• Title/Summary/Keyword: Revision arthroplasty

Search Result 51, Processing Time 0.02 seconds

Stenotrophomonas maltophilia Periprosthetic Joint Infection after Hip Revision Arthroplasty

  • Valentino Latallade;Carlos Lucero;Pablo Slullitel;Martin Buttaro
    • Hip & pelvis
    • /
    • v.35 no.2
    • /
    • pp.142-146
    • /
    • 2023
  • Stenotrophomonas maltophilia, a well-established opportunistic bacterium, primarily impacts healthcare settings. Infection of the musculoskeletal system with this bacterium is rare. We report on the first known case of hip periprosthetic joint infection (PJI) caused by S. maltophilia. The potential for development of a PJI caused by this pathogen should be considered by orthopaedic surgeons, particularly in patients with multiple severe comorbidities.

Discovery Elbow System arthroplasty polyethylene bearing exchange: outcomes and experience

  • Daniel L J Morris;Katherine Walstow;Lisa Pitt;Marie Morgan;Amol A Tambe;David I Clark;Timothy Cresswell;Marius P Espag
    • Clinics in Shoulder and Elbow
    • /
    • v.27 no.1
    • /
    • pp.18-25
    • /
    • 2024
  • Background: The Discovery Elbow System (DES) utilizes a polyethylene bearing within the ulnar component. An exchange bearing requires preoperative freezing and implantation within 2 minutes of freezer removal to allow insertion. We report our outcomes and experience using this technique. Methods: This was an analysis of a two-surgeon consecutive series of DES bearing exchange. Inclusion criteria included patients in which exchange was attempted with a minimum 1-year follow-up. Clinical and radiographic review was performed 1, 2, 3, 5, 8 and 10 years postoperative. Outcome measures included range of movement, Oxford Elbow Score (OES), Mayo Elbow Performance Score (MEPS), complications and requirement for revision surgery. Results: Eleven DESs in 10 patients were included. Indications were bearing wear encountered during humeral component revision (n=5); bearing failure (n=4); and infection treated with debridement, antibiotics and implant retention (DAIR; n=2). Bearing exchange was conducted on the first attempt in 10 cases. One case required a second attempt. One patient developed infection postoperatively managed with two-stage revision. Mean follow-up of the bearing exchange DES was 3 years. No further surgery was required, with no infection recurrence in DAIR cases. Mean elbow flexion-extension and pronosupination arcs were 107°(±22°) and 140° (±26°). Mean OES was 36/48 (±12) and MEPS was 83/100 (±19). Conclusions: Our results support the use of DES bearing exchange in cases of bearing wear with well-fixed stems or acute infection. This series provides surgeons managing DES arthroplasty with management principles, successful and reproducible surgical techniques and expected clinical outcomes in performing DES polyethylene bearing exchange. Level of evidence: IV.

Implant selection for successful reverse total shoulder arthroplasty

  • Joo Han Oh;Hyeon Jang Jeong;Yoo-Sun Won
    • Clinics in Shoulder and Elbow
    • /
    • v.26 no.1
    • /
    • pp.93-106
    • /
    • 2023
  • Reverse total shoulder arthroplasty (RTSA) emerged as a new concept of arthroplasty that does not restore normal anatomy but does restore function. It enables the function of the torn rotator cuff to be performed by the deltoid and shows encouraging clinical outcomes. Since its introduction, various modifications have been designed to improve the outcome of the RTSA. From the original cemented baseplate with peg or keel, a cementless baseplate was designed that could be fixed with central and peripheral screws. In addition, a modular-type glenoid component enabled easier revision options. For the humeral component, the initial design was an inlay type of long stem with cemented fixation. However, loss of bone stock from the cemented stem hindered revision surgery. Therefore, a cementless design was introduced with a firm metaphyseal fixation. Furthermore, to prevent complications such as scapular notching, the concept of lateralization emerged. Lateralization helped to maintain normal shoulder contour and better rotator cuff function for improved external/internal rotation power, but excessive lateralization yielded problems such as subacromial notching. Therefore, for patients with pseudoparalysis or with risk of subacromial notching, a medial eccentric tray option can be used for distalization and reduced lateralization of the center of rotation. In summary, it is important that surgeons understand the characteristics of each implant in the various options for RTSA. Furthermore, through preoperative evaluation of patients, surgeons can choose the implant option that will lead to the best outcomes after RTSA.

Outcomes and Complications of Total Elbow Arthroplasty (주관절 치환술의 임상 결과와 합병증)

  • Park, Min-Jong
    • Clinics in Shoulder and Elbow
    • /
    • v.14 no.1
    • /
    • pp.146-152
    • /
    • 2011
  • Purpose: To describe the recent clinical results and complications of total elbow arthroplasty based on the literature review. Materials and Methods: The indications of total elbow arthroplasty include rheumatoid or inflammatory arthritis, posttraumatic arthritis, anklylosed elbow, tumor resection which cannot recover elbow function by other reconstructive procedures, and comminuted distal humerus fracture in elderly patients. Complications are aspetic loosening, infection, prosthesis fracture, periprosthetic fracture, ulnar neuropathy, ectopic ossification, triceps insufficiency, dislocation, and bushing wear. Results and Conclusion: Mean 10 year survival rate following total elbow arthroplasty has been reported 85% on the basis of revision. The prognosis in patients with an inflammatory arthritis is reported to be best, and loosening rate in patients with a posttraumatic arthritis tends to be high. Complication rate is known to be higher than that of other joint arthroplasty. In particular, deep infection occurs in 3~5% of the patients. Total elbow arthroplasty provide satisfactory results when it is performed properly in selected patients who have an elbow joint with irreversible dysfunction and low level activities.

Arthrodesis of the Knee with Vascularized Fibular Graft - A Case of Infected Total Knee Arthroplasty - (혈관 부착 비골 전위술을 이용한 슬관절 유합술 - 슬관절 전치환술 후 감염이 합병된 증례 -)

  • Chung, Duke-Whan;Han, Chung-Soo;Lee, Jae-Hoon;Jeong, Sun-Teak;Park, Jin-Sung
    • Archives of Reconstructive Microsurgery
    • /
    • v.15 no.2
    • /
    • pp.111-116
    • /
    • 2006
  • An infection after total knee arthroplasty has many complications such as severe bone defect, skin and soft tissue problems, devastated general condition, so arthrodesis is preferred as treatment option. However, poor bony contact due to severe bone defect and inadequate conditions of the soft tissue often cause nonunion or severe limb shortening after arthrodesis. More over these conditions, it is not easy to choose appropriate fixative devices. In these situations, the arthrodesis using vascularized fibular graft can be the solution. Vascularized fibular graft (VFG) can playa role as a suitable material for the treatment of bone defects. And VFG can overcome poor blood circulation caused by scar tissues, and can be relatively more durable and adequate length. In the long term, VFG can be hypertrophied by weight bearing, and will give mechanical stablility. The purpose of the paper is to report the successful results of arthrodesis using VFG in a patient who got extensive bone defect after failed revision total knee arthroplasty with infection.

  • PDF

Functional Outcome after Reimplantation in Patients Treated with and without an Antibiotic-Loaded Cement Spacers for Hip Prosthetic Joint Infections

  • Michele Fiore;Claudia Rondinella;Azzurra Paolucci;Lorenzo Morante;Massimiliano De Paolis;Andrea Sambri
    • Hip & pelvis
    • /
    • v.35 no.1
    • /
    • pp.32-39
    • /
    • 2023
  • Purpose: A staged revision with placement of a temporary antibiotic-loaded cement spacer after removal of the implant is the "gold standard" for treatment of chronic prosthetic joint infection (PJI). It enables local delivery of antibiotics, maintenance of limb-length and mobility, easier reimplantation. However, bacterial colonization of spacers and mechanical complications can also occur. The aim of this study is to evaluate functional results and infection control in two-stage treatment of total hip arthroplasty (THA) PJI with and without a spacer. Materials and Methods: A retrospective review of 64 consecutive patients was conducted: 34 underwent two-stage revision using a cement spacer (group A), 30 underwent two-stage revision without a spacer (group B). At the final follow-up, functional evaluation of patients with a THA in site, without PJI recurrence, was performed using the Harris hip score (HHS). Measurement of limb-length and off-set discrepancies was performed using anteroposterior pelvic X-rays. Results: Most patients in group B were older with more comorbidities preoperatively. Thirty-three patients (97.1%) in group A underwent THA reimplantation versus 22 patients (73.3%) in group B (P<0.001). No significant differences in limb-length and off-set were observed. The results of functional evaluation performed during the final follow-up (mean, 41 months) showed better function in patients in group A (mean HHS, 76.3 vs. 55.9; P<0.001). Conclusion: The use of antibiotic-loaded cement spacer seems superior in terms of functional outcomes and reimplantation rate. Resection arthroplasty might be reserved as a first-stage procedure in patients who are unfit, who might benefit from a definitive procedure.

Hip Arthroplasty Using the Bencox® Hip System: An Evaluation of a Consecutive Series of One Thousand Cases

  • Lee, Joong-Myung;Sim, Young-Suk;Choi, Dae-Sung
    • Hip & pelvis
    • /
    • v.30 no.4
    • /
    • pp.210-218
    • /
    • 2018
  • Purpose: This is a report on the outcomes associated with a consecutive series of 1,000 cementless hip arthroplasties utilizing the $Bencox^{(R)}$ hip stem-the first Korean-developed hip prosthesis. Materials and Methods: A consecutive series of 1,000 hip arthroplasties using the $Bencox^{(R)}$ hip stem were analyzed, starting from its initial release (September 2006) until June 2014. Patients in this consecutive series underwent surgery for fractures (n=552), arthritis (n=155), avascular necrosis (n=209), and revisions (n=84). Of these 1,000 cases, patients with a minimum follow-up of at least 1 year (n=616) were retrospectively analyzed for radiographic and clinical outcomes (i.e., Harris hip score). The stability of the prosthesis was evaluated by examining subsidence. Results: During the follow-up period (mean follow-up period of 54.8 months), there were 2 cases requiring revision of the femoral stem-both were caused by periprosthetic fractures and neither involved stem loosening. The mean Harris hip score during follow-up was 95.5. Bone ongrowth occurred in 95% of patients; no cases of subsidence or aseptic loosening of the stem were detected, and no cases of postoperative complications such as ceramic breakage were observed. Conclusion: Clinical and radiographic evaluations of hip arthroplasty using the $Bencox^{(R)}$ hip stem revealed excellent outcomes with an average of 54.8 month follow-up in a consecutive series of 1,000 cases.

Osteolytic Lesion of the Fibular Head after Cemented Total Knee Arthroplasty (슬관절 전치환술 후 비골 두에 발생한 골용해성 병변)

  • Lee, Chae-Chil;Park, Ki-Bong;Hwang, Il-Yeong;Yang, Doo-Guen
    • Journal of the Korean Orthopaedic Association
    • /
    • v.56 no.1
    • /
    • pp.87-92
    • /
    • 2021
  • The radiographic findings of an osteolytic lesion in the knee may indicate numerous possible impressions. Furthermore, osteolysis is a possible cause if there is a surgical history of total knee arthroplasty (TKA). The authors diagnosed osteolysis of the fibular head after aseptic loosening of the tibial component of a cemented TKA in an 83-year-old female patient who visited with right knee pain and report their treatment with revision TKA along with a literature review.

Intramedullary fibula strut bone allograft in a periprosthetic humeral shaft fracture with implant loosening after total elbow arthroplasty

  • Jo, Young-Hoon;Lee, Seung Gun;Kook, Incheol;Lee, Bong Gun
    • Clinics in Shoulder and Elbow
    • /
    • v.23 no.3
    • /
    • pp.152-155
    • /
    • 2020
  • Periprosthetic fracture after total elbow replacement surgery is a difficult complication to manage, especially when it comes together with implant loosening. If stem revision and internal fixation of the periprosthetic fracture are performed simultaneously, this would be a very challenging procedure. Most of total elbow replacement implants are cemented type. Cement usage at periprosthetic fracture site may interfere healing of fractured site. Authors underwent internal fixation with use of locking plate and cerclage wire for periprosthetic fracture, allogenous fibular strut bone inserted into the humerus intramedullary canal allowing the fractured site to be more stable without cement usage. At 10-month follow-up, the complete union and good clinical outcome was achieved. We present a novel technique for treating periprosthetic fracture with implant loosening after total elbow replacement surgery, using intramedullary allogenous fibula strut bone graft.