• 제목/요약/키워드: Retention force

검색결과 169건 처리시간 0.106초

Measurement and assessment of sports wear fabric clinginess

  • Kim, Jooyong;Koo, Ji-Eun;Koo, Hyun-Jin
    • 한국섬유공학회:학술대회논문집
    • /
    • 한국섬유공학회 2003년도 The Korea-Japan Joint Symposium
    • /
    • pp.113-113
    • /
    • 2003
  • Four main factors, cling force, wicking force, water retention and water transport, affecting the clinginess of the sportswear fabric have been identified and measured by combining a new equipment and a statistical analysis. A classification model based on those factors has been developed in order to evaluate and standardize fabric wear comforts during heavy physical acting. Ten sportswear fabrics assumed different in their wear characteristics have been employed to investigate the relationship between the measurements and actual performance. It has been shown that the subjective evaluation ratings were well agreed with the measurement.

  • PDF

변형된 설측호선 장치를 이용한 매복 대구치의 인위적 맹출

  • 박상진;문철현
    • 대한치과의사협회지
    • /
    • 제44권2호통권441호
    • /
    • pp.123-132
    • /
    • 2006
  • Patients who have impacted tooth are found commonly in orthodontic treatment. Although it is difficult to find the cause of impacted teeth, the most common, causes are prolonged retention of the deciduous teeth, trauma, aberrant sequence of eruption, lack of space and deficiency of Vitamin D. Impacted teeth may lead to esthetic and functional problems and root resorption of adjacent teeth, so we should treat it as soon as possible. Commonly used treatment method is the following: After surgically uncovering of the impacted teeth, a bond of orthodontic appliance is established, and orthodontic traction is started with a removable or fixed appliance. We used the modified lingual arch with a soldered auxiliary appliance in lingual arch for traction of lower impacted teeth. The modified lingual arch could control the magnitude and direction of the applied force with one-arch treatment, and also could give continuous force to impacted tooth without patient patient cooperation. We achieved good results with the modified lingual arch.

  • PDF

Correction of late adolescent skeletal Class III using the Alt-RAMEC protocol and skeletal anchorage

  • Muhammed Hilmi Buyukcavus;Omer Faruk Sari;Yavuz Findik
    • 대한치과교정학회지
    • /
    • 제53권1호
    • /
    • pp.54-64
    • /
    • 2023
  • This case report describes skeletal anchorage-supported maxillary protraction performed with the Alternate Rapid Maxillary Expansion and Constriction (AltRAMEC) protocol over a treatment duration of 14 months in a 16-year-old female patient who was in the late growth-development period. Miniplates were applied to the patient's aperture piriformis area to apply force from the protraction appliance. After 9 weeks of following the Alt-RAMEC protocol, miniplates were used to transfer a unilateral 500-g protraction force to a Petit-type face mask. A significant improvement was observed in the soft tissue profile in measurements made both cephalometrically and in three dimensional photographs. Subsequently, the second phase of fixed orthodontic treatment was started and the treatment was completed with the retention phase. Following treatment completion, occlusion, smile esthetics, and soft tissue profile improved significantly in response to orthopedic and orthodontic treatment.

상악 전치부 고정성 보철물 수복 시 임시 임플란트를 이용한 임시보철물의 유지력 증가 증례보고 (Reinforcing the retention of provisional restoration using provisional implant on maxillary anterior region: clinical case report)

  • 김창대;문홍석;정문규;이재훈
    • 대한치과보철학회지
    • /
    • 제51권3호
    • /
    • pp.221-225
    • /
    • 2013
  • 임시 보철물의 적절한 관리는 보철의 성공에 있어서 중요한 요소이다. 상악 전치 결손부 임시 보철물은 장경간의 결손부가 존재하거나, 타원형의 악궁을 가진 환자에서 자주 탈락하게 된다. 이는 상악 전치부가 구치부에 비해서 수평적인 힘에 더 많이 노출되며, 부가적으로 전방 캔틸레버 효과가 임시 보철물의 유지를 저해하고, 상악 전치부 임시 보철물은 하악의 기능 운동시 적절한 전방 유도를 제공하여야 하기 때문이다. 또한 임시 보철물의 최대 감합위에서 교합접촉은 지점선의 반대편에 위치하게 되어 그 자체로 임시 보철물의 탈락을 야기한다. 본 증례에서는 임시 임플란트를 이용하여 상악 전치부 보철물에 대한 전술한 유해 작용을 피할 수 있었고, 발치 후 치유기간 동안 환자에게 편안함과 만족감을 부여하였으므로 이를 보고하는 바이다.

수분에 의존하는 단백질의 특성이 어묵의 조직에 미치는 영향 (Moisture-dependent Gelation Characteristics of Nonfish Protein Affect the Surimi Gel Texture)

  • Chung, Kang-Hyun;Lee, Chong-Min
    • 한국식품조리과학회지
    • /
    • 제12권4호
    • /
    • pp.571-576
    • /
    • 1996
  • The moisture-dependent gelation characteristics of five different proteins are evaluated to understand the modification of gel strength when they are added in surimi gel. Compressive force and penetration force of protein gels gradually decreased with increase of moisture level, with showing markedly decrease at certain point of moisture level called critical moisture level. The critical moisture level for gelation of SPI-1, SPI-2, EW, WPC and LA were 79.4%, 81.6%, 91.4%, 87,8% and 84.7%, respectively. Beyond this critical level of water, protein gel matrix begins to lose its water binding and structural integrity. The mnisture that was not re tained by a protein was available to diluting the protein matrix and eventually weakened the overall gel strength. EW and MPI showed higher water retention than those of SPI, WPC and LA. The compressive force of SPI, WPC and LA-incorporated surimi gel at the varying moisture levels strongly correlated with the amount if water retained at corresponding moisture level within those protein (r=0.99).

  • PDF

탐침형 정보 저장장치에 응용 가능한 강유전체 물질의 특성 연구 (Properties of Ferroelectric Materials Applicable to Nano-storage Media)

  • 최진식;김진수;황인록;변익수;김수홍;전상호;이진호;홍사환;박배호
    • 한국진공학회지
    • /
    • 제15권2호
    • /
    • pp.173-179
    • /
    • 2006
  • Pulsed laser deposition 방법으로 증착한 $PbZr_{0.3}Ti_{0.7}O_{3}$ (PZT)박막의 구조적, 전기적 성질에 대한 연구를 하였다. PZT 박막은 $LaAlO_3$ 기판위에 동일한 조건으로 증착된 $LaMnO_3$ (LMO) 산화물을 하부 전극으로 하여 증착시간을 변화시키며 증착하였다. High-resolution x-ray diffraction 결과를 통해 LMO 하부 전극과 PZT 박막이 방향성 있게 자란 것을 확인할 수 있었고 박막의 두께는 field-emission scanning electron microscope을 통하여 측정할 수 있었다. 또한 우리는 atomic force microscopy을 이용하여 박막의 표면 거칠기를 구하였고 국소적인 범위의 전기적 특성은 piezoelectric force microscopy 모드를 이용하여 측정하였다. 그 결과 PZT/LMO 구조는 나노 스토리지의 미디어로 쓰이기 위해 필요한 성질들을 갖추었음을 알 수 있었다.

Comparison of retentive force and wear pattern of Locator® and ADD-TOC attachments combined with CAD-CAM milled bar

  • Chae, Sung-Ki;Cho, Won-Tak;Choi, Jae-Won;Bae, Eun-Bin;Bae, Ji-Hyeon;Bae, Gang-Ho;Huh, Jung-Bo
    • The Journal of Advanced Prosthodontics
    • /
    • 제14권1호
    • /
    • pp.12-21
    • /
    • 2022
  • PURPOSE. The purpose of this study was to investigate changes in retention and wear pattern of Locator® and ADD-TOC attachments on a digital milled bar by performing chewing simulation and repeated insertion/removal of prostheses in fully edentulous models. MATERIALS AND METHODS. Locator (Locator®; Zest Anchors Inc., Escondido, CA, USA) was selected as the control group and ADD-TOC (ADD-TOC; PNUAdd Co., Ltd., Busan, Republic of Korea) as the experimental group. A CAD-CAM milled bar was mounted on a master model and 3 threaded holes for connecting a bar attachment was formed using a tap. Locator and ADD-TOC attachments were then attached to the milled bar. Simulated mastication and repeated insertion/removal were performed over 400,000 cyclic loadings and 1,080 insertions/removals, respectively. Wear patterns on deformed attachment were investigated by field emission scanning electron microscopy. RESULTS. For the ADD-TOC attachments, chewing simulation and repeated insertion/removal resulted in a mean initial retentive force of 24.43 ± 4.89 N, which were significantly lower than that of the Locator attachment, 34.33 ± 8.25 N (P < .05). Amounts of retention loss relative to baseline for the Locator and ADD-TOC attachments were 21.74 ± 7.07 and 8.98 ± 5.76 N (P < .05). CONCLUSION. CAD-CAM milled bar with the ADD-TOC attachment had a lower initial retentive force than the Locator attachment. However, the ADD-TOC attachment might be suitable for long-term use as it showed less deformation and had a higher retentive force after simulated mastication and insertion/removal repetitions.

시멘트의 종류 및 임플란트 지대주 높이가 지르코니아 수복물의 제거력에 미치는 영향 (Influence of varying cement types and abutment heights on pull-off force of zirconia restorations)

  • 정영준;김유리;정지혜;강내운;공현준
    • 구강회복응용과학지
    • /
    • 제40권2호
    • /
    • pp.64-71
    • /
    • 2024
  • 목적: 본 연구의 목적은 세 가지 높이를 가진 티타늄 베이스 임플란트 지대주에서 세 종류의 시멘트가 지르코니아 수복물에서 가지는 제거력을 비교하는 것이다. 연구 재료 및 방법:. 90개의 직경 4.0 mm 임플란트 아날로그가 레진 블록에 식립되었다. 이후 3 mm, 5 mm, 7 mm의 높이를 가지도록 임플란트 지대주를 30개씩 제작하였고, 각 지대주를 스캔하여 지르코니아 수복물 시편을 제작하였다. 임시 시멘트(TB), 반영구 시멘트(CI), 영구 시멘트(FC)를 각자 제조사의 지시에 따라 지대주에 접착하였다. 제작된 90개의 시편은 만능시험기에서 제거력을 시험하였으며, 모든 제거력은 부하량이 하락하기 직전 가장 높은 값에서 측정되었다. 통계 분석은 지대주의 높이, 시멘트의 종류에 대해 각각 Kruskal-Wallis test (P = 0.05) 후 Mann-Whitney U test (P = 0.0167)로 사후 검정 시행하였다. 결과: 임플란트 지대주의 높이에 상관없이 TB에 비해 FC의 제거력이 높았다. CI와 FC간에는 3 mm와 7 mm에서는 유의미한 차이가 있었으나 5 mm에서는 유의미한 차이가 없었다. TB와 CI간에는 5 mm에서만 유의미한 차이가 있었다. 결론: 시멘트의 종류는 지르코니아 수복물의 제거력에 유의미한 영향을 끼쳤으나, 임플란트 지대주의 높이는 유의미한 영향을 주지 않았다.

골다공증 모델 흰쥐에서 고수준의 단백질의 칼슘 섭취가 칼슘대사 및 신장기능에 미치는 영향 (Effects of High Protein and Calcium Intakes on Calcium Metabolism and Renal Function in Ovariectomized Osteporosis Rat Model)

  • 오주환
    • Journal of Nutrition and Health
    • /
    • 제30권6호
    • /
    • pp.605-613
    • /
    • 1997
  • This study was to investigate interaction between dietary protein and Ca levels in Ca metabolism and renal function in osteporosis rats. Five week-old female rats were fed a low Ca diet for 4 weeks after ovariectomy operation to establish rat models of osteoporosis. The ovariectomized osteoporosis rats were divided into six groups and were fed experimental diets which contained two levels of protein, normal (20%) and high(40%) , and three levels of Ca, low (0.06%), normal (0.47%) and high(0.94%) for 4 weeks , respectively. The ovaricetmized rat model of osteoporosis showed a remarkable decrease in serum Ca concentration, fresh weight and breaking force of femur, Ca and P contents of femur, and apparent absorption and retention of Ca. The supplementations of Ca and P contents of femur, and apparent absorption and retention of Ca. The supplementations of Ca at the dietary levels of normal and high levels significantly enhanced Ca bioavailability shown in the above experimental rat models of osteoporosis, regardless of dietary protein levels ; whereas the rats which were fed the low Ca diet demonstrated rather a decrease in its bioavailability. Irrespectively of the dietary Ca levels, the rats which were fed high protein diet exhibited an increase in kidney weight, urinary Ca, volume and hydroxyproline, and glomerular filtration ratio(GFR). The results show that dietary protein and calcium levels affect the renal function and Ca metabolism independently, while the interaction between protein and calcium have not been shown.

  • PDF

하악에서 완압형 자성 어태치먼트를 부착한 임플란트-자연치 피개 의치: 10년 증례보고 (Mandibular implant-natural tooth retained overdenture using magnetic attachment with stress breaker)

  • 박은철;이수연;김희중
    • 구강회복응용과학지
    • /
    • 제31권4호
    • /
    • pp.378-386
    • /
    • 2015
  • 피개 의치는 의치의 안정과 유지력 증가라는 장점을 갖지만 지대치가 우식 또는 치주질환에 이환되기 쉬우며 의치의 두께가 얇아짐으로써 의치가 파절되기 쉽다는 단점도 갖고 있다. 자성 어태치먼트 피개 의치는 수직적 유지력은 크지만 수평적 유지력은 작으므로 지대치나 임플란트에 덜 위해한 힘을 가하며, 다른 기계적 유지장치에 비해 마모나 파손 등이 적다는 장점이 있다. 피개 의치에서 나타나는 의치의 파절은 의치상의 두께가 얇아져서 발생하기도 하지만, 연조직과 경조직, 임플란트와 자연치의 압하량 차이로 인해 발생하기도 한다. 이를 보상하기 위해 silicone ball이 자석 안에 삽입되어있는 자성 어태치먼트가 개발되었으며, 이를 이용해 피개 의치를 제작한 증례에서 우수한 결과가 나타나 보고하고자 한다.