• Title/Summary/Keyword: Reverse shoulder

Search Result 90, Processing Time 0.019 seconds

Patient-specific implants in reverse shoulder arthroplasty

  • Emil R Haikal;Mohamad Y. Fares;Joseph A. Abboud
    • Clinics in Shoulder and Elbow
    • /
    • v.27 no.1
    • /
    • pp.108-116
    • /
    • 2024
  • Reverse total shoulder arthroplasty (RTSA) is widely popular among shoulder surgeons and patients, and its prevalence has increased dramatically in recent years. With this increased use, the indicated pathologies associated with RTSA are more likely to be encountered, and challenging patient presentations are more likely to be seen. One prominent challenging presentation is RTSA patients with severe glenoid bone loss. Several techniques with varying degrees of invasiveness, including excessive reaming, alternate centerline, bone grafting, and patient-specific implants (PSIs), have been developed to treat patients with this presentation. PSI treatment uses a three-dimensional reconstruction of a computed tomography scan to design a prosthetic implant or component customized to the patient's glenoid morphology, allowing compensation for any significant bone loss. The novelty of this technology implies a paucity of available literature, and although many studies show that PSIs have good potential for solving challenging shoulder problems, some studies have reported questionable and equivocal outcomes. Additional research is needed to explore the indications, outcomes, techniques, and cost-efficiency of this technology to help establish its role in current treatment guidelines and strategies.

Online resources for information on shoulder arthroplasty: an assessment of quality and readability

  • Mohamad Y. Fares;Jaspal Singh;Amar S. Vadhera;Jonathan Koa;Peter Boufadel;Joseph A. Abboud
    • Clinics in Shoulder and Elbow
    • /
    • v.26 no.3
    • /
    • pp.238-244
    • /
    • 2023
  • Background: Many patients use online resources to educate themselves on surgical procedures and make well-informed healthcare decisions. The aim of our study was to evaluate the quality and readability of online resources exploring shoulder arthroplasty. Methods: An internet search pertaining to shoulder arthroplasty (partial, anatomic, and reverse) was conducted using the three most popular online search engines. The top 25 results generated from each term in each search engine were included. Webpages were excluded if they were duplicates, advertised by search engines, subpages of other pages, required payments or subscription, or were irrelevant to our scope. Webpages were classified into different source categories. Quality of information was assessed by HONcode certification, Journal of the American Medical Association (JAMA) criteria, and DISCERN benchmark criteria. Webpage readability was assessed using the Flesch reading ease score (FRES). Results: Our final dataset included 125 web pages. Academic sources were the most common with 45 web pages (36.0%) followed by physician/private practice with 39 web pages (31.2%). The mean JAMA and DISCERN scores for all web pages were 1.96±1.31 and 51.4±10.7, respectively. The total mean FRES score was 44.0±11.0. Only nine web pages (7.2%) were HONcode certified. Websites specified for healthcare professionals had the highest JAMA and DISCERN scores with means of 2.92±0.90 and 57.96±8.91, respectively (P<0.001). HONcode-certified webpages had higher quality and readability scores than other web pages. Conclusions: Web-based patient resources for shoulder arthroplasty information did not show high-quality scores and easy readability. When presenting medical information, sources should maintain a balance between readability and quality and should seek HONcode certification as it helps establish the reliability and accessibility of the presented information. Level of evidence: IV.

Use of custom glenoid components for reverse total shoulder arthroplasty

  • Punyawat Apiwatanakul;Prashant Meshram;Andrew B. Harris;Joel Bervell;Piotr Lukasiewicz;Ridge Maxson;Matthew J. Best;Edward G. McFarland
    • Clinics in Shoulder and Elbow
    • /
    • v.26 no.4
    • /
    • pp.343-350
    • /
    • 2023
  • Background: Our purpose was to evaluate a custom reverse total shoulder arthroplasty glenoid baseplate for severe glenoid deficiency, emphasizing the challenges with this approach, including short-term clinical and radiographic outcomes and complications. Methods: This was a single-institution, retrospective series of 29 patients between January 2017 and December 2022 for whom a custom glenoid component was created for extensive glenoid bone loss. Patients were evaluated preoperatively and at intervals for up to 5 years. All received preoperative physical examinations, plain radiographs, and computed tomography (CT). Intra- and postoperative complications are reported. Results: Of 29 patients, delays resulted in only undergoing surgery, and in three of those, the implant did not match the glenoid. For those three, the time from CT scan to implantation averaged 7.6 months (range, 6.1-10.7 months), compared with 5.5 months (range, 2-8.6 months) for those whose implants fit. In patients with at least 2-year follow-up (n=9), no failures occurred. Significant improvements were observed in all patient-reported outcome measures in those nine patients (American Shoulder and Elbow Score, P<0.01; Simple Shoulder Test, P=0.02; Single Assessment Numeric Evaluation, P<0.01; Western Ontario Osteoarthritis of the Shoulder Index, P<0.01). Range of motion improved for forward flexion and abduction (P=0.03 for both) and internal rotation up the back (P=0.02). Pain and satisfaction also improved (P<0.01 for both). Conclusions: Prolonged time (>6 months) from CT scan to device implantation resulted in bone loss that rendered the implants unusable. Satisfactory short-term radiographic and clinical follow-up can be achieved with a well-fitting device. Level of evidence: III.

The impact of modern airport security protocols on patients with total shoulder replacements

  • Michael D. Scheidt;Neal Sethi;Matthew Ballard;Michael Wesolowski;Dane Salazar;Nickolas Garbis
    • Clinics in Shoulder and Elbow
    • /
    • v.26 no.4
    • /
    • pp.416-422
    • /
    • 2023
  • Background: Advancements in airport screening measures in response to 9/11 have resulted in increased false alarm rates for patients with orthopedic and metal implants. With the implementation of millimeter-wave scanning technology, it is important to assess the changes in airport screening experiences of patients who underwent total shoulder arthroplasty (TSA). Methods: Here, 197 patients with prior anatomic and reverse TSA completed between 2013 and 2020 responded to a questionnaire regarding their experiences with airport travel screening after their operation. Of these patients, 86 (44%) stated that they had traveled by plane, while 111 (56%) had not. The questionnaire addressed several measures including the number of domestic and international flights following the operation, number of false alarm screenings by the millimeter-wave scanner, patient body habitus, and presence of additional metal implants. Results: A total of 53 patients (62%) responded "yes" to false screening alarms due to shoulder arthroplasty. The odds of a false screening alarm for patients with other metal implants was 5.87 times that of a false screening alarm for patients with no other metal implants (P<0.1). Of a reported 662 flights, 303 (45.8%) resulted in false screening alarms. Greater body mass index was not significantly lower in patients who experienced false screening alarms (P=0.30). Conclusions: Patients with anatomic and reverse TSA trigger false alarms with millimeter-wave scanners during airport screening at rates consistent with prior reports following 9/11. Patient education on the possibility of false alarms during airport screening is important until improvements in implant identification are made. Level of evidence: IV.

Short-term comparative outcomes between reverse shoulder arthroplasty for shoulder trauma and shoulder arthritis: a Southeast Asian experience

  • Ng, Julia Poh Hwee;Tham, Sherlyn Yen Yu;Kolla, Saketh;Kwan, Yiu Hin;Tan, James Chung Hui;Teo, Timothy Wei Wen;Wee, Andy Teck Huat;Toon, Dong Hao
    • Clinics in Shoulder and Elbow
    • /
    • v.25 no.3
    • /
    • pp.210-216
    • /
    • 2022
  • Background: Reverse shoulder arthroplasty (RSA), first introduced as a management option for cuff tear arthropathy, is now an accepted treatment for complex proximal humeral fractures. Few studies have identified whether the outcomes of RSA for shoulder trauma are comparable to those of RSA for shoulder arthritis. Methods: This is a retrospective, single-institution cohort study of all patients who underwent RSA at our institution between January 2013 and December 2019. In total, 49 patients met the inclusion criteria. As outcomes, we evaluated the 1-year American Shoulder and Elbow Surgeons (ASES) and Constant shoulder scores, postoperative shoulder range of motion, intra- and postoperative complications, and cumulative revision rate. The patients were grouped based on preoperative diagnosis to compare postoperative outcomes across two broad groups. Results: The median follow-up period was 32.8 months (interquartile range, 12.6-66.6 months). The 1-year visual analog scale, range of motion, and Constant and ASES functional scores were comparable between RSAs performed to treat shoulder trauma and that performed for arthritis. The overall complication rate was 20.4%, with patients with a preoperative diagnosis of arthritis having significantly more complications than those with a preoperative diagnosis of trauma (34.8% vs. 7.7%). Conclusions: Patients who underwent RSA due to a proximal humeral fracture or dislocation did not fare worse than those who underwent RSA for arthritis at 1 year, in terms of both functional and radiological outcomes.

Radiologic Comparison of Humeral Position according to the Implant Designs Following Reverse Shoulder Arthroplasty: Analysis between Medial Glenoid/Medial Humerus, Lateral Glenoid/Medial Humerus, and Medial Glenoid/Lateral Humerus Designs

  • Cho, Nam Su;Nam, Ju Hyun;Hong, Se Jung;Kim, Tae Wook;Lee, Myeong Gu;Ahn, Jung Tae;Rhee, Yong Girl
    • Clinics in Shoulder and Elbow
    • /
    • v.21 no.4
    • /
    • pp.192-199
    • /
    • 2018
  • Background: The currently available reverse shoulder arthroplasty (RSA) designs can be classified into medial glenoid/medial humerus (MGMH), lateral glenoid/medial humerus (LGMH), and medial glenoid/lateral humerus (MGLH) prosthesis designs. The purpose of this study was to radiologically analyze the effect of different RSA designs on humeral position following RSA. Methods: A total of 50 patients who underwent primary RSA were retrospectively analyzed. Among 50 patients, 33 patients (group A: MGMH) underwent RSA with Aequalis system (Wright, Inc, Bloomington, MN, USA), 6 (group B: LGMH) with Aequalis system using bony increased offset, and 11 (group C: MGLH) with Aequalis Ascend Flex system. The acromiohumeral distance, acromioepiphyseal distance (AED), lateral humeral offset (LHO), LHO from the center of rotation ($LHO^{COR}$), and deltoid length were radiologically measured to quantify the distalization and lateralization of the humerus. Results: The increment in postoperative AED was $19.92{\pm}3.93mm$ in group A, $24.52{\pm}5.25mm$ in group B, and $25.97{\pm}5.29mm$ in group C, respectively (p=0.001). The increment in postoperative LHO was $0.13{\pm}6.30mm$, $8.00{\pm}12.14mm$, and $7.42{\pm}6.88mm$, respectively (p=0.005). The increment in postoperative $LHO^{COR}$ was $20.76{\pm}6.06mm$, $22.04{\pm}5.15mm$, and $28.11{\pm}4.14mm$, respectively (p=0.002). Conclusions: The radiologic analysis of the effect of different RSA designs on humeral position following RSA showed significant differences in the increment in postoperative AED, LHO, and $LHO^{COR}$ between the 3 groups. Therefore, MGLH design seems to be more effective for humeral distalization and lateralization compared to original Grammont design.

Effect of Preoperative Fatty Degeneration of the Deltoid and the Teres Minor Muscles on the Clinical Outcome after Reverse Total Shoulder Arthroplasty

  • Moon, Sung-Hoon;Nam, Woo-Dong;Rheu, Chang-Hyun;Lee, Jae-Woo
    • Clinics in Shoulder and Elbow
    • /
    • v.18 no.3
    • /
    • pp.138-143
    • /
    • 2015
  • Background: To evaluate the effect of preoperative fatty degeneration of deltoid and teres minor muscles on the clinical outcome in patient with reverse total shoulder arthroplasty (RTSA). Methods: Nineteen patients with RTSA were enrolled. The mean follow-up period was 16.1 months. The fatty degeneration of three distinct parts in each deltoid and the teres minor muscle was measured using a preoperative magnetic resonance imaging. Postoperatively, the muscle strengths for forward elevation (FE), abduction (Abd), and external rotation (ER) were measured using a myometer at the last follow-up. The parameters for clinical outcome were Constant Score (CS) and Korean Shoulder Score (KSS). Results: The number of cases was 10 in group 1 and 9 in group 2. The strength of FE and Abd were significantly higher in group 1 (p<0.001 and p<0.001, respectively), and the strength of ER was not different significantly between two groups (p=0.065). For the clinical outcome, both CS and KSS were higher in group 1 (p=0.002 and p=0.002, respectively). The number of patients in group A was 11, and group B was 8. Although there was not a significant difference in terms of FE and Abd between group A and B (p=0.091, p=0.238), ER was significantly higher in group A (p=0.012). We did not find a significant difference in the clinical scores (CS, p=0.177 and KSS, p=0.238). Conclusions: These findings suggest the importance of a preoperative evaluation of the fatty degeneration of deltoid and teres minor muscles for predicting postoperative strength and clinical outcome.

Implant selection for successful reverse total shoulder arthroplasty

  • Joo Han Oh;Hyeon Jang Jeong;Yoo-Sun Won
    • Clinics in Shoulder and Elbow
    • /
    • v.26 no.1
    • /
    • pp.93-106
    • /
    • 2023
  • Reverse total shoulder arthroplasty (RTSA) emerged as a new concept of arthroplasty that does not restore normal anatomy but does restore function. It enables the function of the torn rotator cuff to be performed by the deltoid and shows encouraging clinical outcomes. Since its introduction, various modifications have been designed to improve the outcome of the RTSA. From the original cemented baseplate with peg or keel, a cementless baseplate was designed that could be fixed with central and peripheral screws. In addition, a modular-type glenoid component enabled easier revision options. For the humeral component, the initial design was an inlay type of long stem with cemented fixation. However, loss of bone stock from the cemented stem hindered revision surgery. Therefore, a cementless design was introduced with a firm metaphyseal fixation. Furthermore, to prevent complications such as scapular notching, the concept of lateralization emerged. Lateralization helped to maintain normal shoulder contour and better rotator cuff function for improved external/internal rotation power, but excessive lateralization yielded problems such as subacromial notching. Therefore, for patients with pseudoparalysis or with risk of subacromial notching, a medial eccentric tray option can be used for distalization and reduced lateralization of the center of rotation. In summary, it is important that surgeons understand the characteristics of each implant in the various options for RTSA. Furthermore, through preoperative evaluation of patients, surgeons can choose the implant option that will lead to the best outcomes after RTSA.