• Title/Summary/Keyword: Revision repair

Search Result 59, Processing Time 0.029 seconds

Revision Rotator Cuff Repair (회전근 개 봉합술 후 재수술)

  • Kim, Young-Kyu;Kim, Dong-Wook
    • Journal of the Korean Arthroscopy Society
    • /
    • v.13 no.2
    • /
    • pp.119-125
    • /
    • 2009
  • The primary purposes of revision repair for a failed rotator cuff repair are a relief of pain and functional improvement. Therefore, revision repair is most proper in patients with the functional deficit accompanied with the shoulder weakness as well as the persistent pain. The important factor that is considered in revision repair is a quality of torn cuff. Especially, Care must be taken to ensure that the revision repair is possible, considering the size of tendon defect, atrophy of the muscle, fatty infiltration and extent of the retraction of tendon. Revision repair of a failed rotator cuff repair is more difficult, and the functional results are less satisfactory than those of primary repair, because excessive bursal scarring and tendon retraction may be exhibited, a large or massive tear is often detected, tear has usually been present for a long time, and a quality of muscle-tendon may be poor. So, we discuss our experiences related to revision repair after a failed cuff repair that has been recently introduced through the articles.

  • PDF

Efficient and Low-Cost Metal Revision Techniques for Post Silicon Repair

  • Lee, Sungchul;Shin, Hyunchul
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.14 no.3
    • /
    • pp.322-330
    • /
    • 2014
  • New effective techniques to repair "small" design errors in integrated circuits are presented. As semiconductor chip complexity increases and the design period becomes tight, errors frequently remain in a fabricated chip making revisions required. Full mask revision significantly increases the cost and time-to-market. However, since many "small" errors can be repaired by modifying several connections among the circuit blocks and spare cells, errors can frequently be repaired by revising metal layers. Metal only revision takes significantly less time and involves less cost when compared to full mask revision, since mask revision costs multi-million dollars while metal revision costs tens of thousand dollars. In our research, new techniques are developed to further reduce the number of metal layers to be revised. Specifically, we partition the circuit blocks with higher error probabilities and extend the terminals of the signals crossing the partition boundaries to the preselected metal repair layers. Our partitioning and pin extension to repair layers can significantly improve the repairability by revising only the metal repair layers. Since pin extension may increase delay slightly, this method can be used for non-timing-critical parts of circuits. Experimental results by using academia and industrial circuits show that the revision of the two metal layers can repair many "small" errors at low-cost and with short revision time. On the average, when 11.64% of the spare cell area and 24.72% of the extended pins are added to the original circuits, 83.74% of the single errors (and 72.22% of the double errors) can be corrected by using two metal revision. We also suggest methods to use our repair techniques with normal commercial vender tools.

Low-Cost Design for Repair by Using Circuit Partitioning (회로 분할을 사용한 저비용 Repair 기술 연구)

  • Lee, Sung-Chul;Yeo, Dong-Hoon;Shin, Ju-Yong;Kim, Kyung-Ho;Shin, Hyun-Chul
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.47 no.5
    • /
    • pp.48-55
    • /
    • 2010
  • As the complexity and the clock speed of semiconductor integrated circuits increase, silicon validation becomes important. In this research, we developed new post-silicon repair & revision techniques to reduce cost and time-to-market. Spare cells are fabricated with the original design and are used for repair when necessary. The interconnections are modified by repair layer revision. The repair cost can be reduced by logic partitioning. Experimental results show that these techniques are effective for low-cost and fast turnaround repair.

Proposing the Revision of Ondol Construction in the Standard Specification for Heritage Repair (문화재수리표준시방서의 온돌공사 개정 제안에 관한 연구)

  • Lim, Jun-Gu;Kim, Young-Jae
    • Journal of architectural history
    • /
    • v.32 no.5
    • /
    • pp.43-50
    • /
    • 2023
  • Ondol is a traditional underfloor heating system designated as a national intangible cultural heritage of Korea. The Cultural Heritage Administration (CHA) publishes a standard specification for the repair of cultural properties, including ondol. This standard specification is used as a guide for contractors who repair ondol in the field. However, the standard specification for ondol repair has some errors and is difficult to understand in the field. This paper proposes a revision of the standard specification for ondol repair. This study found that the standard specification for ondol repair has some problems in terms of the terminology and structure of ondol. These problems were sufficient to confuse ondol repairers in the field. Therefore, this study proposes to revise the standard specification to correct these errors and make it easier for ondol repairers in the field to understand. This study is expected to help recognize and preserve ondol as a cultural property and not just as a building.

Free Semitendinosus Tendon Graft in Re-ruptured Achilles Tendon (반건상근 건을 이용한 아킬레스건 재파열의 치료)

  • Ji, Jong-Hoon;Kim, Weon-Yoo;Kim, Young-Yel;Lee, Yeun-Soo;Yoon, Jong-Seoung
    • Journal of Korean Foot and Ankle Society
    • /
    • v.10 no.2
    • /
    • pp.259-263
    • /
    • 2006
  • The acute Achilles tendon rupture usually occurs to the people who participate in sports-related activities between 30 and 40 years of age. Recently surgical repair is the standard treatment in acute Achilles tendon rupture. After the Achilles tendon rupture in the left ankle, a 30-years old young man had been suffered from re-rupturing within three months after the primary repair. 2 years later, right-side Achilles tendon was reruptured after primary repair consequently. In the revision surgery, we performed V-Y advancement of the gastrocnemius-soleus fascia and reinforcement of the semitendinosus tendon. None of the English-literature was reported about using the semitendinosus tendon in revision surgery of the Achilles tendon retear previously. Therefore, we report this case and surgical technique because of the simple technique and the excellent results.

  • PDF

A Bayesian approach to maintenance strategy for non-renewing free replacement-repair warranty

  • Jung, K.M.
    • International Journal of Reliability and Applications
    • /
    • v.12 no.1
    • /
    • pp.41-48
    • /
    • 2011
  • This paper considers the maintenance model suggested by Jung and Park (2010) to adopt the Bayesian approach and obtain an optimal replacement policy following the expiration of NFRRW. As the criteria to determine the optimal maintenance period, we use the expected cost during the life cycle of the system. When the failure times are assumed to follow a Weibull distribution with unknown parameters, we propose an optimal maintenance policy based on the Bayesian approach. Also, we describe the revision of uncertainty about parameters in the light of data observed. Some numerical examples are presented for illustrative purpose.

  • PDF

Biomechanical Test for Repair Technique of Full-thickness Rotator Cuff Tear

  • Lim, Chae-Ouk;Park, Kyoung-Jin
    • Clinics in Shoulder and Elbow
    • /
    • v.19 no.1
    • /
    • pp.51-58
    • /
    • 2016
  • The arthroscopic rotator cuff repair is now considered a mainstream technique with highly satisfactory clinical results. However, concerns remain regarding healing failures for large and massive tears and high revision rate. In recent decades, various repair strategies and construct configurations have been developed for rotator cuff repair with the understanding that many factors contribute to the structural integrity of the repaired construct. The focus of biomechanical test in arthroscopic repair has been on increasing fixation strength and restoration of the footprint contact characteristics to provide early rehabilitation and improve healing. These include repaired rotator cuff tendon-footprint motion, increased tendon-footprint contact area and pressure, and tissue quality of tendon and bone. Recent studies have shown that a transosseous tunnel technique provides improved contact area and pressure between rotator cuff tendon and insertion footprint, and the technique of using double rows of suture anchors to recreate the native footprint attachment has been recently described. The transosseous equivalent suture bridge technique has the highest contact pressure and fixation force. In this review, the biomechanical tests about repair techniques of rotator cuff tear will be reviewed and discussed.

Scar Revision in Patient with Secondary Cleft Lip Deformity Using Straight Line Repair-Report of Case (직선 봉합법을 이용한 편측 구순열의 반흔성형술 증례)

  • Lee, In-Woo;Lee, Ju-Hwan;Seo, Byoung-Moo
    • Korean Journal of Cleft Lip And Palate
    • /
    • v.12 no.2
    • /
    • pp.95-100
    • /
    • 2009
  • In spite of all fine methods developed for treating cleft lip, a certain percentage of cases might still need secondary correction. Generally, secondary revision of cleft lip is much difficult to produce esthetic outcome, because the cleft lip scar gives a variable symmetrical and anatomic defect that may not be possible to make inconspicuous of this scar and rebuild good esthetics. In this case report, a five year-old girl was underwent secondary cleft lip repair using straight line technique to correct unfavorable postoperative scar, peaking of Cupid's bow, notching of vermillion and shortened lip on cleft side with simultaneous repairing cleft palatal fistula. After operation, the secondary deformity was much improved, but, long term follow up is needed to evaluate the additional postoperative deformity might be happen during growth.