• 제목/요약/키워드: Room air

검색결과 1,745건 처리시간 0.027초

교환기실의 급배기방식에 따른 통신 시스템의 냉각 특성 (Cooling characteristics of the telecommunication system in a switching room for various air supply and return flow system)

  • 노홍구;이재헌;고철균
    • 설비공학논문집
    • /
    • 제11권5호
    • /
    • pp.669-683
    • /
    • 1999
  • Heat dissipation in the domestic switching room has been gradually increased. Therefore, numerical study on the cooling characteristics of the telecommunication system in a switching room for three kinds of the air supply and return flow system was investigated to develop effective flow system. As a result, the cooling performance of the under floor air supply and overhead return flow system was the best.

  • PDF

노래방과 컴퓨터 게임방 내의 실내공기오염에 관한 연구 (A Study on the Indoor Air Pollution of Singing Room and PC Room)

  • 이주상;원정일;이철민;김윤신
    • 환경위생공학
    • /
    • 제17권3호
    • /
    • pp.67-74
    • /
    • 2002
  • Nowadays, a new word called SBS(sick building syndrome) has been come into existence. Since most people spend a large majority of their time indoors, indoor air may affect human health more than outdoor air. This outline survey was carried out to investigate the extent of indoor air pollution in singing room and PC room. The concentrations of major indoor air pollutants(carbon dioxide, total suspended particulate, airborne microbes) and Thermocircumstance(temperature, relative humidity, intensity of illumination) were observed from October 1 to 31, 2001. As results of the survey, the mom values of thermocircumstance in singing room and PC room were $22.1^{\circ}C$ of temperature, 37.1% of humidity, 75 Lux of intensity of illumination and $22.0^{\circ}C$ of temperature, 52.6% of humidity, 135 Lux of intensity of illumination, respectively. The mean concentrations of carbon dioxide were 1589 ppm in singing room and 615 ppm in PC room, respectively The concentrations of carbon dioxide in singing room were higher than the indoor environmental standard of the first clause of Article 45 of public utilization service which is showed at public hygiene of the Ministry of Health and Social Affairs. The mean concentrations of total suspended particulate were $0.33{\;}mg/\textrm{m}^3$ in singing room and $0.57{\;}mg/\textrm{m}^3$ in PC room respectively. The mean concentrations of airborne microbe were $16{\;}CFU/\textrm{m}^3$ in singing room and $12{\;}CFU/\textrm{m}^3$ in PC room, respectively.

수술실내 공기감염억제를 위한 공조용 급배기구 위치 선정에 관한 연구 (A Study on the Diffuser Location for the Reduction of Airborne Infection in Operation Room)

  • 권순정;주영철;김천숙
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제8권1호
    • /
    • pp.7-12
    • /
    • 2002
  • The air ventilation system of operation rooms has been studied to prevent the cross infection during the operation. Operation rooms and air ventilation systems of three University hospitals were investigated. The distribution of microbe was measured by cultivating air samples in the operation room. A two-dimensional model for the cross-section of an operation room was developed for the CFD(Computational Fluid Dynamics) analysis. The characteristics of air flow in the empty operation room and in occupied operation room were calculated by using a CFD program. The current diffuser location of an old hospital did not deliver the clean air to the operation part efficiently. A new method to locate diffusers that improve air venting with little increase of the cost of equipment was suggested.

  • PDF

반도체 클린룸용 배기 열회수식 외기공조시스템의 에너지소비 수치해석 (Numerical Analysis on Energy Consumption of an Exhaust Air Heat Recovery Type Outdoor Air Conditioning System for Semiconductor Manufacturing Clean Rooms)

  • 송근수;유경훈;김형태
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.1306-1311
    • /
    • 2009
  • In recent semiconductor manufacturing clean rooms, in order to improve clean room air quality, air washers are used to remove airborne gaseous contaminants such as $NH_3$, SOx and organic gases from the outdoor air introduced into clean room. Meanwhile, there is a large amount of exhaust air from a clean room. From an energy conservation point of view, heat recovery is therefore useful for reducing the outdoor air conditioning load for a clean room. Therefore it is desirable to recover heat from the exhaust air and use it to reheat the outdoor air. In the present study, numerical analysis and experiment was conducted to simulate the amount of energy reduction of exhaust air heat recovery type air washer system. The present numerical results showed good agreement with the results of the experimental data.

  • PDF

실내 공기질 평가를 위한 2구획 모델의 개발 (Development of the Two-Zone Model to Estimate the Air Quality in Indoor Environments)

  • 조석호;양성환;이봉헌;정성욱;이병호
    • 한국환경과학회지
    • /
    • 제7권6호
    • /
    • pp.745-751
    • /
    • 1998
  • The well-mixed room model has been traditionally used to predict the concentrations of contaminants in indoor environments. However, this is inappropriate because the flow fields in many indoor environments distribute contaminants non-uniformly, due to imperfect air mixing. Thus, some means used to describe an imperfectly mixed room are needed. The simplest model that accounts for imperfect air mixing is a two-zone model. Therefore, this study on development of computer program far the two-zone model is carried out to propose techniques of estimating the concentration of contaminants in the room. To do this, an important consideration is to divide a room into two-zone, i.e. the lower and upper zone assuming that the air and contaminants are well mixed within each zone. And between the zones the air recirculation is characterized through the air exchange parameter. By this basic assumption, the equations for the conservation of mass are derived for each zone. These equations are solved by using the computational technique. The language used to develope the program is a VISUAL BASIC. The value of air exchange coefficient($f_12$) is the most difficult to forecast when the concentrations of contaminants in an imperfectly mixed room are estimated by the two-zone model. But, as the value of $f_12$ increases, the air exchange between each zone increases. When the value of $f_12$ is approximately 15, the concentrations in both zone approach each other, and the entire room may be approximately treated as a single well-mixed room. Therefore, this study is available for designing of the ventilation to improve the air quality of indoor environments. Also, the two-zone model produces the theoretical base which may be extended to the theory for the multi-zone model, that will be contributed to estimate the air pollution in large enclosures, such as shopping malls, atria buildings, atria terminals, and covered sports stadia.

  • PDF

Air Shot Blast 작업실 내부 환기 시스템 개선에 관한 수치해석 (Numerical Analysis on the Ventilation System Improvement in Air Shot Blast Room)

  • 진도훈
    • 한국산업융합학회 논문집
    • /
    • 제25권5호
    • /
    • pp.861-868
    • /
    • 2022
  • The purpose of this study is to design an effective atmospheric environment system through the design of the dust collection in the air shot room being operated in a domestic shipyard. The ventilation system in the current air shot room mostly uses a dust collecting filter to filter internal particles and releases them in the atmosphere. A conventional design was made too much. In order to prevent an error and draw an optimal design, Computational fluid dynamics (CFD) tried to be applied only to air shot room. In the advanced design technique, computer simulation was conducted to secure basic design data. In order to find the basic design of the ventilation system and the flow field in the air shot room at propeller mold workplace of a shipyard, the CFD was conducted. In the case of Model-1 as a conventional workplace, where air flows in the inlet due to the subatmospheric pressure generated by inhalation of an air blower and flows out to the outlet, a discharge flow rate was somewhat low, and there was the holdup zone in the room. In the case of Model-2 as an improved model, the ventilation system was improved in the Push-Pull type, and the holdup of the internal flow field was improved.

급기환기량에 따른 공조기의 설정온도 도달특성 분석 연구 (A Study on the Reaching Time of Setting Temperature with Ventilation Air)

  • 강태욱
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제30권1호
    • /
    • pp.50-57
    • /
    • 2006
  • This study describes to analyze the cooling load characteristics for a room air conditioner as a function of supply ventilation air when an air conditioner is running An experimental apparatus consists of a test room, a room air conditioner, a humidifier, an electrical heater a supply fan and a controller The reaching time to the inside setting temperature of the room air conditioner with is evaluated theoretically and experimentally in a conditioned space cooling loads such as supply ventilation air, lighting, occupancy and infiltration. In the conditions of cooling loads for the supply ventilation air of 9.5 L/s(0.98 ACH). lights. one Person, and infiltration, the reaching time to the inside setting temperature ($27\;^{\circ}C$ dry-bulb) increases up to $35\%$ more than for no supply ventilation air condition. Theoretical modelling of the reaching time shows good agreement with experimental results.

An Experimental Study on Two Parameter Control for Radiant Floor Heating System

  • Cho, Sung-Hwan;Tae, Choon-Seob;Jang, Chel-Yong
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제6권
    • /
    • pp.136-147
    • /
    • 1998
  • An experimental facility consisting of two 3$\times$4.4$\times$2.8m rooms identical in construction is built. Each room has a control system and storage tank supplying hot water to the radiant floor heating system. The facility enables simultaneous comparison of two different control strategies each implemented in a separate room. The operating performance of three kinds of flow control scheme is tested and compared in this study: (ⅰ) conventional on-off control based on feedback from room air temperature (ⅱ) TPSC(two parameter switching control )(ⅲ) TPOC(two parameter on-off control). Results show that TPSC and TPOC using room air and surface temperature sequentially as feedback signal to control hot water supply is the better temperature regulation scheme than conventional control based on feedback from only room air temperature. They are good candidates for the room with radiant floor heating system under continuous and intermittent heating mode.

  • PDF

환기구를 가진 실내공간에서 복사 및 대류열전달의 비교 연구 (The Comparison Study of Radiative and Convective Heat Transfer in a Room Air Ventilation)

  • 정효민;정한식;김경근
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제21권3호
    • /
    • pp.229-235
    • /
    • 1997
  • The comparison of radiative and convective heat transfer in a room air ventilation is investi¬gated by a numerical simulation. The room air temperature distributions with radiation are appeared more uniform than without radiation at Gr= 1460 and Re=50. The mean Nusselt number in the radiative heat transfer shows less value than convective heat transfer. The total mean Nusselt number is found Wall 1> Wall 3${\fallingdotseq}$Wall 2 7 Wall 4.

  • PDF

실내(室內) 유입(流入) 냉기(冷氣)의 열유동(熱流動) 특성(特性)에 관한 실험적(實驗的) 연구(硏究) (An Experimental Study on Heat Flow Characteristics of Inflowing Cool Air in the Room)

  • 장영근;박정원;박이동
    • 태양에너지
    • /
    • 제18권1호
    • /
    • pp.57-67
    • /
    • 1998
  • 쾌적한 실내환경을 유지하고, 공기조화 설비에 있어서 냉방동안 에너지를 절약하기 위한 실내로 유입되는 냉기의 열유동 특성에 관한 연구이다. 실물 크기의 모형room에 대하여 실내로 유입하는 냉기의 유속(1, 2, 3m/s)과 실내온도와 유입냉기와의 기준온도차(10, 20, $30^{\circ}C$)를 변화시키고, 또한 유입구 형상을 아네모스형과 베인형으로 하면서 실내의 온도분포를 파악하여 열유동 특성 및 혼합특성에 대하여 고찰하였다. 연구 결과, 아네모스형이 베인형보다 혼합이 빨리 진행되었고 유입속도에 의한 영향이 기준 온도차에 의한 영향보다 지배적이었다.

  • PDF