• Title/Summary/Keyword: Right to Die

Search Result 65, Processing Time 0.024 seconds

Evaluating the accuracy (trueness and precision) of interim crowns manufactured using digital light processing according to post-curing time: An in vitro study

  • Lee, Beom-Il;You, Seung-Gyu;You, Seung-Min;Kim, Dong-Yeon;Kim, Ji-Hwan
    • The Journal of Advanced Prosthodontics
    • /
    • v.13 no.2
    • /
    • pp.89-99
    • /
    • 2021
  • PURPOSE. This study aimed to compare the accuracy (trueness and precision) of interim crowns fabricated using DLP (digital light processing) according to post-curing time. MATERIALS AND METHODS. A virtual stone study die of the upper right first molar was created using a dental laboratory scanner. After designing interim crowns on the virtual study die and saving them as Standard Triangulated Language files, 30 interim crowns were fabricated using a DLP-type 3D printer. Additively manufactured interim crowns were post-cured using three different time conditions-10-minute post-curing interim crown (10-MPCI), 20-minute post-curing interim crown (20-MPCI), and 30-minute post-curing interim crown (30-MPCI) (n = 10 per group). The scan data of the external and intaglio surfaces were overlapped with reference crown data, and trueness was measured using the best-fit alignment method. In the external and intaglio surface groups (n = 45 per group), precision was measured using a combination formula exclusive to scan data (10C2). Significant differences in accuracy (trueness and precision) data were analyzed using the Kruskal-Wallis H test, and post hoc analysis was performed using the Mann-Whitney U test with Bonferroni correction (α=.05). RESULTS. In the 10-MPCI, 20-MPCI, and 30-MPCI groups, there was a statistically significant difference in the accuracy of the external and intaglio surfaces (P<.05). On the external and intaglio surfaces, the root mean square (RMS) values of trueness and precision were the lowest in the 10-MPCI group. CONCLUSION. Interim crowns with 10-minute post-curing showed high accuracy.

Comparison of accuracy of digital data obtained by intra-oral scanner and extra-oral scanner (구강 내 스캐너와 구강 외 스캐너를 사용하여 취득된 스캔 데이터 정확도 비교)

  • Lee, Jae-Jun;Jeong, Il-Do;Kim, Chong-Myung;Park, Jin-Young;Kim, Ji-Hwan;Kim, Woong-Chul
    • Journal of Technologic Dentistry
    • /
    • v.37 no.4
    • /
    • pp.191-197
    • /
    • 2015
  • Purpose: The purpose of this study was to compare the accuracy of the scan data acquired by the extra-oral and intra-oral scanner. Methods: The maxillary right first molar was made of polymethyl methacrylate(PMMA) specimen. This PMMA specimen was scanned with a engineering scanner and intra-oral scanner. Meanwhile, extra-oral scanner scanned stone die duplicated from PMMA master die. Trueness and precision of scan datas was measured by 3-dimensinal inspection. Independent t-test was conduct to analysis the significant difference(a=0.05). Results: In the trueness analysis, mean of discrepancies were 13.82um for intra oral scanner and 16.84 um for extra-oral scanner. In the precision analysis, mean of discrepancies were 11.72 for inta-oral scanner and 9.2 for extra-oral scanner. Both trueness and precision showed a statistically significant difference (Table 1, p<0.05). Conclusion: Intra-oral scanner can show higher trueness than extra-oral scanner, it has lower precision.

Accuracy of dies fabricated by various three dimensional printing systems: a comparative study (다양한 삼차원 프린팅 시스템으로 제작된 다이의 정확도 비교)

  • Baek, Ju Won;Shin, Soo-Yeon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.36 no.4
    • /
    • pp.242-253
    • /
    • 2020
  • Purpose: The aim of this study was to compare the accuracy of dies fabricated using 3D printing system to conventional method and to evaluate overall volumetric changes by arranging the superimposed surfaces. Materials and Methods: A mandibular right first molar from a dental model was prepared, scanned and fabricated with composites of polyetherketoneketone (PEKK). Master dies were classified into 4 groups. For the conventional method, the impression was taken with polyvinylsiloxane and the impression was poured with Type IV dental stone. For the 3D printing, the standard die was scanned and converted into models using three different 3D printers. Each of four methods was used to make 10 specimens. Scanned files were superimposed with the standard die by using 3D surface matching software. For statistical analysis, Kruskal-Wallis test and Mann-Whitney U test were done (P < 0.05). Results: Compared to the standard model, the volumetric changes of dies fabricated by each method were significantly different except the models fabricated by conventional method and 3D printer of Stereolithography (P < 0.05). The conventional dies showed the lowest volumetric change than 3D printed dies (P < 0.05). 3D printed dies fabricated by Stereolithography showed the lowest volumetric change among the different 3D printers (P < 0.05). Conclusion: The conventional dies were more accurate than 3D printed dies, though 3D printed dies were within clinically acceptable range. Thus, 3D printed dies can be used for fabricating restorations.

THE ACCURACY ACCORDING TO THE VARIOUS DOWEL PINS OF WORKING CAST WITH REMOVABLE DIES (가철성 다이를 가진 작업모형에서 다우엘 핀의 종류에 따른 정확도에 관한 연구)

  • Lim, Ju-Hwan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.35 no.2
    • /
    • pp.373-384
    • /
    • 1997
  • In this study, 4 types of dowel pin were used to fabricate removable dies using the Pindex system. The comparison of interabutment distances between before and after sawing were conducted in each type of dowel pin, and the horizontal discrepancies in the interabutment distance according to the abutment location and the type of dowel pin were comparatively analyzed. Abutments LM(left molar), LP(left premolar), A(anterior), RP(right premolar), and RM (right molar) were used for measurement. The interabutment distances were measured between each abutment : LM-LP, LM-A, LM-RP, and LM-RM. The slide scanned image of each model was magnified on the computer screen and the measurements were conducted using the meeting point of the cross on the occlusal surface of each abutment. The results were as follows : 1. In the comparison of interabutment distances between before and after sawing in each type of dowel pin, there was no significant difference in World dowel pin(double), Bi-pin(double), Maxcel dowel pin(single). In the World dowel pin(single) there was no significant difference between LM-LPs, but in the other measurements (LM-As, LM-RPs, and LM-RMs) there was significant difference between before and after sawing(p<0.05). 2. In comparison of horizontal discrepancies of the measurement according to the abutment location, there was significant difference between measurement LM-LP($0.27{\pm}0.19mm$) and the others : LM-A($0.46{\pm}0.20mm$), LM-RP($0.38{\pm}0.25mm$), LM-RM($0.45{\pm}0.22mm$) (p<0.05). 3. In comparison of horizontal discrepancies of the measurement according to the type of dowel, there was no significant difference between each dowel. As a result when fabricating a removable die using the previously mentioned 4 types of dowel pins, it is thought that the horizontal discrepancy increased in proportion to the interabutment span length and does not depend on the type of dowel pin.

  • PDF

Factors That Influence Attitudes toward Advance Directives among Female Cancer Patients

  • Aeri Kim;Kisook Kim
    • Journal of Hospice and Palliative Care
    • /
    • v.26 no.2
    • /
    • pp.80-94
    • /
    • 2023
  • Purpose: This study aimed to identify attitudes toward advance directives (ADs) among female cancer patients and factors related to ADs. Methods: The study was conducted at a university hospital in Seoul from September 19, 2020, to January 20, 2021. The participants were 153 patients diagnosed with gynecological cancer or breast cancer. Data were collected using questionnaires and included general characteristics, disease- and AD-related characteristics, knowledge and attitudes about ADs, and attitudes about dignified death. Data were analyzed using the t-test, analysis of variance, and multiple regression analysis. Results: Only 2% of the participants completed ADs. The mean score for attitudes toward ADs was 3.30, indicating a positive knowledge and attitude toward dignified death. The factors related to attitudes toward ADs were attitudes toward dignified death (𝛽=0.25, P=0.001), experience discussing life-sustaining treatment (𝛽=0.17, P=0.037), preferred time to have a consultation about ADs (𝛽=0.19, P=0.046), intention to write ADs (𝛽=0.15, P=0.038), and Eastern Cooperative Oncology Group Performance Status (𝛽=-0.37, P<0.001). The explanatory power of these variables for attitudes toward ADs was 38.5%. Conclusion: Overall, patients preferred to have a consultation about ADs when they were still active, mentally healthy, and able to make decisions. Education about ADs should be provided to patients on the first day of hospitalization for chemotherapy or while awaiting treatment in an outpatient setting so patients can write ADs and discuss them with family and friends.

Surgical Treatment of Atrial Septal Defect in Adult - Clinical Review of 31 Cases - (성인의 선천성 심방중격결손증의 외과적 치료)

  • 장운하;오태윤;배상일
    • Journal of Chest Surgery
    • /
    • v.31 no.8
    • /
    • pp.770-775
    • /
    • 1998
  • Background: Atrial septal defect (ASD) is the most common congenital cardiac anomaly, accounting for 30 percent of congenital heart disease detected in the adult. Many patients with ASD are well tolerated and reach adult without significant symptoms. The patients with ASD die 4th and 5th decades, but prolonged survival is not uncommon. In general, the survival depends on whether pulmonary hypertension develops during adulthood or not. The most common cause of death in the patients with ASD is right ventricular failure or arrhythmias. Materials and methods: From January 1988 to June 1997, 33 cases of ASD underwent open heart surgeries in our hospital. Among them, 31 cases were adult ASD, and 2 tricuspid regurgitation, 1 pulmonic stenosis, 1 mitral regurgitation, 1 tricuspid regurgitation, and 1 coronary artery disease were combinded. All of the patients underwent surgical repair using autologus pericardial patch or direct closure. Results: The postoperative course was smooth and uneventful. Most of the patients showed significant improvement in ECG finding, hemodynamic profile, radiologic finding, and echocardiography, after surgery. Conclusions: Conclusively, most of the ASD should be closed even in patients over the age of 60 years, and early surgical repair must be done to prevent pulmonary hypertension, right ventricular failure, and arrythmias.

  • PDF

The awareness of medical department students about euthanasia (안락사에 대한 의료계열 학생들의 인식도)

  • Lee, Hyun-Ju;Kim, Jung Sun;Kim, Hoon;Kim, Chul-Tae
    • The Korean Journal of Emergency Medical Services
    • /
    • v.23 no.1
    • /
    • pp.165-178
    • /
    • 2019
  • Purpose: This study examined medical college students' perception of euthanasia and analyzed whether there were significant differences in their perceptions based on their grade, religion, and economic situation. Methods: A questionnaire comprising items relating to students' knowledge about euthanasia, their economic situation relationships with patients, and the extent to which euthanasia would be allowed depending on the patient's condition. Results: Results by age and school year revealed there were no statistically significant differences concerning permissible levels of euthanasia. However, differences were found in the permissible levels of euthanasia according to changes in the patients' condition. Conclusion: It can be interpreted that students' personal values and religion had a great effect on the perception of euthanasia than the process of acquiring medical knowledge. The religion or values they have in your life affect your perception of euthanasia more than the process of acquiring and learning medical knowledge. The suffering of patients is the most important priority and it supports euthanasia on the grounds of relieving psychological distress for patients' families and the right of every patient to die gracefully. Nevertheless, considering the possibility of patient survival and euthanasia being used for murder, it is necessary to legislate the use of euthanasia and have the appropriate qualifications for its administration on patients.

Concept Analysis of Well-dying in Korean Society (한국사회의 웰다잉 개념분석)

  • Kim, Gahye;Park, Yeon-Hwan
    • Journal of muscle and joint health
    • /
    • v.27 no.3
    • /
    • pp.229-237
    • /
    • 2020
  • Purpose: This paper aims to clarify the concept of well-dying in the sociocultural context of Korea. Methods: Walker and Avant's method was chosen for the concept analysis. Through a literature review of 36 papers, the attributes and definition of well-dying were derived. Results: The literature revealed that in Korean society, well-dying is defined as the process of actively preparing for death throughout life. The attributes of the concept are a reflection on death, death acceptance, searching for meaning, transcendence, advance decision-making, and sharing values with family. The motivation for thinking about death, the hope of dying with dignity, and the Korean cultural view of death precede the concept, followed by dying with dignity, personal and family happiness, and improved quality of life and death. Conclusion: This study may lead to the unification of concept use based on mutual understanding, thus enabling effective communication in research, education, and clinical settings. This can be the rationale for the development of tools and educational programs as well as establishing policies related to well-dying in Korea.

Investigation of the Distance from One Tooth Center to Adjacent Tooth Center and Dental Arch Size to Develope New Removable Die System for Fabrication of Dental Prosthetic Appliance (치과보철물 제조용 모형 조립체(가철식 치형 시스템) 개발을 위한 인접 치아 중심 간격 및 악궁 크기 조사)

  • Kim, Bu-Sob;Ma, Seung-Ho;Jeong, Kyung-Mok;Byun, Tae-Hee
    • Journal of Technologic Dentistry
    • /
    • v.29 no.2
    • /
    • pp.151-161
    • /
    • 2007
  • To obtain the information of dental arch size and the distance from one tooth center to adjacent tooth center of occlusal surface of each tooth which is perforated by Pindex system on working cast for removable die system, 600 dental casts in Busan were examined. The distance of center of occlusal surface of each tooth and dental arch size were digitized. The results were as follows; 1. Mean values of the distance from center of maxillary central incisor to maxillary lateral incisor(tooth number 11$\sim$12, 21$\sim$22) is 5,7 mm, 12$\sim$13(22$\sim$23) is 5.9 mm, 13$\sim$14(23$\sim$24) is 6.9 mm, 14$\sim$15(24$\sim$25) is 7.1 mm, 15$\sim$16(25$\sim$26) is 8.4 mm, 16$\sim$17(26$\sim$27) is 10.2 mm, 11$\sim$21 is 7.30 mm. Mean values of the distance from center of mandibular central incisor to mandibular lateral incisor(tooth number 31$\sim$32, 41$\sim$42) is 4.5 mm, 32$\sim$33(42$\sim$43) is 4.8 mm, 33$\sim$34(43$\sim$44) is 6.3 mm, 34$\sim$35(44$\sim$45) is 7.2 mm, 35$\sim$36(45$\sim$46) is 9.2 mm, 36$\sim$37(46$\sim$47) is 10.7 mm, 31$\sim$41 is 4.7 mm. 2. Mean values of the distance from the center of maxillary right central incisor to the center of maxillary left central incisor(11$\sim$21) is 7.3 mm, 12$\sim$22 is 18.2 mm, 13$\sim$23 is 26.9 mm, 14$\sim$24 is 37.2 mm, 15$\sim$25 is 43.2 mm, 16$\sim$26 is 48.5 mm, 17$\sim$27 is 53.5 mm. Mean values of the distance from the center of mandibular right central incisor to the center of mandibular left central incisor(31$\sim$41) is 4.7 mm, 32$\sim$42 is 13.3 mm, 33$\sim$43 is 21.7 mm, 34$\sim$44 is 31.9 mm, 35$\sim$45 is 38.2 mm, 36$\sim$46 is 44.8 mm, 37$\sim$47 is 50.7 mm. 3. Mean values of the distance from the line of between 11$\sim$21 to 12$\sim$22 is 10.9 mm, 12$\sim$22 to 13$\sim$23 is 8.7 mm, 13$\sim$23 to 14$\sim$24 is 10.3 mm, 14$\sim$24 to 15$\sim$25 is 6.0 mm, 15$\sim$25 to 16$\sim$26 is 5.3 mm, 16$\sim$26 to 17$\sim$27 is 5.0 mm. 31$\sim$41 to 32$\sim$42 is 8.6 mm, 32$\sim$42 to 33$\sim$43 is 8.4 mm, 33$\sim$43 to 34$\sim$44 is 10.2 mm, 34$\sim$44 to 35$\sim$45 is 6.3 mm, 35$\sim$45 to 36$\sim$46 is 6.6 mm, 36$\sim$46 to 37$\sim$47 is 5.9 mm. 4. We checked the bottom side of cast to verify the position of dowel pin. There is no difference upper side and lower side.

  • PDF

Concept Analysis of DNR(Do-Not-Resuscitate) (소생거부(Do-Not-Resuscitate: DNR)의 개념분석)

  • Park, Hyoung-Sook;Koo, Mi-Jee;Kim, Young-Hee
    • Journal of Korean Academy of Nursing
    • /
    • v.36 no.6
    • /
    • pp.1055-1064
    • /
    • 2006
  • Purpose: The purpose of this study was to analyze and clarify the ambiguous concept of DNR, and to distinguish between DNR and euthanasia. Method: This study used the process of Walker & Avant's concept analysis. Result: The definable attributes of DNR were care for comfort, no further treatment and no CPR. The antecedents of DNR were the autonomy of patients and families feelings about death, the uselessness of treatment and the right to die with dignity. The process of the DNR decision should be documented and the antecedents of DNR also can be a basis for objective standards of DNR decision-making. The result of DNR was the acceptance of death by patients and families. Conclusion: DNR is decided and documented by the antecedents of DNR, and the result is a natural acceptance of death, the last process of human life. Hospice care should be activated and nurses must be patient's advocates and families' supporters in the process.