• Title/Summary/Keyword: Roadway Design

Search Result 154, Processing Time 0.032 seconds

A Study on Damping Value of Bridge in High-speed Railway (고속전철 교량 감쇠 연구)

  • 최은석;진원종;곽종원;박성용;강재윤;김영진;김병석
    • Journal of the Korean Society for Railway
    • /
    • v.4 no.1
    • /
    • pp.23-30
    • /
    • 2001
  • The dynamic characteristics such as natural frequency, mode shape and damping ratio are most important parameters in the high-speed railway bridges rather than general roadway bridges. Also, the need to know the dynamic behavior of bridges greatly increased in recent years. In the early of 1990s, to design the high-speed railway bridges, damping ratio recommended in general code was 2.5~7.5%. However, these values were not applied in all cases. Therefore, obtaining the damping value of specific structures is important to get the correct variable for design of high-speed railway bridges. The purpose of this study is mainly to obtain the damping ratio of high-speed railway bridges. The average damping ratio of high-speed railway bridges evaluated from a field test is about 2.4%.

  • PDF

A Simple Approach for Determining No-Passing Zones in Two-Lane Rural Highways

  • Son, Bong-Soo
    • Proceedings of the KOR-KST Conference
    • /
    • 1998.09a
    • /
    • pp.141-151
    • /
    • 1998
  • Provision of Passing Sight Distance (PSD) is an important component in two-lane highway design and has a critical impact on capacity of highway and safety of drivers. Many models have been developed to estimate PSD reasonably. However, each of them has a number of shortcomings for reflecting the real traffic conditions. This paper introduces a revised model that reflects the characteristics of the passing maneuver. The changes in passing sight distances under different assumptions about acceleration and vehicle length, which are related to vehicle types, are presented. The results obtained by the revised model are compared with those obtained from the existing models. There is an important link between geometric design decisions which determine the available sight distance and the quality of service which the road provides. In this paper, we examine one aspect of this relationship. That is to determine whether the passing sight distance is provided by improving horizontal alignment for a specific roadway section or passing may be restricted to save the road construction cost. To do so, a simple method for estimating traffic delay in no-passing is introduced.

  • PDF

Impact Effects of Multi-Girder Steel Bridges Under Various Traffic Conditions (차량하중에 의한 다주형 강판형교의 충격계수 변화에 관한 연구)

  • 김상효;허진영
    • Computational Structural Engineering
    • /
    • v.10 no.3
    • /
    • pp.233-240
    • /
    • 1997
  • The study presents the linear dynamic analysis of multi-girder steel bridges under vehicular movement to examine the performance characteristics due to the various structural and loading conditions. The road surface roughness and bridge-vehicle interactions are considered. The road surface profiles for the approaching roadway and bridge decks are generated from power spectral density functions for different road roughness conditions. A new filtering method using the wheel trace is proposed to obtain the more rational bridge-vehicle interactions from the randomly generated road surface. The possible settlement condition between the bridge deck and approaching roadway is also included. The dynamic responses of various bridges designed according to current design practice are examined, in which important structural parameters(such as span length, girder spacing, etc.) are considered systematically. In addition to the basic loading conditions due to a single truck passing on the bridge, the traffic conditions of multi-truck traveling either consecutively on the same lane or side-by-side on the adjacent lanes are also evaluated.

  • PDF

A Kalman filter based algorithm for wind load estimation on high-rise buildings

  • Zhi, Lun-hai;Yu, Pan;Tu, Jian-wei;Chen, Bo;Li, Yong-gui
    • Structural Engineering and Mechanics
    • /
    • v.64 no.4
    • /
    • pp.449-459
    • /
    • 2017
  • High-rise buildings are generally sensitive to strong winds. The evaluation of wind loads for the structural design, structural health monitoring (SHM), and vibration control of high-rise buildings is of primary importance. Nevertheless, it is difficult or even infeasible to measure the wind loads on an existing building directly. In this regard, a new inverse method for evaluating wind loads on high-rise buildings is developed in this study based on a discrete-time Kalman filter. The unknown structural responses are identified in conjunction with the wind loads on the basis of limited structural response measurements. The algorithm is applicable for estimating wind loads using different types of wind-induced response. The performance of the method is comprehensively investigated based on wind tunnel testing results of two high-rise buildings with typical external shapes. The stability of the proposed algorithm is evaluated. Furthermore, the effects of crucial factors such as cross-section shapes of building, the wind-induced response type, errors of structural modal parameters, covariance matrix of noise, noise levels in the response measurements and number of vibration modes on the identification accuracy are examined through a detailed parametric study. The research outputs of the proposed study will provide valuable information to enhance our understanding of the effects of wind on high-rise buildings and improve codes of practice.

Case Study of the Longest Roadway Tunnel in Korea, Baehuryeong Tunnel (국내 최장대 양방향 도로터널 설계사례-배후령터널)

  • Lee Seon-Bok;Je Hae-Chan
    • Tunnel and Underground Space
    • /
    • v.15 no.6 s.59
    • /
    • pp.432-440
    • /
    • 2005
  • Baehuryeong tunnel connects Chuncheon with Hwacheon in Kangwon, Korea, This tunnel is a single tunnel with 5,057 m long and two bidirectional lanes which will be extended into low lanes in the future. The estimated construction period of Baehuryeong tunnel is approximately 55 months. This tunnel will become the longest bidirectional roadway tunnel in Korea. Compared to a twin tunnel, a bidirectional single tunnel has two major disadvantages with regard to the ventilation system and ease of escape during fire. For these reasons, a service tunnel and the transverse ventilation system are planned first time in Korea. In case of fire, the tunnel ventilation design aims to maintain a smoke free layer for passenger evacuation. The geology of Baehuryeong tunnel site is mainly composed of gneiss and granite. Baehuryeong fault is a mainly large scale fault which stands vertical and parallels with tunnel direction. The influenced zone of this fault is within 70 m. Baehuryeong tunnel was designed that it was separated with the distance of more than 100 m from Baehuryeong fault for its safety.

Capacity Analysis in the Ramp Junction of the Urban Freeway Connected with the Busan Port (부산항과 연계된 도시고속도로의 연결로 접속부내 용량특성분석에 관한 연구)

  • Kim, Tae Gon;Jeong, Young Hwan;Park, Jong Man;Ji, Seung Keun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.2D
    • /
    • pp.205-216
    • /
    • 2008
  • Urban freeway is defined as the roadway with 4 lanes or more which requires a high design criteria for handling a large capacity of vehicles rapidly as a high-speed exclusive roadway in the city. However, most of the urban freeways suffer from severe traffic congestion due to the increased traffic exceeding their capacities regardless of the morning and afternoon rushhours or the inbound and outbound directions. The purpose in this study is to collect and investigate the real-time traffic characteristics based on the ramp junction influence areas of the urban freeway connected with the Busan port, compare and analyze the traffic characteristic relationship for each lane within the ramp junction influence areas, and finally assess and suggest the optimal capacity for each lane within the ramp junction influence areas.

Pseudo-Dynamic Test for Seismic Performance Evaluation of RC Bridge Piers (실물 철근콘크리트 교각의 유사동적 실험에 의한 내진성능 평가)

  • 박창규;박진영;정영수;조대연
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2002.03a
    • /
    • pp.250-257
    • /
    • 2002
  • Pseudo dynamic test is an on-line computer control method to achieve the realism of shaking table test with the economy and versatility of the conventional quasi-static approach Pseudo dynamic tests of six full-size RC bridge piers have been carried out to investigate their seismic performance. For the purpose of precise evaluation, the experimental investigation was conducted to study the seismic performance of the real size specimen, which is constructed for highway bridge piers in Korean peninsula. Since it is believed that Korea belongs to the moderate seismicity region, five test specimens were designed in accordance with limited ductility design concept. Another one test specimen was nonseismically designed according to a conventional code. Important test parameters were transverse reinforcement and lap splicing. Lap splicing was frequently used in the plastic hinge region of many bridge columns. Furthermore, the seismic design code is not present about lap splice in Korean Roadway Bridge Design Code. The results show that specimens designed according to the limited ductility design concept exhibit higher seismic resistance. Specimens with longitudinal steel lap splice in the plastic hinge region appeared to significantly fail at low ductility level.

  • PDF

Limited Ductile Capacity of Reinforced Concrete Bridge Pier with Longitudinal Steel Lap-splicing by Pseudo Dynamic Test (유사동적 실험에 의한 철근콘크리트 교각의 주철근 겹이음에 따른 한정연성능력)

  • 박창규;박진영;조대연;이대형;정영수
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.05a
    • /
    • pp.885-890
    • /
    • 2002
  • Pseudo dynamic test is an on-line computer control method to achieve the realism of shaking table test with the economy and versatility of the conventional quasi-static approach. Pseudo dynamic tests of four full-size RC bridge piers have been carried out to investigate their seismic performance. For the purpose of precise evaluation, the experimental investigation was conducted to study the seismic performance of the real size specimen, which is constructed for highway bridge piers in Korean peninsula. Since it is believed that Korea belongs to the moderate seismicity region, three test specimens were designed in accordance with limited ductility design concept. Another one test specimen was nonseismically designed according to a conventional code. Important test parameters were transverse reinforcement and lap splicing. Lap splicing was frequently used in the plastic hinge region of many bridge columns. Furthermore, the seismic design code is not present about lap splice in Korean Roadway Bridge Design Code. The results show that specimens designed according to the limited ductility design concept exhibit higher seismic resistance. Specimens with longitudinal steel lap splice in the plastic hinge region appeared to significantly fail at low ductility level.

  • PDF

Intersection Sight Distance Based on Critical Gap at Unsignalized Intersections (임계간격을 이용한 비신호 교차로의 시거 산정에 관한 연구)

  • 이슬기;이용재;김석근
    • Journal of Korean Society of Transportation
    • /
    • v.21 no.5
    • /
    • pp.97-110
    • /
    • 2003
  • The sight distance at unsignalized intersections is the one of the fundamental geometric design elements, and can ensure safety and efficient operations. Despite its importance, little research attention has been directed in Korea compared to developed countries such as European countries, the United States, and Japan. AASHTO ISD policies have been applied to the intersection design in Korea without any revise, which can produce unrealistic and unadoptable design values. Those values are emerged from several reasons because the AASHTO ISD has been calibrated based on the local data. Therefore the ISD hardly takes into account the local characteristics of Korea such as driving behavior. vehicular movement and roadway conditions. The objective of this study is to calculate the appropriate ISD values for unsignalized intersections in the urban area in Korea. In this study, we employed the ISD model of AASHTO(2001), which is based on gap acceptance theory and can account for and take the driving and roadway conditions in Korea into consideration. The approach can also consider the complex driving maneuvers at the intersections in a proper and simple manner. The results in this study show that the ISD design criteria currently used in Korea are more conservative(safer) than those of the USA. In other words, the ISD using field data collected in this study has generally smaller values than those in USA.

No Collapse Design for Typical Bridges (일반교량의 붕괴방지설계)

  • Kook, Seung-Kyu
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.27 no.3
    • /
    • pp.163-172
    • /
    • 2014
  • The purpose of earthquake resistant design for typical bridges is the No Collapse Design and the Earthquake Resistant Design Part of Roadway Bridge Design Code provides a design process to construct the Ductile Failure Mechanism for the bridge structure. However, if it is not practical to provide the Ductile Failure Mechanism due to structure types or site conditions, the Brittle Failure Mechanism is an alternative way to get the No Collapse Design. As well as the existing design process constructing the Ductile Failure Mechanism, the Earthquake Resistant Design Part provides a ductility-based design process as an appendix, which is prepared for bridges with reinforced concrete piers. According to the new design process, designer determines a required response modification factor for substructure and transverse reinforcement for confinement therefrom. In this study, a typical bridge with steel bearing connections and reinforced concrete piers is selected for which the existing as well as the ductility-based design processes are applied and different results from the two design processes are identified. Based on the results, an earthquake resistant design procedure is proposed in which designers should consider the two design processes.