• Title/Summary/Keyword: Room acoustic performance

Search Result 89, Processing Time 0.025 seconds

An Study on the Improvement of Acoustics Performance of the Lecture Room (대학 강의실의 음향성능 개선에 관한 연구)

  • Han, Kyeong-Yeon;Seo, Jung-Seok;Kim, Jae-Soo
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2004.11a
    • /
    • pp.361-366
    • /
    • 2004
  • This study has carried out in order to furnish the fundamental material to systemize the lecture room into multimedia in the future, by locating college lecture room as the subject of study, by compare and analyze on acoustic character in both before and after of each improvement. Thereby, now we are about to compare and analyze on physical character of room acoustics in both common lecture room before improvement and the modified multimedia-lecture room after its improvement. Observing the conclusion obtained through experiment, reverberation time in the modified 'lecture room after improvement' became shorter compare with the 'lecture room before improvement', definition and RASTI also improved to be suitable to lecture, and considered that it is able to elevate the intimacy with studying and teaching efficiency, as well.

  • PDF

A Study on Improvement Effect of voice information transmission using Auralization at the hydraulic turbine dynamo room in Dam (가청화를 이용한 댐 수차 발전기실의 음성정보전달 개선효과에 관한 연구)

  • Kook, Joung-Hun;Ju, Duck-Hoon;Jung, Eun-Jung;Kim, Jae-Soo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.263-267
    • /
    • 2007
  • Even though Waterpower Generation as pollution-free has its own merit of contribution by supply of good quality electricity, due to the noise made at the time of its operation, a normal mutual communication among the workers and technicians engaging at the hydraulic turbine dynamo room is almost impossible, and since those finishing materials had been used mainly by reflection material, it is actual situation that when working for maintenance in the hydraulic turbine dynamo room, as counterpart's voice vibrates, its working efficiency is difficult to ensure. On such view point, this Research has conducted Psycho-acoustics Experiment about voice Definition using Auralizational Technique, on the object for the hydraulic turbine dynamo room that improved its acoustic performance by computer simulation. As the result of Study, it was known that the clearness of sound with regard to voice information transmission was apparently improved in all items than before improvement. Therefore, it is considering that these results would be utilized usefully when renovation on the hydraulic turbine dynamo room in the future.

  • PDF

Acoustic Power Control of a Lightly-Damped Enclosed Sound Field

  • Kim, Woo-Young;Kim, Dong-Kyu;Hwang, Won-Gul
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.2 no.2
    • /
    • pp.19-27
    • /
    • 2001
  • This research attempts to find an active control strategy which reduces acoustic power and acoustic energy in lightly-damped enclosed sound field such as a vehicle compartment or an operating room of heavy industrial machinery. An active control strategy, which takes into consideration of the acoustic radiation power of the source as a cost function, is formulated and examined to find capability of reducing noise. An adaptive filtering algorithm for sound power control is suggested and implemented to control lightly-damped sound field. To verify the method, sound power based active noise control algorithm was implemented on a rectangular box with lightly-damped wall, and popular acoustic energy based control with modal coupling reduction was performed to compare the noise reduction performance. It was shown that a total sound power based strategy provides a practical mean for global noise reduction for lightly damped sound field.

  • PDF

New Learning Hybrid Model for Room Impulse Response Functions (새로운 학습 하이브리드 실내 충격 응답 모델)

  • Shin, Min-Cheol;Wang, Se-Myung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.23-27
    • /
    • 2007
  • Many trials have been used to model room impulse responses, all attempting to provide efficient representations of room acoustics. The traditional model designs for room impulse response seem to fail in accuracy, controllability, or computational efficiency. In time domain, a room impulse response is generally considered as the combination of three parts having different acoustic characteristics, initial time delay, early reflection, and late reverberation. This paper introduces new learning hybrid model for the room impulse response. In this proposed model, those three parts are modeled using different models with learning algorithms that determine the length or boundary of each model in the hybrid model. By the simulation with measured room impulse responses, it was examined that the performance of proposed model shows the best efficiency in views of both the parameter numbers and modeling error.

  • PDF

New Learning Hybrid Model for Room Impulse Response Functions (새로운 학습 하이브리드 실내 충격 응답 모델)

  • Shin, Min-Cheol;Wang, Se-Myung
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.18 no.3
    • /
    • pp.361-367
    • /
    • 2008
  • Many trials have been used to model room impulse responses, all attempting to provide efficient representations of room acoustics. The traditional model designs for room impulse response seem to fail in accuracy, controllability, or computational efficiency. In the time domain, room impulse responses are generally considered as combination of the three Parts having different acoustic characteristics, initial time delay, early reflection, and late reverberation. This paper introduces new learning hybrid model for room impulse responses. In this proposed model, those three parts are modeled using different models with learning algorithms that determine the boundary of each model in the hybrid model. By the simulation with measured room impulse responses, the performance of proposed model shows the best efficiency in views of computational burden and modeling error.

Measurement and Evaluation of the Acoustic Performance in the Royal Palace Buildings of Joseon Dynasty - Focused on Pyeonjeon and Chimjeon - (조선 궁궐 건축물의 음향성능 측정 및 평가 - 편전 및 침전을 중심으로 -)

  • Kim, Nam-Wook;Kim, Myung-Jun;Han, Wook
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.19 no.12
    • /
    • pp.1269-1280
    • /
    • 2009
  • This study was performed to construct sound performance DB of royal palace buildings and to examine the special quality more scientifically. Research target of royal palace were Changdeokgung and Gyeongbokgung. Sound insulation performance between the adjacent room and facade, room acoustics of Pyeonjeon and Chimjeon which is representative building in royal palace were examined through field measurement. Measured values of RT($T_{mf}$) at Pyeonjeon were 0.78 sec. and 1.03 sec. in Seonjeongjoen and Sajeongjoen, respectively. The RTs of both Pyeonjeon buildings were estimated suitable for speech and lecture considering their volume. The RT($T_{mf}$)s at Chimjeon were measured in range of 0.29~0.55 sec. This meant that the acoustic energy in rooms was decreased by sound transmission through mulberry paper(Hanji) of traditional windows and doors. As a sound insulation performance, the single-number quantities($D_{ls,2m,nT,w}$) of the building facades in Pyeonjeon and Chimjeon were measured 4~20 dB. Also the single-number quantities($D_{p,w}$) between the adjacent rooms in Chimjeon were measured 3~18 dB. Sound insulation performance of traditional building elements such as window and door depended strongly on their layers and area.

Evaluation on Reduction Effect about Noise of Hydraulic Turbine Dynamo in Dam using Auralization (가청화를 이용한 댐 수차 발전기소음의 저감효과 평가)

  • Soul, Soo-Hwan;Ju, Duck-Hoon;Kim, Jae-Soo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.6
    • /
    • pp.400-408
    • /
    • 2008
  • Multipurpose Dam, it produces electric energy by converting the potential energy into kinetic energy utilizing its head and quantity of the water. However, in this process, since during the time when the turbine connected to the hydraulic turbine generator revolves, there occurs a ceaseless loud noise, and due to this condition, it is true state that those people who work at inside of the power plant are damaging as hard as they are unable to concentrate on their work. Not only this, because the hydro-electric power generator room that locates at middle section between the hydraulic turbine room and the office is very large space volume, also since it was constructed chiefly by the reflecting material, it is functioning of amplify the noise when operating the generator, the soundproof measure against this condition is necessitated. On such viewpoint, I have presented the problem point of the relevant Hydraulic turbine dynamo and Hydraulic turbine dynamo room, and after improve such problem point, this study has ever investigated the satisfying degree about the noise-reduction at before and after of the improvement of soundproof measure, using the Auralizational technique that can experience virtual acoustic field. It is considering that such result could be utilized usefully as the fundamental material hereafter for the acoustic performance of the hydro-electric power generator room in dam and when its construction.

Case study on the Improvement of Acoustic performance for Small Multipurpose Hall (소규모 다목적 홀의 음향성능 개선 사례)

  • Ju, Duck-Hoon;Yun, Jae-Hyun;Kim, Jae-Soo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.236-241
    • /
    • 2007
  • Recently, in accordance with the cultural progress and the improvement of citizen's consciousness level, it is the real situation that the construction of small-scaled Multi-Purpose Hall where various cultural events could be performed, is on increasing. However, because the most of Multi-Purpose Hall had been designed and built up without any consideration on Acoustic Factor, many problems are on occurring thereat. Because those small-scaled Multi-Purpose Hall have been mostly used with the finishing material which contains a high degree of Acoustic Absorption indiscreetly, both diffusion and reflection of sound are not establishing properly, and since the reverberation of sound is very low, in case of musical performance by musical instrument, its sound hears too arid and stiff, there occurs some acoustic defect such as it becomes difficult for music appreciation with sufficient timbre, so that the capability improvement on the matter is urgently requiring situation. On this viewpoint, this Research has caught the Authenticity of the forecasted value and actually measured value using Acoustic Simulation on the subject of the small-scaled Multi-Purpose Hall, and then intended to propose the optimum acoustic condition on the basis of the Authenticity. As the result, it could be designed a Multi-Purpose Hall equipped with the satisfactory acoustic performance compare with the time before improvement, so that it is considered that such research result could be practically used as the fundamental material when design for other similar small-scaled Multi-Purpose Hall in the future.

  • PDF

Audiometric Calibration of Aural Acoustic Immittance Instrument: A Review of Acoustic Immittance Instrument's Calibration

  • Kim, Jin-Dong
    • Biomedical Science Letters
    • /
    • v.22 no.4
    • /
    • pp.115-126
    • /
    • 2016
  • Audiometric calibration is a prerequisite for securing the reliability of audiometric test results by checking the internal consistency of the relevant instrument. The purpose of this review is to help instrument operators understand the calibration procedure of aural acoustic immittance instrument which is frequently used for objective assessment. By referring to the latest international standards and the national standards relevant to the aural acoustic immittance instrument, the following parameters will be reviewed: 1) introduction of performance characteristics, 2) detailed procedure of the calibration method. According to the newest international and national standards [IEC 60645-5 (2004), ANSI S3.39-1987 (R2012)], the aural acoustic immittance instrument basically includes six components: 1) calibration cavity, 2) acoustic immittance analysis system, 3) probe assembly/unit and signal, 4) pneumatic air-pressure pump system, 5) acoustic reflex activator system and 6) tympanogram and acoustic reflex plotting system, each of these components should meet set standards. The result of behavioral hearing tests is influenced by various complex factors including the examinee's cooperation, background noise of the examination room, measurement method, skill level of the audiologist and calibration status, but the objective hearing tests is more influenced by the calibration status of the instrument than any other factors. The audiologist should take full responsibility for the reliability of the hearing test result, so he/she should carry out the calibration check and adjustments of aural acoustic immittance instrument periodically and maintain the instrument continuously by referring to the newest standards and the manufacturer's instruction manual.