Wind uplift rating of roofing systems is based on standardised test methods. Roof specimens are placed in an apparatus with specified table size (length and width) then subjected to the required wind load cycle. Currently, there is no consensus on the table size to be used by these testing protocols in spite of the fact that a table size plays a significant role in evaluating the performance. This paper presents a study with the objective to investigate the impact of table size on the performance of roofing systems. To achieve this purpose, extensive numerical experiments using the finite element method have been conducted to investigate the performance of roofing systems subjected to wind uplift pressures. Numerical results were compared with results obtained from experimental work to benchmark the numerical modeling. Required table size and curves for the determinations of appropriate correction factors are suggested. This has been completed for various test configurations with thermoplastic waterproofing membranes. Development of correction factors for assemblies with thermoset and modified bituminous membranes are in progress. Generalization of the correction factors and its usage for wind uplift rating of roofs will be the focus of a future paper.
This paper analyse the mechanical characteristics of geometrical and material nonlinearity behavior of cylindrical shell roofs subjected to a concentrated load. The shell elements were modeled using 'NISA2016' software as 3D general shell element and 3D composite shell element. The 3D shell element includes deformation due to bending, membrane, membrane-bending coupling and shear perpendicular to the grain effects is suited for modeling moderately thick or thin general shells and laminated composite shells. And The 3D composite shell element consists of a number of layers of perfectly bonded anisotropic and orthotropic materials. The purpose of this research is to analysis the load-deflection curves considering the combined geometric and material nonlinearity of cylindrical shells. In a shallowed cylindrical shell, snap-through curve can be found.
This study aims to accurately predict the first ply failure loads of laminated composite hypar shell roofs with different boundary conditions. The geometrically nonlinear finite element method (FEM) is used to analyse different symmetric and anti-symmetric, cross and angle ply shells. The first ply failure loads are obtained through different well-established failure criteria including Puck's criterion along with the serviceability criterion of deflection. The close agreement of the published and present results for different validation problems proves the correctness of the finite element model used in the present study. The effects of edge conditions on first ply failure behavior are discussed critically from practical engineering point of view. Factor of safety values and failure zones are also reported to suggest design and non-destructive monitoring guidelines to practicing engineers. Apart from these, the present study indicates the rank wise relative performances of different shell options. The study establishes that the angle ply laminates in general perform better than the cross ply ones. Among the stacking sequences considered here, three layered symmetric angle ply laminates offer the highest first ply failure load. The probable failure zones on the different shell surfaces, identified in this paper, are the areas where non-destructive health monitoring may be restricted to. The contributions made through this paper are expected to serve as important design aids to engineers engaged in composite hypar shell design and construction.
본 연구는 부석사 무량수전의 측면 지붕부 결구 구조에 관한 연구이다. 부석사 무량수전은 일제시대에 해체 보수한 기록이 있으며, 팔작지붕의 측면 지붕부 결구 구조기법과 추녀, 귀서까래 등의 결합 수법들이 정연한 형태로 결구되지 않고, 조선시대 팔작지붕의 측면 지붕부 결구구조와 이질적인 요소가 많아 원형이 아닌 것으로 끊임없이 제기되어 왔다. 또한, 그 편년에 대해 다양한 의견(13세기, 12세기 건축)들이 국내외 학자들에 의해 제시되어 왔었다. 본 연구는 동아시아 목조건축 구조틀이라는 관점에 근거하여, 중국 당 송대 팔작지붕에서 부석사 무량수전과 측면 지붕부 결구구조 기법과 유사한 건축을 대상으로 평면비 및 어칸과 퇴칸의 비례를 상호 비교하여 살펴 본 결과 부석사 무량수전의 측면 지붕부 결구구조는 팔작지붕에서도 볼 수 있는 기법으로 판단하였다. 부석사 무량수전처럼 측면 서까래가 내부 보(량(梁))에 직접 접하는 기법은 중국 당 송대 팔작지붕 건축에서도 흔하게 볼 수 없는 수법으로, 중국의 팔작지붕은 당대(唐代) 이후에 산화(山花, 합각) 양가(梁架)를 구성하여 팔작지붕의 측면을 구성하는 기법이 발달되어, 명청대 이전까지 크게 발전된 것으로 보인다. 또한 귀서까래의 발달과정 중 평행서까래에서 말굽서까래로 전환되기 이전 방식인 평행복사연(平行輻射椽)이 현재 부석사 무량수전의 귀서까래 방식과 유사한 것으로 보인다. 다만, 추녀의 중간부분부터 귀서까래가 걸치지 않는 부석사 무량수전의 방식은 중국에서도 현재까지 확인되지 않은 방식으로 부석사 무량수전의 특성으로 보인다. 이런 기법들을 살펴본 결과 부석사 무량수전의 측면 지붕부 결구구조는 중국 남방지역에서는 볼 수 없으며, 북방 지역의 당 송대(唐 宋代) 및 요대(遼代) 시기에 볼 수 있는 기법으로, 건축물의 편년시기와 평면에서 어칸과 퇴칸의 비례 관계를 고려해볼 때 동아시아 북방지역에서 볼 수 있는 고식(古式)의 구조 기법으로 판단된다. 부석사 무량수전의 측면 지붕부 결구구조가 변형된 것이 아니고, 팔작지붕 고유의 방식일 가능성이 있는 만큼 향후 부석사 무량 수전의 평면과 어칸 및 퇴칸의 비례, 측면 지붕부 결구구조를 중심으로 고려시대 이전 폐사지 중 팔작지붕으로 추정되는 건물의 측면 지붕부 결구구조에 대해 복원 설계에 좋은 참고가 될 것으로 보인다.
2017년 실시한 경주 고선사지 삼층석탑의 정밀안전진단 과정에서 1975년 석탑 이전 시 2층 탑신석이 회전되었을 가능성이 제기되었다. 이에 일제강점기와 1975년 해체 전후의 관련정보와 사진자료 등을 수집하여 석탑부재에 대한 정밀조사를 진행하였다. 분석결과 1943년 개건 전·후에는 부재의 변동이 없었으나 1975년 이전과정에서 2층 탑신석이 오른쪽 방향으로 90도씩 회전하였고, 1층과 2층의 옥개석 1매가 서로 바뀌었음이 확인되었다. 이러한 석탑부재의 변동이 오류인지를 확인하기 위해 3차원 스캐닝 정보를 토대로 정밀계측과 옥개석 부재의 재구성 등을 통해 검증해 보았다. 검증결과 현재 1층 옥개석 4매의 두께는 75~76cm, 2층은 78~79cm로 특이점이 발견되지 않았고, 옥개석 간 연접선의 형상 역시 자연스러웠다. 이에 고선사탑은 조성이후부터 1943년 사이에 중수(重修)된 숨은 연혁이 존재하며, 고대에 발생한 오류를 1975년 바로잡은 것이라고 결론지었다. 아울러, 2층 탑신석의 회전은 옥개석 위치변동에 따른 부수적 조치일 가능성을 제시하였다.
본 연구는 도시 열환경 문제를 개선하기 위해 UAV 영상 표면온도 자료를 이용하여 피복재질별 표면온도 특성을 분석하였다. 그리고 UAV 영상 표면온도를 유사한 시기에 측정된 현장 실측 표면온도와 비교하였다. UAV 영상과 실측 표면온도와 비교한 결과, 가장 큰 차이를 보이는 피복재질은 회색 콘크리트 지붕 재질로 약 $7.8^{\circ}C$로 나타났다. 우레탄은 $0.3^{\circ}C$ 차이로 가장 적었다. 산점도를 분석한 결과 설명력이 63.75%로 상관성이 높은 것으로 분석되었다. 표면온도가 가장 높은 재질은 금속지붕으로 $48.9^{\circ}C$로 나타났고, 우레탄($43.4^{\circ}C$), 회색 콘크리트 지붕($42.9^{\circ}C$) 순이었다. 표면온도가 낮은 재질은 나지($30.2^{\circ}C$), 수목 및 잔디($30.2^{\circ}C$), 흰색 콘크리트 지붕($34.9^{\circ}C$)이었다. UAV 영상 표면온도 자료는 피복재질의 열적특성을 정밀하게 분석 가능하였다. 향후, 실측자료와의 비교를 통해 UAV 영상의 정확성 검 보정과 위성영상과 연계하여 UAV 영상 자료의 활용성을 확대할 필요가 있다.
This study was carried out to investigate the changes of plant species and soil physicochemical properties on green roofs established at Seoul Women's University in 2005, 2006 and 2007. The plant species and soil properties were investigated in 2013. The areas of green roof sites ranged $90{\sim}100m^2$. There were floras of vascular plants of 12 families, 20 genera and 22 species in the 2005 site, 24 families, 37 genera and 38 species in the 2006 site, 14 families, 27 genera and 31 species in the 2007 site. The total number of plant species decreased in the 2005 and 2006 sites and increased in the 2007 site since established. High proportion of dispersal type was barochory in the 2005 and 2006 site, and autochory in the 2007 site. And the proportion of the compositae family was high in the introduced plants over the sites for the all study sites. Average pH and organic matter concentration of green roof soil were ranged from 5.25 to 5.96 and 7.17 to 8.96% in study sites. The organic matter concentration and pH of green roof soil were lower in 2013 than in the three establishment years. Carbon concentration of green roof soil in the three study sites were ranged from 4.16 to 5.30% and total soil carbon in 10cm depth were ranged form 1.57 to $1.98kg/m^2$.
Recent major post-hurricane damage assessments in the United States have reported that the most common damages result from the loss of building roof coverings and subsequent wind driven rain intrusion. In an effort to look further into this problem, this paper presents a full-scale (Wall of Wind --WoW--) investigation of external and underneath wind pressures on roof tiles installed on a low-rise building model with various gable roofs. The optimal dimensions for the low-rise building that was tested with the WOW are 2.74 m (9 ft) long, 2.13 m (7 ft) wide, and 2.13 m (7 ft) high. The building is tested with interchangeable gable roofs at three different slopes (2:12; 5:12 and 7:12). The field tiles of these gable roofs are considered with three different tile profiles namely high (HP), medium (MP), and low profiles (LP) in accordance with Florida practice. For the ridge, two different types namely rounded and three-sided tiles were considered. The effect of weather block on the "underneath" pressure that develops between the tiles and the roof deck was also examined. These tests revealed the following: high pressure coefficients for the ridge tile compared to the field tiles, including those located at the corners; considerably higher pressure on the gable end ridge tiles compared to ridge tiles at the middle of the ridge line; and marginally higher pressure on barrel type tiles compared to the three-sided ridge tiles. The weather blocking of clay tiles, while useful in preventing water intrusion, it doesn't have significant effect on the wind loads of the field tiles. The case with weather blocking produces positive mean underneath pressure on the field tiles on the windward side thus reducing the net pressures on the windward surface of the roof. On the leeward side, reductions in net pressure to a non-significant level were observed due to the opposite direction of the internal and external pressures. The effect of the weather blocking on the external pressure on the ridge tile was negligible.
Null designs form a vector space and there are only finite number of minimal null designs(up to scalar multiple), hence it is natural to look at the convex polytopes of minimal null designs. For example, when t = 0, k = 1, the convex polytope of minimal null designs is the polytope of roofs of type An. In this article, we look at the convex polytopes of minimal null designs and find many general properties on the vertices, edges, dimension, and some structural properties that might help to understand the structure of polytopes for big n, t through the structure of smaller n, t.
This paper presents results of fire tests on corrugated sheets used as load bearing structure of roofs of industrial buildings. Additional tests of bolted sheet connections to the supporting structure at ambient and elevated temperatures are described. Three connection types were tested and their resistance, stiffness and deformation capacity was evaluated. Finite element simulations of the corrugated sheet based on the experimental observations are briefly described and design models are presented.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.