• 제목/요약/키워드: Reverse Osmosis (RO)

검색결과 230건 처리시간 0.027초

역삼투막 공정에서 화학적 세정에 의한 $SiO_2$ scale 제거특성 (Characteristics of $SiO_2$ Scale Removal by Chemical Cleaning in Reverse Osmosis Membrane Process)

  • 독고석;이형집
    • 상하수도학회지
    • /
    • 제24권1호
    • /
    • pp.93-101
    • /
    • 2010
  • Reverse osmosis (RO) membranes have been widely used for desalination as well as water and wastewater treatment facilities. Cleaning process is important to maintain stable operation as well as prevention of membrane fouling. Purpose of this research is to analyze electrostatistic and chemical characteristics after cleaning of RO membrane against $SiO_2$ scale. Four RO membranes of polyamide are used and examined about effect of chemical cleaning. EDTA (ethylene diamine tetraacetic acid) and SDS (sodium dodecil sulfate) and NaOH are applied for cleaning process after operation in synthetic water. Then, cleaning was performed with chemicals such concentration as 6hr, 12hr and 24hr, respectively. As a result, transmittances of FT-IR of four membranes are compared at each cleaning concentration. Ta/Tv shows difference of chemical composition between new membrane and cleaning membrane after cleaning. Type B of RO membrane is turned out to be most vulnerable to cleaning among four membranes. In terms of zeta potential, new membrane has -16 mV to +6 mV on pH while scaled membrane has -18 mV to 2 mV. However, it changed -23mV to 0.9 mV after cleaning. In comparison with existing salt rejection of RO membranes after cleaning, the rejection of the membranes goes down 0.7% maximum. Though cleaning changes the characteristics of membrane surface, it does not greatly affect salt rejection. pH is a critical factor to flux change in PA (polyamide) membrane.

역삼투압법에 의한 양파착즙액의 휘발성 성분 변화 (Reverse osmosis causes change in volatile compounds in onion juice)

  • 심재언;전명희;이대희;김영석;이상미;최정민;장은지
    • 한국식품과학회지
    • /
    • 제51권1호
    • /
    • pp.7-11
    • /
    • 2019
  • 비가열 방식의 역삼투압법으로 제조한 양파농축액의 휘발성 성분 변화를 알아보기 위하여 양파착즙액과 역삼투압 양파농축액을 SAFE로 휘발성 성분을 추출하였고, 이를 GC-MS로 분석하였다. 양파착즙액과 양파농축액에서 각각 48종과 62종의 휘발성성분을 동정하였다, 휘발성 성분 중 sulfur-containing compounds를 19종 검출하였고. 양파의 특징적인 향기성분으로 알려진 11종은 약 1.7-1,664배로 증가하였으며, 또한 양파착즙액에서 검출되지 않았던 휘발성 성분이 양파농축액에서 14종이 검출되었다. 이는 역삼투압법을 이용한 양파 농축액이 향미성분의 변성이 적어, 양파 고유의 향미를 갖는 농축액 제조에 응용할 수 있으며, 미량의 휘발성 성분을 분석하는 전처리 방법으로 바람직한 영향을 줄 것으로 생각한다.

개발도상국 염분 제거를 위한 CDI와 RO의 전기전도도 감소 성능평가 (Evaluation of Electrical Conductivity Reduction of CDI and RO for Salt Removal in Developing Countries)

  • 김범규;양동진
    • 적정기술학회지
    • /
    • 제6권2호
    • /
    • pp.183-189
    • /
    • 2020
  • 개발도상국은 빈약한 식수 인프라로 인해 식수공급에 어려움을 겪고 있으며 식수가 공급되지 않는 지역에서는 지하수를 주된 식수원으로 이용하는 경우가 많다. 하지만 지하수의 경우 다양한 오염원에 노출되어 있고 이로 인한 문제가 발생하기도 한다. 특히 해안지역은 그 지리적 특성으로 인해 해수침투에 노출되기 쉽고 해수침투에 노출된 지역의 지하수는 일반적인 경우보다 높은 염도를 가지는 경향이 있다. 만약 염도가 높은 지하수를 지속적으로 마시게 된다면 심장 및 신장질환 등 인체에 다방면으로 치명적인 영향을 끼치는 원인이 될 수 있기에 주의가 필요하다. 본 연구에서는 해수침투가 일어난 지역에서의 탈염을 위한 기술인 CDI(Capacitive Deionization)와 역삼투의 원리를 이용한 RO(Reverse Osmosis)의 적용가능성을 탐색해보고자 하며, 염수 농도에 따른 정수성능 실험을 진행하여 탈염성능을 평가해 보고자 한다. 또한 개발도상국의 일부 지역은 전력이 원활하게 보급되지 않는 경우가 많기에 본 연구에는 정수하는데 실제 사용하는데 필요한 소비전력을 계산하여 평가에 포함하고자 한다. 이를 통해 개발도상국 해수침투지역에 적합한 탈염기술을 제안할 수 있을 것으로 기대한다.

하수방류수의 전처리 조건별 FO막의 운전성능평가 (Evaluation of FO membrane performance for each type of pre-treatment from WWTP secondary effluents)

  • 정준원;김지훈;김건엽;박준영;김형수;김형숙
    • 상하수도학회지
    • /
    • 제30권2호
    • /
    • pp.131-137
    • /
    • 2016
  • The development of alternative water resources has emerged as an effective method for solving drought of water resources due to extreme weather and increase in water consumption. Recently, in Korea, there has been active research on reverse osmosis desalination technology, wastewater reuse using forward osmosis membranes, and the forward osmosis(FO)-reverse osmosis(RO) hybrid process combining these two technologies. In this study, the basic performance of FO membranes manufactured by three domestic and international manufactures such as Microfilter Co., Ltd., Toray Chemical Korea Inc., and Hydration Technologies Inc., were investigated for wastewater reuse. In addition, as an experiment to select feed solution, the selected membranes were operated 48 consecutive hours using three secondary effluents pretreated by the UF membrane with a pore size of $0.1{\mu}m$ and auto strainer with pore sizes of $1{\mu}m$ and $100{\mu}m$ as feed solution. Although there was not much difference in the operating performance. Thus, the treated water using the $100{\mu}m$ auto strainer was selected as feed solution applied to the assessment.

정삼투-무삼투압차(△𝜋≤0) 법 역삼투 해수 담수화 및 고농도 NaCl 용액의 삼투압 근사식 (Forward Osmotic Pressure-Free (△𝜋≤0) Reverse Osmosis and Osmotic Pressure Approximation of Concentrated NaCl Solutions)

  • 장호남;최경록;정권수;박권우;김유천;서찰스;김낙종;김도현;김범수;김한민;장윤석;김남욱;김인호;김건우;이햇빛;치앙페이
    • 멤브레인
    • /
    • 제32권4호
    • /
    • pp.235-252
    • /
    • 2022
  • 무삼투압차 역삼투압(Δ𝜋= 0)은 KAIST H. N. Chang 명예교수가 2013년 발명, 2014년 미국 특허 출원, 2018년 특허 취득(US 9,950,297) 해수담수화기술. Chang 등의 RO 기술은 삼투압 조정조와 저압 역삼투압의 2 챔버로 구성. Chang 등은 소금물을 비롯한 모든 수용액은 물과 용질(소금)로 완전 분리 가능 주장. 삼투압차 조정조, 저압 역삼투압조 2 챔버로 구성됨. 고농도 용액의 삼투압은 1908년 미국화학회지 출간된 MIT G. N. Lewis식 이용. 두 번째 특허(US 10,953,3367)에서 RO가 10~12 bar 저 삼투압차 수행 가능 증명. 세 번째 특허(Korea 10-2322755, 해외 출원 중) Singularity ZERO 활용하면 기존 RO에 비해 물은 50% 추가, 막 면적은 1/3, 이론에너지는 1/5, 동일 용량의 S-ZERO 기술은 기존 RO 건설비의 50~60%로 예측됨.

해수담수화 시설의 시스템 구성에 따른 $CaCO_3$ 스케일 형성능 진단 (Evaluation of calcium carbonate scale formation on system design of seawater reverse osmosis plants)

  • 강남욱;최양훈;이혜주;이석헌;권지향
    • 상하수도학회지
    • /
    • 제24권2호
    • /
    • pp.143-155
    • /
    • 2010
  • Fouling by inorganic scales needs to be prevented to effectively operate sea water reverse osmosis(SWRO) membrane systems. The extents of inorganic scaling with different array designs including one-pass, two-pass and several hybrid designs were evaluated using seawater from southern sea near the city of Chang-Won. The used methods for evaluation were Stiff and Davis Index(S&DSI) calculation and several laboratory experiments. The formation potential of inorganic scale fouling was quite great under the examined conditions, which was confirmed by the laboratory experimental results. The inorganic scale was not avoidable fouling if any anti-scaling measures were not applied. The RO showed decreased flux under the scale formation conditions. The increases in S&DSI from 1.43 to 5 made small decreases in flux, which indicated that formation of inorganic scales had more substantial effects on RO flux than amount of inorganic scales.

탄소나노튜브가 첨가된 폴리술폰 지지체가 폴리아미드 역삼투막의 성능에 미치는 영향 (Effect of MWCNTs/PSf support layer on the performance of polyamide reverse osmosis membrane)

  • 민충식;김승현
    • 상하수도학회지
    • /
    • 제34권2호
    • /
    • pp.127-137
    • /
    • 2020
  • In this study, a MWCNT(multi-wall carbon nanotube) was added to polysulfone(PSf) support layer to improve flux of TFC(thin film composite) RO(reverse osmosis) membrane. Two different kinds of MWCNT were used. Surfaces of some MWCNTs were modified hydrophilically through acid treatment, while those of other MWCNTs were modified through heat treatment to maintain their hydrophobicity. MWCNT/PSf support layer was prepared by adding PSf to the NMP mixed solvent containing 0.1 wt% MWCNTs using a phase inversion method. The surface porosity of the MWCNT/PSf support increased by 42~46% while its surface pore size being maintained. The TFC RO membrane made of MWCNT/PSf support layer showed a 20% flux increase while its salt rejection characteristics is sustained. In addition, the MWCNT/PSf support layer has better mechanical stability than the PSf support layer, there resulting in an increased resistance of flux reduction due to physical pressure.

Pretreatment in Reverse Osmosis Seawater Desalination: A Short Review

  • Valavala, Ramesh;Sohn, Jin-Sik;Han, Ji-Hee;Her, Nam-Guk;Yoon, Yeo-Min
    • Environmental Engineering Research
    • /
    • 제16권4호
    • /
    • pp.205-212
    • /
    • 2011
  • Reverse osmosis (RO) technology has developed over the past 40 years to control a 44% market share in the world desalting production capacity and an 80% share in the total number of desalination plants installed worldwide. The application of conventional and low-pressure membrane pretreatment processes to seawater RO (SWRO) desalination has undergone accelerated development over the past decade. Reliable pretreatment techniques are required for the successful operation of SWRO processes, since a major issue is membrane fouling associated with particulate matter/colloids, organic/inorganic compounds, and biological growth. While conventional pretreatment processes such as coagulation and granular media filtration have been widely used for SWRO, there has been an increased tendency toward the use of ultrafiltration/microfiltration (UF/MF) instead of conventional treatment techniques. The literature shows that both the conventional and the UF/MF membrane pretreatment processes have different advantages and disadvantages. This review suggests that, depending on the feed water quality conditions, the suitable integration of multiple pretreatment processes may be considered valid since this would utilize the benefits of each separate pretreatment.

역삼투막을 이용한 음식폐기물 액비의 농축 (Accumulation of Food Wastes Liquid Fertilizer using Reverse Osmosis Membrane System)

  • 차기철;황명구;이명규;태민호
    • 한국물환경학회지
    • /
    • 제18권2호
    • /
    • pp.159-168
    • /
    • 2002
  • A lab-scale Reverse Osmosis(RO) membrane reactor was installed to investigate the membrane permeability, characteristics of membrane fouling at each conditions, and performance of elimination at different trans-membrane pressure(TMP) in the liquid fertilizer accumulated system. Experimental setup was divided to three different TMP conditions. As a result of experiment, permeability of RO membrane was proportional to the increase of TMP and temperature. After experiment was completed, two types chemical cleaning(remove the organic foulant and inorganic foulant) was done, and recover rate of permeability was each 99.8, 99.7 and 99.7%, respectively. From this experimental data, membrane fouling could be determined that the most of it was recoverable in this system, and major reason of fouling was concentration polarization. Elimination rate of solute substance in the liquid fertilizer indicated very stable(above 99%), except ammonia nitrogen, and the most stable elimination rate was investigated at the highest TMP condition (Run 3).

RO/NF막 공정을 이용한 BTEX 물질의 제어 특성 평가 (Removal Mechanisms of BTEX Compounds by RO/NF Membrane Processes)

  • 장혜원;박찬혁;홍승관;윤여민;정진영;정윤철
    • 한국물환경학회지
    • /
    • 제22권5호
    • /
    • pp.926-932
    • /
    • 2006
  • A series of bench-scale membrane filtration experiments were performed to systematically investigate the removal mechanisms of reverse osmosis (RO) and nanofiltration (NF) membranes for BTEX (benzene, toluene, ethylene, xylene), trichloroethylene (TCE) and tetrachloroethylene (PCE). The molecular weight of these organic compounds ranged from 78 to 166 dalton. The rejection of organic compounds by RO/NF membranes varied significantly from 59.6 to 99.2% depending on solute and membrane types. Specifically, experimental results demonstrated that the removal efficiency of RO/NF membranes increased as solute molecular characteristics such as W/L (molecular width/length) ${\times}$ $M_W$ (molecular weight) and octanol-water partition coefficient increased. This observation suggested that the rejection of small organic compounds by RO/NF membranes was determined by the combined effect of physical (molecular size and shape) and chemical (hydrophobicity) properties.