• 제목/요약/키워드: Right angle

검색결과 1,019건 처리시간 0.034초

Life-threatening nasotracheal tube obstruction by a blood clot: a case report

  • Dajeong Lee;Chan Yong Park;Sang Wha Kim
    • Journal of Trauma and Injury
    • /
    • 제37권3호
    • /
    • pp.220-223
    • /
    • 2024
  • The nasotracheal tube (NTT) is frequently used in oral and maxillofacial surgery and is generally considered a safe means of protecting the airway while ensuring an adequate surgical field. The most common complication associated with NTT is epistaxis, and only a few cases of foreign body obstruction have been reported. In this case report, the authors aimed to highlight the potential for NTT obstruction following surgery. A 24-year-old female patient, who underwent mandibuloplasty and rhinoplasty at a local clinic, was referred to our hospital patient due to dyspnea and edema on her right mandibular angle. Even with NTT, patient continued to experience mild dyspnea and tachypnea, so a T-piece was applied. However, tachycardia accompanied by a sudden worsening of dyspnea was observed, and bag-valve-mask ventilation was initiated promptly. But oxygen saturation remained unimproved, so an emergency cricothyroidotomy was performed. After 4 hours, the patient's condition stabilized. Upon examination, the previously inserted NTT was identified, and a blood clot approximately 10 cm long at the NTT tip was discovered, causing lumen obstruction. The obstructions of NTT can lead to serious or life-threatening consequences if left unobserved or ignored. Therefore, when a patient with an NTT complains of dyspnea, clinicians should promptly investigate the possibility of partial NTT obstruction to ensure the airway's security.

Ergonomic Design of Necklace Type Wearable Device

  • Lee, Jinsil;Ban, Kimin;Choe, Jaeho;Jung, Eui S.
    • 대한인간공학회지
    • /
    • 제36권4호
    • /
    • pp.281-292
    • /
    • 2017
  • Objective: This study aims to identify important physical design variables in designing a necklace type wearable device, and to present design guidelines to maximize comfort that a user feels upon wearing the device. Background: Interests in fitness culture and personal health are on the rise recently. In such a situation, demand for necklace type wearable devices is projected to increase a lot, as the devices enable users to use their hands freely and to enjoy various contents through connection with mobile devices. However, the necklace type wearable device's comfort was assessed to have the lowest comfort in a running situation, where human body moves up and down and left and right more than other devices wearable on other human body parts. Therefore, the usability of a necklace type wearable device was low. In this regard, studies on identification of the variables affecting user comfort upon wearing a necklace type wearable device and on physical design direction maximizing comfort and usability are needed. Method: A pretest and a main test were carried out to draw the direction of necklace type wearable device design. In the pretest, wearing evaluation on the diverse types of devices released in the market was conducted to draw physical design variables of the devices affecting comfort. Furthermore, variables significantly affecting the comfort of a device were selected through an analysis of variance (ANOVA). In the main test, anthropometry was performed, and information on anthropometric items corresponding to the design variables selected in the pretest was acquired. Based on the pretest results and the anthropometric information in the main test, the present study produced design guidelines maximizing the comfort of a necklace type wearable device with regard to major design variables upon dynamic tasks. Results: According to the pretest results, the variables having effects on comfort were the angle of side points, width, and height. Due to interactions between variables, those need to be simultaneously considered upon designing a device. Upon dynamic tasks, the angle of side points and width of a device was designed to be smaller than mean angle of the trapezius muscle and neck width, and thus attachment to human body was high. As height was designed to be larger than mean neck front and rear point width, comfort was higher due to feeling of stability. Conclusion: Because user sensitivity to comfort was high at human body's inflection points, a device needs to be designed for users not to feel high pressure on specific body parts with the device fitting human body shape well. A design considering user's situation is also required in further studies.

MR 영상에서의 PACS Image Viewer를 이용한 대퇴골 전염각 측정 (MR Imaging Measurement of the Femoral Anteversional Angle as a PACS Image Viewer)

  • 권대철;양성환;박범
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제26권1호
    • /
    • pp.83-89
    • /
    • 2003
  • 대퇴골 전염각의 정확한 측정은 정형외과 분야에서 중요한 의미를 가지며, 원위 대퇴골의 양과부를 횡단하는 면에 대하여 대퇴골 경부의 장축이 전방으로 기울어진 축면상의 각도이다. 대퇴골부와 슬개골부를 전산화단층촬영한 영상을 측정하고 있는 기존의 CT 영상의 대퇴골 측정법을 대신하여 다양한 Pulse sequence를 이용한 자기공명영상으로 PACS Image viewer에서 성인 남자 $28{\sim}36$세를 대상으로 대퇴골 전염각을 측정하였다. 오른쪽 대퇴골 전염각의 T2강조영상은 $18.5{\sim}45.4^{\circ}$, T1강조영상 $18.9{\sim}25.6^{\circ}$, 경사에코 $18.7{\sim}26.0^{\circ}$, 지방억제기법 $21.3{\sim}24.9^{\circ}$, 왼쪽 대퇴골 전염각의 T2강조영상은 $19.2{\sim}24.3^{\circ}$, T1강조영상 $18.8{\sim}24.5^{\circ}$, 경사에코 $20.1{\sim}25.6^{\circ}$, 지방억제기법 $20.0{\sim}25.3^{\circ}$로 측정되었고, 오른쪽과 왼쪽 대퇴골 전염각의 이원배치 분산분석에서 모두 유의한 차이가 있었다(p<0.05). 수 작업 방법의 대퇴골 전염각 측정에 비해 Image Viewer 프로그램에서는 마우스를 이용한 측정으로 편리하였고, MR 영상은 CT 영상에 비해 다양한 Pulse sequence를 선택적으로 적절한 촬영기법을 사용하여 대퇴골 전염각 측정에 유용하였다.

  • PDF

체형에 따른 골프 스윙 동작 비교 (A Comparison of the Difference in the Golf Swing Motion According to Somatotypes)

  • 정남주;윤희중;백영수
    • 한국운동역학회지
    • /
    • 제12권2호
    • /
    • pp.33-49
    • /
    • 2002
  • 본 연구는 골프스윙 시 체형별로 나타나는 운동학적 요인을 분석하여 비교함으로써 체형별 골프지도를 위한 기초자료를 제공하는데 있다. 이를 위해 현재 남자 프로골프선수 9명을 대상으로 각자의 체중과 신장 그리고 상완둘레등을 고려하여 외배엽, 내배엽, 중배엽으로 체형을 나누었다. 각자의 골프스윙동작을 비디오 카메라로 촬영하여 스윙동작을 8개의 구간으로 나누어 분석하였으며 다음과 같이 결론에 도달하였다. 골프스윙 소요시간은 내배엽형이 가장 길었으며 다음으로 중배엽형, 마지막으로 외배엽형이 가장 짧은 스윙시간을 보이고 있었다. 좌우이동변위가 가장 크게 나타나는 체형은 중배엽형이었으며, 다음으로는 내배엽형, 그리고 외배엽형이 가장 작게 움직이는 것으로 나타났다. 내배엽형은 임팩트 시 상하변위가 상승쪽으로 향하고 있었으며 내배엽형과 중배엽형은 임팩트 시 거의 일정한 높이를 유지하여 안정감을 높이는 것으로 나타났다. 상체회전각도와 골반회전각도는 임팩트 시 외배엽형의 상체와 골반이 미리 돌아가는 형태를 취하고 있어 내배엽과 중배엽형에 비해 다소 다른 특징을 보이고 있었다. 이러한 스윙에 대한 체형별 운동학적 특징을 이론을 제시함에 있어 보다 근본적인 힘의 이동을 알아야 할 필요가 있다. 따라서, 차후 연구에서는 지면반력을 이용하여 압력중심점(COP)의 분석이 함께 이루어져야 할 것으로 판단된다.

피로강도 향상을 위한 용접이음부의 형상제어에 관한 연구 (A Shape Control of Welded Joints to Improve Fatigue Strength)

  • 강창입;국승규;이동욱
    • 한국강구조학회 논문집
    • /
    • 제16권4호통권71호
    • /
    • pp.479-492
    • /
    • 2004
  • 본 연구에서는 강상판의 U리브를 현장에서 상향의 용접자세로 용접이음을 실시할 경우, 용접이음부에는 시공오차에 의한 단차가 발생하고, 응력집중이 발생하기 쉽다. 따라서 본 연구에서는 이면재가 부착된 용접이음부에 대해 응력해석 및 실험을 실시하였다. 이면재가 부착된 U리브 용접이음부의 단차, 루트부 형상, 루트갭 및 이면재의 폭과 두께를 변화시켜 응력해석을 실시한 결과, 단차가 커질수록 응력집중계수는 현저히 증가하였으며, 루트갭도 커질수록 응력집중계수가 증가하는 것을 알 수 있었다. 또한 단차 및 루트갭이 동일한 경우에는 루트부 형상이 직각인 경우보다 반원인 경우에 응력집중계수가 작게 나타났으며, 이면재의 폭 및 두께는 응력집중계수에 그다지 영향을 미치지 않는 것으로 나타났다. 이면재가 부착된 시험편의 피로실험에서는 단차가 커질수록 피로수명이 현저히 저하되었으며 피로균열은 이면재가 부착된 모재측 루트부에서 발생하여 용접비드 표면측으로 전파하였다. 응력해석에서 루트부의 형상이 반원인 경우, 응력집중계수가 작게 나타나므로, 용접조건을 변화시켜 루트부 곡률반경 및 플랭크각을 제어하는 루트부 형상제어법를 개발하였다.

토릭렌즈의 표면 곡률 특성 연구 (Properties of a Surface Curvature in Toric Lens)

  • 박상안;김용근
    • 한국안광학회지
    • /
    • 제6권2호
    • /
    • pp.65-70
    • /
    • 2001
  • 두 개의 토로이드 면이 서로 직각인 토릭렌즈의 두 곡률의 합($C_x+C_y$)는 $$C_x+C_y=\frac{x^2+y^2}{2r_1}+\frac{x^2}{2}(\frac{1}{r_2}-\frac{1}{r_1})$$이며, 사축인 토릭렌즈의 두 곡률의 합 ($C_a+C_b$)은 $$(C_a+C_b)=\frac{x^2cos^2{\alpha}_1}{2r_1}+\frac{x^2cos^2{\alpha}_2}{2r_2}+\frac{y^2sin^2{\alpha}_1}{2r_1}+\frac{y^2sin^2{\alpha}_2}{2r_2}$$이다. $(C_1+C_2)+(C_1+C_2)_{90^{\circ}}$는 구면의 곡률 합$S_{S_1}+S_{S_2}$과 같은 값을 얻었다. 표면 곡률(Cx, Cy) 값을 포함한 사축 토릭렌즈의 합성 굴절력의 parameter S, C, ${\theta}$ 값을 다음과 같다. $$S=(n-1)\[\frac{C_x}{x^2}+\frac{C_y}{y^2}\]-\frac{C}{2},\;C=-\frac{2(n-1)}{sin2{\theta}}\[\frac{C_x}{x^2}+\frac{C_y}{y^2}\]$$ $${\theta}=\frac{1}{2}tan^{-1}\[-\frac{{C_xy^2sin2{\theta}_1}+{C_yx^2sin2{\theta}_2}}{{C_xy^2cos2{\theta}_1}+{C_yx^2cos2{\theta}_2}}\]$$.

  • PDF

단층 및 두부 방사선 계측사진을 이용한 정상교합자의 악관절에 관한 연구 (A STUDY OF THE TEMPOROMANDIBULAR JOINT IN NORMAL OCCLUSION USING T.M.J TOMOGRAM AND CEPHALOGRAM)

  • 백형선
    • 대한치과교정학회지
    • /
    • 제16권1호
    • /
    • pp.85-106
    • /
    • 1986
  • The purpose of this investigation was to know the means of the T.M.J. space and to compare spational differences in centric relation and centric occlusion by the T.M.J. Tomogram and to study the correlation between the articular eminence slope and the lingual surface slope of the maxillary central incisor by the Cephalogram in near normal occlusion subjects. These results could give contribution for the diagnosis of orthodontic treatment and T.M.J. dysfunction and the assessment of orthopedic treatment and orthognathic surgery. 44 young adults (28 men and 16 women, 21 to 27 years of age) were selected from the Dental students in Yonsei Univ. Criteria for selection was normal occlusion, no clinical signs and T.M.J. dysfunction, no history of orthodontic treatment, and no missing tooth. After submental vertex view analysis. each subject was given the T.M.J. Tomogram in centric relation and centric occlusion and the Cephalogram was given with Quint Sectograph. All data was recorded and statistically processed with the CYBER computer system. Results were analyzed: the following findings and conclusions were derived. 1. The mean value for the combined right and left anterior joint space was 2.549mm, the posterior space was 2.260mm, and superior space was 3.31mm in centric relation. The anterior space was 2.316mm, posterior space was 2.474mm, and superior space was 3.435mm in centric occlusion. 2. In the centric relation position, both condyles were placed more posterioly and superioly in their fossae than in the centric occlusion position by the spatial difference. 3. In the centric occlusion position, both condyles were more symmetrically placed in their fossae with equal anterior-posterioly rather than in the centric relation position. 4. The mean articular eminence angle was $48.19^{\circ}$ and the mean fossa height was 7.911mm. A strong positive correlation between the articular eminence angle and fossa height in T.M.J. Tomogram was found. 5. In Cephalometric analysis, there was a strong positive correlation between the articular eminence slope and the lingual surface slope of the upper central incisor to the FH plane, occlusal plane, and S-N plane. 6. There was moderate positive correlation between the S-E measurements and the fossa height, articular eminence angle, and DcGn < F-H.

  • PDF

모형시험 및 수치해석을 통한 경사 시스템 록볼트의 보강효과 분석 (Evaluation on Reinforcing Effect of Inclined System Bolting by Model Tests and Numerical Analysis)

  • 이재덕;김병일;유완규;한진태
    • 대한토목학회논문집
    • /
    • 제33권4호
    • /
    • pp.1529-1539
    • /
    • 2013
  • 최근에 일본의 시공사례에 따르면 터널확대를 위해 보호공(프로텍터)을 설치하고 기존 터널을 사용하면서 시공하는 경우에는 록볼트를 굴착방향에 수직하게 타설할 수 없어서 경사지게 타설하는 경우가 있다. 운용 중인 터널을 확대 시공하는 경우에는 작업조건이 매우 나쁘기 때문에 록볼트의 패턴(경사 록볼트 설치, 사전 록볼트 시공, 록볼트 제외 등)에 대한 검토가 필요하다. 이 연구에서는 모형시험을 이용하여 일반적으로 터널 굴착방향과 수직하게 설치되는 시스템 록볼트의 보강효과와 터널 굴착방향에 경사지게 설치되는 경사 시스템 록볼트의 보강효과를 비교하였다. 모형 록볼트의 설치각도, 설치간격, 정착 길이 등을 변화시켜 총 24회의 모형시험을 수행하였으며, 모형시험 결과 모형볼트 1개가 부담하는 면적에 대한 이완하중 발생률은 부담면적 감소에 따라 감소하는 것으로 나타났다. 또한, 모형볼트 정착 길이 변화에 따른 이완하중 발생률은 정착 길이가 길어질수록 감소하는 경향이 나타났다. 한편 터널 지보재 설치효과를 주변 지반의 공학적 특성 증가로 간주하는 지보재 모형화 방법에 의한 2차원 수치해석 결과가 모형시험의 처짐 증가량 발생경향을 유사하게 예측하는 것으로 나타나 본 해석 기법이 경사 시스템 록볼트의 보강효과를 적절히 모사할 수 있을 것으로 판단된다.

DEVELOPMENT OF A PERSIMMON HARVESTING SYSTEM

  • Kim, S. M.;Park, S. J.;Kim, C. S.;Kim, M. H.;Lee, C. H.;J. Y. Rhee
    • 한국농업기계학회:학술대회논문집
    • /
    • 한국농업기계학회 2000년도 THE THIRD INTERNATIONAL CONFERENCE ON AGRICULTURAL MACHINERY ENGINEERING. V.II
    • /
    • pp.472-479
    • /
    • 2000
  • A persimmon harvesting vehicle that can be operated in hilly orchards as well as a manipulator that can be used to harvest persimmons located in remote positions in the trees were designed and developed. The vehicle could be operated with keeping balanced position in an inclined field and its working platform could be moved up and down easy to approach fruits in a remote region with the aids of a hydraulic and a electrical and electronics systems. The weight of the vehicle was 927 kg and the center of gravity was located at 427 mm to the inner side from the center of a right driving caterpillar, 607 mm to a rear axle from the center of a front axle, and 562 mm to upward from ground. The automatic level control sensor for leveling the working platform was activated within 14.5 ∼ 16.5 degrees of slope variation. The total length of the manipulator was 1.39 m and weight is 975 g. It was powered by a 12 V geared motor to detach persimmon fruits with a rotational force. The gripper was made of plastic and rubber to increase a frictional force. In a performance evaluation test, static tipping angle, dynamic tipping angle toward front side when the vehicle was moving downward, climbing angle, driving speed of the vehicle were measured or calculated. In persimmon harvesting tests 24.9% of yield was increased by hand picking with the aid of the vehicle and additional 7% of yield were increased when the manipulator was used. Therefore, 99010 of total possible yield was achievable when both of the vehicle and the manipulator were used for the manual persimmon harvesting. Increase in 22.5% of total yield was achieved with the manipulator only.

  • PDF

여성노인의 태권에어로빅스 12주 훈련 후 몸통지르기 동작시 하지관절의 생체역학적 변화 (Biomechanical Alterations in the Lower limb Joints during the Punching Motion of Elderly Women after 12-Weeks of Taekwonaerobics Training)

  • 유실
    • 한국운동역학회지
    • /
    • 제19권4호
    • /
    • pp.637-645
    • /
    • 2009
  • 이 연구는 여성노인의 태권에어로빅스 12주 훈련 후 앞굽이 몸통지르기 동작시 하지관절의 생체역학적 변화를 구명하는 것이다. 대상자는 여성노인 10명이 참여하였으며 카메라(MCU-240) 7대와 지면반력기(Kist1er-9286AA) 2대를 이용하여 데이터를 수집하였다. 유의수준 .10에서 운동전 후 차이는 다음과 같다. 첫째, 최소 관절각의 변화는 발목의 저측/배측굴곡(왼쪽, $p=0.001^*$), 외번/내번(양쪽, $p=0.009^*$, $p=0.04^*$)과 무릎의 외전/내전(왼쪽, $p=0.04^*$) 및 엉덩이의 내측/외측 회전(양쪽, $p=0.07^*$, $p=0.02^*$)에서 통계적으로 유의하게 나타났다. 둘째, 최대 관절모멘트 변화는 발목관절의 외번/내번 모멘트(양쪽, $p=0.05^*$, $p=0.05^*$), 무릎관절의 외전/내전 모멘트(왼쪽, $p=0.08^*$) 및 엉덩이관절의 내측/외측 회전 모멘트(오른쪽, $p=0.09^*$)가 통계적으로 유의하게 나타났다. 셋째, 최대 관절파워의 변화는 엉덩이관절의 굴곡/신전(양쪽, $p=0.05^*$, $p=0.01^*$)과 내전/외전(양쪽, $p=0.02^*$, $p=0.00^*$) 및 무릎의 내전/외전(왼쪽, $p=0.00^*$) 파워가 통계적으로 유의한 차이를 보였다. 결론적으로 태권에어로빅스 몸통지르기동작이 여성노인들의 하지 관절에 부분적인 생체변화를 일으켰다.