• Title/Summary/Keyword: Result Analysis and Evaluation

Search Result 5,763, Processing Time 0.046 seconds

Evaluation of Raingauge Networks in the Soyanggang Dam River Basin (소양강댐 유역의 강우관측망 적정성 평가)

  • Kim, Jae-Bok;Bae, Young-Dae;Park, Bong-Jin;Kim, Jae-Han
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2007.05a
    • /
    • pp.178-182
    • /
    • 2007
  • In this study, we evaluated current raingauge network of Soyanggang dam region applying spatial-correlation analysis and Entropy theory to recommend an optimized raingauge network. In the process of analysis, correlation distance of raingauge stations is estimated and evaluated via spatial-correlation method and entropy method. From this correlation distances, respective influencing radii of each dataset and each methods is assessed. The result of correlation and entropy analysis has estimated correlation distance of 25.546km and influence radius of 7.206km, deducing a decrease of network density from $224.53km^2$ to $122.47km^2$ which satisfy the recommended minimum densities of $250km^2$ in mountainous regions(WMO, 1994) and an increase of basin coverage from 59.3% to 86.8%. As for the elevation analysis the relative evaluation ratio increased from 0.59(current) to 0.92(optimized) resulting an obvious improvement.

  • PDF

An Empirical Research on Location Suitability Evaluation System for Public Rental Logistics Space (공공형 임대물류공간 입지적정성 평가체계에 관한 실증 연구)

  • Ahn, Jaeseong;Lee, Seungji;Kim, Taegyun;Lee, Hyeonjoo
    • Land and Housing Review
    • /
    • v.11 no.2
    • /
    • pp.15-24
    • /
    • 2020
  • In recent years, market access is expected to become more important in logistics location selection. In addition, it is necessary to support logistics functions for small and medium-sized enterprises. In this study, we propose a location suitability evaluation system for public rental logistics spaces. The location selection and evaluation system of the public rental logistics space proposed in this study is composed of large (5), medium (10), and small (20) indicators. The 1st class were five factors: market factors, economic factors, transportation factors, site factors, policy and social factors, and the 2nd classifications per the 1st class, and the 3rd class for each 2nd class. After deriving the relative importance of each indicator through AHP for experts, it was verified by utilizing GIS analysis for virtual candidates in the metropolitan area. As a result of the trial application, it was evaluated that it could be applied with realistic results. In addition, it was confirmed that it is possible to apply evaluation indicators using spatial data constructed in Korea, and to use the evaluation indicators, it is necessary to perform various spatial analysis and processing tasks on raw data.

A Study on Image Evaluation consequent on Lighting Environment in time of reading in Learning Space (학습공간에서의 독서 행위 시 조명환경에 따른 이미지평가 연구)

  • Lee, Jin-Sook;Park, Ji-Young;Seo, Eun-Ji
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.9
    • /
    • pp.1-9
    • /
    • 2015
  • The aim of this study is to deduce color temperature and illuminance by conducting the preference & affective evaluation consequent on illuminance change of ambient light in case of the lighting method of ambient light mixed with task light in time of reading which is visual work action among the action in learning space. As a result of the prior survey on preferred lighting method in time of the act of reading targeting 20 experts before doing evaluation, the method of lighting mixed with ambient light and task light was found to be the highest. Such a result is analyzed to be attributable to the fact that the less the difference in illuminance of nearby space and work surface because of the mixed method of lighting, the less the glare, which makes a reader feels easy and concentrate on reading. On the basis of descriptive statistics of evaluation results and impact analysis by category, this study recommends the application of combinations of ambient light illuminance ranging from 40lx to 100lx with color temperature of 5500~6000K in case of the method of lighting mixed with general light and task light.

Numerical Study on Human Model's Shape and Grid Dependency for Indoor Thermal Comfort Evaluation (실내 온열쾌적성 평가를 위한 인체 모델링 및 격자특성에 대한 수치해석적 연구)

  • Park, J.H.;Seo, J.W.;Choi, Y.H.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.210-217
    • /
    • 2011
  • Recently, research on evaluating thermal comfort by using CFD has been vigorously active. This research evaluates not only distribution of temperature and air flow analysing but also thermal comfort in indoor space by applying human model. But research of human model's shape, Grid characteristic and turbulence model has not yet been studied. In this paper, human model's shape, physical characteristic of variable Grid, and change of turbulence model has been studies by CFD. In this study. FLUENT is used for analysis and PMV(predicted Mean Vote), PPD(Predicted Percentage Dissatisfied) and EHT(Equivalent Homogeneous Temperature} are used for evaluation and comparison of thermal comfort. As a result, it shows that shape of CSP and lattice features does not affect on global flow field or evaluation on PMV, PPD. However, it demonstrates more precise result from evaluation of thermal comfort by equivalent temperature when it used detailed human model considering prism grid.

  • PDF

A Development of Soundness Evaluation Index for Poor Appearance Distribution Concrete Poles (외관불량 배전용 콘크리트전주 건전도 평가지표 개발)

  • Wong, Yoon-Chan
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.9
    • /
    • pp.35-44
    • /
    • 2014
  • This study was to secure the safety of poor appearance distribution concrete poles effectively and to reduce the replacement costs of them by developing a soundness evaluation index. The researcher of this study investigated poor appearance types of concrete pole, collected 53 of test samples, and tested pole strength. As a result of strength test, only 17 percent of poor appearance concrete poles were below 2.0 of safety factor spec. As results of multiple regression analysis, it is verified that surface air void, horizontal crack, net-shaped crack, elapsed year, vertical crack, and deterioration in concrete compressive strength have statistically negative effects on safety factor of concrete poles in a significant level. The researcher set up a soundness evaluation index by using multiple regression equation, and suggested that poor appearance concrete poles should be replaced or reinforced only in case of soundness evaluation score of 150 or above.

Proposed Development and Evaluation System for Existing Standardized Waterproof Technology Assessment Methods(Production technology, maintenance evaluation) (표준화된 방수기술 평가기법 개발 및 평가체계 구축 (생산기술, 유지관리 평가 중심))

  • Song, Je-Young;Seo, Hyun-Jae;Choi, Eun-Kyu;Lee, Jung-Hun;Kim, Byoungil;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.11a
    • /
    • pp.235-236
    • /
    • 2019
  • Waterproofing materials and construction methods have been developed and applied to various construction sites since the past. However, there many cases where the waterproofing performance is not satisfactory, leading to continuous water leakage. It has been observed that a key reason for this is because waterproofing method and material selection is not optimized in terms of the appropriate application area and environmental degradation factors. This paper proposes that future selection of waterproofing methods should consider the following evaluation criteria; 1) waterproof performance evaluation according to site conditions, 2) evaluation of construction method, 3) manufacturing and maintenance of waterproofing systems.

  • PDF

A Study on the Design Characteristics Evaluation of Ubiquitous Element in the Library (도서관에서의 유비쿼터스 요소의 디자인 특성 평가 연구)

  • Hwang, Ji-Eun;Nam, Kyung-Sook
    • Korean Institute of Interior Design Journal
    • /
    • v.24 no.3
    • /
    • pp.137-145
    • /
    • 2015
  • Ubiquitous technology is currently being introduced to libraries at the fastest speed as compared to other spaces. However, the introduction of ubiquitous technology to the existing analog space is causing problems despite such intelligence of libraries as the design standards for ubiquitous spaces have not been arranged yet. This researcher analyzed and evaluated the characteristics of design from the ubiquitous aspect of the ubiquitous environment-oriented libraries that are still at their initial stage. The subjects for this study were the National Library of Korea, Myongji University Bangmok Library, and Yonsei University Library. The definition and characteristics of the ubiquitous environment libraries were examined through literature review and the standards for design analysis were derived by analyzing previous studies. Case analyses were conducted to evaluate the design elements in the ubiquitous environment libraries based on the field observation, photographing, and interviews with managers. As a result, functionality, safety, cognition and convenience were derived based on the investigation and analysis of previous studies; informativeness, playfulness, security, and simplicity which are the design characteristics were found. As a result of the case studies, while functionality and safety are met in most of the standards for design analysis, universality was very low. Care for minorities is need in a library as it is a space used by many unspecified individuals.

Laboratory/Field evaluation and calibration method of low-cost PM sensor for indoor PM2.5, PM10 measurement (실내 미세먼지 측정을 위한 저가형 PM 센서의 실험실/현장 평가 및 보정 방법)

  • Doheon, Kim;Dongmin, Shin;Jungho, Hwang
    • Particle and aerosol research
    • /
    • v.18 no.4
    • /
    • pp.109-127
    • /
    • 2022
  • Recently, low-cost particulate matter (PM) sensors have been widely used in monitoring mass concentration. Maintaining the accuracy of the sensors is important and requires rigorous performance evaluation and calibration. In this study, two commercial low-cost PM sensors(LCS), Plantower PMS3003 and Plantower PMS7003, were evaluated in the laboratory and field with a reference-grade PM monitor (GRIMM 11-D). Laboratory evaluation was conducted with single/mixed particles of PSL (Poly Styrene Latex) in an acrylic chamber at 20℃ and relative humidity of 20%. Field evaluation was conducted inside a building of Yonsei University (Shinchon) from February 12 to March 31, 2022. In both evaluations, LCS measured values became different from reference measured values when the relative humidity was high or the outdoor air PM10/PM2.5 ratio was high. Based on the field evaluation, the LCS measured values were corrected through four different regression analysis models. As a result, the multivariate polynomial regression analysis model showed highest matching with the reference PM monitor (PM2.5 >0.9, PM10 >0.85). In this model, the PM10/PM2.5 ratio and relative humidity were chosen as independent variables.

A Study on the Evaluation of Carbon Neutral Housing Development through SBTool (SBTool을 활용한 탄소중립형 주거단지 평가에 관한 연구)

  • Jeon, Woo-Seon;Choi, Joon-Sung;Oh, Deog-Seong
    • KIEAE Journal
    • /
    • v.12 no.2
    • /
    • pp.83-92
    • /
    • 2012
  • Recently, many countries are tightening a variety of policies and controls with great efforts to reduce emission of GHGs(Greenhouse Gases) as concern for climate change heightens. The purpose of the study is to provide guidelines for planning and evaluate element and evaluate housing development. The elements are also assorted into 6 sections and 30 planning elements were drawn from them. It is drawn to 6 sections, 27 categories, 31 evaluation elements except cultural and perceptual aspects unrelated to planning elements from these elements. Case analysis has shown that most of planning elements were applied because these cases obtained environment-friendly certification in the country. Followings are the common characteristics. Firstly, it showed that application of planning element in all cases is excellent. Secondly, the case with excellent application of elements related with energy and application degree obtained excellent degree i environment-friendly certification in the country. Finally, application of planning elements related with renewable energy was in poor condition in all cases. With the utilization of SBTool, the evaluation results about planning elements of housing complex of Carbon emissions-reduction type showed that CASE-A obtained 11.17 points and CASE-B obtained 9.24 points. In the case of renewable energy section, it was confirmed that the evaluation doesn't work well. As a result, changes of planning elements affect environment-friendly extent. It was confirmed that accessibility to housing complex of Carbon emissions-reduction type could change. Estimated result of Amount of Carbon emission showed that annual energy consumption per each family of CASE-A is $4,269,964MJ/m^2$, as a result of which, Carbon emission is $234,815kg/m^2$. And annual energy consumption per family of CASE-B is $4,197,563MJ/m^2$, as a result of which, Carbon emission is $214,584kg/m^2$. Application of planning elements in the aspect of housing complex of Carbon emissions-reduction type shows that the level for Carbon emissions-reduction is high level. And study with assessment from the draft should be followed.

The Analysis of Service Characteristics for Subway Passengers Using The Importance-Performance Analysis(IPA) (IPA분석을 이용한 지하철 이용자 서비스 특성에 관한 연구)

  • Park, Jung-Soo;Yoon, Sang-Hoon;Bae, Gi-Mok;Kim, Tae-Ho
    • Journal of the Korean Society for Railway
    • /
    • v.10 no.4
    • /
    • pp.420-430
    • /
    • 2007
  • It is reported that many users of the subways in Seoul are not currently satisfied with the subway services. The cause of the dissatisfaction is that the qualitative items and indexes are not considered properly, and also does not diversify the evaluation items to follow the change of subway environment. Therefore in this study the evaluation items and indexes that can reflect of the subway users' characteristics are examined and synthesized. Then the characteristics of service are analyzed for the senior subway system users and junior subway system users that are classified with the cluster analysis. The result of the study is that the majority of users on subway are not satisfied the qualitative items which are safety, kindness, comfortableness, convenience excepting for punctuality and accessibility. So, if the service of subway users improve, the qualitative items is needed to consider with quantitative items.