• Title/Summary/Keyword: Risk monitor

Search Result 350, Processing Time 0.039 seconds

Bivalvation Valvuloplasty for Common Atrioventricular Valve Regurgitation in Functional Single Ventricle; Early and Mid-term Results (기능적 단심설에서 공통방실판 역류의 판막성형술; 판막 이분성형술(bivalvation)의 조기 및 중기 결과)

  • Chang, Yun-Hee;Sung, Si-Chan;Kim, Seon-Hee;Lee, Hyoung-Doo;Ban, Ji-Eun
    • Journal of Chest Surgery
    • /
    • v.42 no.5
    • /
    • pp.597-603
    • /
    • 2009
  • Background: Atrioventricular valve regurgitation in pediatric patients with a functional single ventricles (FSV) - has been known as one of the important risk factors for death and unfavorable long-term results after a Fontan operation. We evaluated early and mid-term results of bivalvation valvuloplasty in FSV patients. Material and Method: We retrospectively evaluated 11 patients with a functional single ventricle who underwent bivalvationvalvuloplasty between 1999 and 2007. The degree of common atrioventricular valve regurgitation (CAVVR) was determined by color Doppler echocardiography (regurgitation grade scoring, trivial; 1, mild; 2, moderate; 3, severe; 4). Mean age at valve surgery was $6.9{\pm}7.0$ months (median 4 months, 24 days$\sim$21 months)and mean body weight was $6.2{\pm}2.8\;kg$ ($3.1{\sim}11.3\;kg$). Nine patients had isomerism heart and two of them had TAPVC. The concomitant procedures were performed in all but one patient. Additional commissural closure was performed in 3 patients and commissural annuloplasty in another 3 patients. Result: There was one hospital death after. surgery. A 32-day old patient who had been preoperatively dependent on a ventilator died of air way and lung problems 4.3 months after pulmonary artery banding and bivalvation valvuloplasty. Mean follow-up duration was 40 months ($4.3{\sim}114$ months). Mean preoperative CAVVR score was $3.3{\pm}0.6$, which decreased to $1.9{\pm}0.7$ postoperatively (p<0.0001). This residual regurgitation slightly increased to $2.2{\pm}0.4$ (no statistical significance) after a mean follow-up of 1.4.3 months. Six patients (60%) required re-operations for residual regurgitation at a subsequent bidirectionalcavopulmonary shunt or Fontan operation. One patient with Ebsteinoid malformation of the right sided atrioventricular valve required valve replacement due to stenoinsufficiency. Another patient required edge-to-edge repair at the right sided AV valve (between the right mural leaflet and the bridging leaflets). The remaining 4 patients required additional suture placements between bridging leaflets with or without commissural annuloplasty. All survivor had trivial or mild CAVVR at the latest follow-up. Conclusion: Bivalvation valvuloplasty for CAVVR in FSV patients is. an effective and safe procedure. However, significant numbers of the patients have small residual regurgitation and require additional valve procedures at subsequent operations. Long-term observations to monitor progression of the CAVVR is mandatory.

How to Reflect Sustainable Development, exemplified by the Equator Principles, in Overseas Investment (해외투자(海外投資)와 지속가능발전 원칙 - 프로젝트 파이낸스의 적도원칙(赤道原則)을 중심으로 -)

  • Park, Whon-Il
    • THE INTERNATIONAL COMMERCE & LAW REVIEW
    • /
    • v.31
    • /
    • pp.27-56
    • /
    • 2006
  • Today's financial institutions usually take environmental issues seriously into consideration as they could not evade lender liability in an increasing number of cases. On the international scene, a brand-new concept of the "Equator Principles" in the New Millenium has driven more and more international banks to adopt these Principles in project financing. Sustainable development has been a key word in understanding new trends of the governments, financial institutions, corporations and civic groups in the 21st century. The Equator Principles are a set of voluntary environmental and social guidelines for sustainable finance. These Principles commit bank officers to avoid financial support to projects that fail to meet these guidelines. The Principles were conceived in 2002 on an initiative of the International Finance Corporation(IFC), and launched in June 2003. Since then, dozens of major banks, accounting for up to 80 percent of project loan market, have adopted the Principles. Accordingly, the Principles have become the de facto standard for all banks and investors on how to deal with potential social and environmental issues of projects to be financed. Compliance with the Equator Principles facilitates for endorsing banks to participate in the syndicated loan and help them to manage the risks associated with large-scale projects. The Equator Principles call for financial institutions to provide loans to projects under the following circumstances: - The risk of the project is categorized in accordance with internal guidelines based upon the environmental and social screening criteria of the IFC. - For Category A and B projects, borrowers or sponsors are required to conduct a Social and Environmental Assessment, the preparation of which must meet certain requirements and satisfactorily address key social and environmental issues. - The Social and Environmental Assessment report should address baseline social and environmental conditions, requirements under host country laws and regulations, sustainable development, and, as appropriate, IFC's Environmental, Health and Safety Guidelines, etc. - Based on the Social and Environmental Assessment, Equator banks then make agreements with borrowers on how they mitigate, monitor and manage the risks through a Social and Environmental Management System. Compliance with the plan is included in the covenant clause of loan agreements. If the borrower doesn't comply with the agreed terms, the bank will take corrective actions. The Equator Principles are not a mere declaration of cautious banks but a full commitment of lenders. A violation of the Principles in the process of project financing, which led to an unexpected damage to the affected community, would not give rise to any specific legal remedies other than ordinary lawsuits. So it is more effective for banks to ensure consistent implementation of the Principles and to have them take responsible measures to solve social and environmental issues. Public interests have recently mounted up with respect to environmental issues on the occasion of the Supreme Court's decision (2006Du330) on the fiercely debated reclamation project at Saemangeum. The majority Justices said that the expected environmental damages like probable pollution of water and soil were not believed so serious and that the Administration should continue to implement the project seeking ways to make it more environment friendly. In this case, though the Category A Saemangeum Project was carried out by a government agency, the Supreme Court behaved itself as a signal giver to approve or stop the environment-related project like an Equator bank in project financing. At present, there is no Equator bank in Korea in contrast to three big banks in Japan. Also Korean contractors, which are aggressively bidding for Category A-type projects in South East Asia and Mideast, might find themselves in a disadvantageous position because they are generally ignorant of the environmental assessment associated with project financing. In this regard, Korean banks and overseas project contractors should care for the revised Equator Principles and the latest developments in project financing more seriously. It's because its scope has expanded to the capital cost of US$10 million or more across all industry sectors regardless of developing countries or not. It should be noted that, for a Korean bank, being an Equator bank is more or less burdensome in a short-term period, but it must be conducive to minimizing risks and building up good reputation in the long run.

  • PDF

Monitoring of pesticide residues in commercial agricultural products in the northern area of Seoul, Korea (서울 북부지역 유통 농산물의 농약 잔류실태)

  • Han, Sung-Hee;Park, Sung-Kyu;Kim, Ouk-Hee;Choi, Young-Hee;Seoung, Hyun-Jung;Lee, Young-Ju;Jung, Jung-Hee;Kim, Yun-Hee;Yu, In-Sil;Kim, Yoo-Kyung;Han, Ki-Young;Chae, Young-Zoo
    • The Korean Journal of Pesticide Science
    • /
    • v.16 no.2
    • /
    • pp.109-120
    • /
    • 2012
  • This study was conducted to monitor 284 pesticides residue level in 2,914 commercial agricultural products in the northern area of Seoul in 2011 by the multi class pesticide multiresidue analysis methods in Korea Food Code using GC, HPLC, GC-MSD and, LC-MSD. The detection rate of pesticide residues were 14.8% (431/2,914). The order of agricultural products in which the pesticide residues were detected was perilla leaves 40.0% (28/70), chamnamul 35.5% (11/31), amaranth 30.0% (3/10) and spinach 27.7% (38/137) etc. The percentage of products that exceeded the MRLs (maximum residue limits) were 1.0% (31/431). Those products that exceeded MRLs were ginseng (6), perilla leaves (4), leek (4), welsh onion (3) and sedeum (3) etc. The 59 kinds of the pesticides were detected on this study, 21 pesticides of them were detected over MRLs. Detection rate of fungicides (56.4%) was higher than that of insecticides (42.1%). And procymidone was detected with considerable high frequency. Additionally, residual residual violates pesticides were in the order of tolclofos-methyl, endosulfan, dimethomorph, diniconazole and fludioxonil. According to the agricultural marketing channels, detection and excess rate of them were monitored. Detection and excess rate of samples circulated in agricultural traditional market were highest. The estimated daily intakes (EDI) of the pesticides were compared to personal acceptable daily intakes (PADI) in order to risk assessment by food consumption. Diazinon in Korean cabbage showed the highest %ADI, 2.9901 and others showed below 3.0 %ADI. Overall, these results indicate that residue levels of pesticides detected were evaluated as safe.

Comparison of Anisotropic Analytic Algorithm Plan and Acuros XB Plan for Lung Stereotactic Ablative Radiotherapy Using Flattening Filter-Free Beams (비편평화여과기 빔을 이용한 폐 정위절제방사선치료를 위한 AAA와 Acuros XB 계산 알고리즘의 치료계획 비교)

  • Chung, Jin-Beom;Eom, Keun-Yong;Kim, In-Ah;Kim, Jae-Sung;Lee, Jeong-Woo;Hong, Semie;Kim, Yon-Lae;Park, Byung-Moon;Kang, Sang-Won;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.25 no.4
    • /
    • pp.210-217
    • /
    • 2014
  • This study investigated the dosimetric effects of different dose calculation algorithm for lung stereotactic ablative radiotherapy (SABR) using flattening filter-free (FFF) beams. A total of 10 patients with lung cancer who were treated with SABR were evaluated. All treatment plans were created using an Acuros XB (AXB) of an Eclipse treatment planning system. An additional plans for comparison of different alagorithm recalcuated with anisotropic analytic algorithm (AAA) algorithm. To address both algorithms, the cumulative dose-volume histogram (DVH) was analyzed for the planning target volume (PTV) and organs at risk (OARs). Technical parameters, such as the computation times and total monitor units (MUs), were also evaluated. A comparison analysis of DVHs from these plans revealed the PTV for AXB estimated a higher maximum dose (5.2%) and lower minimum dose (4.2%) than that of the AAA. The highest dose difference observed 7.06% for the PTV $V_{105%}$. The maximum dose to the lung was also slightly larger in the AXB plans. The percentate volumes of the ipsilateral lung ($V_5$, $V_{10}$, $V_{20}$) receiving 5, 10, and 20 Gy were also larger in AXB plans than for AAA plans. However, these parameters were comparable between both AAA and AXB plans for the contralateral lung. The differences of the maximum dose for the spinal cord and heart were also small. The computation time of AXB plans was 13.7% shorter than that of AAA plans. The average MUs were 3.47% larger for AXB plans than for AAA plans. The results of this study suggest that AXB algorithm can provide advantages such as accurate dose calculations and reduced computation time in lung SABR plan using FFF beams, especially for volumetric modulated arc therapy technique.

Estimation of Secondary Scattered Dose from Intensity-modulated Radiotherapy for Liver Cancer Cases (간암환자에 대한 세기조절방사선치료에서의 2차 산란선량평가)

  • Kim, Dong Wook;Sung, Jiwon;Lee, Hyunho;Yoon, Myonggeun;Chung, Weon Kuu;Bae, Sun Hyun;Shin, Dong Oh;Chung, Kwangzoo;Lim, Young Kyung;Shin, Donho;Lee, Se Byeong
    • Progress in Medical Physics
    • /
    • v.24 no.4
    • /
    • pp.295-302
    • /
    • 2013
  • We estimated secondary scattered and leakage doses for intensity-modulated radiotherapy (IMRT), volumetric arc therapy (VMAT) and tomotherapy (TOMO) in patients with liver cancer. Five liver patients were planned by IMRT, VMAT and TOMO. Secondary scatter (and leakage) dose and organ equivalent doses (OEDs) are measured and estimated at various points 20 to 80 cm from the iso-center by using radiophotoluminescence glass dosimeter (RPLGD). The secondary dose per Gy from IMRT, VMAT and TOMO for liver cancer, measured 20 to 80 cm from the iso-center, are 0.01~3.13, 0.03~2.34 and 0.04~1.29 cGy, respectively. The mean values of relative OED of secondary dose of VMAT and TOMO for five patients, which is normalized by IMRT, measured as 75.24% and 50.92% for thyroid, 75.14% and 40.61% for bowel, 72.30% and 47.77% for rectum, 76.21% and 49.93% for prostate. The secondary dose and OED from TOMO is relatively low to those from IMRT and VMAT. OED based estimation suggests that the secondary cancer risk from TOMO is less than or comparable to the risks from conventional IMRT and VMAT.

Features and Trends of IEC Particular Standards for Medical Equipment Related to Diagnostic X-ray Based on IEC 60601-1:2005 Ed. 3.0 (IEC 60601-1: 3판이 적용된 진단용 X선장치 관련 개별규격의 동향 및 특징)

  • Kim, Hyun-Ji;Kim, Jung-Min;Choi, In-Seok;Yoon, Yong-Su;Seo, Deok-Nam;Kim, Jung-Su;Kim, Dae-Young;Park, Sung-Yong
    • Journal of radiological science and technology
    • /
    • v.36 no.1
    • /
    • pp.1-10
    • /
    • 2013
  • IEC publications have applied in many countries all over the world such as Europe or Japan and these also have been published as in dustrial standards (KS) and notifications of Korea Food and Drug Administration (KFDA) in Korea. As the general standard of IEC 60601 series for medical electric (ME) equipment was revised as $3^{rd}$ edition in 2005, additional and particular standards have been revised or established newly. Under these circumstances, it is importance for manufacturing and assembling companies or authorized testing companies to understand the trend for revisions of IEC publications. Therefore in this study, the latest version of 3 IEC standards related to medical X-ray equipment : IEC 60601-2-44 for X-ray equipment for computed tomography (CT), IEC 60601-2-45 for mammographic X-ray equipment and IEC 60601-2-54 for X-ray equipment for radiography or radioscopy were covered and analyzed for trends and features accompanied by revision based on IEC 60601-1 $3^{rd}$ Ed. As KFDA notifications in force have referred to the particular standards based on 2nd edition of IEC 60601-1, those revised version of 3 particular standards were compared to KFDA notifications in force. The features of the latest standards applying IEC 60601-1 $3^{rd}$ Ed were shown as following: 1) Requirements for mechanical hazards, especially (motorized) moving parts were emphasized. 2) Indication and recording of patient dose were required. 3) Risk management process was introduced and enabled to monitor potential risks systematically. 4) DR system (digital radiography system) as well as analogue system (film-screen system) was included in the scope. Presently, KFDA will revise the notifications applying the particular standards based on IEC 60601-1 $3^{rd}$ Ed in a few years. Therefore the features of particular standards applying IEC 60601-1 $3^{rd}$ Ed was expected to help manufacturers, assemblers or testing companies of medical electric equipment understand IEC publications or KFDA notifications slated to be published.

Impacts of Diastolic Function on Clinical Outcomes in Young Patients with Acute Myocardial Infarction (젊은 급성 심근경색증 환자에서 좌심실 이완 기능 및 충만압이 관상동맥중재술 후 임상 경과에 미치는 영향)

  • Cho, Eun Young;Jeong, Myung Ho;Yoon, Hyun Ju;Kim, Yong Cheol;Sohn, Seok-Joon;Kim, Min Chul;Sim, Doo Sun;Hong, Young Joon;Kim, Ju Han;Ahn, Youngkeun;Cho, Jae Young;Kim, Kye Hun;Park, Jong Chun
    • The Korean Journal of Medicine
    • /
    • v.93 no.6
    • /
    • pp.538-547
    • /
    • 2018
  • Background/Aims: The impact of left ventricular (LV) diastolic function and filling pressure on clinical outcomes in young patients with acute myocardial infarction (AMI) has been poorly studied. Therefore, the aim of this study was to investigate the impact of LV diastolic function and LV filling pressure on major adverse cardiac events (MACEs) in young patients with AMI. Methods: A total of 200 young patients (males < 45 year, females < 55 year) with AMI were divided into two groups according to the diastolic function; normal (n = 46, $39.5{\pm}5.3$ years) versus abnormal (n = 154, $43.5{\pm}5.1$ years). Results: Despite regional wall motion abnormalities, normal LV diastolic function was not uncommon in young AMI patients (23.0%). During the 40 months of clinical follow-up, MACEs developed in 26 patients (13.0%); 14 re-percutaneous coronary intervention (7.0%), 8 recurrent MI (4.0%), and 4 deaths (2.0%). MACEs did not differ between the normal and abnormal diastolic function group (13.6% vs. 10.9%, p = 0.810), but MACEs were significantly higher in the high LV filling pressure group than the normal LV filling pressure group (36.8% vs. 10.5%, p < 0.001). On multivariate analysis, high LV filling pressure was an independent predictor of MACEs (hazard ratio 3.022, 95% confidence interval 1.200-7.612, p = 0.019). Conclusions: This study suggested that measurement of the LV filling pressure (E/e' ratio) would be useful in the risk stratification of young patients with AMI. However, it would be necessary to monitor this category of patient more carefully.

Frequency of Candida Strains Isolated from Candidiasis Patients at A Tertiary Hospital over the Last 10 Years (최근 10년 동안 일개 상급종합병원의 칸디다혈증 환자에서 분리된 칸디다 균종의 빈도)

  • Hwang, Yu-Yean;Kang, On-Kyun;Park, Chang-Eun;Hong, Sung-No;Kim, Young-Kwon;Huh, Hee-Jae;Lee, Nam-Yong
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.54 no.2
    • /
    • pp.110-118
    • /
    • 2022
  • Candidemia is a major cause of nosocomial infections resulting in increased morbidity and mortality. It remains a serious risk in inpatients and increases medical treatment costs. From 2009 to 2018, Candida strains (3,533) isolated from blood culture tests at the S Hospital were analyzed according to the period, year, sex, age, ward, etc. During the entire period, 54,739 of 717,996 blood culture tests showed a positive rate (7.6%) and the Candida isolation rate was 3,533 (6.4%) out of 1,036 patients. Among the Candida isolates, C. albicans was most common (33.8%), followed by C. tropicalis (28.6%), C. glabrata (19.8%), C. parapsilosis (7.8%), and C. krusei (4.0%). In early (2009~2013)/late (2014~2018) isolation, C. tropicalis decreased by 3.8% and C. glabrata increased by 3.4%. After 50 years of age, the higher the separation frequency. C. parapsilosis (31.3%) in 1~10s, C. tropicalis (30.3%) and C. glabrata (27.6%) in 41~50s, and C. tropicalis (28.6%) in 80s are relatively frequent. has been separated C. krusei was isolated in a relatively high proportion from females (60.9%). Therefore, a systematic and continuous nosocomial infection control system should be established for appropriate treatment as per antifungal treatment guidelines. The system should continuously monitor the distribution of Candida species and provide rapid identification results.

Electronic Roll Book using Electronic Bracelet.Child Safe-Guarding Device System (전자 팔찌를 이용한 전자 출석부.어린이 보호 장치 시스템)

  • Moon, Seung-Jin;Kim, Tae-Nam;Kim, Pan-Su
    • Journal of Intelligence and Information Systems
    • /
    • v.17 no.4
    • /
    • pp.143-155
    • /
    • 2011
  • Lately electronic tagging policy for the sexual offenders was introduced in order to reduce and prevent sexual offences. However, most sexual offences against children happening these days are committed by the tagged offenders whose identities have been released. So, for the crime prevention, we need measures with which we could minimize the suffers more promptly and actively. This paper suggests a new system to relieve the sexual abuse related anxiety of the children and solve the problems that electronic bracelet has. Existing bracelets are only worn by serious criminals, and it's only for risk management and positioning, there is no way to protect the children who are the potential victims of sexual abuse and there actually happened some cases. So we suggest also letting the students(children) wear the LBS(Location Based Service) and USN(Ubiquitous Sensor Network) technology based electronic bracelets to monitor and figure out dangerous situations intelligently, so that we could prevent sexual offences against children beforehand, and while a crime is happening, we could judge the situation of the crime intelligently and take swift action to minimize the suffer. And by checking students' attendance and position, guardians could know where their children are in real time and could protect the children from not only sexual offences but also violent crimes against children like kidnapping. The overall system is like follows : RFID Tag for children monitors the approach of offenders. While an offender's RFID tag is approaching, it will transmit the situation and position as the first warning message to the control center and the guardians. When the offender is going far away, it turns to monitoring mode, and if the tag of the child or the offender is taken off or the child and offender stay at one position for 3~5 minutes or longer, then it will consider this as a dangerous situation, then transmit the emergency situations and position as the second warning message to the control center and the guardians, and ask for the dispatch of police to prevent the crime at the initial stage. The RFID module of criminals' electronic bracelets is RFID TAG, and the RFID module for the children is RFID receiver(reader), so wherever the offenders are, if an offender is at a place within 20m from a child, RFID module for children will transmit the situation every certain periods to the control center by the automatic response of the receiver. As for the positioning module, outdoors GPS or mobile communications module(CELL module)is used and UWB, WI-FI based module is used indoors. The sensor is set under the purpose of making it possible to measure the position coordinates even indoors, so that one could send his real time situation and position to the server of central control center. By using the RFID electronic roll book system of educational institutions and safety system installed at home, children's position and situation can be checked. When the child leaves for school, attendance can be checked through the electronic roll book, and when school is over the information is sent to the guardians. And using RFID access control turnstiles installed at the apartment or entrance of the house, the arrival of the children could be checked and the information is transmitted to the guardians. If the student is absent or didn't arrive at home, the information of the child is sent to the central control center from the electronic roll book or access control turnstiles, and look for the position of the child's electronic bracelet using GPS or mobile communications module, then send the information to the guardians and teacher so that they could report to the police immediately if necessary. Central management and control system is built under the purpose of monitoring dangerous situations and guardians' checking. It saves the warning and pattern data to figure out the areas with dangerous situation, and could help introduce crime prevention systems like CCTV with the highest priority. And by DB establishment personal data could be saved, the frequency of first and second warnings made, the terminal ID of the specific child and offender, warning made position, situation (like approaching, taken off of the electronic bracelet, same position for a certain time) and so on could be recorded, and the data is going to be used for preventing crimes. Even though we've already introduced electronic tagging to prevent recurrence of child sexual offences, but the crimes continuously occur. So I suggest this system to prevent crimes beforehand concerning the children's safety. If we make electronic bracelets easy to use and carry, and set the price reasonably so that many children can use, then lots of criminals could be prevented and we can protect the children easily. By preventing criminals before happening, it is going to be a helpful system for our safe life.

The Effect of External PEEP on Work of Breathing in Patients with Auto-PEEP (Auto-PEEP이 존재하는 환자에서 호흡 일에 대한 External PEEP의 효과)

  • Chin, Jae-Yong;Lim, Chae-Man;Koh, Youn-Suck;Park, Pyung-Whan;Choi, Jong-Moo;Lee, Sang-Do;Kim, Woo-Sung;Kim, Dong-Soon;Kim, Won-Dong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.43 no.2
    • /
    • pp.201-209
    • /
    • 1996
  • Background : Auto-PEEP which develops when expiratory lung emptying is not finished until the beginning of next inspiration is frequently found in patients on mechanical ventilation. Its presence imposes increased risk of barotrauma and hypotension, as well as increased work of breathing (WOB) by adding inspiratory threshold load and/or adversely affecting to inspiratory trigger sensitivity. The aim of this study is to evaluate the relationship of auto-PEEP with WOB and to evaluate the effect of PEEP applied by ventilator (external PEEP) on WOB in patients with auto-PEEP. Method : 15 patients, who required mechanical ventilation for management of acute respiratory failure, were studied. First, the differences in WOB and other indices of respiratory mechanics were examined between 7 patients with auto-PEEP and 8 patients without auto-PEEP. Then, we applied the 3 cm $H_2O$ of external PEEP to patients with auto-PEEP and evaluated its effects on lung mechanics as well as WOB. Indices of respiratory mechanics including tidal volume ($V_T$), repiratory rate, minute ventilation ($V_E$), peak inspiratory flow rate (PIFR), peak expiratory flow rate (PEFR), peak inspiratory pressure (PIP), $T_I/T_{TOT}$, auto-PEEP, dynamic compliance of lung (Cdyn), expiratory airway resistance (RAWe), mean airway resistance (RAWm), $p_{0.1}$, work of breathing performed by patient (WOB), and pressure-time product (PTP) were obtained by CP-100 Pulmonary Monitor (Bicore, USA). The values were expressed as mean $\pm$ SEM (standard error of mean). Results : 1) Comparison of WOB and other indices of respiratory mechanics in patients with and without auto-PEEP : There was significant increase in WOB ($l.71{\pm}0.24$ vs $0.50{\pm}0.19\;J/L$, p=0.007), PTP ($317{\pm}70$ vs $98{\pm}36\;cm$ $H_2O{\cdot}sec/min$, p=0.023), RAWe ($35.6{\pm}5.7$ vs $18.2{\pm}2.3\;cm$ H2O/L/sec, p=0.023), RAWm ($28.8{\pm}2.5$ vs $11.9{\pm}2.0cm$ H2O/L/sec, p=0.001) and $P_{0.1}$ ($6.2{\pm}1.0$ vs 2.9+0.6 cm H2O, p=0.021) in patients with auto-PEEP compared to patients without auto-PEEP. The differences of other indices including $V_T$, PEFR, $V_E$ and $T_I/T_{TOT}$ showed no significance. 2) Effect of 3 cm $H_2O$ external PEEP on respiratory mechanics in patients with auto-PEEP : When 3 cm $H_2O$ of external PEEP was applied, there were significant decrease in WOB ($1.71{\pm}0.24$ vs $1.20{\pm}0.21\;J/L$, p=0.021) and PTP ($317{\pm}70$ vs $231{\pm}55\;cm$ $H_2O{\cdot}sec/min$, p=0.038). RAWm showed a tendency to decrease ($28.8{\pm}2.5$ vs $23.9{\pm}2.1\;cm$ $H_2O$, p=0.051). But PIP was increased with application of 3 cm $H_2O$ of external PEEP ($16{\pm}2$ vs $22{\pm}3\;cm$ $H_2O$, p=0.008). $V_T$, $V_E$, PEFR, $T_I/T_{TOT}$ and Cdyn did not change significantly. Conclusion : The presence of auto-PEEP in mechanically ventilated patients was accompanied with increased WOB performed by patient, and this WOB was decreased by 3 cm $H_2O$ of externally applied PEEP. But, with 3 cm $H_2O$ of external PEEP, increased PIP was noted, implying the importance of close monitoring of the airway pressure during application of external PEEP.

  • PDF