• Title/Summary/Keyword: Ripple rejection design

Search Result 9, Processing Time 0.028 seconds

Double Boost Power-Decoupling Topology Suitable for Low-Voltage Photovoltaic Residential Applications Using Sliding-Mode Impedance-Shaping Controller

  • Tawfik, Mohamed Atef;Ahmed, Ashraf;Park, Joung-Hu
    • Journal of Power Electronics
    • /
    • v.19 no.4
    • /
    • pp.881-893
    • /
    • 2019
  • This paper proposes a practical sliding-mode controller design for shaping the impedances of cascaded boost-converter power decoupling circuits for reducing the second order harmonic ripple in photovoltaic (PV) current. The cascaded double-boost converter, when used as power decoupling circuit, has some advantages in terms of a high step-up voltage-ratio, a small number of switches and a better efficiency when compared to conventional topologies. From these features, it can be seen that this topology is suitable for residential (PV) rooftop systems. However, a robust controller design capable of rejecting double frequency inverter ripple from passing to the (PV) source is a challenge. The design constraints are related to the principle of the impedance-shaping technique to maximize the output impedance of the input-side boost converter, to block the double frequency PV current ripple component, and to prevent it from passing to the source without degrading the system dynamic responses. The design has a small recovery time in the presence of transients with a low overshoot or undershoot. Moreover, the proposed controller ensures that the ripple component swings freely within a voltage-gap between the (PV) and the DC-link voltages by the small capacitance of the auxiliary DC-link for electrolytic-capacitor elimination. The second boost controls the main DC-link voltage tightly within a satisfactory ripple range. The inverter controller performs maximum power point tracking (MPPT) for the input voltage source using ripple correlation control (RCC). The robustness of the proposed control was verified by varying system parameters under different load conditions. Finally, the proposed controller was verified by simulation and experimental results.

Optimization of the Withdrawal Weighting SAW Filter (Withdrawal Weighting SAW 필터의 최적 설계)

  • 이영진;노용래
    • The Journal of the Acoustical Society of Korea
    • /
    • v.18 no.4
    • /
    • pp.23-30
    • /
    • 1999
  • In this study, we propose a new optimization algorithm for a withdrawal weighted SAW transversal filter to satisfy given, specifications such as bandwidth, ripple, insertion loss, and sidelobe rejection level. An analysis tool for the withdrawal weighted filter has been produced by means of the delta function model, and has been applied to the design of a filter consisting of an uniform input IDT and a withdrawal weighted output IDT. This optimization algorithm consists of three routines, which eventually determines eight design parameters to satisfy the performance specifications. At the first step, the number of input and output IDT fingers and their geometrical size are determined by the insertion loss specification. At the next step, the bandwidth is controlled by the change of the IDT finger position. Finally, the sidelobe rejection level is modified through the add/skip technique of IDT fingers. The algorithm in this paper is distinct from conventional techniques in that it can simultaneously consider all the specifications such as bandwidth, ripple, sidelobe rejection level and insertion loss, and optimize the geometry of the withdrawal weighted SAW filter.

  • PDF

Design and Fabrication of Reflective Array Type Wideband SAW Dispersive Delay Line

  • Choi Jun-Ho;Yang Jong-Won;Nah Sun-Phil;Jang Won
    • Journal of electromagnetic engineering and science
    • /
    • v.6 no.2
    • /
    • pp.110-116
    • /
    • 2006
  • A reflective array type surface acoustic wave(SAW) dispersive delay line(DDL) with high time-bandwidth at the V/UHF-band is designed and fabricated for compressive receiver applications. This type of the SAW DDL has the properties of the relative bandwidth of 20 %, the time delay of 49.89 usec, the insertion loss of 38.5 dB and the side lobe rejection of 39 dB. In comparison with a commercial SAW DDL, the insertion loss, amplitude ripple and side lobe rejection are improved by $1.5dB{\pm}0.6dB$ and 4 dB respectively. Using the fabricated SAW DDL, the prototype of the compressive receiver is developed. It is composed of RF converter, fast tunable LO, chirp LO, A/D converter, signal processing unit and control unit. This prototype system shows a fine frequency resolution of below 30 kHz with high scan rate.

Analysis and Design of Sliding Mode Control for a Single-Phase AC-DC Converter

  • Sawaengsinkasikit, Winyu;Tipsuwanporn, Vittaya;Tarasantisuk, Chanlit
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.2291-2294
    • /
    • 2003
  • In this paper, analysis and control design of ac-dc converter, normally nonlinear time-varying system, using sliding mode controller to achieve fast output voltage response, disturbance rejection and robust system in the presence of load variation are demonstrated. The objective of this method is to develop methodology for output voltage to be constant and input current sinusoidal that results in nearly unity power factor, respectively. In addition the converter can be also bidirectional power flow. Simulation results using Matlab/Simulink show the effectiveness of sliding mode control system compared with linear feedback controller to guarantee enhanced PF>0.98, THD<5%, and ripple output voltage is less than 1% at the maximum output power.

  • PDF

A Study on the Signal Processing and Robust Control for a 3-DOF Active Vibration Isolator (3자유도 능동형 제진 시스템을 위한 신호처리 및 강인제어에 관한 연구)

  • Moon, Jun-Hee;Kim, Hwa-Soo;Pahk, Heui-Jae
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.153-156
    • /
    • 2006
  • The vibration isolation system is a system that attenuates the vibration transmitted from surroundings by using external energy supply like electricity and feedback and/or feedforward functions. Such a system needs stiff structure to make precise positioning without ripple within a certain bandwidth. So, a horizontal and rotary arrangement of the actuation module is suggested by using lever linkage. Modeling and kinematic formulation are completed and system identification is accomplished to tune the design variables accurately. The vibration isolation control is performed by mu-synthesis with the uncertainties in design variables. Low frequency signal enhancement circuit and saturation proof integration algorithm are devised to use seismic sensors for displacement control. This overall system shows good disturbance rejection performance.

  • PDF

A Design of High Temperature Superconducting Low-Pass Filter for Broad-Band Harmonic Rejection (광대역 고조파 제거용 고온초전도 저역통과 필터의 설계)

  • Kwak, Min-Hwan;Kim, Sang-Hyun;Ahn, Dal;Han, Seok-Kil;Kang, Kwang-Yong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.05b
    • /
    • pp.78-81
    • /
    • 2000
  • A new type low-pass filter design method based on a coupled line and transmission line theory is proposed to suppress harmonics by attenuation poles in the stop band The design formula are derived using the equivalent circuit of a coupled transmission line. The new low-pass filter structure is shown to have attractive properties such as compact size, wide stop band range and low insertion loss. The seventh-order low-pass filter designed by present method Ins a cutoff frequency of 0.9 GHz with a 0.01 dB ripple level. The coupled line type low-pass filter with stripline configuration was fabricated by using a high-temperature superconducting (HTS ; $YBa_2Cu_3O_{7-x}$) thin film on MgO(100) substrate. Since the HTS coupled line type low-pass filter was proposed with five attenuation poles in stop band such as 1.8, 2.5, 4, 5.5, 62 GHz. The fabricated low-pass filter has improved the attenuation characteristics up to seven times of the cutoff frequency Bemuse of good rejection of the spurious signals and harmonics, our low-pass filter is applicable to mobile base station systems such as cellular, personal communication systems and international mobile telecommunication(IMT)-2000 systems.

  • PDF

Design of a Series Voltage Sag Compensation System in Transmission Line

  • Park, Hyen-Young;Kim, Yang-Mo;Lee, Gyo-Sung;Oh, Se-Ho;Park, Jung-Gyun
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.2B no.4
    • /
    • pp.191-200
    • /
    • 2002
  • When power consumption increases, power supply must be efficient and reliable for good power quality. The studies on compensation system of power quality are processing actively. Voltage sag among of factors for power quality is generally PI dual control that voltage sag compensation is used. But this control is no more available since of 120[KHz] ripple rejection. So we proposed the control algorithm using PID control in 3-phase unbalanced power system and the series voltage compensator, when voltage sag occurs.

Fabrication of high-temperature superconducting low-pass filter for broad-band harmonic rejection (광대역 고조파 제거를 위한 고온초전도 저역통과필터의 제작)

  • Han, Seok-Gil;Kang, Gwang-Yong;Ahn, Dal;Suh, Jun-Seok;Choi, Chun-Geun;Kim, Sang-Hyeon;Kwak, Min-Hwan
    • 한국초전도학회:학술대회논문집
    • /
    • v.10
    • /
    • pp.193-196
    • /
    • 2000
  • A new type low-pass filter design method based on a coupled line and transmission line theory is proposed to suppress harmonics by attenuation poles in the stop band. The design formula are derived using the equivalent circuit of a coupled transmission line. The new low-pass filter structure is shown to have attractive properties such as compact size, wide stop band range and low insertion loss. The seventh-order low-pass filter designed by present method has a cutoff frequency of 0.9 CHz with a 0.01 dB ripple level. The coupled line type low-pass filter with strip line configuration was fabricated by using a high-temperature superconducting (HTS : YBa$_2$Cu$_3$O$_{7-{\delta}}$ thin film on MgO(100) substrate. Since the HTS coupled tine type low-pass filter was proposed with five attenuation poles in stop band such as 1.8, 2.5, 4, 5.5, 6.2 GHz. The fabricated low-pass filter has improved the attenuation characteristics up to seven times of the cutoff frequency.

  • PDF

A Study on Design and Fabricate of a Intermediate Frequency Band SAW Filter (IF 대역 SAW 필터 설계 및 제작)

  • 유일현;권희두;정양희
    • The Journal of the Acoustical Society of Korea
    • /
    • v.18 no.1
    • /
    • pp.10-15
    • /
    • 1999
  • We have studied a method to design and fabricate the Intermediate Frequency(IF) band pass filter with low shape factor which is used for CDMA base station on the 35°Y-cut X-propagation Quartz substrate. In order to fabricate a device of the low shape factor for the IF SAW filter on this substrate, we employed apodization weighted type interdigital transducer(IDT) as an input and withdrawal weighted type IDT as an output by using impulse modelling method. Also, using the Kaiser-Bessel window function, we have adopted 2200pairs and 1000pairs of input and oueut IDT respectively to minimize the effect of ripple. Furthermore, the width and the space of IDT finger are 3.6 ㎛ and 3.5 ㎛ respectively. Thus, we can have optimal results when the IDT thickness is 6000Å in consideration of the ratio of SAW's wavelength while it's aperture is 2mm for impedance matching. The fabricated SAW filter for CDMA had the property of almost 115.2MHz of a center frequency, less then 1.27MHz of bandwidth, less than 1.3 of shape factor, - l5dB of out band attenuation insertion loss and -45dB of rejection band.

  • PDF