• Title/Summary/Keyword: Retention and stability

Search Result 442, Processing Time 0.026 seconds

Encapsulation of Flavors by Molecular Inclusion Using $\beta$-Cyclodextrin: Comparison with Spray-drying Process Using Carbohydrate-based Wall Materials

  • Cho, Young-Hee;Park, Ji-Yong
    • Food Science and Biotechnology
    • /
    • v.18 no.1
    • /
    • pp.185-189
    • /
    • 2009
  • Microencapsulation of flavor was carried out by molecular inclusion process using $\beta$-cyclodextrin (${\beta}CD$). ${\beta}CD$-flavor complex was prepared at various flavor-to-${\beta}CD$ ratios (1:6-1:12) to determine the effect of ${\beta}CD$ concentration on the inclusion efficiency. Maximum total oil retention and minimal surface oil content were obtained at flavors to ${\beta}CD$ ratio of 1:10. The physical properties and controlled release pattern of flavors from ${\beta}CD$-flavor complex were measured and compared with spray-dried microcapsules prepared using carbohydrate wall system. ${\beta}CD$-flavor complex showed higher total oil retention and surface oil contents, smaller mean particle size, lower moisture uptake, and higher oxidation stability than spray-dried microcapsule. Oxidative stability of flavor was correlated with hygroscopicity of wall materials. The controlled release mechanism was highly affected by temperature and characteristics of wall materials.

Influence of late removal after treatment on the removal torque of microimplants

  • Kim, Ho-Jin;Park, Hyo-Sang
    • The korean journal of orthodontics
    • /
    • v.52 no.3
    • /
    • pp.201-209
    • /
    • 2022
  • Objective: To compare the removal torque of microimplants upon post-use removal and post-retention removal and to assess the influencing factors. Methods: The sample group included 241 patients (age, 30.25 ± 12.2 years) with 568 microimplants. They were divided into the post-use (microimplants removed immediately after use or treatment) and post-retention (microimplants removed during the retention period) removal groups. The removal torque in both groups was assessed according to sex, age, placement site and method, and microimplant size. Pearson correlation and multiple linear regression analyses were performed for evaluating variables influencing the removal torque. Results: The mean period of total in-bone stay of microimplants in the post-retention removal group (1,237 days) was approximately two times longer than that in the post-use removal group (656.28 days). The removal torques in the post-retention removal group (range, 4-5 N cm) were also higher than those in the post-use removal group. The mandible and pre-drilling groups demonstrated higher placement and removal torques than did the maxilla and no-drilling groups, respectively. In the no-drilling post-use removal group, the placement torque and microimplant length positively correlated with the removal torque. In the post-retention removal group, unloading in-bone stay period and microimplant diameter positively correlated with the removal torque in the no-drilling and pre-drilling methods, respectively. Conclusions: The removal torques differed according to the orthodontic loading and removal time of microimplants. With prolonged retention of microimplants inserted using the no-drilling method, the removal torque was clinically acceptable and positively correlated with the unloading in-bone stay period.

Surface gloss, gloss retention, and color stability of 2 nano-filled universal resin composites

  • Gustavo Fabian Molina;Ricardo Juan Cabral;Ignacio Mazzola;Michael Burrow
    • Restorative Dentistry and Endodontics
    • /
    • v.47 no.4
    • /
    • pp.43.1-43.13
    • /
    • 2022
  • Objectives: This study compared the surface gloss (SG), gloss retention (GR), and color stability (CS) of 2 universal resin composites after chemical (CA) and mechanical (MA) aging. Materials and Methods: Twenty disc-shaped samples of G-ænial A'Chord (GC-Europe) and Filtek Universal (3M-ESPE) were polished with sequential abrasive papers. For CA, specimens were stored in 1 mL of 75% ethanol for 15 days at 37℃, and readings (SG, GR, and CS) were obtained at baseline and 5, 10, and 15 days. For MA, specimens were subjected to 10,750 simulated brushing cycles. SG and CS were evaluated after every 3,583 cycles. SG was measured with a glossmeter (geometrical configuration: 60°), and values were expressed in gloss units. Color was measured with a spectrophotometer using the CIE-L*a*b* color system. The Student's t-test, 1-way analysis of variance, and Scheffé test were used for statistical analysis (α = 0.05). Results: G-ænial presented significantly higher SG values than Filtek (p = 0.02), with GR reductions of 5.2% (CA) and 5.3% (MA) for G-ænial and 7.6% (CA) and 7.2% (MA) for Filtek. The aging protocol had no statistically significant effect on SG or GR (p = 0.25) from baseline to the final readings. G-ænial-MA presented the lowest color difference (ΔE = 1.8), and G-ænial-CA and Filtek-CA had the largest changes (ΔE = 8.6 and ΔE = 11.8, respectively). Conclusion: G-ænial presented higher SG values and better CS. Both restorative materials demonstrated acceptable GR and CS. Aging protocols impacted these properties negatively.

Effects and clinical considerations of denture adhesives (의치 접착제의 효과 및 임상적 적용 시 고려 사항)

  • Park, Geun-Taek;Cho, Lee-Ra;Park, Chan-Jin;Huh, Yoon-Hyuk;Ko, Kyung-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.58 no.4
    • /
    • pp.385-391
    • /
    • 2020
  • Denture adhesive is a material used to improve the retention and stability of the denture. And denture adhesive is divided into soluble and insoluble type. It improves the retention, stability of dentures, and masticatory functions of patients. Maintenance like cleansing and periodic follow up is essential. Almost of dental clinicians are only simply aware of the effects of denture adhesives and often rely on the manufacturer's instructions on precautions and maintenance. The purpose of this study is to examine the properties, effects, and precautions of denture adhesives, and to present clinical guidelines for patients and professionals.

Evaluation of Post-Treatment Outcome of Sagittal Split Ramus Osteotomy in Mandibular Prognathism Patients (하악 전돌자의 하악지 시상분할 골절단술 후의 안정성에 대한 평가)

  • Chung, Dong-Hwa
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.22 no.4
    • /
    • pp.271-281
    • /
    • 2006
  • Long term prediction of surgical result of skeletal class III has not been evaluated adequately because the stability of orthognathic surgery would be affected by not only set back amount of mandible but also many other factors like skeletal pattern, hyoid position, and airway size. The aimof this study is to discriminate the factors which affect the stability of post-treatment result of surgical outcome of sagittal split ramus osteotomy. We have collected 37 patients (male: 17, female: 20) from patients who have been treated at Orthodontic Department in Dankook University. The patients underwent 3 times Cephalometric X-ray taking at pre-, post-orthognathic surgery and after 12 months retention. The subjects were divided into 2 groups (Stable group: 21, Relapse group: 16) according to their relapse amount. We have taken following results from Students t-test and discriminant analysis. The discriminant factors which discern relapse and stable groupe among treatment change variables were BX and Ba-HY. Hyoid bone moved to posterior and inferior position due to surgery and repositioned superiorly and posteriorly during retention period. Skeletal patterns of the relapse group are smaller mandibular plane angle, anterior mandibular position, and greater distance from hyoid bone to cervical bone and mandible respectively.

Neutral zone approach for rehabilitation of severely atrophic maxillary and mandibular ridges: A case report (치조제 흡수가 심한 환자에서 중립대를 이용한 총의치 수복 증례)

  • Lee, Ja-Youn;Choi, Sun-Young;Lee, Ji-Hyoun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.4
    • /
    • pp.407-412
    • /
    • 2016
  • The neutral zone technique is an alternative approach for the construction of complete dentures on highly atrophic ridges with history of denture instability. This technique achieves two objectives. First, the teeth will not interfere with the normal muscle function, and second, the force exerted by the musculature against the denture is more favorable for stability and retention. In this case of a 78-years-old female patient with severely atrophic ridges who had been using unstable complete dentures, the neutral zone impression technique was used to increase the stability and the retention of dentures. The neutral zone for both arch was located with modeling compound. After the arrangement of artificial teeth within the neutral zone, the external impression was taken to determine the tissue surface. The final dentures showed enhanced stability and retention and the patient was satisfied with the new dentures with respect to functional and esthetic aspects.

Stability of the prosthetic screws of three types of craniofacial prostheses retention systems

  • Lanata-Flores, Antonio Gabriel;Sigua-Rodriguez, Eder Alberto;Goulart, Douglas Rangel;Bomfim-Azevedo, Veber Luiz;Olate, Sergio;de Albergaria-Barbosa, Jose Ricardo
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.42 no.6
    • /
    • pp.352-357
    • /
    • 2016
  • Objectives: This study aimed to evaluate the stability of prosthetic screws from three types of craniofacial prostheses retention systems (bar-clip, ball/O-ring, and magnet) when submitted to mechanical cycling. Materials and Methods: Twelve models of acrylic resin were used with implants placed 20 mm from each other and separated into three groups: (1) bar-clip (Sistema INP, São Paulo, Brazil), (2) ball/O-ring (Sistema INP), and (3) magnet (Metalmag, São Paulo, Brazil), with four samples in each group. Each sample underwent a mechanical cycling removal and insertion test (f=0.5 Hz) to determine the torque and the detorque values of the retention screws. A servo-hydraulic MTS machine (810-Flextest 40; MTS Systems, Eden Prairie, MN, USA) was used to perform the cycling with 2.5 mm and a displacement of 10 mm/s. The screws of the retention systems received an initial torque of 30 Ncm and the torque values required for loosening the screw values were obtained in three cycles (1,080, 2,160, and 3,240). The screws were retorqued to 30 Ncm before each new cycle. Results: The sample was composed of 24 screws grouped as follows: bar-clip (n=8), ball/O-ring (n=8), and magnet (n=8). There were significant differences between the groups, with greater detorque values observed in the ball/O-ring group when compared to the bar-clip and magnet groups for the first cycle. However, the detorque value was greater in the bar-clip group for the second cycle. Conclusion: The results of this study indicate that all prosthetic screws will loosen slightly after an initial tightening torque, also the bar-clip retention system demonstrated greater loosening of the screws when compared with ball/O-ring and magnet retention systems.

Clinical application of mandibular removable partial denture using implant-supported surveyed crown: A case report (임플란트 지지 서베이드 금관을 이용한 하악의 가철성 국소의치 수복 증례)

  • Park, Jae-Ho;Min, Byung-Kwee;Yang, Hong-So;Park, Chan;Park, Sang-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.2
    • /
    • pp.154-160
    • /
    • 2018
  • When making conventional removable partial denture for the remaining teeth where the remaining teeth are only on one side, rotation of the denture occurs -in function- on the axis of the connected remaining teeth. If the edentulous portion is long, it becomes harder to obtain retention and stability for the abutment as the importance of the mucous membrane support is elevated. Such movements of denture decrease denture retention and stability, put excessive stress on the abutment, and give bad influence on periodontal health. Therefore, additional implant placement can be of a good choice in gaining additional retention and stability for partial denture. Thus hereby we report this clinical case as successful results were obtained by placing implants symmetrical to the remaining teeth and putting implant-supported surveyed crowns on the implants, allowing the partial denture to be designed to accept varying components and to have suitable path of insertion.

Performance of IPS Earth Retention System in Soft Clay (연약지반에 적용된 IPS 흙막이 시스템의 거동 특성)

  • Kim, Nak-Kyung;Park, Jong-Sik;Oh, Hee-Jin;Han, Man-Yop;Kim, Moon-Young;Kim, Sung-Bo
    • Journal of the Korean Geotechnical Society
    • /
    • v.23 no.3
    • /
    • pp.5-13
    • /
    • 2007
  • The performance of innovative prestressed support (IPS) earth retention system applied in soft clay was investigated and presented. The IPS wale system provides a high flexural stiffness to resist the bending by lateral earth pressure, and transfers lateral earth pressure to strut supports. The IPS wale system provides a larger spacing of support than conventional braced and anchored systems. The IPS earth retention system was selected for temporary earth support in a building construction in North Busan area. The excavation was made 28.8 m wide, 52.0 m long, and 16.1 m deep through loose fill to soft clay. The IPS system consists of 650 mm thick slurry walls, and five levels of IPS wales and struts. Field monitoring data were collected including wall deflections at six locations, ground water levels at four locations, IPS wale deflections at thirty locations, and axial loads on struts at twenty locations, during construction. The IPS earth retention system applied in soft clay performed successfully within a designed criterion. Field measurements were compared with design assumptions of the IPS earth retention system. The applicability and stability of the IPS earth retention system in soft clay were investigated and evaluated.

Characteristics and Stability of Violet Red Pigment Extracted from Salicornia herbacea L. (퉁퉁마디(Salicornia herbacea L.)에서 추출한 적자색 색소의 특성 및 안정성)

  • Lee, Young-Jae;Park, In-Bae;Kim, Hae-Seop;Shin, Gung-Won;Park, Jeong-Wook;Jo, Yeong-Cheol
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.38 no.7
    • /
    • pp.885-891
    • /
    • 2009
  • To examine stability of a violet red pigment in a Salicornia herbacea L., several tests for pH, sugar, organic acid, ascorbic acid, amino acid, salt and temperature effect were carried out. A violet red pigment in Salicornia herbacea L. was the most stable in the range of pH 4 to 6. Each of the violet red pigments in Salicornia herbacea L. added with different amounts of sugar showed higher retention rate according to storage time than those of the control group. After 10 days of storage, especially the retention rate of the experimentals with 0.5 M sucrose was higher than the controls by about 11.1% while fructose, maltose, glucose and galactose were less higher in order. Also, adding organic acid reduced retention rate of the experimentals over the controls irrespective of sort and concentration of organic acid; also, the retention rate of the experiment with 0.5 M organic acid, the highest amount of all, reduced radically to 13.1 to 15.9% after 10 days storage. The retention rate of the experimentals added 1,000 ppm ascorbic acid and thio urea respectively after 10 days was 48.4%, which is higher than the controls by around 23.1%. As to amino acid, treatment on the pigment with aspartic acid 50 mM marked the highest retention rate of 41.5% and treatment with 2.0 M NaCl showed 31.6% retention rate, which was higher than the controls. While low temperature like $5^{\circ}C$ and $25^{\circ}C$ kept the stability of the pigment in storage, as temperature increased the stability of the pigment dropped rapidly.