• Title/Summary/Keyword: Result Analysis and Evaluation

Search Result 5,763, Processing Time 0.042 seconds

Applicability Evaluation on the Analytical Formulas of the Scour Depth Estimation in the Bight River (교량세굴심 산정을 위한 만곡부하천에서의 산정식 적용성 평가)

  • Park, Soo-Jin;Park, Jae-Wan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.10
    • /
    • pp.4845-4852
    • /
    • 2012
  • This research calculated the scour depth of bridge according to inflow and outflow changes of stream's flood discharge and curves by applying scour depth formula for piers and abutments, and by comparing and examining them, evaluated the applicability of scour depth formulas. Overall, if the angles of flood discharge and inflow and outflow increase, the deviation rate of scour depth in bight increased. Especially the deviation rate was 58% at the inflow and outflow angle of $105^{\circ}$ that the bridge plan for this geography need careful examination. Next, as a result of calculating the deviation rate of scour depth at the bight by scour depth formulas, in case of pier, Andru formula showed 58% deviation rate, Laursen formula showed 26% deviation rate, and CSU. formula showed 17% deviation rate. In the case of abutment, Froehlich formula shows 44% deviation rate that when applying above scour depth formulas, scour depth calculation considering repairable characteristics of bight is necessary. Finally, about inflow and outflow angles of $45^{\circ}{\sim}135^{\circ}$ that showed big deviation rate of scour depth, this research performed regression analysis of deviation rates of scour depth due to flood discharge to suggest the regression formula.

A Tunable Transmitter - Tunable Receiver Algorithm for Accessing the Multichannel Slotted-Ring WDM Metropolitan Network under Self-Similar Traffic

  • Sombatsakulkit, Ekanun;Sa-Ngiamsak, Wisitsak;Sittichevapak, Suvepol
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.777-781
    • /
    • 2004
  • This paper presents an algorithm for multichannel slotted-ring topology medium access protocol (MAC) using in wavelength division multiplexing (WDM) networks. In multichannel ring, there are two main previously proposed architectures: Tunable Transmitter - Fixed Receiver (TTFR) and Fixed Transmitter - Tunable Receivers (FTTR). With TTFR, nodes can only receive packets on a fixed wavelength and can send packets on any wavelengths related to destination of packets. Disadvantage of this architecture is required as many wavelengths as there are nodes in the network. This is clearly a scalability limitation. In contrast, FTTR architecture has advantage that the number of nodes can be much larger than the number of wavelength. Source nodes send packet on a fixed channel (or wavelength) and destination nodes can received packets on any wavelength. If there are fewer wavelengths than there are nodes in the network, the nodes will also have to share all the wavelengths available for transmission. However the fixed wavelength approach of TTFR and FTTR bring low network utilization. Because source node with waiting data have to wait for an incoming empty slot on corresponding wavelength. Therefore this paper presents Tunable Transmitter - Tunable Receiver (TTTR) approach, in which the transmitting node can send a packet over any wavelengths and the receiving node can receive a packet from any wavelengths. Moreover, the self-similar distributed input traffic is used for evaluation of the performance of the proposed algorithm. The self-similar traffic performs better performance over long duration than short duration of the Poison distribution. In order to increase bandwidth efficiency, the Destination Stripping approach is used to mark the slot which has already reached the desired destination as an empty slot immediately at the destination node, so the slot does not need to go back to the source node to be marked as an empty slot as in the Source Stripping approach. MATLAB simulator is used to evaluate performance of FTTR, TTFR, and TTTR over 4 and 16 nodes ring network. From the simulation result, it is clear that the proposed algorithm overcomes higher network utilization and average throughput per node, and reduces the average queuing delay. With future works, mathematical analysis of those algorithms will be the main research topic.

  • PDF

Reliability Evaluation of Rubber Wheel and Steel Wheel for Wheel Tracking Test of Bituminous Concretes (역청 콘크리트 반복주행시험에서 고무바퀴와 강재바퀴의 신뢰성 비교 연구)

  • Hong, Joon-Pyo;Doh, Young-Soo;Kim, Kwang-Woo
    • International Journal of Highway Engineering
    • /
    • v.7 no.2 s.24
    • /
    • pp.97-107
    • /
    • 2005
  • Since the purpose of wheel tracking test is to find out relative difference of mixture's rut resistance, the wheel is an important part in the test for obtaining a consistent output. This study is performed to examine efficiency of different wheel material, rubber and steel in wheel tracking test. The rubber was inserted as a ring on the outer face of the steel wheel, and thickness of rubber ring was 15mm and 7.5mm and 0mm (steel wheel without rubber), making the total outer diameter 200mm. The objective of this study was to select reliable wheel material type in wheel tracking test at $60^{\circ}C$ based on variance in output (rut depth and dynamic stability) and correlation with SD (deformation strength). The result of regression analysis of rut depth with Sd showed that $R^2$ values of wheel rubber thickness of 15mm, 7.5mm and 0mm were 0.7, 0.8 and over 0.9, respectively. In a case of steel wheel (0mm), the highest $R^2$ value was 0.9569. Therefore, the wheel without rubber ring was the best in output consistency level and coefficient of determination $(R^2)$ with deformation strength. Therefore, the steel wheel without rubber ring is suggested as the best choice for wheel tracking test of asphalt concrete.

  • PDF

Evaluation of Pollution Loads Removal Efficiency of Vegetation Buffer Strips Using a Distributed Watershed Model (분포형 유역모델을 이용한 식생여과대의 오염부하 저감효과 분석)

  • Park, Min-Hye;Cho, Hong-Lae;Koo, Bohn Kyoung
    • Journal of Environmental Impact Assessment
    • /
    • v.25 no.6
    • /
    • pp.369-383
    • /
    • 2016
  • A distributed watershed model CAMEL(Chemicals, Agricultural Management and Erosion Losses) was applied to a part of grazing grassland and vegetation buffer strip(VBS) located in Daegwanryeong, Korea. A set of scenario analyses was carried out for grassland and VBS with various combinations of VBS widths, soil textures and ground surface slopes. The simulation results indicate that annual direct runoff decreases with wider VBS and the removal efficiency of pollutants generally decrease with steeper slopes. The removal efficiency of sediment is not significantly different with VBS widths. For gentle and medium slopes($10^{\circ}$, $20^{\circ}$), the removal efficiency of TOC and TN is not significantly different with VBS widths. As for a steep slope($30^{\circ}$), however, the removal efficiency of TOC and TN increases with narrower VBS. The removal efficiency of TP is generally high except for medium and steep slope of sandy loam where the removal efficiency of TP increases with wider VBS. This result of TP is contrary to the results of TOC and TN due to the adsorption characteristics of phosphorus associated with fine sediment particles. It is expected that CAMEL can be used for evaluating the effectiveness of VBS to reduce non-point source pollution discharges.

A Study on the Thermal Characteristics of Jeju type Ground Heat Exchanger for Ground Source Heat Pump System applied to Jeju Island (제주도에 설치된 지열 열펌프 시스템용 제주형 지중열교환기의 열특성 연구)

  • Kim, Min-Jun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.2
    • /
    • pp.32-38
    • /
    • 2020
  • This study summarizes test methods and evaluation methods for examining the thermal characteristics of Jeju-type ground heat exchangers (GHXs) installed on Jeju Island, and analyzes the ground temperature and thermal characteristics of ground heat exchangers installed in various regions by using thermal response tests (TRT). Jeju Island is composed of volcanic rock layers, and the groundwater flow is well developed. A Jeju-type GHX can be installed up to 30 m from groundwater level after drilling a borehole. The ground heat exchanger has a structure in which several pipes are inserted into the borehole. In order to examine the characteristics of the Jeju-type GHX, tests were conducted on ground heat exchangers installed in four places on Jeju Island (Pyoseon, Jeju, Namwon, and Hallym). As a result of the analysis of the Jeju-type ground heat exchanger, the ground circulating water temperature stabilized according to the heat injection, depending on the installed location, and was formed within one to three hours. The ground heat exchanger capacity in Hallym was highest at 73.4 kW (cooling) and 82.8 kW (heating), and the Jeju-type calculation was lowest at 34.1 kW (cooling) and 23.3 kW (heating).

Evaluation of Low or High Permeability of Fractured Rock using Well Head Losses from Step-Drawdown Tests (단계양수시험으로부터 우물수두손실 항을 이용한 단열의 고.저 투수성 평가)

  • Kim, Byung-Woo;Kim, Hyoung-Soo;Kim, Geon-Young;Koh, Yong-Kwon
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.10 no.1
    • /
    • pp.1-11
    • /
    • 2012
  • The equation of the step-drawdown test "$s_w=BQ+CQ^p$" written by Rorabaugh (1953) is suitable for drawdown increased non-linearly in the fractured rocks. It was found that value of root mean square error (RMSE) between observed and calculated drawdowns was very low. The calculated $C$ (well head loss coefficient) and $P$ (well head loss exponent) value of well head losses ($CQ^p$) ranged $3.689{\times}10^{-19}{\sim}5.825{\times}10^{-7}$ and 3.459~8.290, respectively. It appeared that the deeper depth in pumping well the larger drawdowns due to pumping rate increase. The well head loss in the fractured rocks, unlike that in porous media, is affected by properties of fractures (fractures of aperture, spacing, and connection) around pumping well. The $C$ and $P$ value in the well head loss is very important to interpret turbulence interval and properties of high or low permeability of fractured rock. As a result, regression analysis of $C$ and $P$ value in the well head losses identified the relationship of turbulence interval and hydraulic properties. The relationship between $C$ and $P$ value turned out very useful to interpret hydraulic properties of the fractured rocks.

A STUDY ON THE SAFETY ANALYSIS OF ROCK FILL DAM (1) (필댐의 안정성 해석 연구 (1))

  • HoWoongShon;DaeKeunLee
    • Journal of the Korean Geophysical Society
    • /
    • v.6 no.3
    • /
    • pp.165-177
    • /
    • 2003
  • The purpose of this paper is to analyze the behavior and to study the safety evaluation of the Unmun Dam located in Cheongdo-Gun of GyeongBuk Province, Korea. For this purpose, soil analyses including boring data, geophysical surveys were conducted. In this paper, especially many geophysical methods were adopted to configure out the subsurface situation of dam. Applied geophysical methods were: 1) electric resistivity survey, 2) high frequency magnetotelluric (HFMT) survey, 3) ground penetrating radar (GPR) survey, 4) seismic refraction survey, 5) seismic cross-hole tomography survey, and 6) high frequency impedance (ZHF) survey. Each of geophysical surveys were analyzed and joint analyses between geophysical surveys were also performed to deduce the more reliable subsurface information of Dam by using the features and characteristics of each geophysical survey. Since many defects, such as gravel and weathered rock blocks in the dam core, and lots of amounts of leakage, by boring analyses were found, reinforcement by compaction grouting system (CGS) has been conducted in some range of dam. Some geophysical data and data of geotechnical gauges were also used to confirm the effects of reinforcement. Electric resistivity, EM, GPR, ZHF, seismic refraction and seismic tomography surveys show that left side of dam is weak, which means the possibility of existence of gravel, rock block, water and cavities in the core of dam. This result coincides with the boring data. Especially, electric survey after reinforcement shows that even the right side of the dam has been deformed by the strong pressure during the reinforcement itself. As a conclusion, some problems in the dam found. Especially, the dam near spillway shows the high possibility of leakage. It should be pointed out that only the left side of he dam has not a leakage problem. As a whole, the dam has problems of weakness, because of unsatisfactory construction. It is strongly recommended that highly intensive monitoring is required.

  • PDF

The Relationship between Health Related Physical Fitness, Depression, and Quality of Life of the Elderly (노인의 건강체력과 우울, 삶의 질 관계 : 인지기능을 매개변수로)

  • Chun, Myung-Up;Choi, Jae-Won;Kang, Sung-Goo;Yoo, Ha-Na;Lee, Kyung-Ha
    • Journal of the Korea Convergence Society
    • /
    • v.10 no.12
    • /
    • pp.387-397
    • /
    • 2019
  • The purpose of this study is to analyze the relationship between health related physical fitness, cognitive function, depression and quality of life variables of elderly people in a comprehensive way based on quantitative evaluation. The subjects of this study were 385 people who voluntarily participated in the elderly welfare center in Gyeonggi and Seoul the elderly people. As for the data collection methods, were measured the characteristics, depression and quality of life, cognitive function questionnaires along with measures of lower and upper body strength, dynamic equilibrium and agility, total endurance and grip strength. As a result, the first was a statistically significant correlation between integrated health of the elderly, cognitive function, quality of life and depression. Second, the analysis of cognitive function, elderly integrated health, quality of life, and depression revealed statistical significance among all variables. Third, there was the partial intervention effect of function in the quality of life and depression of the elderly.

Analysis of Website Services of Support Center for Childcare of Districts (시군구 육아종합지원센터 웹사이트 서비스 현황 분석)

  • Chung, Hoe Wook;Kim, Kyoung Mi
    • Korean Journal of Child Education & Care
    • /
    • v.18 no.2
    • /
    • pp.217-230
    • /
    • 2018
  • The purpose of this study is to investigate the consumer centered on-line services of Support Center for Childcare(SCC) of districts. For this purpose this study analyzed the 69 on-line services in websites of SCC. The materials used to evaluate the website services in this study were revised from Lee(2009)'s, Moon(2005)'s and Lee(2005)'s study. The evaluation categories are composed of information providing services, complaints handling services, online participation services, and usability services. The result of this study are as follows. First, in the aspect of information providing services, introduction to SCC, main business of SCC, and related website ranked high. Second, in the aspect of complaints handling services, complaint service board and complaint process notice ranked high. Third, in the aspect of online participation services, on-line application and reservation ranked high. Fourth, in the aspect of usability services, integrated searching, site map, and personal information protection ranked high. The results of this study showed that websites of SCC of districts tried to various services to communicate the consumers. Also the results of this study revealed the contents and problem of websites of SCC, and implied the more systematic and efficient services of SCC.

Shear Capacity Evaluation of Steel Plate Anchors Using Folded Steel Plate in AU-composite Beam (절곡 강판을 이용한 AU합성보 덮개형 강재앵커의 전단성능 평가)

  • Lim, Hwan Taek;Choi, Byong Jeong
    • Journal of Korean Society of Steel Construction
    • /
    • v.29 no.5
    • /
    • pp.389-400
    • /
    • 2017
  • Based on U-shaped composite beam, the new form of AU-composite beam were developed to create economical and efficient components reducing the cost and shortening the length of construction work. Because the U-shaped sections are open and needs to be fixed by topping concrete securely. Therefore, it is required to maintain the U-shaped sections in a structure and to work in the safe condition through construction. It also requires accessories that resist the horizontal shear force for synthesis between the top and bottom of the U-shaped section. To reinforce these shortcomings, a shear connector has been developed with various purposes of steel plate anchors. In this study, the steel plate anchors were directly tested and the shear force was evaluated by the horizontal shear force. The experiment was divided into two types, depending on the applicable deck plates. As a result of the experiment, the continuous type specimens showed greater resistance in both strength and displacement than the ones of stud anchor specimen. In discontinuous type case, due to shear simulations and simple element analysis, the less increase the ratio of width to height and the more shear strength decreased. Thus, the shear strength equation of the stud anchor was modified to suggest the new shear strength based on the testing results.