• Title/Summary/Keyword: Return Mode

Search Result 160, Processing Time 0.071 seconds

Effects of the Irradiated Current Mode PWM Controller of DC/DC Power Converter (DC/DC 전력 컨버터의 전류모드 PWM 제어기의 방사선 영향)

  • Lho, Young-Hwan;Hwang, Eui-Sung;Lho, Kyeoung-Su;Phouphanonh, Phouphanonh;Khamphoungeun, Khamphoungeun;Han, Chang-Won
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.685-692
    • /
    • 2011
  • DC/DC switching power converters produce DC output voltages from different DC input sources. The converters can be used in regenerative braking of DC motors to return energy back in the supply, resulting in energy savings for the systems containing frequent stops. The current mode DC/DC converter is composed of a PWM (pulse width modulation) controller, a MOSFET, and inductor, etc. Pulse width modulation is applied to control and regulate the total output voltage. It is shown that the variation of threshold voltage at MOSFET and the offset voltage increase caused by radiation effects make the PWM pulse unstable. In the PWM operation, the missing pulses, the changes in pulse width, and a change in the period of the output waveform are studied by simulation program with integrated circuit emphasis (SPICE) and experiments.

  • PDF

A 0.13-μm CMOS RF Tx/Rx Switch for Wideband Applications

  • Kim, Jeong-Yeon;Kim, Chang-Wan
    • Journal of electromagnetic engineering and science
    • /
    • v.8 no.3
    • /
    • pp.96-99
    • /
    • 2008
  • This paper describes a $0.13-{\mu}m$ CMOS RF switch for $3{\sim}5$ GHz UWB band(mode 1). It can improve isolation characteristics between ports by using deep n-well RF devices while their source and body terminals are separated. From the measurement results, the proposed T/R switch is comparative to the on-wafer probing measurement results of the series-shunt T/R switches. When the proposed T/R switch operates as Tx mode, measured insertion loss from Tx to output port is less than 1.5 dB and isolation between Tx and Rx is more than 27 dB for $3{\sim}5$ GHz. Return loss for the Tx port is more than -10 dB and input P1dB is +10 dBm.

A Four-Channel Laser Array with Four 10 Gbps Monolithic EAMs Each Integrated with a DBR Laser

  • Sim, Jae-Sik;Kim, Sung-Bock;Kwon, Yong-Hwan;Baek, Yong-Soon;Ryu, Sang-Wan
    • ETRI Journal
    • /
    • v.28 no.4
    • /
    • pp.533-536
    • /
    • 2006
  • A distributed Bragg reflector (DBR) laser and a high speed electroabsorption modulator (EAM) are integrated on the basis of the selective area growth technique. The typical threshold current is 4 to 6 mA, and the side mode suppression ratio is over 40 dB with single mode operation at 1550 nm. The DBR laser exhibits 2.5 to 3.3 mW fiber output power at a laser gain current of 100 mA, and a modulator bias voltage of 0 V. The 3 dB bandwidth is 13 GHz. A 10 Gbps non-return to zero operation with 12 dB extinction ratio is obtained. A four-channel laser array with 100 GHz wavelength spacing was fabricated and its operation at the designed wavelength was confirmed.

  • PDF

Design of multimode E-plane corugated monopulse horn for linear phased array feeder (선형 위상배열 급전기에서 저부엽 모노펄스 패턴을 얻기 위한 다중모드 E-면 주름혼의 설계)

  • 김찬홍;이용희;홍동희
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.33A no.11
    • /
    • pp.52-59
    • /
    • 1996
  • This paper presents a monopulse feed structure with low sidelobe monopulse pattern, which consists of a E-plane corrugated horn and a unfiorm pick-up aperture power divider. Tfhe design methods and epxerimental resutls of the E-plane corrugated feeder are described. Modified hybrid mode analysis and GSM (generalized scattering matrix) methods are introduced to design the E-plane corrugated feed horns. The 24-port corrugated feeder is designed using modified hybrid mode analysis initially and verified using GSM methods. Measurement results show that this feeder has low return loss and sidelobe level at sum and difference channel, respectively.

  • PDF

Design of Nx1 Modified Rectangular Loop Array Antenna for Radar Application (레이더용 Nxl 변형 사각 루프 배열 안테나 설계)

  • Jang, Jae-Su;Ko, Jin-Hyun;Ha, Jae-Kwon;Kim, Tae-Hyun;Park, Dong-Chul;Kim, Chan-Hong
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.9 no.1 s.24
    • /
    • pp.144-151
    • /
    • 2006
  • A rectangular loop antenna for S-band radar is proposed. The proposed loop antenna is the modified type of folded monopole antenna. The feeding line is coplanar stripline with $180^{\circ}$ phase difference for operating in odd mode. The proposed antenna showed return loss of -15.57dB at the center frequency and bandwidth of about 790MHz (> 25%) under the condition of VSWR < 2. The gains of single, 1x2, and 1x4 array loop antennas are 4.3, 7.0, and 10.2dBi, respectively.

Modulated Carrier Control for Interleaved Continuous Conduction Mode(CCM) Boost Power Factor Correction Converter

  • Kim, Hye-jin;Choi, Kyu-sik;Cho, B.H.;Choi, Hang-seok
    • Proceedings of the KIPE Conference
    • /
    • 2012.07a
    • /
    • pp.195-196
    • /
    • 2012
  • In recent years, in an effort to improve the efficiency and the power density of the front-end power factor correction(PFC), the interleaving of multiple converter is employed. The conventional interleaved continuous conduction mode(CCM) boost PFC converter requires input and output voltage sensing and three current sensing to obtain current balancing between modules. In this paper, the interleaved CCM PFC converter based on modulated carrier control is proposed. With the proposed method, two phase interleaved PFC can be realized simply without line voltage sensing resistor and can achieve current balancing without additional current sensing resistor on common return path. The simulation studies are carried out to verify the effectiveness of the proposed control scheme.

  • PDF

Design of 250-Mb/s Low-Power Fiber Optic Transmitter and Receiver ICs for POF Applications

  • Park, Kang-Yeob;Oh, Won-Seok;Choi, Jong-Chan;Choi, Woo-Young
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.11 no.3
    • /
    • pp.221-228
    • /
    • 2011
  • This paper describes 250-Mb/s fiber optic transmitter and receiver ICs for plastic optical fiber applications using a$ 0.18-{\mu}m$ CMOS technology. Simple signal and light detection schemes are introduced for power reduction in sleep mode. The transmitter converts non-return-to-zero digital data into 650-nm visible-red light signal and the receiver recovers the digital data from the incident light signal through up to 50-m plastic optical fiber. The transmitter and receiver ICs occupy only 0.62 $mm^2$ of area including electrostatic discharge protection diodes and bonding pads. The transmitter IC consumes 23 mA with 20 mA of LED driving currents, and the receiver IC consumes 16 mA with 4 mA of output driving currents at 250 Mb/s of data rate from a 3.3-V supply in active mode. In sleep mode, the transmitter and receiver ICs consume only 25 ${\mu}A$ and 40 ${\mu}A$, respectively.

A Design on the Four-Horn Triple-Mode Type Monopulse Feeder at X-Band (X-대역 4혼 삼중 모드 모노펄스 급전기 설계)

  • Kim, Chan-Hong;Kim, Seung-Gak
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.21 no.5
    • /
    • pp.528-536
    • /
    • 2010
  • A monopulse feeder gives the most important impact upon the radiation pattern characteristics of a multi-function radar or a tracking radar which uses the space feed. It is described that the triple-mode type monopulse feeder which possesses the optimum aperture illumination for three monopulse channels is designed and measured in this paper. The measured results show that the designed feeder has not only the characteristics of the optimum aperture illimination in each channel and also very low return loss over the 10 % of fractional bandwidth at X-band. This means that the feeder provides the antenna system with low sidelobe level and high monopulse slope characteristics.

The evaluation of T-P removal and dewaterability under the operation change in KIDEA process (-기술정보- 연속유입 KIDEA에서 공정변화에 따른 인제거 및 탈수 함수율 상관관계)

  • Yeon, seung jun;Her, hee seung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.2
    • /
    • pp.179-182
    • /
    • 2008
  • The KIDEA process, occurred in single reactor, is operated by three consequential steps, i.e., aerobic, settling, and discharge while introducing wastewater into the bottom of reactor continuously. It could accomplish biological oxidation (BOD), nitrification, denitrification (T-N), phosphate removal (T-P), and solid separation (SS) through the operational mode mentioned. Especially, this system has removed the T-P by wasting certain amount of sludge at the end of aeration phase during 5~10 minutes and not returned the activated sludge into the reactor, that is, no RAS (Return Activated Sludge). All running mode and instrumentation were controlled by the PLC equipment automatically. In this study, therefore, we have evaluated T-P removal efficiency and moisture content (MC) performance under the different excess sludge wasting mode. T-P track study and MC with TS concentration were analyzed during aerobic and settling phase. It has revealed that there was no significant difference of released T-P concentration between the first case which waste the sludge at the end of aerobic phase (0.2mg/L) and the second case which waste the sludge at 40 min of settling phase (0.25mg/L). Also, dewatering duration and MC have decreased 1.7% when TS concentration was increased from 0.31% to 0.5% during aerobic condition. Hence, it has concluded the system performance was less influenced by the operation time change of PLC program.

A Studies for Sequential Mode Change Control Algorithm of the Parallel Dual Converter of Using Thyristor for Supplying the Urban Railway DC Power (도시철도의 직류전력 공급을 위한 사이리스터를 사용한 병렬 듀얼 컨버터의 순차적 모드 전환 제어 알고리즘에 대한 연구)

  • Han, Sung-Woo;Kim, Sung-An;Cho, Yun-Hyun;Byun, Gi-Sig
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.3
    • /
    • pp.511-519
    • /
    • 2016
  • This paper is proposed control algorithm for the using thyristor of the parallel dual converter for Urban railway power supply in order to return the regenerative power generated by regenerative braking in urban railway train. Conventional control algorithm of Thyristor dual converter for urban railway power supply has voltage variation within a control range of hysteresis band. The purposed control algorithm of the parallel thyristor dual converter is to maintain a constant voltage without voltage variation in accordance with variable load through the Sequential mode change. And the control algorithm need calculating optimum initial firing angle to consider magnitude of the load current slope. For this purpose, Proposed algorithm for sequential conversion mode of the dual converter was verified by applying for the simulation.