• Title/Summary/Keyword: Ring gauge

Search Result 28, Processing Time 0.024 seconds

Vibration Analysis of Bladed Disk using Non-contact Blade Vibration System

  • Joung, Kyu-Kang;Han, Chak-Heui;Kang, Suk-Chul;Kim, Yeong-Ryeon
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.03a
    • /
    • pp.871-876
    • /
    • 2008
  • The blade vibration problem of bladed disk is the most critical subject to consider since it directly affects the stable performance of the engine as well as life of the engine. Especially, due to complicated vibration pattern of the bladed disk, more effort was required for vibration analysis and test. The research of measuring the vibration of the bladed disk, using NSMS(Non-intrusive stress measurement) instead of Aeromechanics testing method requiring slip ring or telemetry system with strain gauge, was successful. These testing can report the actual stresses seen on the blades; detect synchronous resonances that are the source of high cycle fatigue(HCF) in blades; measure individual blade mis-tuning and coupled resonances in bladed disks. In order to minimize the error being created due to heat expansion, the tip timing sensor is installed parallel to the blade trailing edge, yielding optimal result. Also, when working on finite element analysis, the whole bladed disk has gone through three-dimensional analysis, evaluating the family mode. The result of the analysis matched well with the test result.

  • PDF

Changes of Vascular Contraction and Relaxation of Rat aorta under Arsenic Stress (비소 스트레스에 의한 흰쥐 대동맥의 수축과 이완반응의 변화양상)

  • 권윤정;박태규;성유진;김인겸;김중영
    • Journal of Life Science
    • /
    • v.13 no.5
    • /
    • pp.634-641
    • /
    • 2003
  • In order to examine whether arsenic, one of environmental stress, contribute to augumentation and relaxation of rat aorta, this study was performed in vivo and in vitro, using intacted or denuded rats aorta ring preparation, respectively. The carotid arterial pressure was recorded on an ink-writing physiograph(Grass Co. 79E) connected to strain gauge. The contractile response of vascular ring with or without endothelium preparation isolated from rat were determined in organ bath and was recorded on physiograph connected to isometric transducer. Vasopressin-,and phenylephrine- induced increase in arterial pressure significantly enhanced in arsenic-treated rats; increase of 19.1%, and 46.6%, respectively. Vascular contractile response was measured in vitro preparations exposed to 0, 0.5, 1, 2 and 4 mM of arsenic for 1, 3, 5 and 8 hours. The dose-vascular responses of phenylephrine augmented by increasing dose of arsenic in the strips exposed to arsenic for 8 hours, and did not augmented for 1, 3, 5 hours. The phenomenon was not affected by strips denuded endothelium. And the response of relaxation of rat aorta induced by nitroprusside was not influenced by arsenic stress, but acetylcholine was a little increased. compared to that of control. There were no significant difference in relaxation between control and arsenic treated rings with endothelium or denuded. All of the results, phenyleprine-induced vascular contraction was significantly enhanced in 4 mM arsenic-treated rat aortic rings compared with control, whether endothelium was present or denuded at 8 hours after arsenic treatment. It may be a mechanism by which long-term arsenic stresses play a role in development of hypertension.

Development of the Caliper System for a Geometry PIG Based on Magnetic Field Analysis

  • Kim, Dong-Kyu;Cho, Sung-Ho;Park, Seoung-Soo;Yoo, Hui-Ryong;Park, Yong-Woo;Kho, Young-Tai;Park, Gwan-Soo;Park, Sang-Ho
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.12
    • /
    • pp.1835-1843
    • /
    • 2003
  • This paper introduces the development of the caliper system for a geometry PIG (Pipeline Inspection Gauge). The objective of the caliper system is to detect and measure dents, wrinkles, and ovalities affect the pipe structural integrity. The developed caliper system consists of a finger arm, an anisotropic permanent magnet, a back yoke, pins, pinholes and a linear hall effect sensor. The angle displacement of the finger arm is measured by the change of the magnetic field in sensing module. Therefore the sensitivity of the caliper system mainly depends on the magnitude of the magnetic field inside the sensing module. In this research, the ring shaped anisotropic permanent magnet and linear hall effect sensors were used to produce and measure the magnetic field. The structure of the permanent magnet, the back yoke and pinhole positions were optimized that the magnitude of the magnetic field range between a high of 0.1020 Tesla and a low of zero by using three dimensional nonlinear finite element methods. A simulator was fabricated to prove the effectiveness of the developed caliper system and the computational scheme using the finite element method. The experimental results show that the developed caliper system is quite efficient for the geometry PIG with good performance.

A Study on the Determination of Ionic and Molecular Weight of Dissolved Substance by Dialysis Method (Ⅰ). Improvements of the Dialysis Apparatus and Its Operations (透膜法에 依한 이온量 및 分子量의 決定에 關한 硏究 (I) 透析裝置 및 實驗方法의 改良)

  • Shin Yun Kyong;Rhee Jhun
    • Journal of the Korean Chemical Society
    • /
    • v.16 no.5
    • /
    • pp.304-313
    • /
    • 1972
  • This paper reports the improvements of the dialysis apparatus and operations since there are some problems to be improved in the dialysis method which is applied to determine the ionic and molecular weight of dissolved particles. The hook gauge was utilized in order to control the surface level of the dialysing solution and the solvent to be equal with the precision of 0.02 mm to minimize the osmotic and filtration effects. An accurate agitation velocity for both solutions was maintained and so was the same temperature for both solutions with ${\pm}0.01^{\circ}C$ precision. The dialysis membrane was fixed uniformly and flatly on one end of the dialysis cylinder by using a newly developed ring. The volume change of the dialysing solution during the dialysis was reduced to the range of -1.62 ~ +0.92%. Optimum duration of dialysis was searched from the relation between the osmotic and filtration effect and the pore size of the membrane.

  • PDF

Classification of Adult Women's Fingernail Type (성인 여성의 손톱 유형 분류)

  • Kim, Ha Eun;Kim, Nam Soon;Do, Wol Hee
    • Fashion & Textile Research Journal
    • /
    • v.22 no.4
    • /
    • pp.504-514
    • /
    • 2020
  • This study improves the dimensional suitability of nail tip products by reviewing the type of fingernail as seen among adult women in Korea. Subjects were 147 adult women ranging from age 20 to 40. Direct fingernails measurements were made using digital Vernier calipers and a curvature gauge. Data on various fingernail shapes were collected through indirect measurements using photography to reveal the shape characteristics of each fingernail types. In this sense, data were analyzed by statistical methods with the use of factor analysis. There were various factors considered to classify extracted fingernail types such as five factors (for the thumb), four factors (index, middle, and little fingers), and three factors (for the ring finger). The cluster analysis resulted in three types. Type 1 is a 'Square' shape characterized with wide fingernails, low height, flat, and low curvature of the cuticle line. Type 2 is 'U-round' shape characterized with narrow fingernails, high height, convex, and the highest curvature of the cuticle line. Type 3 is a 'Round' shape in which the fingernails are wide, high in height, convex, and characterized with a medium curvature of the cuticle line. The results are useful for companies that develop the free edge shape of fingernails for consumer products. The measured values of fingernail can be applied to the shape and lake setting of the nail tip product, depending on type of fingernail.

Reconstruction of May~June Precipitation (253 Years: A.D. 1746~1998) in East-Coastal Region (Yungdong) of Korea from Tree Rings of Pinus densiflora S. et Z. (소나무 연륜연대기를 이용한 영동지방의 5~6월 강수량 (253년간: A.D. 1746~1998) 복원)

  • 박원규;서정욱
    • The Korean Journal of Quaternary Research
    • /
    • v.14 no.2
    • /
    • pp.87-99
    • /
    • 2000
  • May-June precipitation (253 years : A.D. 1746∼1998) of Yungdong region (coastal area of East-central Korea) was reconstructed using two tree-ring chronologies of Pinus densiflora sampled from Daeseung Fall area in Sorak Mountains. Dry periods were 1765∼1800 (longest dry period), 1835∼1845, 1890∼1910, 1920∼1940 and 1980∼1995, and wet ones 1810∼1830, 1850∼1890 and 1950∼1970. In long-term variation, late 18th century was dry. The 19th century May-June (250㎜) was wetter than the 20th century (231㎜) and the former indicated higher variability than the latter. Major wet/dry periodicities in May-June precipitation series reconstructed were 3 years in short term and 60∼80 years in long term. The present reconstructed data agreed to the ancient rain gauge 'Chukwooki' data (1777∼1907) of Seoul (central-west Korea) in low frequency variations except early 1800s.

  • PDF

Effective Volume of the Korea Research Institute of Standards and Science Free Air Chamber L1 for Low-Energy X-Ray Measurement

  • Chul-Young Yi;Yun Ho Kim;Don Yeong Jeong
    • Progress in Medical Physics
    • /
    • v.33 no.1
    • /
    • pp.1-9
    • /
    • 2022
  • Purpose: To evaluate the effective volume of the Korea Research Institute of Standards and Science free air chamber (KRISS FAC) L1 used for the primary standard device of the low-energy X-ray air kerma. Methods: The mechanical dimensions were measured using a 3-dimensional coordinate measuring machine (3-d CMM, Model UMM 500, Carl Zeiss). The diameter of the diaphragm was measured by a ring gauge calibrator (Model KRISS-DM1, KRISS). The elongation of the collector length due to electric field distortion was determined from the capacitance measurement of the KRISS FAC considering the result of the finite element method (FEM) analysis using the code QuickField v6.4. Results: The measured length of the collector was 15.8003±0.0014 mm with a 68% confidence level (k=1). The aperture diameter of the diaphragm was 10.0021±0.0002 mm (k=1). The mechanical measurement volume of the KRISS FAC L1 was 1.2415±0.0006 cm3 (k=1). The elongated length of the collector due to the electric field distortion was 0.170±0.021 mm. Considering the elongated length, the effective measurement volume of the KRISS FAC L1 was 1.2548±0.0019 cm3(k=1). Conclusions: The effective volume of the KRISS FAC L1 was determined from the mechanically measured value by adding the elongated volume due to the electric field distortion in the FAC. The effective volume will replace the existing mechanically determined volume in establishing and maintaining the primary standard of the low-energy X-ray.

Strains of abutment and bones on implant overdentures (임플란트 피개의치에서 지대주와 골의 변형률에 관한 연구)

  • Kim, Myung-Seok;Heo, Seong-Joo;Koak, Jai-Young;Kim, Sung-Kyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.2
    • /
    • pp.222-231
    • /
    • 2009
  • Statements of the problem: Over the past decades, conventional complete dentures were used for various patients although they have incomplete function. Overdentures using dental implants could help the improvement of denture function. Purpose: The purpose of this study was to compare the strains of abutment and bone on implant overdenture between splinted and unsplinted type of prosthesis. Additionally, the strain values of parallel placed implant model and unparallel placed implant model were compared. Material and methods: Two acrylic resin model were prepared and two implants were placed at the canine positions in each model. In the first model, two implant were placed parallel. In the second model, two implants were placed with 10 degree labiolingual divergence. Two types of abutment were connected to the fixtures alternatively. One was splint type of Hader bar, the other was unsplint type of ball abutment. Overdentures were fabricated with corresponding attachment systems and seated on abutments. Strains of abutments and labial bone simulants were measured with electric resistance strain gauges when static load from 100 N to 200 N were applied to overdentures. Results: 1. Splinted type of overdentures using bar and clip showed higher absolute strain values. But the strain was compressive and the load was shared by two implants(P<.05). 2. Unsplinted type overdentures using ball and O-ring showed low absolute strain values(P<.05). 3. Labially inclined implant showed higher tensile strain values in unsplinted type of prosthesis than in splinted type of prosthesis. Lingually inclined implant showed rather low strain values under load(P<.05). 4. Non parallel implant model showed higher absolute strain values than parallel placed implant model comprehensively(P<.05).