• 제목/요약/키워드: Restorative material

검색결과 406건 처리시간 0.025초

Effect of two-phase fabrication method for the optimum fit of light-polymerized record bases

  • Huh, Jung-Bo;Kang, Min-Goo;Shin, Sang-Wan;Ryu, Jae-Jun
    • The Journal of Advanced Prosthodontics
    • /
    • 제2권3호
    • /
    • pp.102-105
    • /
    • 2010
  • PURPOSE. The aims of this study were to suggest a method of fabrication of the record base using a light-polymerized resin by applying the two-phase fabrication method for the improvement of the fit of the record base and to compare the degree of fit according to the separation site. MATERIALS AND METHODS. In the edentulous cast of maxilla, four test groups were considered. In the first, second, third, and fourth test groups (n = 12 in each group) the separation was done at 0, 5, 10, and 15 mm, respectively below the alveolar crest along the palatal plane. For the control group, the record base was made without separating the two sections. The light-body silicone material was injected into the fitting surface of the record base. It was then placed onto the cast and finger pressure was applied to stabilize it in a seated position followed by immediate placement onto the universal test device. Finally, the mass of the impression material was measured after it was removed. ANOVA was performed using the SAS program. For the post-hoc test, the Wilcoxon Rank-Sum test and the Tukey-Kramer HSD test were performed ($\alpha$ = 0.05). RESULTS. The control group and Group 3, 4 showed significant differences. The Group 3 and 4 showed significantly smaller inside gaps than the control group which was not made with the two-phase fabrication method. CONCLUSION. The two-stage polymerized technique can improve the fit of the denture base particularly when the separation was made at 10 to 15 mm from the alveolar crest.

상아질에 대한 저점도 복합레진의 자가접착에 관한 연구 (SELF-ADHESION OF LOW-VISCOSITY COMPOSITES TO DENTIN SURFACE)

  • 조태희;최경규;박상혁;박상진
    • Restorative Dentistry and Endodontics
    • /
    • 제28권3호
    • /
    • pp.209-221
    • /
    • 2003
  • The objectiveness of this study was to evaluate whether low-viscosity composite can bond effectively to dentin surface without bonding resin. The low-viscosity composites being 50wt% filler content were made by the inclusion of bonding resin of two self-etching systems(Cleafil SE Bond, Unifil Bond) varied with contents as 0, 10, 20, 30, 40, 50wt%. Exposed dentin surfaces of extracted 3rd molars are used. Dentin bond strengths were measured. The tests were carried out with a micro-shear device placed testing machine at a CHS of 1mm/min after a low-viscosity composite was filled into an iris cut from micro tygon tubing with internal diameter approximately 0.8mm and height of 1.0mm. 1 Flexural strength and modulus was increased with the addition of bonding resin. 2. Micro-shear bond strength to dentin was improved according to content of bonding resin irrespective of applying or not bonding resin in bonding procedure, and that of Clearfil SE Bond groups was higher than Unifil Bond. 3. There were no significant difference whether use of each bonding resin in bonding procedure for S-40, S-50, U-50(p>0.05). 4. In SEM examination, resin was well infiltrated into dentin after primed with self-etching primer only for S-50 and U-50 in spite of the formation of thinner hybrid layer. Low viscosity composite including some functional monomer may be used as dentin bonding resin without an intermediary bonding agent. It makes a simplified bonding procedure and foresees the possibility of self-adhesive restorative material.

치과용 아말감 충전의 임상적 고찰 -재충천의 이유 및 기간에 대한 조사보고- (A CLINICAL STUDY OF DENTAL AMALGAM RESTORATION -Reasons for replacement and duration of primary restoration-)

  • 이정석;김광주
    • Restorative Dentistry and Endodontics
    • /
    • 제6권1호
    • /
    • pp.109-114
    • /
    • 1980
  • Ease of manipulation, adequate mechanical properties, long years of experience and economical cost are the factors which have established amalgam as the most widely used material for dental restorations. But amalgam restoration may require replacement because of secondary caries, fracture, "fall-out", dimensional change, tarnish or corrosion etc.. These failures of amalgam restorations seem to arise from failures during operations rather than from the inherent shortcomings of the material itself or of the patient's mismanagement. It is anticipated that notonly number of analgam restoration, but failures will be increase after more extensive utilization of the medical insurance which began in 1977. Then authors think that it would be helpful for the development of better treatment in daily dental practice, to know the duration of amalgam restorations and the reasons for their replacement. The data for this survey was compiled from 2, 856 out-patients of the Department of Dentistry, Ewha Woman's University Hospital from January 1975 to December 1977. 260 cases among 1,718 fillings were studied, of which 205 cases both had a single reason for replacement and recognized the date of the previous filling. The results obtained were as follows; 1. Amalgam fillings were 58. 5 percent of all dental restorative materials. Of these, 15. 13 percent of the amalgam restorations had to be replaced. 2. The first reason for replacement of amalgam restorations was secondary caries (56.10%), the second was fracture (23.80%) and the third was "fall-out" (8.78%). 3. Among those amalgms requiring replacement, 52.2 percent had been in place less than 3 years, 70.7 percent within 5 years and 89.8 percent had been in place less than 10 years. Only 10.2 percent had been in place more than 10 years.

  • PDF

Glass Ionomer Cement의 접착력(接着力)에 관(關)한 실험적(實驗的) 연구(硏究) (AN EXPERIMENTAL STUDY ON THE BONDING FORCE OF GLASS IONOMER CEMENT)

  • 이명종
    • Restorative Dentistry and Endodontics
    • /
    • 제7권1호
    • /
    • pp.77-83
    • /
    • 1981
  • The purpose of this study was to observe the bonding strength between tooth surface (enamel and dentin) and restorative filling materials which are two composite resins (Clearfil and Concise) and Glass ionomer cement, after etching with 50% phoshoric acid and 37% citric acid. To measure the bonding strength in enamel, the labial surface of upper anterior tooth was cut flatly with using carborundum disk and polished with sand paper disk, and to measure in dentin, the dentin surface was prepared by grinding upper part of posterior tooth horizontally. After washing the tooth surface with water and drying with air blast, the prepared tooth surface was etched. In glass ionomer cement, 50% phosphoric acid and 37% citric acid were used, in Clearfil 40% phosphoric acid was used and in Concise, 50% phosphoric acid and 37% citric acid were used as etchant for 1 minute. After the copper band which is 5 mm in diameter and 5 mm in height was fixed on the prepared surface and each filling material was inserted into the copper band, the hooking loop was inserted into filled material in the copper band before setting to make it easily that the load is applied on the specimen. After all specimens were immersed in water at $37^{\circ}C$ for 1 week, this specimen was placed on the load cell of tensile test apparatus, and specimen was pulled at the cross-head speed of 0.8 mm per minute. The following results were obtained 1) In glass ionomer cement, the bond strength obtained by 37% citric acid was higher than one obtained by 50% phosphoric acid in enamel and dentin surfaces. The bond strength obtained in non-etched surface was much less than one by etchants in enamel and dentin surface. 2) In Clearfil, the bond strength obtained by 40% phosphoric acid was 4 times more than one obtained by non etch ant. 3) In Concise, the bond strength obtained by 50% phosphoric acid was almost same as one obtained by 37% citric acid, and the bond strength obtained by non etch ant was much less than one obtained by etchants.

  • PDF

갈륨합금과 고동 아말감 합금의 물리적 성질 비교 (COMPARISON OF THE PHYSICAL PROPERTIES BETWEEN GALLIUM ALLOY AND HIGH COPPER AMALGAM ALLOYS)

  • 김현철;이희주;허복
    • Restorative Dentistry and Endodontics
    • /
    • 제23권1호
    • /
    • pp.278-287
    • /
    • 1998
  • The purpose of this study was to compare the physical properties between high copper amalgam and gallium restorative material. In this study, the specimens for the 4 experimatal groups (Valiant, Valiant PhD, Gallium Alloy GF II. Gallium Alloy GF II triturated with some addition of alcohol) were prepared in the manner of which stated in ADA specification No.1 for amalgam alloy. And then, measured and compared the value of compressive strength. creep, and dimensional change during hardening of each sample. The results were as follows: 1. In the compressive strength, the Valiant-lathe cut type high copper amalgam-had the highest value of strength(p<0.05), and the Valiant PhD-admixed type high copper amalgam-showed the higher value of strength than the Gallium Alloy GF II(p<0.05) but had no significant difference with Gallium Alloy GF II triturated with some addition of alcohol(p>0.05). 2. In the creep. the Valiant PhD showed the highest value of creep (p<0.05), but there was no significant difference between Gallium Alloy GF II and Valiant(p>0.05). 3. In the dimensional change during hardening, no two groups were significantly different at the 0.050 level. 4. There was no significant difference between Gallium Alloy GF II and the same material which was triturated with some addition of alcohol(p>0.05).

  • PDF

Wear of 3D printed and CAD/CAM milled interim resin materials after chewing simulation

  • Myagmar, Gerelmaa;Lee, Jae-Hyun;Ahn, Jin-Soo;Yeo, In-Sung Luke;Yoon, Hyung-In;Han, Jung-Suk
    • The Journal of Advanced Prosthodontics
    • /
    • 제13권3호
    • /
    • pp.144-151
    • /
    • 2021
  • PURPOSE. The purpose of this in vitro study was to investigate the wear resistance and surface roughness of three interim resin materials, which were subjected to chewing simulation. MATERIALS AND METHODS. Three interim resin materials were evaluated: (1) three-dimensional (3D) printed (digital light processing type), (2) computer-aided design and computer-aided manufacturing (CAD/CAM) milled, and (3) conventional polymethyl methacrylate interim resin materials. A total of 48 substrate specimens were prepared. The specimens were divided into two subgroups and subjected to 30,000 or 60,000 cycles of chewing simulation (n = 8). The wear volume loss and surface roughness of the materials were compared. Statistical analysis was performed using one-way analysis of variance and Tukey's post-hoc test (α=.05). RESULTS. The mean ± standard deviation values of wear volume loss (in mm3) against the metal abrader after 60,000 cycles were 0.10 ± 0.01 for the 3D printed resin, 0.21 ± 0.02 for the milled resin, and 0.44 ± 0.01 for the conventional resin. Statistically significant differences among volume losses were found in the order of 3D printed, milled, and conventional interim materials (P<.001). After 60,000 cycles of simulated chewing, the mean surface roughness (Ra; ㎛) values for 3D printed, milled, and conventional materials were 0.59 ± 0.06, 1.27 ± 0.49, and 1.64 ± 0.44, respectively. A significant difference was found in the Ra value between 3D printed and conventional materials (P=.01). CONCLUSION. The interim restorative materials for additive and subtractive manufacturing digital technologies exhibited less wear volume loss than the conventional interim resin. The 3D printed interim restorative material showed a smoother surface than the conventional interim material after simulated chewing.

Shear bond strength of indirect composite material to monolithic zirconia

  • Sari, Fatih;Secilmis, Asli;Simsek, Irfan;Ozsevik, Semih
    • The Journal of Advanced Prosthodontics
    • /
    • 제8권4호
    • /
    • pp.267-274
    • /
    • 2016
  • PURPOSE. This study aimed to evaluate the effect of surface treatments on bond strength of indirect composite material (Tescera Indirect Composite System) to monolithic zirconia (inCoris TZI). MATERIALS AND METHODS. Partially stabilized monolithic zirconia blocks were cut into with 2.0 mm thickness. Sintered zirconia specimens were divided into different surface treatment groups: no treatment (control), sandblasting, glaze layer & hydrofluoric acid application, and sandblasting + glaze layer & hydrofluoric acid application. The indirect composite material was applied to the surface of the monolithic zirconia specimens. Shear bond strength value of each specimen was evaluated after thermocycling. The fractured surface of each specimen was examined with a stereomicroscope and a scanning electron microscope to assess the failure types. The data were analyzed using one-way analysis of variance (ANOVA) and Tukey LSD tests (${\alpha}$=.05). RESULTS. Bond strength was significantly lower in untreated specimens than in sandblasted specimens (P<.05). No difference between the glaze layer and hydrofluoric acid application treated groups were observed. However, bond strength for these groups were significantly higher as compared with the other two groups (P<.05). CONCLUSION. Combined use of glaze layer & hydrofluoric acid application and silanization are reliable for strong and durable bonding between indirect composite material and monolithic zirconia.

수종(數種) 수복물(修復物)의 색소침투(色素浸透)에 관(關)한 실험적(實驗的) 연구(硏究) (AN EXPERIMENTAL STUDY ON PENETRATION OF DYE IN FILLING MATERIALS)

  • 이명종
    • Restorative Dentistry and Endodontics
    • /
    • 제4권1호
    • /
    • pp.29-34
    • /
    • 1978
  • The purpose of this study was to measure penetration of dye stuff(5% Methylene blue, Hematoxylin, Crystal violet and Safranin-O) on silicate cement, Adaptic, Hi-pol and unfilled resin. Each filling material was mixed on the mixing pad and the mixed material was inserted with condensation force of 500gr, 1000gr and 2000gr and without condensation force into preformed glass tube (10mm in diameter and 10mm in height). The specimen was stored in the air for 24 hours, then specimen was immersed in various dye solution (5% methylene blue, hematoxin, crystal violet and safranin-O) for different period of time (l hour and 24 hours). These dye-treated specimen was cut horizontally at the middle portion and the dye penetration in cut surface was measured. Following results were obtained. 1. Pentration of various dye was excessive in silicate cement with and without Condensation force. 2. There has been no evidence of dye penetration in unfilled resin. 3. Dye penetration occurced with in 1 hour period and the extending time didn't affect the dye penetration.

  • PDF

Glass Ionomer Cement 수복물(修復物)의 표면거칠기에 관한 실험적 연구 (EXPERIMENTAL STUDIES ON THE SURFACE ROUGHNESS OF GLASS IONOMER CEMENT RESTORATIONS)

  • 김광순;이승종;이정석
    • Restorative Dentistry and Endodontics
    • /
    • 제17권1호
    • /
    • pp.166-180
    • /
    • 1992
  • One disadvantage of Glass Ionomer Cement Restoration is the difficulty in polishing. To find the appropriate polishing method, we polished the surface of Glass Ionomer Cement Restorations by 11 combination methods serially using disks shared with large-small particles and evaluated the polishing process in terms of surface roughness, surface roughness curve, and SEM findings. In addition, a visible light curing type bonding material was applied to evaluate the possible improvement in surface properties. The following results were obtained. 1. The disk surface of Glass Ionomer Cement was polished serially by disks with superfine particles, but it didn't become smooth. 2. The surface of Microfilled Composite resin became smoother as using a disk with finer particles. 3. When a visible light curing type bonding material was applied in finishing process, the surface of Glass Ionomer Cement became smooth as much as the applied matrix.

  • PDF

연마기구에 따른 심미 치아 수복재료의 표면 거칠기에 관한 비교 연구 (SURFACE ROUGHNESS OF ESTHETIC RESTORATIVE MATERIALS BY POLISHING SYSTEMS)

  • 박은혜;양규호;최남기
    • 대한소아치과학회지
    • /
    • 제30권3호
    • /
    • pp.520-529
    • /
    • 2003
  • 소아치과 임상에서 자주 사용하고 있는 심미 수복재료는 마무리와 연마 과정을 통해 내구정과 심미성이 향상된 수복물을 얻을 수 있다. 본 연구에서는 수복재료 종류에 따른 연마기구의 적합성과 사용된 연마기구 간의 효율성을 비교하고자 하였다. Z250(3M, USA), Heliomolar(Ivoclar Vivadent, USA), Dyract AP(Dentsply, USA), Fuji II LC(GC, Japan)를 이용하여 시편을 제작하고, 연마기구인 Enhance(Dentsply, USA), Sof-Lex(3M, USA), Composite(Shofu, Japan)를 적용하여 연마하였다. 각 제품마다 제작된 시편 중에 어떠한 연마 과정도 거치지 않은 5개의 시편을 대조군으로 사용하였다. 이 시편들의 표면 거칠기($R_a\;value,\;{\mu}m$)를 측정하고, 주사전자현미경으로 관찰하여 다음과 같은 결과를 얻었다. 1. 수복재료에 따른 표면 거칠기를 비교한 결과 Z250이 가장 낮은 표면 거칠기를 나타냈으나 다른 수복재료와 비교하여 유의한 차이는 없었다(p>0.05). 2. 네 가지 수복재료는 대조군에서 가장 평활한 표면을 얻었고, 모든 연마 과정은 표면 거칠기를 증가시켰다. 3. 세 가지 연마기구 중 Sof-Lex가 가장 평활한 표면을 형성하였으며, Sof-Lex와 Enhance에 의한 표면 거칠기는 유의한 차이를 보였다(p < 0.05). 4. 주사전자현미경 관찰 시 네 가지 수복재료의 대조군은 실험군에 비해 균일한 표면을 나타냈다.

  • PDF