원형 석굴암 상부구조의 장마철 결로 및 열전달 현상의 실험적 연구 (Experimental investigation of dew formation and heat transfer in the original upper structure of Sokkuram grotto)

  • 이진기;송태호
    • 설비공학논문집
    • /
    • 제11권5호
    • /
    • pp.588-597
    • /
    • 1999
  • Sokkuram grotto, a UNESCO cultural heritage in Kyongju Korea, was originally covered with crushed rocks over its dome with ventilating holes. The grotto was perfectly preserved for more than 12 centuries until the upper structure was replaced with a concrete dome in the early 20th century to protect from total collapse. Since then, heavy dew formed on the granite surface to seriously damage the sculptures until it was further remodeled with air-conditioning facilities in the 60s. It is considered that the original upper porous structure had a dehumidifying capability. This research is made to unveil the dehumidifying mechanism of the rock layer during the rainy season in that area. A rock layer and a concrete layer are tested in a temperature/humidity-controlled room. No dew formation is observed for the two specimen for continued sunny days or continued rainy days. However, heavy dew formed on the concrete surface for a sunny day after long rainy days. It is thought that the sun evaporates water on the ground and dew is formed at the surface as the highly humid air touches the yet cold concrete. On the contrary, no dew formation is observed for the rock layer at any time. Even in the above worst situation, air flows downward through the cool rock layer and moisture is removed before reaching inside. Temperature measurement, flow visualization, observation of dew formation and measurement of air velocity are made to verify the mechanisms.

  • PDF

공기순환구조를 갖는 축열지붕의 열전달해석 (Analysis of Heat Transfer of Thermal Storage Roof with the Air Circulation System)

  • 신우철;박석현;백남춘
    • 한국태양에너지학회 논문집
    • /
    • 제21권1호
    • /
    • pp.33-42
    • /
    • 2001
  • The paper discusses the modelling of the thermal storage roof with the air circulation system. In this system, the fully glazed absorber plate is put on the top of the conventional pitch roof made of massive concrete and acts as a solar air heater. Solar radiation collected into absorber is stored in the roof structure by radiation and convection so that it reduces the nighttime heating load through the roof. Another part of the energy is also transmitted to internal air drawn into the channel and is then introduced Into the room. To analysis the system, the energy balance equations are developed and are solved using a finite difference method. The calculation results show a good agreement with the measured ones obtained from our experiments. From the results, it is seen that the thermal storage roof with the air circulation system reduces significantly the conductive heat loss compared with that for the conventional roof and has the instantaneous solar collection efficiency of about 30%.

  • PDF

HVAC 상실사고시 울진원전 3/4 호기의 보조급수펌프 격실 온동상승 평가 (Heat-up Calculation for the Auxiliary Feed Water Pump Room at Ulchin Units 3 and 4 for Loss of HVAC Accidents)

  • 윤철;박진희;황미정;한상훈
    • 대한기계학회논문집B
    • /
    • 제36권5호
    • /
    • pp.553-562
    • /
    • 2012
  • 난방, 환기 및 공기조절(HVAC) 기능이 상실된 사고의 경우, 보조급수를 위한 모터-구동 펌프격실의 온도상승을 전산유체역학 분석을 통해 평가하였다. 닫힌 펌프격실의 과도 계산결과, 8 시간 동안 공간-평균된 공기온도는 $60^{\circ}C$ 정도의 상승이 예상된다. 외기 온도 및 외부 온도는 이전 계산결과로부터 초기 $35^{\circ}C$에서 시작하여 서서히 증가한다고 가정하였다. 격실 문이 사고발생 후 약 2, 4, 그리고 6시간 경과 시점에서 열릴 경우, 체적-평균 격실 내가 온도는 약 $4^{\circ}C$의 즉각적인 하강이 나타나며 이후 서서히 온도가 상승하는 장기 거동을 보인다. 전산유체역학을 적용한 현재의 상세 해석결과는 이전의 집중(lumped) 모델을 사용한 보수적인 계산결과에 비해 낮은 격실온도 상승률을 예측한다.

천장형 실내기의 기류 가시화를 통한 최적 제어 설계 (Design of Optimal Vane Control for Ceiling Type Indoor Unit by PIV measurements)

  • 성재용;안광엽;이기섭;최호선;박승철;이인섭
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2002년도 학술대회지
    • /
    • pp.533-536
    • /
    • 2002
  • A heating flow discharged from a 4-way ceiling type indoor unit has been investigated using a PIV(particle image velocimetry) system For the PIV measurements, an experimental model of 1/10 scale with a transparent room was devised by satisfying the Archimedes number, which is generally used in case that the forced convection has the similar magnitude as the natural convection. To optimize the heating flow, several vane angles and vane control algorithms of cross and right angle controls were considered. Regarding the vane angle, the experimental results show that it should be less than $30^{\circ}$ to avoid re-suction flows which decrease the performance of the air-conditioner. At the vane angle of $30^{\circ}$, applying open/close control gives nae to more uniform distribution of the heating flow than without control. Especially, the cross-control seems to be satisfactory for the thermal comfort.

  • PDF

화재실내 자연대류의 수치해석 (Numerical Analysis of Natural Convection in Room Fire)

  • 정길순;이승만;이병곤
    • 한국화재소방학회논문지
    • /
    • 제19권4호
    • /
    • pp.18-25
    • /
    • 2005
  • 자연대류유동 형태의 실내화재 해석은 Zone 모델과 Field 모델로 대별된다. Zone 모델은 화염과 연소가스로 인한 상부의 고온 연기층과 하부의 찬 공기층의 온도를 균일하게 간주하고, 실험값을 대입한 간단한 대수식으로 계산하여 간편하나 각각의 위치에 대한 온도와 유속 등을 구할 수 없다. Field모델은 해석영역을 다수의 격자로 구성하고 운동량, 에너지방정식 등을 수치해석하는 방법으로 많은 계산시간 및 컴퓨터 용량이 필요하나 각각의 위치에서의 유동 및 온도분포 등을 자세히 규명 할 수 있다. 열유동 수치해석에는 기존의 상용 프로그램들이 있어 강제대류에는 잘 적용되나, 자연대류에는 대부분 만족할 만한 결과를 주지 못하고 있다. 이에 본 연구에서는 실내화재해석의 기초연구로, 바닥면이 부분적으로 가열될 때 우측벽의 경계조건을 변화시켜 가면서 실내의 층류 자연대류로 인한 유동장과 온도장을 SIMPLE 수치해석방법을 이용하여 직접 수치해석 하였다.

블라인드 설치 위치에 따른 실내열환경 변화에 관한 연구 (A Study on the Change of Indoor Thermal Environment According to the location of Blinds)

  • 황덕수;이경희
    • 한국태양에너지학회 논문집
    • /
    • 제31권5호
    • /
    • pp.113-118
    • /
    • 2011
  • In order to prevent incoming solar radiation, it is necessary to study about blinds' blocking out effects of heat that are installed at the balcony at an apartment house. To figure out the heating effects from the windows, a study for indoor thermal environment according to the location of blinds is also needed. In order to find out the changes of indoor thermal environment, we'll compare models of a house building with or without Venetian blinds: one place has an extended living room removing a balcony and another one has a normal balcony. The result is as follows. Without blinds, the place with an extended living room has benefits for saving heat compare to the place with a normal balcony. It's because the warm air heated by the incoming solar radiation moves into the living room through convection current and radiation which causes an increase of the indoor temperature. At an extended living room, the temperature difference from outside and inside, when blinds were installed inside, was $1.9^{\circ}C$ while it was $0.6^{\circ}C$ when the blinds were installed at outside of the balcony. It is evaluated that setting up the blind outside prevents much heat. At the space with a normal balcony, installing blinds at living room windows can save much heat compare to installing blinds at windows at the balcony. The indoor temperature was low when blinds were installed. It can be said that blinds block heat from the incoming solar radiation. Moreover, when blinds are installed, there is a big change of indoor temperature due to the radiation from the blinds' slat and convective activities in between the blinds and windows. This also has to be considered.

냉각된 복사천장패널의 열전달 특성에 관한 연구 (A Study on the Heat Transfer Characteristics of the Radiant Chilled Ceiling Panel for Space Cooling)

  • 이태원;황인주
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집D
    • /
    • pp.164-169
    • /
    • 2001
  • There is a chilled ceiling panel which carries out the air conditioning by radiation and convection between the room and cold ceiling panel surface. In order to verify heat transfer characteristics between them in cooling system with radiant chilled ceiling panel, analytical and experimental studies were performed for various design and operating parameters such as tube space and diameter, inlet water temperature, mass flow rate, cooling load, and so on. In this study, we found that the tube space and inlet water temperature were more important elements than the tube diameter and water flow rate for the performance of radiant chilled ceiling panel. The cooling capacity of the radiant chilled ceiling panel had the maximum value of $65W/m^{2}$ because the highest cooling capacity was limited by the condensation on the panel surface. The results of comparison between numerical analysis and experiment showed a resonable agreement qualitatively, especially for low cooling capacity.

  • PDF

T-history법에 의한 저온 PCM 잠열측정의 정밀도 향상 (Improving the Precision for the T-history Method for Latent Heat Measurements of Low Melting Temperature PCMs)

  • 이윤석;백종현;강채동;홍희기
    • 설비공학논문집
    • /
    • 제17권3호
    • /
    • pp.223-231
    • /
    • 2005
  • When test tubes for PCM with melting point lower than a room temperature are installed vertically as the T-history method proposes, there exists a temperature distribution in the longitudinal direction by natural convection, which lowers the precision of measured heat-of-fusion. The purpose of the present work is to improve the precision by arranging the test tubes horizontally, while maintaining the simplicity and convenience. Assuming that the amount of heat transfer is very small through the vapor space formed in the upper part of the tubes by volumetric change, the obtained value by the T-history method using the latent heat period bounded by two inflection points is in good agreement with that of the literature. Also, the scattering of measured values by the proposed method decreases markedly compared to that of vertical positioning.

지하수 이용을 위한 열교환기 개발. II - 지하수이용 냉·난방기 설계제작 - (Development of heat exchanger for underground water heat. II - Design and manufacture for heat exchanger of underground water -)

  • 이운용;안덕현;김상철;박우풍;강용구;김선배
    • 현장농수산연구지
    • /
    • 제4권1호
    • /
    • pp.128-137
    • /
    • 2002
  • 개발된 알루히트를 이용하여 지하수 이용 열교환기를 개발하였다. 시작기는 600mm, 700mm 알루히트 19개의 끝을 U자 용접을 하여 지하수가 직렬흐름이 되도록 2가지로 제작하였다. 성능시험은 개방된 공간에서 지하수 유량과 공기양의 변화를 주면서 상온에서 실시하였다. 1. 시작기의 열전달 계수는 33~156(W/m2℃) 범위로 나타나 설계가정 값에 잘 일치하는 것으로 판단되었다. 2. 열전달 면적이 증가할수록, 지하수 입·출구의 온도 차이가 클수록, 공기의 입·출구 온도 차이가 클수록, 또 송풍량이 증가할수록 에너지 전달량이 증가하였다. 3. 지하수 입·출구 온도 차이가 6℃ 이고 송풍량이 6,000m3/h일 때 전달 열용량은 6,825W였으며, 공기의 입·출구 온도 차이는 25.8℃에서 23.2℃로 -2.6℃의 강화 효과가 있었고, 대류열전달계수는 88.5W/m2℃ 였다. 4. 지하수 입·출구 온도 차이가 2℃ 이고 송풍량이 4,000m3/h일 때 전달 열용량은 2,625W으로 작았지만, 공기의 입·출구 온도 차이는 27℃에서 22.5℃로 -4.5℃의 강화 효과가 있었고, 대류열전달계수는 33.6W/m2℃였다. 5. 시작기 I, II, III의 전달 열용량 데이터 각각의 상관계수 R2은 0.9141, 0.8935, 0.9393이었으며, 공기유량이 6,000m3/h, 5,000m3/h, 4,000m3/h일 때 각각의 데이터 상관계수 R2은 0.9513, 0.9414, 0.9003으로 신뢰할 수 있었다.

가습 입자를 활용한 고효율 난방 시스템 개발 (Development of high-efficiency heating system using humidifying particles)

  • 이정원;홍경보
    • Design & Manufacturing
    • /
    • 제14권4호
    • /
    • pp.17-24
    • /
    • 2020
  • Products for heating indoors in low temperature and dry winter are largely divided into products using fossil fuels and products using electricity. The fossil fuels can warm the entire space by convection, but there is a high risk of fire and the frequent ventilation due to the increase in carbon monoxide and carbon dioxide. Heaters using electricity are mainly used because they are convenient to use and are cheap. However, these products can not efficiently warm the air because they use radiation energy. In other words, only the front part exposed to the heater is warm, and the rear part has no heating effect at all. Also, because it emits a large amount of light, fatigue of the eyes is very high. Another problem is that when using electric heaters, the room tends to be dry by high heat. Indoor humidity maintenance is a very important factor in the prevention and treatment of respiratory diseases. Especially, it is essential for health care for infants, bronchial organs and people with weak respiratory because humidity is low in winter. In this study, we conducted a study to develop a product that can improve heating efficiency while maintaining proper indoor humidity by combining heat energy and moisture particles. The concept of humidification and heating at the same time, moisture particles generated in the humidifier pass through the heater, include thermal energy, and the moisture particles with thermal energy are diffused into the space by forced convection, thereby warming the entire space. In addition, the heating time is shortened as the feeling temperature is increased with the high relative humidity, and this has the effect that the heating cost in winter is reduced.