• 제목/요약/키워드: Room Control

검색결과 1,975건 처리시간 0.027초

응급의료센터 감염예방을 위한 동선분리를 고려한 평면계획 연구 (Infection Control through Emergency Room Layout)

  • 김중기;서현보
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제26권1호
    • /
    • pp.7-15
    • /
    • 2020
  • Purpose: Emergency room(ER) is the first place to enter a hospital where patients who might have been infected with contagious disease. Therefore, ER should be designed with infection control in mind. Researchers examined hospital ER layouts to identify layout design that support infection control. Methods: This study analyzed the hospital ER layout of Korean and other hospitals abroad. Researchers focused on route of incoming patients who potentially have infectious disease. Crossing of this route with other routes such as for imaging and testing should be avoided for infection control. Results: There were certain hospital ERs with better control of infection related incidents. ER floor plan layout is analyzed about allocation of key functions with movement routes for each role such as patients and medical staff in mind. To identify layout strategies for ER functions researchers simplified the routes in ER into diagrams. Layout options show that bypassing infection suspected routes over other routes is possible. Implications: Hospitals can control infection easier when they adopt strategic ER layout identified in this study.

냉난방 시스템의 이중선형 시스템에 관한 제어기 설계 (A Controller Design of the Bilinear System for HVAC(Heating, Ventilating and Air-conditioning) System)

  • 이정석;강민수;김명호;이기서
    • 한국철도학회논문집
    • /
    • 제3권4호
    • /
    • pp.177-184
    • /
    • 2000
  • In this paper, a HVAC controller which has a bilinear system is designed to control the air temperature in building room and a saving of energy on the HVAC system. For modeling of the HVAC bilinear system, AHU(Air Handling Unit) is modeled on the control of inside-outside air flow using three dampers in a duct. A heat exchanger and the single room are also modeled by the energy conservation law. Under the modeling of the HVAC bilinear system, the control's law of the bilinear HVAC system is derived by Lyapunov's non-linear theory and Deress's the linear feedback laws for bilinear system. In this paper it was proved that the controller of the HVAC bilinear system is able to control the air temperature with a disturbance in order to get a target of temperature in the building room by the computer simulation when the control inputs regulate the air flow rate and a capacity of the heat exchanger.

  • PDF

핵의학 검사실내 세균 분석 (Analysis of the Bacteria in Nuclear Medicine)

  • 신성규;이효영
    • 대한안전경영과학회지
    • /
    • 제19권2호
    • /
    • pp.95-100
    • /
    • 2017
  • In this study, the bacterial contamination level of equipments and devices in the nuclear medicine department of a university hospital was investigated. CNS was detected from the sample collected from the door opening button of the nuclear medicine department. Bacillus sp. was detected from the table and CNS with Bacillus sp. were detected from the control button at the PET-CT room no.1. Also, CNS was detected from the table and the control button at the PET-CT room no.2. In the distribution room no.1, CNS and Bacillus sp. were detected while CNS being detected from the distribution room no.2 and CNS with Bacillus sp. being detected from the distribution room no.3. In the injection room, Enterrococcus faecium and Pontoea sp. were detected. On the table of the ecsomatics room, Pontoea sp. was detected. Bacillus sp. was detected from the inside of the syringe Pb shield and CNS was detected from the outside. Enterrococcus faecium was detected from the Gamma camera table and Bacillus sp. was detected from the door grip. On the chair at the patient waiting room, Pseudomonas aeruginosa abd Bacillus sp. were detected. Therefore, it was understood that infection should be prevented by securely sterilizing examination devices after each examination, maintaining cleanliness by regular sterilization of waiting chairs and such objects with a number of direct contacts with patients, and infection education for the features of nuclear department.

레몬얼음과 생수얼음을 이용한 구강간호가 비강수술 환자의 갈증 및 구강상태에 미치는 효과 비교 (Comparison of the Effects of Lemon Ice and Water Ice on Decreasing Thirst of the Patients with Nasal Surgery)

  • 정현주;윤지영;박지은;심인숙;김운정;이주희;이미란;이금남
    • 임상간호연구
    • /
    • 제18권2호
    • /
    • pp.196-204
    • /
    • 2012
  • Purpose: This study was aimed to compare the effects of lemon ice and water ice on decreasing thirst of the patients with nasal surgery. Methods: A nonequivalent control group non-synchronized design was used for the study. The level of thirst and oral assessment were measured. A total of 60 subjects was recruited; 30 subjects for the experimental group in which lemon ice was provided and the other 30 subjects were in the control group in which on water ice was administered. Results: The scores of thirst were decreased in both lemon ice and water ice group. But it appeared that the score of thirst in the experimental group is significantly lower than that of the control group. Moreover, the score of the assessment of the patient's oral cavity was also significantly improved in the experimental group than that of the control group. Conclusion: The lemon ice seems an effective and easy-to-apply intervention in reducing thirst and mouth dryness over water ice in nursing practice.

무부하 압축기에 의한 냉장고 기계실 소음의 능동제어 (Active Control of Noise Transmitted through Ventilation Openings of the Machinery Room of Refrigerator)

  • 구정모;정의봉;김태훈;홍진숙
    • 한국소음진동공학회논문집
    • /
    • 제26권4호
    • /
    • pp.475-482
    • /
    • 2016
  • The active control of noise generated by the compressor and transmitted out of the machine room through the windows is implemented based on the FIR filter. The machine room contains most of noise sources of electric home appliances, air-conditioners and refrigerators, for example. To actively reduce the noise from the machinery room. In this paper, the transfer function of the controller for minimization of the acoustic power transmitted through the windows is mathematically formulated. The transfer functions required for implementation of the active controller are the measured. The measurements are conducted in this initial stage under the operation of the compressor with no load. For improvement of the reliability of the transfer function of the compressor to the acoustic power, additional operational measurements are performed. The real time controller is implemented based on the FIR filter using the measured transfer functions and the performance of the active controller is estimated. Control performance is measured about 3 dB ~ 10 dB in reduction of the sound power at the peaks of the compressor noise.

IMPROVING THE SPEECH INTELLIGIBILITY IN AN AIR-TRFFIC CONTROL ROOM

  • Pavuza, Franz G.;Beszedics, Geza W.;Pichler, Heinrich
    • 한국음향학회:학술대회논문집
    • /
    • 한국음향학회 1994년도 FIFTH WESTERN PACIFIC REGIONAL ACOUSTICS CONFERENCE SEOUL KOREA
    • /
    • pp.912-918
    • /
    • 1994
  • Poor speech intelligibility in an air traffic control room is frequently a result of many, quite different causes and occasionally leads to complaints of the controller personnel. The paper describes a sequence of successful tasks performed in a local control room. The initial measurements included an investigation of the background noise (caused by fans, air condition, computer and radar equipment) and performance checks of the electronic audio and communication equipment with respect to the audio transmission behavior. The spectral composition of the noise as well as the characteristics of the audio communication path between the controllers and the pilots(which showed a loss of spectral information in the audio band due to built-in notch filters for the suppression of control tones) required adaptations of the amplitude behavior of the amplifiers through user adjustable tone controls. The radar console fans, which contributed significantly to the overall noise floor of the room, underwent a substantial reconstruction by replacing the tight mounting with an elastic double suspension, reducing the noise level by 50%. Finally, a possible source of untimely fatigue of the controllers during their working hours has been found in strong spectral components of the noise above the audio band, radiated by numerous video monitors in the control through vibrating components excited by the line frequency of the video signal.

  • PDF

슬래브축열의 최적제어방책에 관한 연구 -평가요소로 복사열의 고려 유무에 의한 차이- (A Study on the Optimal Control Strategy of Air-Conditioning System with Slab Thermal Storage - The Difference by the Presence of Radiant Heat as a Criterion Factor -)

  • 정재훈;신영기
    • 설비공학논문집
    • /
    • 제18권4호
    • /
    • pp.287-296
    • /
    • 2006
  • In this paper, optimal control strategy of the air-conditioning system with slab thermal storage was investigated based on the optimal control theory. An optimal heat output to the plenum chamber and the air-conditioned room was determined based on two kinds of criterion functions. The first one requires small deviation in room air temperature from a set-point value and low energy consumption. It is shown that the optimized control is to store heat through the whole storage time and to increase storage rate gradually with time. As the second case, a criterion that both a deviation of operative temperature from a set-point temperature and the energy consumption should be minimized was adopted. The room air temperature was a little high and the cooling load during storage time was reduced, compared with the results when a criterion function considering only the room air temperature is used.

The evolution of the Human Systems and Simulation Laboratory in nuclear power research

  • Anna Hall;Jeffrey C. Joe;Tina M. Miyake;Ronald L. Boring
    • Nuclear Engineering and Technology
    • /
    • 제55권3호
    • /
    • pp.801-813
    • /
    • 2023
  • The events at Three Mile Island in the United States brought about fundamental changes in the ways that simulation would be used in nuclear operations. The need for research simulators was identified to scientifically study human-centered risk and make recommendations for process control system designs. This paper documents the human factors research conducted at the Human Systems and Simulation Laboratory (HSSL) since its inception in 2010 at Idaho National Laboratory. The facility's primary purposes are to provide support to utilities for system upgrades and to validate modernized control room concepts. In the last decade, however, as nuclear industry needs have evolved, so too have the purposes of the HSSL. Thus, beyond control room modernization, human factors researchers have evaluated the security of nuclear infrastructure from cyber adversaries and evaluated human-in-the-loop simulations for joint operations with an integrated hydrogen generation plant. Lastly, our review presents research using human reliability analysis techniques with data collected from HSSL-based studies and concludes with potential future directions for the HSSL, including severe accident management and advanced control room technologies.

A Preliminary Study on the Communication Effect on Team Performance in Main Control Room of SMART

  • Heo, Eun Mee;Byun, Seong Nam
    • 대한인간공학회지
    • /
    • 제32권1호
    • /
    • pp.97-106
    • /
    • 2013
  • Objective: The aim of this study is to investigate the attributing factors influencing team performance. Background: Technically, it is necessary that operators adapt themselves to computerized and advanced techniques to operate the main control rooms safely in nuclear power plant in Korea. The more main control rooms are digitalized, the more important for operators to have high team performance it is. Method: This paper analyzes team process through literatures review and elicits team performance shaping factor. Especially, the objective of this research is to elicit communication using common team performance shaping factors. Results: This study has found communication through team performance shaping factors in Main Control Room of the SMART. Conclusion: This paper can offer a starting point for team communication, which can use team performance shaping factor framework that are emerging in these new nuclear power plant. Application: As a result, I expect that the evaluation communication for MCR operator's team performance will lead the operating techniques in nuclear power industry internationally.

PMV 제어에 따른 사무소 건물의 실내열환경과 에너지소비량 분석 (Analysis of Indoor Thermal Environment and Energy Consumption in Office Building Controlled by PMV)

  • 장향인;서승직
    • 한국태양에너지학회 논문집
    • /
    • 제33권4호
    • /
    • pp.15-22
    • /
    • 2013
  • The purpose of this study is to analyse the effects of air conditioned room controlled by PMV(Predicted Mean Vote)for energy consumption and human comfort in office building. The 'EnergyPlus' was used for the evaluation of indoor thermal environment and energy consumption by the controls of room temperature and PMV. The result indicates that the PMV control could prove more profitable method for improvement of indoor thermal environment and energy conservation. Consequently, PMV control has a distinct advantage over most other control methods. An additional study is required to establish the various thermal comfort control for rooms on the basis of this work.