• 제목/요약/키워드: Roof span

검색결과 132건 처리시간 0.024초

Nonlinear stability analysis of a radially retractable hybrid grid shell in the closed position

  • Cai, Jianguo;Zhang, Qian;Jiang, Youbao;Xu, Yixiang;Feng, Jian;Deng, Xiaowei
    • Steel and Composite Structures
    • /
    • 제24권3호
    • /
    • pp.287-296
    • /
    • 2017
  • The buckling capacity of a radially retractable hybrid grid shell in the closed position was investigated in this paper. The geometrically non-linear elastic buckling and elasto-plastic buckling analyses of the hybrid structure were carried out. A parametric study was done to investigate the effects rise-to-span ratio, beam section, area and pre-stress of cables, on the failure load. Also, the influence of the shape and scale of imperfections on the elasto-plastic buckling loads was discussed. The results show that the critical buckling load is reduced by taking account of material non-linearity. Furthermore, increasing the rise-to-span ratio or the cross-section area of steel beams notably improves the stability of the structure. However, the cross section area and pre-stress of cables pose negligible effect on the structural stability. It can also be found that the hybrid structure is highly sensitive to geometric imperfection which will considerably reduce the failure load. The proper shape and scale of the imperfection are also important.

환기조건 및 관수에 따른 단동 플라스틱 하우스의 냉방효과와 열환경 분석 (Analysis of Indoor Thermal Environment and Cooling Effects by Ventilation Condition, and Spray irrigation or Nonspray of Single Span Plastic Greenhouses)

  • 허종철;임종환;서효덕;최동호
    • 생물환경조절학회지
    • /
    • 제9권1호
    • /
    • pp.27-39
    • /
    • 2000
  • 본 실험에 앞서, 하우스 4개동에 대한 대칭성 실험을 실시하였으나, 각 하우스간에는 최대1$^{\circ}C$이내의 작은 온도차만이 계측되었다. 하우스 개폐장치 조작 불능시를 가정하여 천.측창을 인위적으로 폐쇄한 경우, 하우스 내 온도는 외 기온보다 약 16$^{\circ}C$ 높은, 즉 사실상 작물이 생육 할 수 없는 고온상태를 나타내었다. 천.측창을 개방한 상태에서는 환기팬을 추가로 가동시키더라도 이에 따른 추가적인 실온저하는 관찰되지 않았다. 비교적 분무 입경이 큰 스프링클러에 의한 환수시의 냉각효과를 검토한 결과, 하우스 내 온도는 스프링클러 작동과 동시에 급속히 하강함으로서, 관수는 하우스 실온저하에 크게 기여하고 있음이 확인되었다. 스프링클러 관수시와 비관수시로 구분하여 하우스 내 열환경을 비교한 결과, 관수시와 비관수시 모두 하우스의 천.측창을 개방하여 외기를 도입한 경우가 하우스 실온 저하에 효과적으로 작용한 것으로 조사되었다. 하우스 내 작물 체감온도에 근사한 온도지표인 실내 흑구온도는 비관수시의 경우 실내 공기온도보다 현저히 놀게 나타났으나, 관수시의 온도는 실내 공기온도에 근접한 온도를 나타내었다. 비관수시 천.측창을 개방한 경우 하우스 내 온도분포는 연직방향, 수평방향 모두 1$^{\circ}C$ 정도의 극히 작은 온도차만이 계측됨으로서, 하우스 내는 극히 균일한 온도를 유지하고 있음이 확인되었다

  • PDF

대칭 조건을 갖는 2-자유절점 공간 트러스의 평형점과 안정성 (Equilibrium Point and Stability of Double-Free-Nodes Space Truss Under Symmetric Condition)

  • 하준홍;손수덕;이승재;황경주
    • 한국공간구조학회논문집
    • /
    • 제19권4호
    • /
    • pp.69-76
    • /
    • 2019
  • A stadium roof that uses the pin-jointed spatial truss system has to be designed by taking into account the unstable phenomenon due to the geometrical non-linearity of the long span. This phenomenon is mainly studied in the single-free-node model (SFN) or double-free-node model (DFN). Unlike the simple SFN model, the more complex DFN model has a higher order of characteristic equations, making analysis of the system's stability complicated. However, various symmetric conditions can allow limited analysis of these problems. Thus, this research looks at the stability of the DFN model which is assumed to be symmetric in shape, and its load and equilibrium state. Its governing system is expressed by nonlinear differential equations to show the double Duffing effect. To investigate the dynamic behavior and characteristics, we normalize the system of the model in terms of space and time. The equilibrium points of the system unloaded or symmetrically loaded are calculated exactly. Furthermore, the stability of these points via the roots of the characteristic equation of a Jacobian matrix are classified.

Linear elastic and limit state solutions of beam string structures by the Ritz-method

  • Xue, Weichen;Liu, Sheng
    • Structural Engineering and Mechanics
    • /
    • 제35권1호
    • /
    • pp.67-82
    • /
    • 2010
  • The beam string structure (BSS) has been widely applied in large span roof structures, while no analytical solutions of BSS were derived for it in the existing literature. In the first part of this paper, calculation formulas of displacement and internal forces were obtained by the Ritz-method for the most commonly used arc-shaped BSS under the vertical uniformly distributed load and the prestressing force. Then, the failure mode of BSS was proposed based on the static equilibrium. On condition the structural stability was reliable, BSS under the uniformly distributed load would fail by tensile strength failure of the string, and the beam remained in the elastic or semi-plastic range. On this basis, the limit load of BSS was given in virtue of the elastic solutions. In order to verify the linear elastic and limit state solutions proposed in this paper, three BSS modal were tested and the corresponding elastoplastic large deformation analysis was performed by the ANSYS program. The proposed failure mode of BSS was proved to be correct, and the analytical results for the linear elastic and limit state were in good agreement with the experimental and FEM results.

초기 양식건축물의 보수.보존에 관한 연구 -국가 지정 교회건축 문화재의 현황조사를 중심으로- (A Study on Repairing and Preservation of the Early Western Style Architecture in Korea - Focused on the Case Study on the Church Buildings Which are Registered as National Cultural Properties -)

  • 김정신
    • 건축역사연구
    • /
    • 제10권2호
    • /
    • pp.55-71
    • /
    • 2001
  • This study reviewed the preservation status of the Early Western Style Architecture in Korea based on the on-site research of church buildings which are registered as National Cultural Properties. I have investigated 21 church buildings regarding the frequency, content and concept of restoration. The results are summarized as follows First, the churches have been restored extensively in every 17 years on the average. Second, the main restorations are replacement of bricks, painting, waterproofing, repair of roof and timber. And the main changes are extension of plan, removal of Interior posts, and replacement of floor. Third, the main concept of restorations are historical restoration(62%), critical restoration(23%), stylistic restoration(14%). Forth, the category of restoration have been changed, that is extending of incompletion (1st stage), functional improvement and extension of the span of life(2nd stage), improvement of facilities(3rd stage), restoration to the original state and conservation(4th stage). Fifth, the issues of repairing techniques are revival and replacement of weathered bricks, the removal of painting, and structural reinforcement. This study will be able to be used as the fundamental materials to improve the techniques of restoration of Early Western style masonry buildings.

  • PDF

Non-linear stability analysis of a hybrid barrel vault roof

  • Cai, Jianguo;Zhou, Ya;Xu, Yixiang;Feng, Jian
    • Steel and Composite Structures
    • /
    • 제14권6호
    • /
    • pp.571-586
    • /
    • 2013
  • This paper focuses on the buckling capacity of a hybrid grid shell. The eigenvalue buckling, geometrical non-linear elastic buckling and elasto-plastic buckling analyses of the hybrid structure were carried out. Then the influences of the shape and scale of imperfections on the elasto-plastic buckling loads were discussed. Also, the effects of different structural parameters, such as the rise-to-span ratio, beam section, area and pre-stress of cables and boundary conditions, on the failure load were investigated. Based on the comparison between elastic and elasto-plastic buckling loads, the effect of material non-linearity on the stability of the hybrid barrel vault is found significant. Furthermore, the stability of a hybrid barrel vault is sensitive to the anti-symmetrical distribution of loads. It is also shown that the structures are highly imperfection sensitive which can greatly reduce their failure loads. The results also show that the support conditions pose significant effect on the elasto-plastic buckling load of a perfect hybrid structure.

Output-only modal parameter identification for force-embedded acceleration data in the presence of harmonic and white noise excitations

  • Ku, C.J.;Tamura, Y.;Yoshida, A.;Miyake, K.;Chou, L.S.
    • Wind and Structures
    • /
    • 제16권2호
    • /
    • pp.157-178
    • /
    • 2013
  • Output-only modal parameter identification is based on the assumption that external forces on a linear structure are white noise. However, harmonic excitations are also often present in real structural vibrations. In particular, it has been realized that the use of forced acceleration responses without knowledge of external forces can pose a problem in the modal parameter identification, because an external force is imparted to its impulse acceleration response function. This paper provides a three-stage identification procedure as a solution to the problem of harmonic and white noise excitations in the acceleration responses of a linear dynamic system. This procedure combines the uses of the mode indicator function, the complex mode indication function, the enhanced frequency response function, an iterative rational fraction polynomial method and mode shape inspection for the correlation-related functions of the force-embedded acceleration responses. The procedure is verified via numerical simulation of a five-floor shear building and a two-dimensional frame and also applied to ambient vibration data of a large-span roof structure. Results show that the modal parameters of these dynamic systems can be satisfactorily identified under the requirement of wide separation between vibration modes and harmonic excitations.

단동하우스에서의 보강지주 설치 효과 (Effect of a Supplementary Pole on the Structural Stability in the Single-span Plastic Greenhouses)

  • 염성현;김승희;이상봉;김민영;김철수
    • 생물환경조절학회지
    • /
    • 제19권2호
    • /
    • pp.63-69
    • /
    • 2010
  • 2007년 4월 이전까지 10~15년 동안 규격시설로 운영되어 오던 농가지도형 단동하우스에서의 보강지주 설치효과를 분석하였다. 이전의 연구로 적설하중에 대한 수식 계산을 통해 보강지주 설치 단동하우스의 추가적설심이 제시된 바 있으나 모델이 농가지도형 단동하우스 규격과 상이해 연구 결과를 농가지도형 단동하우스에 그대로 적용하기에 무리가 따랐다. 본 연구에서는 농가지도형 단동하우스를 3차원 강뼈대 구조물로 모델링 하여 보강지주 설치 효과를 분석하였으며 재하시험을 통해 해석결과를 검증하였다. 구조해석 결과, 단동하우스에 보강지주 설치 시 안전적설심은 오히려 줄어드는 것으로 나타났는데 파이프 체결 부에서의 집중 하중으로 지붕도리에 큰 응력이 걸리기 때문으로 보강지주 설치 시에는 지붕도리의 규격도 함께 강화되어야 할 것으로 판단되었다. 지붕도리를 강화하고 보강지주를 3~4m 간격으로 설치할 경우, 안전적설심은 기본모델에서 보다 2배 이상 높아지는 것으로 나타났다. 보강지주 규격별 농가지도형 단동하우스 5종의 안전적설심을 제시하였다.

성주지역 참외 재배용 온실구조 현황 및 모델 개발 (Current Status and Development of Greenhouse Models for Oriental Melon Cultivation in Seongju Region)

  • 이종원;백철현;이현우;정성원
    • 생물환경조절학회지
    • /
    • 제23권2호
    • /
    • pp.95-108
    • /
    • 2014
  • 본 연구는 성주지역에 적합한 참외재배용 내재해형 온실을 개발하기 위하여 참외 재배온실의 구조현황 조사, 최근 기상자료가 반영된 설계하중 산정, 온실모델 설정 및 구조안전성 분석을 수행하였으며 결과를 요약하면 다음과 같다. 성주지역 참외온실의 구조적 특성을 파악하기 위하여 현장 조사한 결과, 온실의 지붕형상은 아치형이 가장 많았으며, 최근에 시공한 온실일수록 복숭아형이 많았으며 폭이 넓어지고 동고도 높아지는 추세였다. 그리고 성주지역에 가장 인접한 구미기상대의 기상자료를 이용하여 재현기간에 따른 설계풍속 및 설계적설심을 산정할 수 있는 계산식을 유도하였으며, 내재해형 온실규격을 만족하는 재현기간 30년의 적설심은 23.7cm, 풍속은 $33.8m{\cdot}s^1$로 계산되었다. 이러한 성주지역의 내재해형 설계기준을 만족하는 참외재배용 단동온실 4종, 2연동온실 및 연결온실을 각각 1종씩 총 6종의 모델을 개발하였다.

도시농업을 위한 소형온실 설계요인 분석 및 구조모델 개발 (Development of Structural Model and Analysis of Design Factors for Small Greenhouse of Urban Agriculture)

  • 김형권;유영선;김영화;이태석;오성식;이원석;김용현
    • 생물환경조절학회지
    • /
    • 제28권4호
    • /
    • pp.388-395
    • /
    • 2019
  • The purpose of this study is to suggest structural model and analyze design factors for the development of small greenhouse standardization model. The average dimensions of small greenhouse desired by urban farmers were 3.3m in width, 1.9m in eaves height, 2.7m in ridge height, 5.7m in length. The cladding materials for small greenhouse were preferred to glass, PC board and plastic film, framework to aluminum alloy and steel, and heating method in electrical energy. In addition, it was analyzed that small greenhouses need to develop structural model by dividing them into entry-level type and high-level type. The roof type that was used for entry-level type was arch shape, framework was steel pipe, cladding material was plastic film. On the other hand, high-level type was used in even span or dutch light type, framework with square hollow steel, cladding materials with glass or PC board. In consideration of these findings and practicality, this study developed four types of small greenhouses. The width, eaves height, ridges height, and length of the small greenhouses of even span type, which were covered with 5mm thick glass and 6mm thick PC board were 3m, 2.2m, 2.9m, and 6m, respectively. The small greenhouse of dutch light type covered with 5mm thick glass was designed with 3.8m in with, 2.2m in eaves height, 2.9m in ridges height, and 6m in length. The width, eaves height, ridges height, and length of the arch shape small greenhouse covered with a 0.15mm PO film were 3m, 1.5m, 2.8m, and 6m, respectively.