평판 디텍터 기반 마이크로 CT시스템을 위한 Ring Artifact 보정 방법 (A Ring Artifact Correction Method for a Flat-panel Detector Based Micro-CT System)

  • 김규원;이수열;조민형
    • 대한의용생체공학회:의공학회지
    • /
    • 제30권6호
    • /
    • pp.476-481
    • /
    • 2009
  • The most troublesome artifacts in micro computed tomography (micro-CT) are ring artifacts. The ring artifacts are caused by non-uniform sensitivity and defective pixels of the x-ray detector. These ring artifacts seriously degrade the quality of CT images. In flat-panel detector based micro-CT systems, the ring artifacts are hardly removed by conventional correction methods of digital radiography, because very small difference of detector pixel signals may make severe ring artifacts. This paper presents a novel method to remove ring artifacts in flat-panel detector based micro-CT systems. First, the bad lines of a sinogram which are caused by defective pixels of the detector are identified, and then, they are corrected using a cubic spline interpolation technique. Finally, a ring artifacts free image is reconstructed from the corrected projections. We applied the method to various kinds of objects and found that the image qualities were much improved.

잡음이 있는 X선 프로젝션에 적합한 웨이블렛 기반 영상재구성 (Wavelet based Image Reconstruction specific to Noisy X-ray Projections)

  • 이남용;문종익
    • 융합신호처리학회논문지
    • /
    • 제7권4호
    • /
    • pp.169-177
    • /
    • 2006
  • 이 논문의 목적은 X선의 감쇠를 이용한 측정에서 발생하는 여러 종류의 잡음을 효과적으로 제거하는데 적합한 영상재구성 방법을 제안하는 것이다. 구체적으로, X선의 방출기와 검출기의 필연적인 기계적 오류에 의해 발생하는 원형모양 오류와 전반적인 관측오차와 푸리에 변환기반 재구성 과정에서 나타나는 줄무늬 모양 잡음을 효과적으로 제거하기 위해 웨이블렛 방법을 제안한다. 원형모양 오류를 프로젝션에서 제거하기 위해 해당 잡음이 각도방향으로 강한 상관관계를 가지고 있음을 이용하여, 평균화된 정보에서 해당 잡음의 강도를 추정하고 이를 웨이블렛 축소법을 통해 제거하는 방법을 제안한다. 또한, 전반적인 잡음 제거와 영상재구성을 위해 웨이블렛-배규렛 분해법을 제안한다. 제안된 방법은 기존의 푸리에 변환을 기반으로 하는 방법에 비해 원형모양 오류와 영상재구성에 있어서 우수한 영상을 제공함을 시뮬레이션을 통해 확인하였다.

  • PDF

X-ray micro-CT 이미지 내 패임 및 동심원상 화상결함 제거를 위한 이미지 보정 기법 (Image Calibration Techniques for Removing Cupping and Ring Artifacts in X-ray Micro-CT Images)

  • 정연종;윤태섭;김광염;주진현
    • 한국지반공학회논문집
    • /
    • 제27권11호
    • /
    • pp.93-101
    • /
    • 2011
  • X-ray micro-CT를 이용한 지반재료 내부 미세구조 및 공극구조의 정밀한 이미지 처리는 종종 이미지 내에 원천적으로 포함되는 화상결함으로 인해 제약된다. 본 논문에서는 X-ray micro-CT 이미지에 가장 일반적으로 나타나는 화상결함인 패임(영상 외곽과 중심부의 명암 차이) 및 동심원상(영상 중심으로부터 방사방향으로 연속적으로 나타나는 원)을 제거할 수 있는 이미지 보정 기법을 제시한다. 결함 제거는 좌표 변환법, 정규화 및 2차원 푸리에 변환에 의한 저역 통과 필터링 기법의 순차적 적용을 통해 이루어진다. 이미지 처리 기법의 효과를 다공성 현무암의 CT 이미지에서 화상결함들을 제거하고 이진화 후 적층하여 3차원 공극 구조를 추출하는 과정을 통해 설명하였다. 패임 및 동심원상 결함을 제거한 이미지와 원본 이미지의 비교 결과 결함 제거는 대상 재료 공극률의 과대평가를 방지할 수 있으며, 따라서 화상결함의 적절한 보정은 X-ray CT의 지반재료 적용 시 필수적인 과정으로 판단된다.

대수적 재구성 기법을 통한 링 아티팩트 조사 (Investigation of Ring Artifact Using Algebraic Reconstruction Technique)

  • 천권수
    • 한국방사선학회논문지
    • /
    • 제12권1호
    • /
    • pp.65-70
    • /
    • 2018
  • CT 장치는 물체 내부의 단면 영상 획득이 가능하기 때문에 여러 분야에 광범위하게 사용되고 있다. 단면 영상을 획득하는 여러 단계의 에러 요인들로 인해 다양한 아티팩트가 유발되고 있다. 장치에 의해 발생하는 링 아티팩트를 조사하였다. $512{\times}512$ 크기의 수치 팬텀을 구현하고 대수적 재구성 기법으로 링 아티팩트의 특성을 연구하였다. 프로그램은 Visual C++로 작성하였으며 720개의 투영 및 1,280개의 검출기 픽셀을 갖는 상황에서 구현하였다. 링 아티팩트는 검출기 픽셀의 검출 효율이 서로 달라서 발생한다는 것을 확인하였다. Ring Value 값이 증가할수록 Ring Intensity의 값도 증가하였고, 영상의 원점에 가까울수록 링 아티팩트가 강하게 나타났다. 단면 영상에서 링 아티팩트가 발생하는 위치를 파악하고 역으로 검출기 픽셀의 위치를 추적해 검출효율을 보정함으로써 링 아티팩트를 제거할 수 있을 것이다.

Reconstruction of In-beam PET for Carbon therapy with prior-knowledge of carbon beam-track

  • Kim, Kwangdon;Bae, Seungbin;Lee, Kisung;Chung, Yonghyun;An, Sujung;Joung, Jinhun
    • IEIE Transactions on Smart Processing and Computing
    • /
    • 제4권6호
    • /
    • pp.384-390
    • /
    • 2015
  • There are two main artifacts in reconstructed images from in-beam positron emission tomography (PET). Unlike generic PET, in-beam PET uses the annihilation photons that occur during heavy ion therapy. Therefore, the geometry of in-beam PET is not a full ring, but a partial ring that has one or two openings around the rings in order for the hadrons to arrive at the tumor without prevention of detector blocks. This causes truncation in the projection data due to an absence of detector modules in the openings. The other is a ring artifact caused by the gaps between detector modules also found in generic PET. To sum up, in-beam PET has two kinds of gap: openings for hadrons, and gaps between the modules. We acquired three types of simulation results from a PET system: full-ring, C-ring and dual head. In this study, we aim to compensate for the artifacts that come from the two types of gap. In the case of truncation, we propose a method that uses prior knowledge of the location where annihilations occur, and we applied the discrete-cosine transform (DCT) gap-filling method proposed by Tuna et al. for inter-detector gap.

강릉시 초당동 고분 출토 금속유물 보존 (Conservation of metal artifacts excavated from tumulus in Chodang-dong, Kangreung City)

  • 유재은
    • 보존과학연구
    • /
    • 통권21호
    • /
    • pp.77-99
    • /
    • 2000
  • Tumuli located in Chodang-dong in Kangreung City are sitesexcavated by the Museum of Kangreung University in 1993.Ofthese sites, a gilt bronze crown and gilt bronze sword with ring pommel with a tri-leaf ornament were excavated from the B-16tumulus. Underneath the gilt bronze crown was the gilt bronzes word with ring pommel with tri-leaf ornament, and these artifacts were treated with Polyurethane foams on the spot followed by special measures for conservation. This manuscript describes measures for conservation andanalysis with regard to the gilt bronze crown, gilt bronze sword with ring pommel with tri-leaf ornament and gilt bronze beltornaments. Bronze on the gilt bronze crown was completely corroded, therefore it was consolidated together with soil in the back of the artifact with Paraloid B72 after cleaning. Polyurethanefoams bottom was finished by applying the mixture of Epoxy resinAW106 and HV935K with soil. On the sword with ring pommel, the wooden part of the hilt was coated with Paraloid B72 (in Xylene) and the blade was consolidated with Paraloid NAD-10 30% after desalting with Sodium sesquicarbonate method. The gilt bronzebelt ornaments were treated with 3% Benzotriazole, coated with Paraloid B72 and then joined by using Cyanlacrylate. Specimens for the gilt bronze crown and gilt bronze belt ornaments were produced and gilding layers were examined under a metallographic microscope. The gilt bronze crown and the gilt bronze belt ornament maintained relatively good gilding quality with uniform gilding layers. Analysis of wood for the sheath of the sword with ring pommel revealed it to be Juglans mandshurica. Further more, analysis of constituents for a blue colored grassbead from dissolution of Polyurethane foams found it to be from the $Na_2O$-CaO-$AI_2O_3$-$SiO_2$ family.

  • PDF

Wiggle Matching for Radiocarbon Dating Korean Artifacts with Biannual Samples

  • Park, Won-Kyu;Nam, Tae-Kwang;Park, Jung-Hun;Hong, Wan
    • 한국가구학회지
    • /
    • 제20권6호
    • /
    • pp.605-611
    • /
    • 2009
  • This paper reports the application of radiocarbon wiggle matching for Korean wooden artifacts such as furniture and Buddhist statues for precise dating. Ten biannual samples of 20 years (AD 1249-1268) for AMS (accelerator mass spectrometry) radiocarbon measurements were prepared from a board of the pedestal for Buddhist statue at Jeongsusa (temple) in Kangwhado, Korea, which was dendrochronologically dated. The average 95.4% confidence interval of radiocarbon dating without wiggle matching was 123 year. When wiggle matching technique was applied, it became 37 year, 3.3 times smaller than that without wiggle matching. The results indicated that wiggle matching technique using the calibration curve for northern hemisphere (IntCal04: International radiocarbon calibration curve announced in 2004) can produce precise dates for Korean wooden artifacts which possess as much as 20 tree rings.

  • PDF

분해능 향상을 위한 새로운 양전자 단층 촬영기의 제안 (Resolution Improvement of the Positron Computerized Tomography with a New Positron Camera Tomographic System)

  • 홍기상;나종범
    • 대한전자공학회논문지
    • /
    • 제16권6호
    • /
    • pp.22-30
    • /
    • 1979
  • 새로운 구조의 양전자 전산 단층 촬영기(Positron Computerized Tomography)를 제안하고 그 시스템의 성능을 컴퓨터로 예측하였다. 이 새로운 구조의 시스템은 sampling 간격을 임의로 할 수 있기 때문에 기존의 시스템에 비해서 보다 높은 분해능의 단층 영상을 얻을 수 있다. 컴퓨터 시뮬레이션으로 이 시스템에 어떠한 artifact가 생기나 살펴 보았고 Poisson noiserk 더해졌을 때의 영상을 비교함으로써 이 시스템이 기존의 시스템보다 나은 영상을 얻을 수 있음을 확인하였다.

  • PDF

고대 건축의 지붕부에 사용된 금속장식에 관한 연구 (A Study on the Ornamental Metal Used in the Roof of Ancient Architecture in Korea)

  • 윤일이
    • 대한건축학회논문집:계획계
    • /
    • 제36권2호
    • /
    • pp.63-70
    • /
    • 2020
  • In the ancient Buddhist temple area, various metal artifacts are still excavated. Therefore, the aim of this study is to approach the characteristics of ancient architecture through ancient metal artifacts. First, metal decoration of ancient architecture appears for the purpose of structure, decoration, arson. Then, as the method of wood structure is developed, the application is separated into structural, functional and decorative purposes. In ancient times, metal decoration has reduced the role of structure, but its decorative role has expanded. Second, various metallic ornaments were used on the roof of ancient architecture. As the wooden technology developed, the metal decoration was gradually omitted while applying the curve to the roof. Third, the metal ornaments used on the roof of ancient architectures include the ridge central decoration, roof top decoration, a nine-ring decoration, gable board Ornamental Metal, corner flower decoration, eaves nail, wind bell. And subsequent research requires a terminology that can link the results of archeology and Buddhist art through excavation as a result of architecture.

철제 환두부 보존처리 과정의 3차원 디지털기록 및 형상변화 분석 (Three-dimensional digital recording of the conservation treatment and form analysis of an iron ring pommel)

  • 최효령;홍성혁;조영훈;조남철
    • 박물관보존과학
    • /
    • 제25권
    • /
    • pp.85-94
    • /
    • 2021
  • 부식생성물, 이물질 등이 고착된 금속유물의 보존처리는 처리 전·후 형태와 특성, 유물의 중량 및 두께가 변한다. 지금까지 보존처리 전·후 변화에 대한 기록은 주로 육안관찰, 사진촬영 등을 통해 수행되었으나, 이 방법들은 보존처리 변화에 대한 정량적 결과를 파악하는 데 어려움이 있다. 본 연구에서는 환두부를 중심으로 이물질 제거, 균열부 메움, 복원 등의 과정을 3차원 스캐닝으로 기록하여 보존처리에 따른 형상 변화를 정량적으로 분석하였다. 3차원 스캐닝 결과를 기반으로 보존처리에 따른 부피 변화를 산출하고 형상 변화에 대한 수치자료를 분석하였다. 이 결과, 전체적으로 이물질 및 부식물은 보존처리 전 부피의 약 52%(18.1cm3)가 줄어들었고, 표면적으로 볼 때 약 98%가 제거된 것으로 확인되었다. 이 연구는 3차원 형상분석 기술이 유물의 보존처리 기록화 및 분석에 유용함을 보여주었다. 따라서 이 방법론은 금속유물뿐만 아니라 다양한 재질의 문화유산에 확대적용이 가능할 것으로 판단된다.