• Title/Summary/Keyword: Rockfall test

Search Result 22, Processing Time 0.018 seconds

In Situ Rockfall Tests for Evaluation of Rockfall Protection Fences (국내 낙석방지울타리의 적정성 파악을 위한 현장 실물 실험 및 설계기준 제시)

  • 구호본;박혁진;이경미;김규한;이재욱
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2000.11a
    • /
    • pp.629-634
    • /
    • 2000
  • Rockfall protection fence which is used for mitigation of rockfall hazard, has been constructed without consideration of lithology, height and dip angle of rock slope. However, those factors should be considered for the construction of the protection fence. In addition, the protection fence should be evaluated its performance by in-situ test in order to utilize the fence effectively. This is the first full sized rockfall test in Korea. For this test, the rock cut slope whose height is about 20 m and dip angle is 65 $^{\circ}$ has been chosen. Based on the preliminary simulation procedure, four different concrete balls (0.5 ton, 1.0 ton, 2.0 ton and 5.0 ton) were prepared and four different types of protection fence were constructed. The results of this test will be utilized in the establishment of rockfall protection fence construction manual.

  • PDF

Study for the Proposal of Design Specifications for Rockfall Protection Fences by Full Scale Tests (현장실험을 통한 낙석방지울타리 설계기준 제시 연구)

  • 박혁진;구호본;이경미;김규한
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2000.11b
    • /
    • pp.139-151
    • /
    • 2000
  • Rockfall protection fence is one of the most common rockfall protection measures in Korea. The fences have been constructed in almost every hazardous cutslopes along national highway in Korea. However, the capability and performance of the fence as rockfall protection system are seldom known since no field test which can provide information on the response and the behavior of fence was carried out. This is the first full scaled rockfall test in Korea. The objectives of the test are to provide the information on the behavior and the capability of fence and to propose the design specifications for the fence. In this test, four different systems have been selected and tested. For each test, the rockfall impact energy was analyzed and the response and behavior of the system were investigated.

  • PDF

Performance Assessment of Flexible Wire Rope Rockfall Protection Fence for 100 kJ Energy Absorption (100 kJ 낙석에너지 흡수가 가능한 유연성 와이어로프 낙석방지울타리 성능검증)

  • Son, Jing-ik;Shin, Yong-chul;Kim, Jung-woo;Moon, Hyung-Bum;Lee, Kyung-soo
    • The Journal of Engineering Geology
    • /
    • v.32 no.4
    • /
    • pp.499-511
    • /
    • 2022
  • In this study, a vertical drop test was carried out to identify the performance of flexible wire rope rockfall protection fence by 100 kJ rockfall energy according to ETAG 027. The flexible wire rope, which consists of wire rope and spring. is especially enhanced the elasticity and flexibility so that it can be longer elongated when the rope is impacted by rockfall compared to original wire rope, and that results longer increase of contact time between rockfall and wire rope and increase rockfall energy absorption capability and decreases rockfall impact force. The test results shows that the plastic deformation occurred in middle post and the final deflection of the middle post was 1.15 m, which is lower than 2.0 m determined by ETAG 027. This vertical test verified the flexible wire rope rockfall protection fence can successfully absorb 102.9 kJ rockfall energy.

Performance Evaluation of High-strength Rockfall Net on Field Test (현장 테스트를 통한 고강도 선제 포획망 성능 테스트)

  • Hyunwoo Jin;Sanghoon Seo;Youngcheol Hwang
    • Journal of the Korean GEO-environmental Society
    • /
    • v.24 no.3
    • /
    • pp.15-21
    • /
    • 2023
  • Although standards related to falling stone facilities are established in Korea, the absorption energy of the rockfall prevention net is evaluated from the passage of rockfall and destruction of the rockfall prevention net on field test. The existing PVC coating net does not sufficiently suppress the rockfall load and tears frequently occur, and a high-strength wire rockfall net was developed to prevent. In this study, the performance was analyzed through field tests of the existing PVC coating net and the developed high-strength rockfall net (1,000 MPa, 2,000 MPa).

A Study on Rockfall Energy and Rockfall Protection Fence Applications on the Slope (사면에서 발생하는 낙석에너지와 낙석방지울타리 적용성에 관한 연구)

  • 김남호;신윤섭;박윤재;조종석
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2002.03a
    • /
    • pp.523-530
    • /
    • 2002
  • Recently, while rockfall occurs very frequently, a lot of researches on the rockfall protection fence Is in process. But the rockfall protection fence has been installed unrelated to slope characteristics, rockfall shape and rockfall height. Therefore, in this study we suggested the effective protection fence model considering about rockfall energy and energy absorbing capacity and we verified the model by field test. According to these results, it is more reasonable to evaluate rockfall energy based on the results of simulation program, which can be consider effects of energy decrease, than use the simplified method proposed by Japanese road association. And rockfall energy is affected by the size of supports and wire rope and the space of supports. As the results of comparing rockfall energy with energy absorbing capacity, type$\circled1$(the space of supports is changed to 3.0m)can be available for generally expected rockfall except the rock slope over 30m heights. But rockfall protection fence installed at the field, it should be partially reinforced after consideration of slope particularities and construction conditions.

  • PDF

Field Test for Absorption Energy and Displacement of Rockfall Protection Net (낙석방지울타리 망의 변위량 및 성능검증을 위한 실물낙석시험)

  • Seo, JinHyuk;Hwang, Youngcheol
    • Journal of the Korean GEO-environmental Society
    • /
    • v.21 no.12
    • /
    • pp.17-21
    • /
    • 2020
  • Over 60% of South Korea's land consists of mountainous topography, and recently, due to earthquakes, localized heavy rains and road development, the risks of rockfalls are getting higher. As of now, rockfall prevention facilities are being constructed in 70% of Korean roads cut slope and rockfall protections account for about 20% of them. Rockfall protection's supporting capacity is defined by combining performance of wire mesh, pillars and wire ropes. For the existing constructed rockfall protection, standards of pillars that can absorb 48~61 kJ amount of energy, wire ropes and wire mesh are presented in Guidelines for the installation and management of traffic safety facilities, Rockfall prevention facilities by Ministry of Land, Transport and Maritime Affairs (2008). However, each factor's correlation of absorption energy is not presented so it is uncertain. This study will conduct vertical drop test and identify adequacy of rockfall protection net of displacement quantity calculation factor which is delta and evaluate rockfall protection net's absorbable energy through standards of overseas performance evaluation criteria.

Performance Evaluation of Rockfall Prevention Net Using Laboratory Pullout Test (실내인발시험을 이용한 낙석방지망 성능평가)

  • Kim, TaeSik;Seo, JinHyuk;Hwang, Youngcheol
    • Journal of the Korean GEO-environmental Society
    • /
    • v.21 no.12
    • /
    • pp.11-16
    • /
    • 2020
  • It is necessary to assess the proper performance of the existing rockfall prevention net in order to minimize the damage to human lives and property in the event of rockfall. However, there is no standard for performance evaluation of rockfall prevention net in Korea, and only the design of rockfall prevention net exists by calculating energy that can be absorbed energy. Therefore, laboratory pullout test was conducted for the performance evaluation of the rockfall prevention net, cuts and load-displacement characteristics of the PVC coating net used in the laboratory pullout test are determined to identify the performance of the rockfall prevention net.

Estimation of Absorbing Capacity from Rockfall Protection Fences (도로 낙석방지울타리의 낙석지지능력 평가 연구)

  • Hwang, Young-Cheol
    • Journal of the Korean GEO-environmental Society
    • /
    • v.3 no.4
    • /
    • pp.59-66
    • /
    • 2002
  • Designs for rockfall protection systems must consider rock and soil types, the angle of the slope, conditions on top and the toe of the affected area. Rockfall protection fence is installed to block for falling rock from cut slopes and this is one of the most common rockfall protection measures. The capability of the fence is provided that sum of capability of poly vinyl chloride coated wire mesh, steel support and wire rope respectively. But in some case, the rockfall protection fence was not supported rockfall energy less than total capability of the fence through the full scale rockfall tests. Therefore, the objectives of this paper are to indicate the problems of fence capability and to improve the design specifications for the fence.

  • PDF

A Study on Efficient Design of Rockfall Prevention Netting (낙석방지망의 효율적 설계를 위한 기초연구)

  • Lee, Jundae;Park, Soobeom;Bae, Wooseok
    • Journal of the Korean GEO-environmental Society
    • /
    • v.15 no.12
    • /
    • pp.53-59
    • /
    • 2014
  • In order to obtain basic data for reasonable design of rockfall prevention net unreasonably being designed according to experiences, this paper determined a standard cross section and analyzed the effects of parameters such as inclination and height of slope faces, rockfall weight, separation distance on rockfall behaviors such as bounce height, kinetic energy and passage rate. The weight of rockfall changed from 400 kg to 700 kg and then to 1,000 kg. With the height of 20 m as the standard, the test was conducted with the inclination at $63^{\circ}$ and $55^{\circ}$ which may affect rockfall behaviors. Analysis was made while changing the fall height of rockfall from 3 m to 15 m and then to 20 m, thereby analyzing and evaluating changes in maximal kinetic energy occurring in the base of slope. According to the analysis result, in designing a rockfall prevention wire net, a design considering various conditions including inclination of the slope, expected size or weight of rockfall, situation of the slope and the shape of rockfall, and rockfall trace is judged necessary beyond the current uniform application.

Characteristics and Energy Absorbing Capacity for Rockfall Protection Fence from In-Situ Rockfall Tests (현장 낙석실험을 통한 낙석방지울타리의 특성 및 성능 평가)

  • 구호본;박혁진;백영식
    • Journal of the Korean Geotechnical Society
    • /
    • v.17 no.6
    • /
    • pp.111-121
    • /
    • 2001
  • Rockfall protection fences are used for diminishing rockfall damage in roads side slopes. In order to install the fences in effective way, the conditions of rock slopes and total predicted impact energy of fa11ing rock should be considered. However, the fences have been constructed without any consideration for lithology, height and slope angle of rock slope in Korea. In addition, the information about the performance of the protection fences, which should be evaluated by in-situ test or laboratory test in order to check out the practical use in the field, is not available. Therefore, in design manual for the rockfall protection fence, the specific details for the installation of this type of fence are not provided yet. The full sized rockfall in situ test was carried out for the calculation of falling energy of rock and the evaluation of the maximum energy absorbing capacity of fence. For this test, the rock slopes whose heights are about 20 m and dip angle of 65 degree, have been chosen. This is because those geometries are mean height and slope angle of most road cut slopes along Korean national highway. Based on the preliminary simulation procedure, four different sizes of concrete ball (0.7, 1.3, 2.3 and 4.3 ton) were prepared and flour different types of protection fence were constructed. The results of this test provide information about the maximum energy absorbing capacity of the fence, kinetic energy of rockfall and restitution coefficient, and these results can be utilized in the establishment of rockfall fence design and construction manual.

  • PDF