• 제목/요약/키워드: Retention index

검색결과 213건 처리시간 0.025초

보류 시스템이 Floc 특성과 보류에 미치는 영향 (Effect of Retention System on the Characteristics of Floc and Retention)

  • 김용식;원종명
    • 펄프종이기술
    • /
    • 제33권3호
    • /
    • pp.9-17
    • /
    • 2001
  • The floc characteristics of base paper stock for coating by the retention aid system consisting of polyacrylamide (high molecular weight low charge density, HMLC) and PEI without and with anionic inorganic oxide (IO) were investigated under various shear conditions of MDDA (modified dynamic drainage analyzer). The floc size was increased with cationic electrolytes dosage whatever inorganic oxide is applied or not. The effect of inorganic oxide on the floc size showed the different result between PAM and PEI. The smaller floc was obtained by PAM without inorganic oxide, but larger floc was obtained by PAM with inorganic oxide. However, the effect of shear force was not observed. Floc formation index was decreased by the addition of cationic electrolytes with or without inorganic oxide. Floc formation index had better correlation format formation index than floc size. The relationships between wet web permeability and mat air permeability showed the significant linear correlation ($R^2$=0.97~0.98) for HML PAM and PEI. Floc formation index gave more useful information than the retention measurement when the performance of retention aids is evaluated at the laboratory before applying at the paper mill.

  • PDF

Interrelation of Retention Factor of Amino-Acids by QSPR and Linear Regression

  • Lee, Seung-Ki;Polyakova, Yulia;Row, Kyung-Ho
    • Bulletin of the Korean Chemical Society
    • /
    • 제24권12호
    • /
    • pp.1757-1762
    • /
    • 2003
  • The interrelation between retention factors of several L-amino acids and their physico-chemical and structural properties can be determined in chromatographic research. In this paper we describe a predictor for retention factors with various properties of the L-amino acids. Eighteen L-amino acids are included in this study, and retention factors are measured experimentally by RP-HPLC. Binding energy ($E_b$), hydrophobicity (log P), molecular refractivity (MR), polarizability (${\alpha}$), total energy ($E_t$), water solubility (log S), connectivity index (${\chi}$) of different orders and Wiener index (w) are theoretically calculated. Relationships between these properties and retention factors are established, and their predictive and interpretive ability are evaluated. The equation of the relationship between retention factors and various descriptors of L-amino acids is suggested as linear and multiple linear form, and the correlation coefficients estimated are relatively higher than 0.90.

Identification of Coffee Fragrances Using Needle Trap Device-Gas Chromatograph/Mass Spectrometry (NTD-GC/MS)

  • Eom, In-Yong;Jung, Min-Ji
    • Bulletin of the Korean Chemical Society
    • /
    • 제34권6호
    • /
    • pp.1703-1707
    • /
    • 2013
  • A fast and simple sampling and sample preparation device, (NTD) has been developed and applied to sample and analyze volatile components from ground coffee beans. Coffee fragrances and other volatile organic compounds (VOCs) were sampled by the NTD and then analyzed by gas chromatograph-mass spectrometry (GC/MS). Divinylbenzene (DVB) particles (80/100 mesh size) were the sorbent bed of the NTD. More than 150 volatile components were first identified based on the database of the mass library and then finally 30 fragrances including caffeine were further confirmed by comparing experimental retention indices (i.e. Kovat index) with literature retention indices. Total sampling time was 10 minutes and no extra solvent extraction and/or reconstitution step need. Straight n-alkanes (C6-C20) were used as retention index probes for the calculation of experimental retention indices. In addition, this report suggests that an empty needle can be an alternative platform for analyzing polymers by pyrolysis-GC/MS.

고분자 코팅 처리된 마이크로 펄프가 종이 물성에 미치는 영향 (Effects of Polymer Coated Micro pulp on Paper Properties)

  • 손동진;김학상;김봉용
    • 펄프종이기술
    • /
    • 제42권1호
    • /
    • pp.48-53
    • /
    • 2010
  • Commercial micro pulps(Arbocel) were coated with three kinds of polymers using spray method. These coated micro pulps were used to papermaking additives to evaluate retention, drainage and physical properties of paper. The retention and drainage were improved with addition of polymer coated micro pulp. The bulk index of paper was also increased, but tensile and tear strength were decreased slightly, probably due to weakening of internal bonding. These results showed that the use of polymer coated micro pulp was an effective method to improve retention, drainage and bulk index of paper.

치과위생사의 정서, 감정노동, 행복지수와 재직의도와의 융합적 관계 (The Convergence Relationship on Emotion, Emotional Labor, Happiness Index, and Retention Intention in Dental Hygienists)

  • 원영순;박아름
    • 융합정보논문지
    • /
    • 제9권7호
    • /
    • pp.135-144
    • /
    • 2019
  • 본 연구는 치과위생사의 정서, 감정노동, 행복지수와 재직의도의 관계를 파악하고 영향을 미치는 요인을 분석함으로써 치과위생사의 재직의도를 향상시킬 수 있는 방안을 마련하기 위한 기초자료로 활용하고자 실시하였다. 자료 수집은 전북 4개 지역에서 근무하고 있는 치과위생사 295명을 대상으로 설문조사하였다. 자료 분석은 SPSS version 19.0을 사용하여 단변량 분석과 3단계에 걸친 위계적 회귀분석을 실시하였다. 그 결과, 기혼인 경우(p<.001), 긍정적인 정서일수록(p<.001), 감정표현의 빈도가 낮을수록(p=.010), 삶의 만족 행복지수(p<.001)와 심리적 행복지수(p=.012)가 높을수록 치과 위생사의 재직의도가 높은 결과를 보였다. 이에 치과위생사의 정서, 감정노동, 행복지수는 재직의도를 증가시키기 위한 중요 관련요인으로 인식되어야 하며 개인적 차원이 아닌 조직적 차원으로 개선해 나갈 방안을 모색해야 할 것으로 본다.

천궁(Cnidium officinale)의 향기성분 (Studies on the volatile compounds of Cnidium officinale)

  • 이재곤;권영주;장희진;김옥찬;박준영
    • 한국연초학회지
    • /
    • 제16권1호
    • /
    • pp.20-25
    • /
    • 1994
  • The volatile components were extracted from root of Cnidium officinale M. by SDE(Simultaneous steam distillation and extraction) apparatus and analyzed by GC/M.5 and GC retention index matching. The experimental results revealed the presence of over 22 volatile components. Major components were cnidilide (35.1%), neocnidilids (13.4%), ligustilide (23.2%). The essential oils were separated by silica gel column chromatography(Merck 70-230mesh), and 4 fractions among 12 fractions separated had a, good aroma character.

  • PDF

여러 가지 보류시스템에서 탄산칼슘의 보류와 종이의 기계적·광학적 특성의 비교 (Comparison of Retention of Calcium Carbonate and Mechanical and Optical Properties of Sheets in Various Retention System)

  • 백기현;안병준;손상돈
    • 공업화학
    • /
    • 제7권2호
    • /
    • pp.315-320
    • /
    • 1996
  • 본 실험에서는 보류향상제의 첨가량과 중질 탄산칼슘 첨가량에 따른 탄산칼슘 보류량(회분함량)을 조사하였으며, 동일 회분량에서 종이의 기계적 광학적 특성을 비교하였다. 각 보류시스템 모두 보류향상제 첨가량을 증가시키면 중질 탄산칼슘(입자평균직경 $3.2{\mu}m$) 보류, 즉 종이의 회분량은 증가한다. 이 경우 보류향상제와 중질 탄산칼슘 첨가량을 조절하여 이미 예정된 회분량이 함유된 종이를 초지할 수 있다. 종이의 인장지수, 파열지수, 인열지수 및 내부결합강도는 종이의 회분량이 증가됨에 따라 직선적으로 감소한다. 특히 동일 회분량에서 비교하면, 콤포질 시스템에 의한 종이에서 제반 강도가 높고, 듀알 폴리머 시스템에서는 강도가 낮다. 불투명도는 회분량 증가에 따라 함께 증가하며, 하이드로콜 시스템에서 가장 높고 역시 듀알 폴리머에서 가장 낮다. 동일 불투명도에서 종이의 강도는 콤포질, 하이드로콜, 듀알 폴리머 시스템 순으로 감소한다. 그러나 보류향상제의 우열을 판단하기 위해서는 충전제의 보류량과 종이의 강도 이외에도 적정 생산조건 및 적정 공정조건과 같은 여러 가지 다른 요인들도 고려되어야 한다.

  • PDF

Comparison of retention characteristics of Essix and Hawley retainers

  • Demir, Abdullah;Babacan, Hasan;Nalcaci, Ruhi;Topcuoglu, Tolga
    • 대한치과교정학회지
    • /
    • 제42권5호
    • /
    • pp.255-262
    • /
    • 2012
  • Objective: We aimed to compare the retention characteristics of Essix and Hawley retainers. Methods: Adolescents undergoing fixed appliance treatment at 2 centers were recruited for this study. Twenty-two patients (16 women and 6 men) wore Essix retainers (Essix group) while 20 (14 women and 6 men) wore Hawley retainers (Hawley group). The mean retention time was 1 year, and the mean follow-up recall time for both groups was 2 years. Two qualified dental examiners evaluated the blind patient data. Maxillary and mandibular dental casts and lateral cephalograms were analyzed at 4 stages: pretreatment (T1), post-treatment (T2), post-retention (T3), and follow-up (T4). Results: The results revealed that Essix appliances were more efficient in retaining the anterior teeth in the mandible during a 1-year retention period. The irregularity index increased in both arches in both groups after a 2-year post-retention period. The mandibular arch lengths increased during treatment and tended to return to their original value after retention in both groups; however, these changes were statistically significant only in the Hawley group. Cephalometric variables did not show any significant differences. Conclusions: The retention characteristics of both Essix and Hawley retainers are similar.

Studies on The Elution Behavior of Ni(II)-${\alpha}$-isonitroso-${\beta}$-diketone Imine Chelates in Reversed-Phase Liquid Chromatography

  • Lee, Won;Kim, In-Whan;Kim, Mi-Kyoung;Kim, Yong-Jun;Jung, Hae-Rim;No, Kyoung-Tai;Kim, Su-Yeon
    • 분석과학
    • /
    • 제8권4호
    • /
    • pp.519-527
    • /
    • 1995
  • The retention mechanism of Ni(II)-${\alpha}$-isonitroso-${\beta}$-diketone imine chelates in reversed-phase HPLC has been studied by examining the effect of temperature, mobile phase composition in acetonitrile-water mixture, and molecular structure on retention. The empirical retention equation was investigated to evaluate the properties of S (hydrophilic index). The value of the S index of the Ni(II) chelates decrease with the increasing column temperature and a linear relationship between S and log $k{_w}^{\prime}$ has been found. The results showed that the S index is influenced by the interaction between Ni(II) chelates and mobile phase. Molecular properties, van der Waals molar volume, polarizability and dipole moment, of the Ni(II) chelates were calculated by Cerius 2 program and the calculations were performed at Universal Force Field (UFF) model. The S value and log $k{_w}^{\prime}$ increase with decreasing the dipole moment of Ni(II) chelates.

  • PDF

선천성 담도폐쇄증에서 $^{99m}Tc$ DISIDA 신티그라피의 진단정확성 (Diagnostic Accuracy of $^{99m}Tc$-DISIDA Scintigraphy in Biliary Atresia)

  • 현인영;이동수;이경한;김종호;정준기;서정기;이명철;고창순
    • 대한핵의학회지
    • /
    • 제28권3호
    • /
    • pp.357-363
    • /
    • 1994
  • 1990년 1월부터 1992년 12월까지 서울대학교병원 소아과 및 소아외과에 황달을 주소로 입원하여 원인이 규명되었던 70명의 환아들에서 $^{99m}Tc$-DISIDA 신티그라피와 초음파검사를 실시하여 다음과 같은 성적을 얻었다. 1) 선천성 담도폐쇄증 30명 전예에서 소장방사능이 관찰되지 않았고 신생아간염 40명 중 31예에서 소장 방사능이 관찰되어 소장방사능의 유무에 따른 선천성 담도폐쇄증의 진단은 예민도 100% 특이도 78%, 정확도는 87%이었다. 2) 소장방사능이 관찰되지 않았던 환아에서 간정체 지표는 선천성 담토폐쇄증 16예가 $1.5{\pm}0.6$으로 신생아간염 7예의 $1.2{\pm}0.2$보다 높았고(p<0.05), 신생아간염의 간정체지표의 2표준편차 상한값인 1.5보다 높은 간정체지표를 보인 경우는 7예로 모두 선천성 담도폐쇄증이었다. 그러나 간정체지표가 1.5 이하인 16명중 9예는 선천성 담도폐쇄증, 7예는 신생아간염으로 이들에서는 간정체지표로 구별되지 않았다. 3) 간기능장애를 나타내는 요소를 분석하였을 때 간섭취도는 선천성 담도폐쇄증과 신생아간염에서 유의한 차이가 없었다. 연령과 간섭취지표는 일정한 상관관계가 없었고 총 빌리루빈치와 간섭취지표는 간섭취도가 정상인 환아의 총빌리루빈치가 상대적으로 낮다는 소견 이외에는 일정한 상관관계가 없었다. 신생아간염에서 소장방사능이 보이는 31예의 연령이 $2.1{\pm}0.7$ 개월로 보이지 않는 9예의 연령평균 $1.7{\pm}0.5$개월 보다 많았다(P<0.01). 4) 간섭취지표와 간정체지표와의 관계는, 간섭취지표가 높을 때 즉 간기능 저하가 심할 때 간정체지표가 높으면 즉 간섭취에이은 간정체가 일정이상 수준이면 신생아간염보다 선천성 담도폐쇄증일 가능성이 높았다. 이상의 결과로 연령이 증가하면 선천성 담도폐쇄증환아의 간기능이상은 진행하지만 신생아간염환아의 간기능장애의 정도는 연령과 무관하여, 간섭취지표로 기능을 평가하고 간정체지표로 판독하면 선천성 담도폐쇄증을 감별할 수 있다고 생각하였다. 그러나 간기능저하가 가볍고 간정체지표가 좋지 않을 때에는 역시 구별되지 않아 다른 검사결과를 참조한 임상판단에 의존하여야 할 것이며 수술적 간담도 조영술의 대상 예로 삼아야 한다고 생각하였다. 이 연구의 결과를 통하여 신생아에서 발생하는 황달의 원인을 규명하는데, $^{99m}Tc$-DISIDA 신티그라피가 유용한 검사법이며, 소장방사능이 관찰되지 않는 경우에는 간정체지표와 간섭취지표와의 관계를 고려하여 간섭취지표보다 간정체지표가 상대적으로 좋을 경우 선천성 담도폐쇄증의 가능성이 높아 감별에 도움되는 소견으로 사용할 수 있을 것으로 생각하였다.

  • PDF