire by using video frames acquired through a video acquisition device. A novel fire color model is developed in CIE $L^*a^*b^*$ color space to identify fire pixels. The proposed fire color model is tested with ten diverse video sequences including different types of fire. The experimental results are quite encouraging in terms of correctly classifying fire pixels according to color information only. The overall fire detection system's performance is tested over a benchmark fire video database, and its performance is compared with the state-of-the-art fire detection method.