• Title/Summary/Keyword: Road freezing

Search Result 150, Processing Time 0.028 seconds

Study on Stability Analysis of Rock Slope Under Freezing-Thawing Cycle (동결융해작용을 받는 암반사면의 안정성해석에 관한 연구)

  • Baek, Yong
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2000.11a
    • /
    • pp.543-550
    • /
    • 2000
  • Rock slopes along the road or railroad are affected by temperature and therefore experienced iterative freezing-thawing process between winter and early spring. The purpose of this study is to analyze the stability of rock slopes which are influenced by the deterioration due to the freezing-thawing. The analysis is the homogenization method which evaluates the strength property of discontinuous rock mass, and as a strength failure criterion, Drucker-Prager failure criterion is used. The deterioration property of real rock is obtained by a freezing-thawing laboratory test of tuff and this property of deterioration is quantitated and used as a basic data of stability analysis for rock mass. To evaluate the deterioration depth due to the freezing-thawing in situ rock slope, one dimensional heat conductivity equation is used and as the result I can find that the depth of which is affected by a temperature. After the freezing-thawing depth of model slope is determined, we analyze the pattern of rock mass stength value of rock slope model which excesses the limit of self-load.

  • PDF

A Study on Compute of Freezing Depth through Frost Damage Investigation in Gangwon Region (강원지역 동상 피해조사를 통한 동결심도 산정 연구)

  • Seungwoo Ahn;Beomsu Moon;Woocheol Jeong;Songhee Suk;Song Choi;Yongseong Kim
    • Journal of the Korean Geosynthetics Society
    • /
    • v.22 no.1
    • /
    • pp.97-107
    • /
    • 2023
  • This study analyzed the causes of frost damage and freezing depth for concrete ballast sites in the Gangwon mountainous area, which has a high freezing index, and considered the equation for freezing depth in concrete roadbeds. Comparing the freezing depth tendencies of concrete roadbeds in the Gangwon mountainous area and Gangwon area, it was found that the freezing depth of concrete roadbeds was higher than that of the Gangwon area when the freezing index was less than 400. However, in sections with a freezing index greater than 400, the freezing depth was higher in the Gangwon area than in the concrete roadbeds. This study proposed an equation for computing the freezing depth in the Gangwon area to provide basic data for establishing preventive measures against frost damage during railway and road construction projects in the Gangwon region.

Development of Rural Road Pavement Technology Using Cement Stabilizer (시멘트계 고화재를 활용한 농어촌도로 포장공법 개발)

  • Oh, Young-In;Kong, Gil-Yong;Kim, Seung-Wook
    • International Journal of Highway Engineering
    • /
    • v.9 no.4
    • /
    • pp.171-184
    • /
    • 2007
  • Chemical admixture stabilization has been extensively used in both shallow and deep stabilization in order to improve inherent properties of the soil such as strength and deformation behavior. An increment in strength, a reduction in compressibility, an improvement of the swelling or squeezing characteristics and increasing the durability of soil are the main aims of the admixtures for soil stabilization. Recently, the various advanced cement stabilizer mixing technique was developed. Advanced cement stabilizer mixing technique is environmentally-friendly and has an excellent mixing property and outstanding mixing speed. In this study, to develop the rural road pavement technology using cement stabilizer, compaction and unconfined compression test were performed with various mixing ratio and two types of soil(clay and silty soil). And the freezing/thaw test and bending strength test performed to develop suitable cement stabilizer material for stabilization of rural road. Based on the test results, the liquid types of cement stabilizer material and silty soil mixture are most suitable for rural road construction and although the mixing ratio is low, cement stabilizer mixture is effective for durability of rural road surface layer.

  • PDF

Freezing and Thawing Properties of Polypropylene Fiber Reinforced Eco-concrete (폴리프로필렌 섬유보강 에코콘크리트의 동결융해 특성)

  • Sung Chan-Yong
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.48 no.2
    • /
    • pp.59-66
    • /
    • 2006
  • This study is performed to evaluate freezing and thawing properties of polypropylene fiber reinforced eco-concrete using soil, natural coarse aggregate, soil compound and polypropylene fiber. The mass loss ratio is decreased with increasing the content of natural coarse aggregate and soil compound, but it is increased with increasing the content of polypropylene fiber. The ultrasonic pulse velocity, dynamic modulus of elasticity and durability factor are increased with increasing the content of natural coarse aggregate and soil compound, but it is decreased with increasing the content of polypropylene fiber. The mass loss ratio, ultrasonic pulse velocity, dynamic modulus of elasticity and durability factor are $1.49{\sim}3.32%,\;1,870{\sim}2,465\;m/s,\;77X10^2{\sim}225X10^2\;MPa\;and\;84.6{\sim}92.8$ after freezing and thawing 300 cycles, respectively. These eco-concrete can be used for environment-friendly side walk and farm road.

A Study on the Freezing and Thawing Resistance of Permeable Polymer Concrete (투수성 폴리머 콘크리트의 동결융해 저항성에 관한 연구)

  • 박응모;조영국;소양섭
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.04a
    • /
    • pp.331-336
    • /
    • 1999
  • Permeable polymer concrete in this study is one of the environment conscious concrete that can be applied at road, side walks and river embankment, etc. The purpose of this study is to evaluate the effects of mix proportions such as resing content, filler-binder ratio and aggregate ratio on the freezing and thawing resistance of permeable polymer concrete. The permeable polymer concrete are prepared with the resin ratio of 5%, 6% and 7%, filler-binder ratio of 0, 0.5 and 1.0, and 2.5~5mm sized aggregate ratio to standard sand of 10:10, 10:20, 20:10 and 20:20. It is tested for freezing and thawing test according to ASTM C 666092, and then, weight change, length change, relative dynamic modulus, durability factor, and compressive and flexural strengths after test are measured. From the test results, the resistance to freezing and thawing of permeable polymer concrete increased with increase the resing content, filler-binder ratio and fine aggregate ratio.

  • PDF

An Experimental Study on the Freezing and Thawing of Concrete Mixed with Steel Slag (제강 슬래그를 이용한 콘크리트의 동결융해에 대한 실험적 연구)

  • 정원섭;조성현;권기주;박성우;김진만
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.11a
    • /
    • pp.48-53
    • /
    • 2003
  • The steel slag, a by-product which is produced on the process of manufacturing steel by refining pig iron is mainly used as road materials after aging it. It is necessary to age steel slag for long time in air because the reaction with water and free-CaO in steel slag could make the volume expanded. Due to this reason it prevents steel slag from being used as aggregate of concrete. But steel slag used in this study is controled by a air-jet method which rapidly cools substance melted at a high temperature. Rapid cooling prevents from generating of free-CaO in steel slag. In this study, it was investigated that steel slag manufactured by air-jet method affects on concrete in the freezing and thawing. As results of this study, concrete mixed with steel slag was worse in the freezing and thawing than concrete mixed with sand in spite of using air entraining agent. To obtain durability of concrete in the freezing and thawing, it is desirable to mix 50% of steel slag in concrete per unit weight of volume.

  • PDF

A Study on The Frost Penetration Depth of Pavement with Field Temperature Data (도로포장 현장계측 온도데이터를 이용한 도로포장체의 동결깊이 연구)

  • Shin, Eun-Chul;Lee, Jae-Sik;Cho, Gyu-Tae
    • International Journal of Highway Engineering
    • /
    • v.13 no.1
    • /
    • pp.21-32
    • /
    • 2011
  • The frost penetration depth of pavement is usually estimated from the freezing index that made temperature data analysis of 30 years and decided the thickness of anti-frost layer. The field monitoring region in study was divided into five regions by freezing index 550~650$^{\circ}C{\cdot}$day, 450~550$^{\circ}C{\cdot}$day and 350~450$^{\circ}C{\cdot}$day. Each region has three-section of road pavement such as cutting area, boundary area of cutting and banking, and lower area of banking. The field monitoring system was established both in the section of anti-frost layer and in the section without anti-frost layer. The data analysis was conducted for determination of frost penetration depth within the paved road by the field monitoring system. The result showed that The temperature of subgrade without anti-frost layer shows below zero in centigrade for the region of freezing index 550~650$^{\circ}C{\cdot}$day, up and down around zero degree in subgrade for the region of freezing index 450~550$^{\circ}C{\cdot}$day, and there is no place existed below zero degree in subgrade for the region of freezing index below 450$^{\circ}C{\cdot}$day. With comparison of field frost penetration depth for the cross-sections of pavement, the cutting area shows the greatest frost penetration depth, and less influence of frost penetration depth for the boundary area of cutting and banking, and the least influenced for the lower area of banking.

Characteristics of Black Ice Using Thermal Imaging Camera (열화상카메라를 이용한 블랙아이스 특성 연구)

  • Kim, Seung-Jun;Yoon, Won-Sub;Kim, Yeon-Kyu
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.24 no.6_2
    • /
    • pp.873-882
    • /
    • 2021
  • In this study, a study was conducted to develop a system for predicting/responding to black ice occurring on roads in winter. Tests conditions were studied by making models of cement concrete pavement and asphalt concrete pavement. In order to freeze water on the manufactured model package, an tests was conducted at a temperature below zero using a freezer, and the freezing process was photographed using a thermal imaging camera. Black ice is generated when water is present on the road surface and the temperature is below freezing or the road surface temperature is below the dew point temperature. Under sub-zero conditions, the pavement, water, and ice were classified with a thermal imaging camera. As a result of the tests, it was possible to distinguish with a thermal imaging camera at a temperature below freezing in the same freezer due to the difference in the emissivity of the packaging, water, and ice. In the process of changing from water to ice during the tests, it was analyzed that ice and water were clearly distinguished by the thermal imaging camera due to the difference in emissivity and reflectance, so black ice could be predicted using the thermal imaging camera.

Arduino Sensor based on Traffic Safety System using Intelligence

  • Choi, Myeong-Bok;Hong, You-Sik
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.9 no.1
    • /
    • pp.18-23
    • /
    • 2017
  • In 2015, 100-car pileup was happened because the safe distance from the car in front did not be kept due to much fog at YoungJong Bridge in South Korea. This is why the road would be benumbed with cold weather in winter. For this weather condition, if the driver of the car in front changed the lane suddenly or suddenly slammed on the brake in fog or freezing area, the braking distance of the real car has to be 2 or 3 times longer than usual. In this paper, we have simulated the function that warns and notice about the fog area or the freezing one in the road using Arduino sensors and Beacon. Also we propose the intelligent traffic system to protect the accidents in winter.

A Basic Study of the Snow Melting System for the Anti-Freezing Road using the Pulsating Heat Pipe (PHP를 이용한 도로융설 시스템에 관한 기초연구)

  • Kim, J.S.;Ha, S.J.;Son, K.J.
    • Journal of Power System Engineering
    • /
    • v.14 no.3
    • /
    • pp.19-24
    • /
    • 2010
  • The purpose of this study is to develop a snow melting system using the pulsating heat pipe(PHP). The experimental apparatus is consisted of a PHP, a concrete structure, a constant water thermostatic bath and a flowmeter. The experiment was performed at the outdoor air temperature of $-8^{\circ}C$ and inlet temperature of hot water of $75^{\circ}C$. PHP is the closed and non-loop type heat exchanger which is charging R-410A as an operating fluid. As experimental results, the temperature profile of vertical and horizontal orientation of concrete structure was measured with operating time. The heat flux of the snow melting was required more than 300 $W/m^2$. We confirmed that the snow melting system using the PHP was useful for anti-freezing road.