• Title/Summary/Keyword: Reverse power

Search Result 714, Processing Time 0.036 seconds

Energy Harvesting from Reverse Electrodialysis in Ion-Selective Membrane Formed with Self-Assembled Nanoparticles (미세유체칩 내 자기조립화된 나노입자로 이루어진 이온교환막을 이용한 역전기투석 에너지 발전)

  • Choi, Eunpyo;Kwon, Kilsung;Kim, Daejoong;Park, Jungyul
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.5
    • /
    • pp.437-441
    • /
    • 2014
  • This paper presents a novel microplatform for high power generation based on reverse electrodialysis. The ideal cation-selective membrane for power generation was realized using geometrically controlled in situ self-assembled nanoparticles. Our proposed membranes can be constructed through a simple and cost-effective process that uses microdroplet control with nanoparticles in a microchannel. Another advantage of our system is that the maximum power and energy conversion efficiency can be improved by changing the geometry of the microchannel and proper selection of the nanoparticle size and material. This proposed platform can be used to supply power sources to other microdevices and contribute to a fundamental understanding of ion transport behavior and the power generation mechanism.

Performance of SIR-based power control using unused OVSF codes for WCDMA reverse link receiver (미사용 OVSF 부호를 이용한 WCDMA 역방향 링크 수신기의 SIR 기반 전력제어 성능 분석)

  • 이영용;박수진;안재민;임민중;정성현;최형진
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.40 no.7
    • /
    • pp.282-292
    • /
    • 2003
  • In this paper, we evaluate the performance of WCDMA reverse link receiver system with closed loop fast transmit power control (TPC). For fast power control, SIR must be measured precisely. We propose a new SIR measurement algorithm having a simple structure. The proposed algorithm uses unused OVSF code for interference power evaluation. The proposed SIR measurement algorithm is compared to the conventional SIR measurement algorithm in Ref.$^{[1]}$ under closed loop fast TPC. We adopted WMSA channel estimation filter with Κ=2 for mobile radio channel estimation and considered one slot TPC delay. Extensive computer simulation results show that the proposed algorithm using unused OVSF code reduces the required Ε$_{b}$$_{0}$ at the BER of 10$^{-3}$ up to 0.9㏈ and has an improved TPC error performance compared to the conventional algorithm.

Power Consumption Analysis of High-Level Obfuscation for Mobile Software (모바일 소프트웨어를 위한 고급수준 난독처리 기법의 전력 소모량 분석)

  • Lee, Jin-Young;Chang, Hye-Young;Cho, Seong-Je
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.15 no.12
    • /
    • pp.1008-1012
    • /
    • 2009
  • Obfuscation is known as one of the most effective methods to protect software against malicious reverse engineering transforming the software into more complicated one with still preserving the original semantic. However, obfuscating a program can increase both code size of the program and execution time compared to the original program. In mobile devices, the increases of code size and execution time incur the waste of resources including the increase of power consumption. This paper has analyzed the effectiveness of some high-level obfuscation algorithms as well as their power consumption with implementing them under an embedded board equipped with ARM processor. The analysis results show that there is (are) an efficient obfuscation method(s) in terms of execution time or power consumption according to characteristics of a given program.

Evaluation of Reverse Electrodialysis based on the Number of Cell Pairs and Stack Size Using Patterned Ion Exchange Membrane (패턴형 이온교환막을 이용한 스택의 셀 수 및 크기에 따른 역전기투석 성능 평가)

  • Dong-Gun Lee;Hanki Kim;Namjo Jeong;Young Sun Mok;Jiyeon Choi
    • New & Renewable Energy
    • /
    • v.19 no.2
    • /
    • pp.31-39
    • /
    • 2023
  • Salinity gradient energy can be generated from a mixture of water streams with different salt concentrations by using reverse electrodialysis (RED). In this study, we evaluated the effect of stack size and number of cell pairs on the energy efficiency and specific energy of the RED process. Additionally, we studied the prementioned parameters to maximize the power density of RED. The performance of the RED stack which used a patterned ion exchange membrane, was evaluated as a function of stack size and feed flow rate. Moreover, it was noted that an increase in stack size increased the ion movement through the ion exchange membrane. Furthermore, an increase in feed flow rate led to a reduction in the concentration variation, resulting in an increase in OCV and power density. The energy efficiency and specific energy for 100 cells in the 10 × 10 cm2 stack were the highest at 12% and 0.05 kWh/m3, respectively, while the power density from 0.33 cm/s to 5 × 5 cm2 stack was the highest at 0.53 W/m2. The study showed that the RED performance can be improved by altering the size of the stack and the number of cell pairs, thereby positively affecting energy efficiency and specific energy.

A Bitarray-Based Reverse Routing Method in Wireless Sensor Networks (무선 센서 네트워크에서 역방향 통신을 위한 비트열기반 경로설정 방법)

  • Kim, Seon-Hwan;Lee, Myung-Sub;Kim, Chong-Gun;Park, Chang-Hyeon
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.9 no.4
    • /
    • pp.80-89
    • /
    • 2010
  • Most of the discussed power efficient routing algorithms, such as LEACH, PEDAP and etc., assume that a base station has infinite resources and there is no traffic limit. However, these assumptions cannot be applied to typical wireless sensor network environments, especially a small sensor network using a normal node as the base station. Moreover, many studies on the wireless sensor networks have not been considering the reverse transmission scheme which transmits data from a sink node to the normal nodes. We propose a bitarray-based reverse routing method which is a power efficient routing algorithm for the wireless sensor networks. The proposed method can be easily implemented by using the tree-based routing scheme and can be worked well with the small memory size for the address of sensor nodes. The experimental result shows that the amount of message transmission of the proposed bitarray-based reverse routing method can be reduced about 61.3% or more compared to the previous methods.

Inquiry of New Topology for Grid-connected Photovoltaic Inverter (PV용 계통연계형 인버터의 새로운 Topology 고찰)

  • 정영석;유권종
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.248-251
    • /
    • 1999
  • Recently, according to developing industry and life style, power consumption have been increased year after year. Currently these much power demand from power consumer is weakening the allowable power reverse margin in summer. As on of the remedies about this problem, the small scale grid-connected photovoltaic system is considered for auxiliary power source. Generally, grid-connected inverter have a isolation transformer for electrical isolation from utility. This paper propose transformerless system topology an inquiry the validity using simulation.

  • PDF

CMOS Power Amplifier for PCS (PCS 용 CMOS 전력 증폭기)

  • 윤영승;주리아;손영찬;유상대
    • Proceedings of the IEEK Conference
    • /
    • 1999.11a
    • /
    • pp.1163-1166
    • /
    • 1999
  • In this paper, A CMOS power amplifier for PCS is designed with 0.65-$\mu\textrm{m}$ CMOS technology. Differential cascode structure is used which has good reverse isolation and wide voltage swing. This amplifier circuits consist of three stages which are power amplification stage, driver stage and power control stage. We obtain output power of 30 ㏈m, IMD3 of -31㏈c and efficiency of 30 % at input power of 4 ㏈m.

  • PDF

Failure Analysis of Circulating Water Pump Shaft in Power Plant (발전 계획에서 순환 물 펌프 고장 분석)

  • Lee, Jaehong;Jung, Nam-gun
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.7 no.1
    • /
    • pp.125-128
    • /
    • 2021
  • This paper presents the root cause failure analysis of the circulating water pump in the 560 MW thermal power plant. A fractured austenitic stainless-steel shaft operated for 24 years was examined. Fracture morphology was investigated by micro and macro-fractographic analysis. The metallurgical analyses including chemical analysis, metallography and hardness testing were performed. The analysis reveals that the pump shaft was fractured due to the reverse bending load with combination of rotating bending load. Corrective actions for plant operator was recommended based on the analysis.

A Study on Velocity Distribution Around Ship Stern by Improved Power Law Flow Model (멱법칙 유동모델의 개선에 의한 선미 유동장내 속도분포 연구)

  • 김시영
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.7
    • /
    • pp.1391-1397
    • /
    • 1992
  • Improved power law flow model was suggested for the calculation of wake flow characteristics around the three dimensional ship stern in case of the formation of bilge vortex in the direction of stern. In comparison with the power law and Coles flow model, the flow velocity calculated based on this study was delayed around the boundary of inner layer and outer layer in reverse flow. More accurate results was obtained with this improved power law flow model by the velocity calculation around ship stern. Accuracy was validated with the comparison of other calculation results and experimental datas.

A Single-Stage AC/DC Converter with Low Voltage Stresses and Reduced Switching Losses

  • Kim, Kyu-Tae;Choi, Woo-Young;Kwon, Jung-Min;Kwon, Bong-Hwan
    • Journal of Power Electronics
    • /
    • v.9 no.6
    • /
    • pp.823-834
    • /
    • 2009
  • This paper proposes a high-efficiency single-stage ac/dc converter. The proposed converter features low voltage stresses and reduced switching losses. It operates at the boundary of discontinuous- and continuous-conduction modes by employing variable switching frequency control. The turn-on switching loss of the switch can be reduced by turning it on when the voltage across it is at a minimum. The voltage across the bulk capacitor is independent of the output loads and maintained within the practical range for the universal line input, so the problem of high voltage stress across the bulk capacitor is alleviated. Moreover, the voltage stress of the output diodes is clamped to the output voltage, and the output diodes are turned off at zero-current. Thus, the reverse-recovery related losses of the output diodes are eliminated. The operational principles and circuit analysis are presented. A prototype circuit was built and tested for a 150 W (50V/3A) output power. The experimental results verify the performance of the proposed converter.