• Title/Summary/Keyword: Roller

Search Result 1,121, Processing Time 0.024 seconds

Milling Characteristics and Milled Rice Quality of Rice Varieties with Different Grain Size Shape (입형이 다른 벼 품종의 도정특성 및 쌀품위)

  • Hong, Ha-Cheol;Jeong, Young-Pyeong;Kim, Tae-Young;Son, Jong-Rok;Hwang, Hung-Goo;Choi, Hae-Chune;Min, Young-Kyoo;Kim, Kee-Jong
    • Applied Biological Chemistry
    • /
    • v.46 no.1
    • /
    • pp.46-49
    • /
    • 2003
  • Paddy and milled rice quality, milling characteristics, energy consumption of milling process were investigated using Dasanbyeo, Ansanbyeo, Hwaseongbyeo, Ilpumbyeo, and Donganbyeo varieties. Thousand grains weights of the varieties dried to 15% moisture content were 22.92-28.60 g, with Dasanbyeo being the heaviest. Optimum clearance of rubber roller for obtaining maximum dehulling recovery was 30% of each rice variety thickness. At that time, perfect brown rice ratios of Dasanbyeo, Ansanbyeo, Hwaseongbyeo, Ilpumbyeo, and Donganbyeo were 95.24%, 98.86%, 95.97%, 97.75%, and 97.31%, respectively, and showed no significant differences among varieties. Ratios of removed rice bran after two times milling ranged 70.93-91.38%, with Dasanbyeo showing the highest ratio, and the average head rice ratio was 92.87%.

Characteristics of Developed Earth Pressure by Backfill Compaction (뒷채움 시공시의 다짐토압 특성)

  • 노한성
    • Journal of the Korean Geotechnical Society
    • /
    • v.17 no.6
    • /
    • pp.163-171
    • /
    • 2001
  • It is important to pay careful attention to the backfill construction for the structural integrity of concrete box culvert. To increase the structural integrity of culvert good compaction by the dynamic compaction roller with big capacity is as effective as good backfill materials. However structural distress of the culvert could be occurred due to the excessive earth pressure by great dynamic compaction load. In this study, two box culverts were constructed with change compaction materials and construction methods. Two type of on-site soils such as subbase and subgrade materials were used as backfill materials. In most case, dynamic compaction rollers with 11 to 12 ton weights were used and vibration frequency were applied from 2000 to 2500 rpm for the great compaction energy. Backfill compactions with good quality soils were carried out to examine the effect of cushions on dynamic lateral soil pressure. Expanded polystyrene (EPS) and rubber of tire were adapted as cushion materials and they are set on the culverts before backfill construction. This paper presents the main results on the characteristics of dynamic earth pressures. Test result indicates that the amounts of increased dynamic pressures are affected with backfill materials, depth of pressure cell, and compaction condition. The earth pressure during compaction can give harmful effect to box culvert because the value of dynamic earth pressure coefficient $(\DeltaK_{dyn}=\DeltaK\sigma_h\DeltaK\sigma_v)$ during compaction is greater than that of static condition. It was observed that cushion panels of EPS(t=10cm) and rubber(t=5cm) are effective to mitigate dynamic lateral pressure on the culverts.

  • PDF

Comparison of Active and Passive Sampling Methods for Formaldehyde Concentrations Among Workplaces in Some Plywood Industries (능동포집과 확산포집법에 의한 일부합판제조업의 공정별 포름알데하이드 농도 비교)

  • Jang, Mi;Kim, Hyunwook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.6 no.1
    • /
    • pp.17-27
    • /
    • 1996
  • This study was designed to survey exposure levels of formaldehyde among workplaces in some plywood industries and to compare three sampling methods including the impinger method(IM, NIOSH method No. 3500), the solid sorbent tube method(SS, NIOSH method No. 2541), and the passive bubbler monitor method(PB, SKC). The survey was conducted in seven particle board manufacturing factories, two resin manufacturing factories and two plywood manufacturing factories in Incheon area during the period from March 6 to April 20, 1995. The workplaces included were the hot/cold press, the roller/spreader, the soaking/drying, and the reaction/mixing areas. The results were as follows; 1. The average(GM, GSD) concentrations of formaldehyde by sampling methods were 0.11(4.43) ppm by IM, 0.27(2.03) ppm by SS, and 0.29(2.04) ppm by PB, respectively. The concentrations by 1M method were statistically very significantly lower than those of SS and PB methods, particularly at low air borne concentrations of formaldehyde (p<0.001). 2. The area average concentrations of formaldehyde by workplaces measured with PB bubblers were 0.23(2.08) ppm from the press, 0.23(1.77) ppm from the spreader, 0.24(1.51) ppm from the soaking, and 0.46(1.96) ppm from the reaction areas, respectively. The personal average concentrations of formaldehyde by workplaces measured with PB bubblers were 0.30(1.77) ppm from the press, 0.33(1.54) ppm from the spreader, 0.36(1.46) ppm from the soaking, and 0.84(1.19) ppm from the reaction areas, respectively. 3. No statistically significant differences of formaldehyde concentrations among workplaces except the reaction area(p<0.001) were found. 4. Formaldehyde concentrations from personal samples were higher than those of from area sam pies in all workplaces studied. But no statistically significant differences of formaldehyde concentrations both area and personal samples were found. In conclusion, this study found that although formaldehyde concentrations in some plywood industries in Incheon area were below the regulatory limit of 1 ppm, they were over the limits recommended by NIOSH and ACGIH. This study also suggests that the impinger method may underestimate true formaldehyde concentrations. It implies that there will be more workplaces not meeting current regulatory limit if either the solid sorbent or passive bubbler methods were used instead of the impinger method. It is suggested that passive monitors will be a reasonable alternative for area and personal sampling of formaldehyde if the accuracy and validity of passive monitors be verified before use.

  • PDF

Experimental Studies of the Blood Gas Transport during Normothermic Hemodilution Perfusion (상온하 혈액희석 체외순환에 있어서 혈액 GAS 동태에 관한 실험적 연구)

  • 박희철
    • Journal of Chest Surgery
    • /
    • v.13 no.2
    • /
    • pp.85-91
    • /
    • 1980
  • Extracorporeal circulation by hemodilution technique has been currently used with its clinical safety and good peripheral tissue perfusion in open heart surgery. There is no doubt that $O_{2}$ carrying capacity of the blood is disturbed by decreased hemoglobin level resulting from hemodilution of the circulating blood. From the view point of the blood gas exchange, these experimental studies were undertaken to determined the sate limit of hemodilution in the condition of cardiopulmonary bypass with a constant perfusion flow rate. Twelve adult mongrel dogs weighing 10 to 13 Kg. were anesthetized with pentobarbital and then respiration was controlled with Harvard volume respirator using room air. The cardiopulmonary by pass was performed by use of Sarns heart lung machine (console 5000, 5 head and 2 roller pumps) and Travenol pediatric bubble oxygenator. The perfusion rate during bypass was maintained at a constant rate of 80 ml/min/Kg of body weight. The ratio of oxygen gas flow to blood flow was kept in 3 to 1 constantly. International hemodilution was attained by serial blood withdrawals and immediate infusion of equal volumes of diluants composed of Ringer's lactate, 5% dextrose in water and 25% mannitol solution, proportionally 60%, 30%, and 10%. Arterial and venous blood samples were obtained between 15 and 20 minutes following each hemodilution. Hematocrits and hemoglobin values, $PO_{2}$, $PCO_{2}$ and pH were measured. Oxygen and carbon dioxide contents oxygen consumption and carbon dioxide elimination were calculated groups according to different hematocrit values and the correlations were evaluated. Result were as follows. 1. the arterial $O_{2}$ tension and $O_{2}$ saturation were maintained at the physiological level irrespective of the hematocrit value. 2. The venous $O_{2}$ tension and $O_{2}$ saturation showed a tendency to decline with the decrease in hematocrit value and positive correlation between them (r = +0.49, r = +0.76), The mean values of venous $O_{2}$ tension and $O_{2}$ saturation, however, were not decreased when the hematocrit levels were lower than 20%. 3. The arterial $O_{2}$ content declined lineally in proportion to the fall of hematocrit level with a positive correlation between them (r = +0.95). 4. The venous $O_{2}$ contents were decreased gradually as the hematocrit value decreased with positive correlation between them ( r =+0.89). The trend of diminution of venous $O_{2}$ content, however, was became low according to progressive decrease of hematocrit level. 5. Systemic oxygen consumption was in higher range than $O_{2}$ requirement of basal metabolism when the hematocrit value was above 20%, but abruptly decreased when the hematocrit value became to below 20%. 6. The arterial $CO_{2}$ tension and $CO_{2}$ content showed trend of increasing with progressive decrease of hematocrit value but exhibited a rather broad range and there was no relationship between those value and the hematocrit value. 7. The venous $CO_{2}$ tension and $CO_{2}$ content have also no correlation with change of Ht. value but related directly to those value of arterial blood with positive correlation between them (r = +0.78, r = +0.95_. 8. A-V difference of $CO_{2}$ content and $CO_{2}$ elimination wasnot significantly influenced by Ht. value. From the results, we obtained that feasible limit in inteneional hemodilution is above the hematocrit value of 20% under the given experimental condition.

  • PDF

Numerical Modeling of Wave-Type Turbulent Flow on a Stepped Weir (계단형 보에서의 파형 난류 흐름 수치모의)

  • Paik, Joongcheol;Lee, Nam-Ju;Yoon, Young Ho
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.37 no.3
    • /
    • pp.575-583
    • /
    • 2017
  • Various types of flow patterns around the stepped weir and spillway, such as the skimming flow over such structures and the wave-type flow with a standing undular hydraulic jump and roller downstream of the structures, are developed in open channels. Unsteady three-dimensional numerical simulations are carried out using a hybrid RANS-LES turbulence modeling approach and the volume of fluid method for resolving free surface fluctuations to represent the turbulent flow including the skimming flow and wave-type flow over a stepped weir installed in a rectangular channel. The comparison of numerical results with an existing experimental measurement reveals that the present numerical simulations reasonably well reproduce the turbulent flow passing the stepped weir, in terms of time-averaged velocity profiles at selected locations downstream of the weir, flow topology characterized by the wave-type and skimming flows, the maximum height and length of the standing wave and the length of reattachment of recirculating zone. The numerical result further elucidates the distinct flow behaviors of the wave-type and skimming flow by presenting instantaneous intense variations of free surface and velocity vectors, the distributions of Reynolds shear stress and turbulent kinetic energy and three-dimensional complex features of coherent structures and total pressure distribution.

Korean Wrapping Cloths as a Decorative Art (한국 보자기의 장식성 연구)

  • Kim, Soon-Young
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.33 no.12
    • /
    • pp.1883-1896
    • /
    • 2009
  • This paper explores the use of Korean wrapping cloths (bojagi) in the late Joseon period and the types of decorations applied to them. Korean wrapping cloths called bojagi are pieces of cloths used by households of all social classes for practical purposes such as wrapping presents and covering food. In addition to the basic purposes, the making of bojagi was also an activity to express the down-to-earth wishes and the satisfaction of creation by the designer. With regard to the decorative feature of Korean wrapping cloths, five types of, patchwork, embroidered, painted, printed, and oiled-paper wrapping cloths, were examined. The patchwork wrapping cloths (jogakbo) show the frugality of Joseon women in addition to the well-developed composition skill of lines and colors. The embroidered wrapping cloths were prepared for special rituals and ceremonies such as weddings. Painted wrapping cloths were decorated with a Chinese-colors technique (called dangchae) or sometimes with black ink painting. For printed wrapping cloths, various sizes of woodblock printings and roller printings were used. Although monotone black ink was the main color applied to the printing, there was also wrapping cloths made from chintz having brilliant fast colors. Oiled-paper wrapping cloths called sikjibo were in use only for covering food. Cut-out work was employed to decorate it.

A Study on Various Soil Stiffness Evaluation Methods with Field Test (현장시험을 통한 다양한 지반강성 평가방법에 대한 연구)

  • Yoo, Wan-Kyu;Kim, Byoung-Il;Kim, Ju-Hyong;Park, Keun-Bo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.4
    • /
    • pp.1373-1380
    • /
    • 2010
  • The plate loading test(PLT) and the field density test are mainly used on the construction of embankments to control the compaction of a limited layer thickness. These two test methods are very time consuming and inefficient, but they are still commonly used as the methods of quality control for soil compaction. In the last 3 decades, many devices such as geogauge, light falling weight deflectometer(LFWD) and dynamic cone penetrometer(DCP) etc., have been introduced into the engineering market with the objective of acquiring in situ stiffness properties of the compacted soil layers. Recently, a new type of sensor, called compactometer, which in mounted on the drum of a roller and measures impact forces continuously with GPS, called as Continuous Compaction Control(CCC), has come into use in many countries such as America, Germany, Japan and so on. The main objective of this paper is to assess the potential use of these new devices as quality control and assurance devices for compacted soil layers. Based on this study, compactometer and the LFWD results werestrongly correlated with the result obtained from the PLT and the field density test.

Comparative analysis of cutter acting forces and axial stresses of single and double disc cutters by linear cutting tests (선형절삭시험에 의한 더블디스크커터와 싱글디스크커터의 커터 작용력과 축응력에 대한 실험적 평가)

  • Choi, Soon-Wook;Chang, Soo-Ho;Park, Young-Taek;Lee, Gyu-Phil;Bae, Gyu-Jin
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.16 no.2
    • /
    • pp.181-191
    • /
    • 2014
  • This study aims to evaluate cutter acting forces as well as axial stresses and torques in the shaft of two kinds of disc cutters including a single disc cutter and a double disc cutter with the same cutter ring geometry in a series of linear cutting tests. From the tests, the mean values of normal forces and rolling forces acting on the double disc cutter were approximately twice as high as those from the single disc cutter. Similarly, the mean values of axial stresses in the shaft of the double disc cutter were also twice as high as those from the single disc cutter even though the comparisons of torques from two kinds of disc cutters were insignificant since they showed very low values. However, it is necessary to take the durability of a tapered roller bearing used for the double disc cutter into high consideration since the average normal force from the double disc cutter exceeds the allowable force for a disc cutter with the diameter of 432 mm (17 inches). Finally, there is no practical problem in terms of axial stresses in the shaft of the double disc cutter since they are much lower than the yielding stress of the cutter shaft material, even though the axial stresses in the shaft of the double disc cutter are approximately twice as high as those from the single disc cutter.

A Running Stability Test of 1/5 Scaled Bogie using Small-Scaled Derailment Simulator (소형탈선시뮬레이터를 이용한 1/5 축소대차의 주행안정성 시험)

  • Eom, Beom-Gyu;Kang, Bu-Byoung;Lee, Hi-Sung
    • Journal of the Korean Society for Railway
    • /
    • v.15 no.1
    • /
    • pp.9-16
    • /
    • 2012
  • The dynamic stability of railway vehicle has been one of the important issues in railway safety. The dynamic simulator has been used in the study about the dynamic stability of railway vehicle and wheel/rail interface optimization. Especially, a small scale simulator has been widely used in the fundamental study in the laboratory instead of full scale roller rig which is not cost effective and inconvenient to achieve diverse design parameters. But the technique for the design of the small scale simulator about the dynamic characteristics of the wheel-rail system and the bogie system has not been well developed in Korea. Therefore, the research using the small-scaled derailment simulator and the 1/5 scaled bogie has been conducted. In this paper, we did running stability test of 1/5 scaled bogie using small-scaled derailment simulator. Also, for the operation of the small scaled simulator, it is required to investigate the performance and characteristics of the simulator system. This could be achieved by a comparative study between an analysis and an experiment. This paper presented the analytical model which could be used for verifying the test results and understanding of the physical behavior of the dynamic system comprising the small- scaled derailment simulator and the 1/5 scaled bogie.

A Literature Review of the Microneedle Therapy System for Hair Loss

  • Kim, Jeong-Hyon;Shim, Sung-Eun;Kim, Jun-Yeon;Kim, Ha-Na;Hwang, Ji-Min;Park, Kyeong-Ju;Jo, Min-Gi;Jang, Jun-Yeong;Kim, Jung-Hyun;Goo, Bonhyuk;Park, Yeon-Cheol;Seo, Byung-Kwan;Baek, Yong-Hyeon;Nam, Sang-Soo
    • Journal of Acupuncture Research
    • /
    • v.37 no.4
    • /
    • pp.203-208
    • /
    • 2020
  • This literature review was designed to investigate the effects of the microneedle therapy system (MTS) on alopecia in experimental, and clinical studies. The MTS is acupuncture needling therapy delivered by a roller. A literature review of studies published before May 2020 was conducted using 9 online databases, and a total of 13 studies (4 in vivo studies and 9 clinical trials) were included. Most studies showed that the MTS was effective when used in combination with other treatments. In vivo studies reported an increased level of hair growth factors following treatment. Typically, 1.5 mm needles were used in the MTS treatment and photographic evaluation (by either camera or microscope) was reported in most studies. Oriental medicine research included 2 in vivo studies, which reported positive effects when combined with the MTS. There were no reported severe side effects. the MTS might be safe and has a drug delivery effect. Further studies need to be conducted regarding the frequency and needle length depending on the type of alopecia using Oriental and Western medicine.