• Title/Summary/Keyword: Risk safety areas

Search Result 390, Processing Time 0.027 seconds

Study on Risk Analysis for Software Functional Safety of Marine Navigational Equipment (항해장비 소프트웨어 기능안전성 확보를 위한 위험분석 단계 연구)

  • Lim, Sang-Woo;Lee, Seojeong;Yang, Hoi-seok
    • Journal of Digital Contents Society
    • /
    • v.18 no.2
    • /
    • pp.393-401
    • /
    • 2017
  • As the importance of software in various industry areas has been increased, the number of accidents related to software safety are growing up. The key industries such as railroads, aviation and medicine, recommend IEC 61508 and international safety standards for their own to achieve functional safety and reduce the issues caused by that. For equipment of ship navigation, there are not any particular standards or guidance which Korean users can introduce as considering software functional safety. This article defines the procedure and outcomes of the risk analysis in order to secure software functional safety in marine navigational equipment and applies them to an echo sounder as a case study.

Application of Drones for the Analysis of Hazard Areas in Mountainous Disaster (산지재해 발생 위험지역 분석을 위한 드론의 적용)

  • Lee, Jeong Hoon;Jun, Kye Won;Jun, Byong Hee
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.3
    • /
    • pp.65-70
    • /
    • 2018
  • Terrain data for disaster analysis in hazardous or disaster areas is not only important but also needs to be built quickly. In particular, the introduction of drones is in the early stages of research using drones in a variety of fields such as shooting, analyzing and managing hazardous areas. It is expected that drone will be faster, safer and more effective than existing data collection method in case of small scale disaster hazard area and disaster area where equipment or manpower input is difficult. Therefore, in this study, drone shooting was performed for hazardous areas in mountainous roads located in Samcheok city, Gangwon province, and ground reference points were measured by RTK-GPS. The measured data were converted into DSM (Digital Surface Model) data by coordinate correction using Pix4D postprocessing program and then applied to the analysis of the hazard area of mountainous area. As a result, it was shown that it is effective to identify the risk by using the basic terrain data obtained from the drones.

Construction of an Exposure Risk Map and Spatial Knowledge Base for Asbestos in Korea (석면 공간지식베이스 구축을 통한 석면 노출위험도 작성)

  • Hwang, Jae-Hong;Lee, Byung-Joo
    • The Journal of Engineering Geology
    • /
    • v.21 no.4
    • /
    • pp.393-402
    • /
    • 2011
  • Asbestos is a toxic material that can lead to lung cancer and other diseases. There is no information regarding areas in Korea that contain asbestos in nature; consequently we need to manage such areas with care. The purpose of this study was to construct a local graded map of asbestos exposure risk based on the natural occurrence of asbestos in rocks. We first developed a means of evaluating the asbestos exposure risk and produced thematic maps based on a field survey. In addition, we constructed a knowledge base for asbestos through analysis, representation and processes about asbestos data and prepare for the development of an evaluation model for asbestos exposure risk. The spatial analysis of asbestos exposure risk is based on a weighted-overlay analysis using expert opinion and the literature, and a fuzzy-overlay analysis using the uncertainty in the data. The map of asbestos exposure risk, compiled according to the weighted and fuzzy operations, is expected to be used to ensure safety and to reduce the risk of exposure to asbestos.

Survey and Analysis of Stakeholder Opinions on the Establishment Procedure of Safety Inspection System for Highway Construction Clients (고속도로 건설공사 발주자의 안전점검 체계구축 절차에 관한 이해관계자 설문조사 및 분석)

  • Eung Ho Park;Su Dong Lee;Kihyo Jung
    • Journal of the Korea Safety Management & Science
    • /
    • v.25 no.4
    • /
    • pp.57-65
    • /
    • 2023
  • The public safety management guidelines were introduced in 2019 and continue to be dedicated to advancing comprehensive measures for public safety management, with a primary focus on prioritizing the safety and well-being of the public within governmental institutions. To achieve this goal, our previous study developed a establishment procedure of risk assessment-based safety inspection system for public institutions that order construction projects and applied it to highway construction projects to evaluate its effectiveness. To enhance the practicality of the establishment procedure, it is essential to collect and analyze feedback from stakeholders regarding its performance and suitability. This study conducted a survey involving 200 participants who had experience with the establishment procedure, and performed statistical analyses to evaluate its performance and applicability. The survey results indicated that the participants reported a high level of satisfaction (scoring 4 and above on a 5-point Likert scale) in several areas: specialization of safety inspection items for different types of work (with a satisfaction rate of 65%), the evaluation process for safety ratings (64.5%), and their willingness to recommend the procedure to other institutions (75.5%). In the factor analysis with Varimax rotation, two factors emerged: (1) a specialization factor related to safety inspection items, and (2) a grading factor associated with safety evaluation results. Regression analyses of these factors unveiled significant positive relationships with improvements in safety and health performance, including the prevention of fatal accidents, heightened safety responsibility, and raised safety inspection standards. The establishment procedure of safety inspection system developed in our previous study can play a crucial role in reducing accidents resulting in fatalities and injuries at construction sites, ultimately contributing to a safer working environment for all involved parties.

Improvement of Safety Management and Plan by Comparison Analysis of Construction Technology Promotion Act(CTPA) and Occupational Safety and Health Act(OSHA) in Construction Field (건설기술진흥법과 산업안전보건법 비교분석을 통한 건설업 안전관리 및 계획의 개선방안)

  • Kim, Si Ouk;Yoon, Young Geun;Oh, Tae Keun
    • Journal of the Korean Society of Safety
    • /
    • v.36 no.4
    • /
    • pp.37-46
    • /
    • 2021
  • According to the Korean Statistical Information Service, the number of fatal occupational accidents per 100,000 workers is the highest in Korea, among all the OECD countries. The safety of construction workers is managed by the construction technology promotion act (CTPA) and the occupational safety and health act (OHSA). A review of the current safety management laws is required to improve them for the construction industry, where the numbers of accidents and deaths are constantly increasing. Accordingly, the aim of this study was to identify the problems in unclear business areas through comparison and analysis of the CTPA and OHSA guidelines and establish effective site-dependent construction safety management plans. The overlapping safety and health management terms and tasks of organizations were derived along with identifying the overlapping items of the safety management and hazard and risk prevention plans. Based on these results, several improvements for the design stage, safety cost, and safety education have been suggested in this paper. In addition, an improved model based on the integration and an optimized compromise between these two laws for safety management in areas where many accidents have occurred in recent years has been reported here.

A Study on Safety Improvement for Mobile Hydrogen Refueling Station by HAZOP Analysis (위험과 운전 분석을 통한 이동식 수소충전소 안전성 향상에 관한 연구)

  • BYUN, YOON-SUP
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.32 no.5
    • /
    • pp.299-307
    • /
    • 2021
  • In order to expand the supply of hydrogen vehicles, the first thing to be done is to build an infrastructure to supply hydrogen. There are fixed and mobile types of hydrogen refueling stations that can supply hydrogen. Mobile hydrogen refueling stations have the advantage of supplying hydrogen to two or three areas, so the introduction of mobile hydrogen refueling stations is considered at the initial stage of hydrogen vehicle dissemination. However, mobile hydrogen refueling stations have greater risks than fixed hydrogen refueling stations due to the hazard associated with movement and intensive installation of facilities in vehicle, so stricter design standards to lower the risk must be applied. Therefore, in this study, basic data for establishing safety standards for mobile hydrogen refueling stations were proposed by suggesting improvements such as the location of emergency shutoff valves, the number of gas detectors etc., using HAZOP analysis.

A Study on the Measurement and Comparison(IEC 60079-32-2) of Flammable Liquid Conductivity (인화성 액체 도전율에 관한 측정 및 비교(IEC 60079-32-2) 연구)

  • Lee, Dong Hoon;Byeon, Junghwan
    • Journal of the Korean Society of Safety
    • /
    • v.34 no.4
    • /
    • pp.22-31
    • /
    • 2019
  • The flammable liquid conductivity is an important factor in determining the generation of electrostatic in fire and explosion hazardous areas, so it is necessary to study the physical properties of flammable liquids. In particular, the relevant liquid conductivity in the process of handling flammable liquids in relation to the risk assessment and risk control in fire and explosion hazard areas, such as chemical plants, is classified as a main evaluation item according to the IEC standard, and it is necessary to have flammable liquid conductivity measuring devices and related data are required depending on the handling conditions of the material, such as temperature and mixing ratio for preventing the fire and explosion related to electrostatic. In addition, IEC 60079-32-2 [Explosive Atmospheres-Part 32-2 (Electrostatic hazards-Tests)] refers to the measuring device standard and the conductivity of a single substance. It was concluded that there is no measurement data according to the handling conditions such as mixing ratio of flammable liquid and temperature together with the use and measurement examples. We have developed the measurement reliability by improving the structure, material and measurement method of measuring device by referring to the IEC standard. We have developed a measurement device that is developed and manufactured by itself. The test results of flammable liquid conductivity measurement and the data of the NFPA 77 (Recommended Practice on Static Electricity) Annex B Table B.2 Static Electric Characteristic of Liquids were compared and verified by conducting the conductivity measurement of the flammable liquid handled in the fire and explosion hazardous place by using Measuring / Data Acquisition / Processing / PC Communication. It will contribute to the prevention of static electricity related disaster by taking preliminary measures for fire and explosion prevention by providing technical guidance for static electricity risk assessment and risk control through flammable liquid conductivity measurement experiment. In addition, based on the experimental results, it is possible to create a big data base by constructing electrostatic physical characteristic data of flammable liquids by process and material. Also, it is analyzed that it will contribute to the foundation composition for adding the specific information of conductivity of flammable liquid to the physical and chemical characteristics of MSDS.

A Study on the Improvement Plan of Electrostatic Safety Management Level through Injury Analysis (재해분석을 통한 정전기 안전관리 수준 향상 방안 연구)

  • Choi, Sang-won;Jeong, Seong-Choon;Park, Jae Suk;Yang, Jeong Yeol;Byeon, Junghwan
    • Journal of the Korean Society of Safety
    • /
    • v.34 no.5
    • /
    • pp.37-45
    • /
    • 2019
  • The characteristic of fire and explosion related to electrostatic discharge is that it is difficult to reproduce the electrostatic charge and discharge phenomenon in addition to the large human and material damage. Therefore, in order to prevent accidents and disasters related to electrostatic in fire and explosion hazard areas, it is important to manage the level of electrostatic in a safe manner from the perspective of system between industrial facilities and human bodies. Rule 325 of the Occupational Safety and Health Regulations, "Prevention of Fire / Explosion due to Electrostatic", requires the use of grounding, conductive materials, humidification and electrification in order to prevent the risk of disaster caused by static explosion and electrostatic in the production process. In order to comply with these measures, related technologies, standards and systems are needed from the viewpoint of preventive measures related to electrostatic in fire and explosion hazard areas, but in Korea, it is still insufficient. Therefore, technical, institutional and managerial measures are needed as a precautionary measure to improve the level of ESD safety in fire and explosion hazard areas and prevent electrostatic related injury. In Korea, we analyzed the current status and characteristics of electrostatic related disaster by using the statistics of industrial accident and fire statistics of the Ministry of Employment and Labor. We also analyzed the current status and characteristics of electrostatic related disasters in Japan using JNIOSH accidents and disasters investigation cases and JNIOSH fire accident data of Japan Fire Bureau. The purpose of this study is to compare and analyze the current status of electrostatic related accidents and disasters in Korea and Japan in order to improve the safety management of electrostatic in fire and explosion hazard areas. In order to prevent accidents and disasters in the industrial field, The technical, institutional, and managerial measures to manage the level of electrostatic in a safe state were derived from the system point of view.

Technical/Systemic Approach to Safety Assesment of Thermoprocessing Equipment Consuming LNG for Classification of Hazardous Area (LNG를 사용하는 설비에서의 폭발위험장소 적용 및 구분에 대한 제도/기술적 접근방안)

  • Choi, Sang-Won
    • Journal of the Korean Society of Safety
    • /
    • v.26 no.5
    • /
    • pp.33-40
    • /
    • 2011
  • In the hazardous areas where explosive liquids, vapors and gases exist, electrical apparatus/equipment should have explosion-proof construction. The consuming of liquefied natural gas(LNG) has markedly increased in the industrial field, especially in aspect of some thermoprocessing equipment, boiler, dryer, furnace, annealer, kiln, regenerative thermal oxidizer(RTO) and so on. Because it has many merits, clean fuel, safety, no transportation/storage facility and so on. It is strongly recommend that the classification of hazards has to be decided to prevent and protect explosion which may occur in thermoprocessing equipment. In this paper, the operated thermoprocessing equipments in industrial area investigated and explosion risk assessment about LNG leakage from its facilities was performed through numerical calculation and computer simulation. Finally, we suggest the systemic/technical approach for safety assessments of thermoprocessing equipments consumed LNG fuel which are specially subjected to classification of hazardous area.

How do the work environment and work safety differ between the dry and wet kitchen foodservice facilities?

  • Chang, Hye-Ja;Kim, Jeong-Won;Ju, Se-Young;Go, Eun-Sun
    • Nutrition Research and Practice
    • /
    • v.6 no.4
    • /
    • pp.366-374
    • /
    • 2012
  • In order to create a worker-friendly environment for institutional foodservice, facilities operating with a dry kitchen system have been recommended. This study was designed to compare the work safety and work environment of foodservice between wet and dry kitchen systems. Data were obtained using questionnaires with a target group of 303 staff at 57 foodservice operations. Dry kitchen facilities were constructed after 2006, which had a higher construction cost and more finishing floors with anti-slip tiles, and in which employees more wore non-slip footwear than wet kitchen (76.7%). The kitchen temperature and muscular pain were the most frequently reported employees' discomfort factors in the two systems, and, in the wet kitchen, "noise of kitchen" was also frequently reported as a discomfort. Dietitian and employees rated the less slippery and slip related incidents in dry kitchens than those of wet kitchen. Fryer area, ware-washing area, and plate waste table were the slippery areas and the causes were different between the functional areas. The risk for current leakage was rated significantly higher in wet kitchens by dietitians. In addition, the ware-washing area was found to be where employees felt the highest risk of electrical shock. Muscular pain (72.2%), arthritis (39.1%), hard-of-hearing (46.6%) and psychological stress (47.0%) were experienced by employees more than once a month, particularly in the wet kitchen. In conclusion, the dry kitchen system was found to be more efficient for food and work safety because of its superior design and well managed practices.