• Title/Summary/Keyword: Retention force

Search Result 169, Processing Time 0.028 seconds

The implant retained overdenture by Locator attachments on the edentulous mandible using Parallel guide KIT® : a case report (하악 무치악 환자에서 Parallel guide KIT®를 이용한 임플란트 식립 및 Locator 어태치먼트를 이용한 임플란트 피개의치 수복증례)

  • Kim, Hyeran;Kim, Jun-Yup;Yang, Hong-Seo;Park, Sang-Won;Lim, Hyun-Pil;Yun, Kwi-Dug;Park, Chan;Shin, Jin-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.33 no.1
    • /
    • pp.55-62
    • /
    • 2017
  • Overdenture using dental implants could improve the problems of conventional complete denture function which are pain during mastication, insufficient retention and stability. Locator attachment used widely for implant-retained overdenture has advantages that it needs the smallest vertical space and also its nylon male cap allows personalized retention for each case. However its retention force decreases rapidly with function rather than the bar and ball attachment. So, implant fixture should be positioned as parallel as possible.

Neutral zone approach for rehabilitation of severely atrophic maxillary and mandibular ridges: A case report (치조제 흡수가 심한 환자에서 중립대를 이용한 총의치 수복 증례)

  • Lee, Ja-Youn;Choi, Sun-Young;Lee, Ji-Hyoun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.4
    • /
    • pp.407-412
    • /
    • 2016
  • The neutral zone technique is an alternative approach for the construction of complete dentures on highly atrophic ridges with history of denture instability. This technique achieves two objectives. First, the teeth will not interfere with the normal muscle function, and second, the force exerted by the musculature against the denture is more favorable for stability and retention. In this case of a 78-years-old female patient with severely atrophic ridges who had been using unstable complete dentures, the neutral zone impression technique was used to increase the stability and the retention of dentures. The neutral zone for both arch was located with modeling compound. After the arrangement of artificial teeth within the neutral zone, the external impression was taken to determine the tissue surface. The final dentures showed enhanced stability and retention and the patient was satisfied with the new dentures with respect to functional and esthetic aspects.

Treatment and retention of relapsed anterior open-bite with low tongue posture and tongue-tie: A 10-year follow-up

  • Seo, Yu-Jin;Kim, Su-Jung;Munkhshur, Janchivdorj;Chung, Kyu-Rhim;Ngan, Peter;Kim, Seong-Hun
    • The korean journal of orthodontics
    • /
    • v.44 no.4
    • /
    • pp.203-216
    • /
    • 2014
  • The purpose of the current report is to present 6-year long-term stability and 10-year follow-up data for an adult patient who was treated with a tongue elevator for relapsed anterior open-bite. The 19-year-old male patient presented with the chief complaint of difficulty in chewing his food. Collectively, clinical and radiographic examinations revealed an anterior open-bite, low tongue posture, and tongue-tie. The patient opted for orthodontic treatment alone, without any surgical procedure. A lingual frenectomy was recommended to avoid the risk of relapse, but the patient declined because he was not experiencing tongue discomfort. Initial treatment of the anterior open-bite with molar intrusion and tongue exercises was successful, but relapse occurred during the retention period. A tongue elevator was used for retreatment, because the approach was minimally invasive and suited the patient's requirements regarding discomfort, cost, and time. The appliance changed the tongue posture and generated an altered tongue force, which ultimately resulted in intrusive dentoalveolar effects, and a subsequent counterclockwise rotation of the mandible. The results showed long-term stability and were maintained for six years through continual use of the tongue elevator. The results of this case indicated that a tongue elevator could be used not only as an alternative treatment for open-bite, but also as an active retainer.

An investigation into the effect of denture adhesives on incisal bite force of complete denture wearers using pressure transducers - a clinical study

  • Kalra, Pawan;Nadiger, Ramesh;Shah, Farhan Khalid
    • The Journal of Advanced Prosthodontics
    • /
    • v.4 no.2
    • /
    • pp.97-102
    • /
    • 2012
  • Study was conducted to determine and assess the effect of different type of denture adhesives on the incisal bite force of complete denture wearers until the dislodgement of upper denture, using pressure transducer. MATERIALS AND METHODS. 30 patients out of 100 were included in the study. Based on the Kapur's method of scoring denture retention and stability, these patients were divided into 3 groups-Group A - Clinically good dentures; Group B - Clinically fair dentures; and Group C - Clinically poor dentures. A custom made occlusal force meter was constructed based on the load cell type of pressure transducers. Different adhesives (powder, paste and adhesive strips) were used in the study. Complete denture wearers were asked to bite on the load cell and the readings of incisal bite force were recorded. The readings of incisal bite force were subjected to statistical analysis using Repeated measures ANOVA followed by post-hoc bonferroni test. RESULTS. The result suggests that denture adhesives improved the incisal bite force of complete denture wearers significantly The incisal bite force (in kg) in Group A without using adhesives, with powder adhesive, with paste adhesive and with adhesive strips was found to be 2.48 (${\pm}0.16$), 3.43 (${\pm}0.11$), 6.01 (${\pm}0.11$), 3.22 (${\pm}0.09$) respectively. The incisal bite force (in kg) in Group B without using adhesives, with powder adhesive, with paste adhesive and with adhesive strips was found to be 1.87 (${\pm}0.18$), 3.35 (${\pm}0.14$), 5.34 (${\pm}0.18$), 3.21 (${\pm}0.12$) respectively. The incisal bite force (in kg) in Group C without using adhesives, with powder adhesive, with paste adhesive and with adhesive strips was found to be 1.00 (${\pm}0.17$), 3.07 (${\pm}0.14$), 4.37 (${\pm}0.26$), 2.99 (${\pm}0.14$) respectively. CONCLUSION. Within the limitations of the study, it was concluded that the use of denture adhesive was found to be significantly effective in improving the incisal bite force of complete dentures until the dislodgement of upper denture. Fittydent paste adhesive was found to be more effective than the powder and strips adhesives. The improvement in incisal bite force was found to be higher in Group C in comparison to that of Group A and Group B.

Evaluation of bite force, quality of life, and patients' satisfaction in elderly edentulous patients using implant overdentures

  • Esra Nur Avukat;Canan Akay;Emre Mumcu
    • The Journal of Advanced Prosthodontics
    • /
    • v.15 no.4
    • /
    • pp.214-226
    • /
    • 2023
  • PURPOSE. This study aimed to compare the bite force (BF) between complete dentures and implant overdentures (IODs) retained by two mandibular implants. Additionally, we evaluated the quality of life (QoL) and patient satisfaction among individuals using IODs. In addition, the effects of demographic parameters such as age and sex, and clinical parameters such as implant length, implant diameter, attachment height, attachment color, and interimplant distance on BF, QoL, and patient satisfaction were evaluated. MATERIALS AND METHODS. A total of 51 edentulous patients rehabilitated with the maxillary complete dentures and mandibular IODs retained by two implants were included in this study. BF was measured using a force meter pre- and post-implant in the same patients. Oral health-related quality of life (OHRQoL) was assessed with the Oral Health Impact Profile (OHIP-14) and patient satisfaction was assessed with the Visual Analog Scale (VAS) questionnaires. RESULTS. It was found that BF values were statistically higher for IODs than complete dentures (P < .001). In terms of attachment height of the OHIP scores, there was a significant difference in the psychological disability and social disability domains (P < .05). When examining the change in patient satisfaction as a function of sex, it was found that mandibular retention satisfaction differed significantly by sex (P < .05), but there was no significant difference in the other domains. CONCLUSION. Within the limitations of this study, it was observed that the BF increased after the use of IODs. Several factors, including age, interimplant distance, attachment height, and attachment color, were found to impact OHRQoL. Sex and implant diameter were identified as factors affecting patient satisfaction.

EFFECT OF TAPER AND SURFACE AREA OF INNER CROWN ON THE RETENTIVE FORCE OF ELECTROFORMED OUTER CROWN (전기성형술로 제작된 외관의 유지력에 내관의 축면경사도와 표면적이 미치는 영향)

  • Kang Wan-Keun;Lim Jang-Seop;Jeon Young-Chan;Jeong Chang-Mo;Jeong Hee-Chan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.2
    • /
    • pp.165-173
    • /
    • 2006
  • Purpose: With gold electroforming system fir the double crown, the secondary crown is electroformed directly onto the primary crown. An even thick layer of high precision can be acquired. It is thought that the retention of electroformed outer crown is primarily acquired by the adhesive force (surface tension) through the saliva which is interposed between precisely fitted inner and outer crown. The purpose of this study was to investigate the effect of taper and surface area of inner crown on the retentive force of electroformed outer crown according to the presence of saliva. Materials and methods: 32 titanium inner crowns with cervical diameter of 8 mm and cone angles of 0, 2, 4, 6 degrees, which had same surface area by regulated height, were machined on a lathe. Another 32 titanium inner crowns with cone angles of 0, 2, 4, 6 degrees, which had doubled surface area by increased cervical diameter. were fabricated. Eight specimens of each group, for a total of 64 titanium inner crowns, were prepared. The electroformed outer crowns were fabricated directly on the inner crowns by using electroforming machine(GAMMAT free, Gramm Technik, Germany). The tertiary frameworks were waxed-up on the electroformed outer crown and cast using nonprecious alloy($Rexillium^(R)III,\;Jeneric^(R)/Pentronh^(R)$ Inc., USA). The cast metal frameworks were sandblasted with alubimium oxides and cemented using resin cement(Superbond C&B, Sun Medical Co., Japan) over the electroformed copings of each specimen. Then, artificial saliva($Taliva^(R)$, Halim Pharm. Co., Korea) was sprayed between the inner and outer crown, and they were connected under 5 kg force. The retentive force was measured by the universal testing machine(Tinius Olsen 1000, Tinius Olsen, USA) with a cross-head speed of 66.67 mm/sec. The direction of cross-head travel was exactly aligned with the path of removal of the respective specimens. This measurement procedures for retentive force of electroformed outer crown with artificial saliva were repeated in the same way without presence of artificial saliva. Results and Conclusion: The following conclusions were drawn: 1. The retentive force of electroformed outer crown was decreased according to increased taper of inner crown(P<.05). 2. The retentive force of electroformed outer crown showed no significant differences according to surface area and the presence of artificial saliva(P>.05).

IMPROVEMENT EFFECTS OF ELECTROCHEMICAL STABILITY OF MAGNETIC MATERIALS FOR PROSTHETIC DENTISTRY (치과보철용 자석재료의 전기화학적 안정성 개선효과)

  • Kwack, Jong-Ha;Oh, Sang-Ho;Choe, Han-Cheol;Chung, Chae-Heon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.5
    • /
    • pp.628-641
    • /
    • 2006
  • Statement of problem: Dental magnetic materials have been applied to removable prosthetic appliances, maxillofacial prostheses, obturator and dental implant but they still have some problems such as low corrosion resistance in oral environments. Purpose: To increase the corrosion resistance of dental magnetic materials, surfaces of Sm-Co and Nd-Fe-B based magnetic materials were plated with TiN and sealed with stainless steels. Materials and methods : Surfaces of Sm-Co and Nd-Fe-B based magnetic materials were plated with TiN and sealed with stainless steels, and then three kinds of electrochemical corrosion test were performed in 0.9% NaCl solution; potentiodynamic, potentiostatic, and electrochemical impedance test. From this study, corrosion behavior, amount of elements released, mean average surface roughness values, the changing of retention force, and magnetic force values were measured comparing with control group of non-coated magnetic materials. Results: The values of surface roughness of TiN coated Sm-Co and TiN coated Nd-Fe-B based magnetic materials were lower than those of non coated Sm-Co and Nd-Fe-B alloy. From results of potentiodynamic test, the passive current density of TiN coated Sm-Co alloy were smaller than those of TiN coated Nd-Fe-B alloy and non coated alloys in 0.9% NaCl solution. From results of potentiostatic and electrochemical impedance test, the surface stability of the TiN coated Sm-Co alloy was more drastically increased than that of the TiN coated Nd-Fe-B alloy and non-coated alloy. The retention and magnetic force after and before corrosion test did not change in the case of TiN coated magnetic alloy sealed with stainless steel. Conclusion: It is considered that the corrosion problem and improvement for surface stability of dental magnetic materials could be solved by ion plating with TiN on the surface of dental magnetic materials and by sealing with stainless steels.

A Study on the changes of periodontal tissue after orthodontic tooth movement in young adult dogs (유성견에서 교정적 치아이동에 따른 치주조직 변화에 관한 연구)

  • Kang, Nam-Yong;Yoon, Young-John;Kim, Kwang-Won
    • The korean journal of orthodontics
    • /
    • v.27 no.4 s.63
    • /
    • pp.559-568
    • /
    • 1997
  • For orthodontic tooth movement, optimal orthodontic force should be maintained without periodontal breakdown and alveolar bone should be remodeled physiologically Therefore, To obtain proper occlusion through tooth movement within alveolar bone, we should know the biomechanics of teeth and supporting 4issues. The present study was performed to observe histologic changes of periodontal tissue immediately after application of orthodontic force and during the retention period in growing young adult dogs. In this study, experimental group contained between mandibular left canine and 1st molar and control group contained contralateral teeth of same animal. The .018'x.022' stainless steel closed coil spring(Dentaurum Co.) was ligated on the experimental teeth at initial 200gm-force from mandibular canine to 1st molar The animals(4 to 6 months aged young adult dogs) were sacrificed on 0, 14, 28 days after the finish of appliance activation, and then tissue samples were divided into hematoxylin-eosin(HE) staining section, ground section, alkaline phosphatase(ALP) staining section, and tartrate-resistant acid phosphatase(TRAP) staining section. Thereafter, the preparations were examined under light microscopy The following results were obtained: 1. Immediately after the finish of appliance activation, the periodontal space was increased in tension side, but decreased in pressure side compared to that of control. The hyalinized zone was also observed in the periodontium. 2. After the 14-day retention, peridontal space was decreased in tension side and slightly increased in pressure side compared to that of immediately after the finish of appliance activation. The hyalinized zone was repaired and a few osteoblasts showing slightly new bone formation were seen. Osteoblasts were scarcely observed along the alveolar bone. 3. Aftter the 28-day retention, the periodontal fibers are normally repaired. A lot of TRAP(+) osteoclasts md increased alveolar bone resorption were observed in pressure side, and AP(+) osteoblast and increased new bone formation were observed in tension side.

  • PDF

THE BONE CHANGES OF THE MIDPALATAL SUTURE AFTER RAPID PALATAL EXPANSION IN YOUNG ADULT DOGS (유성견에서 상악골 급속확장 후 정중구개봉합부에서의 골조직 변화)

  • Park, Chang-Wook;Yoon, Young-Jooh;Kim, Kwang-Won
    • The korean journal of orthodontics
    • /
    • v.27 no.3 s.62
    • /
    • pp.391-399
    • /
    • 1997
  • Rapid palatal expansion(RPE) is a method of inducing the new bone formation in the palate by separation of the midpalatal suture, which can be done conveniently by placing heavy force across the maxillary dental arch. This experiment was undertaken to examine the histologic changes after RPE and during retention period. Four young adult dogs(a control dog, three experimental dogs) aged 4 to 6 months old were used for this experiment. Expansion screw($Hyrax^{\circledR}$, Dentarum Inc.) was delevered to the palate and fumed 180 degrees every morning and evening for 8 days, giving a total expansion of 7.2mm. A control dog was sacrified at the starting point of this study without any treatment and three experimental dogs were sacrified after RPE, 14-day retention, and 28-day retention in each. Thereafter, those samples were observed with hematoxylin-eosin(H-E) stain, ground section(Villanueva stain), alkaline phosphatase(ALP) stain, tartrate-resistant acid phosphatase(TRA) stain. The results were as followings: 1. After RPE, collagen fiber bundles were stretched along the midpalatal suture and few osteoblasts were flattened-inactive state and also, a little osteoid tissues was observed. Few multinucleated osteoclasts which had TRAP-positive activity in their cytoplasm were seen in horizontal section, whereas a few osteoclasts were seen in frontal section, especially in the nasal floor side of palatal bone. 2. After 14-day retention, collagen fiber bundles were stretched along the midpalatal suture and few osteoblasts which had ALP-positive activity in their cytoplasm were seen. Few multinucleated osteoclasts which had TRAP-positive activity in their cytoplasm were seen in horizontal section, whereas a few osteoclasts were seen in frontal section, especially in the nasal floor side of palatal bone. 3. After 28-day retention, collagen fiber bundles were arranged like those of control dog and osteoblasts which showed a lot of immature bone formation were cuboidal shape and exhibited ALP-positive activity in their cytoplasm. Few multinucleated osteoclasts which had TRAP-positive activity in their cytoplasm were seen in horizontal section, whereas a few osteoclasts were seen in frontal section, especially in the nasal floor side of palatal bone. According to the above results, the new bone formation after rapid palatal expansion was examined after 14-day retention and significantly increased after 28-day retention.

  • PDF

A Study on Setting Quality Level of Fastener Tape for Military Textile Products (군용 섬유제품에 적합한 파스너 테이프의 품질수준 연구)

  • Kim, Seongwook;Lee, Minhee;Hong, Seongdon;Lee, Jung-Soon
    • Textile Coloration and Finishing
    • /
    • v.29 no.3
    • /
    • pp.162-170
    • /
    • 2017
  • Fastener tapes are widely used as auxiliary materials in textile products, and military textiles products are also applied. However, in Korea, the HL3-WA class of KS K 1309 was applied to military uniforms without consideration of the operating environment. Instead of adopting the standard of initial strength for Korean military uniforms, the US military applied the value after 3 washings, and presented different properties according to the items. Also in Japan, the standard was applied differently according to products in general clothing. The purpose of this study in to examine the quality level of fastener tapes used for military materials. The changes of tensile shear strength and peel strength of military and commercial fastener tape were studied after washing. As a result, the initial strength of the current military fastener tapes was higher than commercial one, but the strength retention rate was rapidly decreased as the number of washing. So it was confirmed that the decrease in strength was relatively lower than commercial one. It is necessary to improve the durability by adjusting the adhesive strength to suit the purpose of the product, and it is necessary to consider the priority of maintaining the durability according to the initial performance and repeated use according to the use environment, respectively.