• 제목/요약/키워드: Return flowrate

검색결과 4건 처리시간 0.016초

공동주택 온수난방 시스템의 적정 열공급을 위한 배관망 시뮬레이션 (Simulation of Pipe Network for Optimum Heat Supply in the Hot Water Heating System of Apartment House)

  • 김주용;민만기;최영돈
    • 설비공학논문집
    • /
    • 제5권3호
    • /
    • pp.157-168
    • /
    • 1993
  • Pipe network of hot water heat supply system in an apartment house was analyzed. Flowrate and supply heat capacity of each household in which constant flowrate balancing valve is installed in a single zone system were calculated and the results were investigated. In the existing piping system, the non-uniformity of heat supply with floors due to the static pressure and temperature difference between supply main and return main can not be avoided and this tendency get intense with the increase of the height of building. The non-uniformity of heat supply can be prevented by the installation of balancing valve at each household, however if the performance of supply pump is not sufficient to overcome the energy loss due to the installation of balancing valve for constant flow rate or if the selection of the valve capacity is not adequate, the valves will may lose their controllability.

  • PDF

LSTM기반의 자료 변동성을 고려한 하천수 회귀수량 예측 알고리즘 개발연구 (Development of Return flow rate Prediction Algorithm with Data Variation based on LSTM)

  • 이승연;유형주;이승오
    • 한국방재안전학회논문집
    • /
    • 제15권2호
    • /
    • pp.45-56
    • /
    • 2022
  • 가뭄 및 갈수시에 용수부족 현상이 발생하나 회귀수량을 고려한 대응이나 대책 마련이 진행되지 않고 있다. 이에 본 연구에서 자료기반의 기계학습 모형(LSTM)을 통해 회귀수량 중 하수종말처리장의 방류량을 예측하였다. 입력자료로 방류량, 유입량, 강수량, 수위를 사용하였고 예측 결과의 정확도를 개선하기 위하여 추가적으로 입력변수의 변동성 분포를 고려하였다. 방류량 자료의 변동성을 확인하기 위해서 관측값과 분포 사이의 잔차를 복합삼각함수 형태로 가정하여 이론적인 확률분포와 함께 방류량 최적의 분포 형태로 나타내었다. 변동성 분포를 고려한 입력자료를 이용한 결과와 그렇지 않는 결과를 비교한 결과, 오차정도가 감소함을 보였으며 이는 변동성 분포가 계절성을 상대적으로 잘 재현하였기 때문이라 판단된다. 따라서 본 연구에서 구축한 하수종말장처리장의 방류량 예측 모형을 활용할 경우 보다 정확한 회귀수량 예측이 가능하여 효율적인 하천수 관리 체계를 수립하는데 기초자료로 활용될 수 있을 것으로 기대된다.

바닥복사 난방시스템의 실내 열환경 특성에 대한 실험적 연구 (Experimental Study on the Indoor Thermal Characteristics for Floor Radiant Heating System)

  • 송재엽;안병천
    • 한국지열·수열에너지학회논문집
    • /
    • 제17권3호
    • /
    • pp.1-12
    • /
    • 2021
  • In this study, the effects of various operational conditions for floor radiant heating system were researched by experiments. Hot water supply set temperature, indoor air set temperature and supply water flowrate were considered as operational conditions. The control method for this system is On-Off control of automatic thermostatic valve. The purpose of this study is to evaluate indoor thermal control characteristics and energy performance, respectively. As a result, if lower supply water temperature is applied, the supply and return temperature difference is reduced and energy consumption of heat supply is also reduced.

도시지역의 최적 배수관망 설계를 위한 Risk Safety Factor 관계의 설정 (Derivation of the Risk-Safety Factor Relation for Optimal Storm Sewer Design in Urban Area)

  • 김문모;이원환;조원철
    • 대한토목학회논문집
    • /
    • 제12권4호
    • /
    • pp.129-134
    • /
    • 1992
  • 본 논문은 도시유역의 최적 배수관망설계를 위한 위험도-안전도계수 관계를 설정하는 것이다. 배수관망의 신뢰도 분석을 위하여는 하수관의 용량과 하중을 결정하는 식을 구성하는 여러가지 매개변수들의 불확실성이 고려되어야 하며, 이에 따른 위험도를 결정하게 된다. 본 연구에서는 신뢰도 분석기법을 유역면적 $381,000m^2$인 성산 유수지 유역에 적용하였다. 하수관망의 용량을 결정하는 식으로는 Darcy-Weisbach식을, 하중을 결정하는 식으로는 합리식을 사용하였으며, 하수관의 용량과 설계유량과의 비로 나타나는 안전도계수를 구하여 이를 하수관망의 위험도와 상관시켰다. 이에 따라 재현기간별 위험도-안전도계수를 얻었으며, 이는 배수관망의 최적설계에 이용될 수 있다.

  • PDF