• 제목/요약/키워드: Response loop

Search Result 666, Processing Time 0.028 seconds

A Study on the transient response in the switching regulator (스위칭 레귤레이터에 있어서 과도응답에 대한 연구)

  • Kim, Hee-Jun;Kim, Soon-Chang
    • Proceedings of the KIEE Conference
    • /
    • 1989.11a
    • /
    • pp.235-239
    • /
    • 1989
  • This paper investigated the effect of right half plane zero on the transient response in the buck-boost DC-DC converter. And it is clarified that the damping ratio decreases gradually by increases of the feedback loop gain and the regulation system of the converter becomes unstable. From the result, we obtained the stability region about the duty ratio and the output current by evaluating the feedback loop gain.

  • PDF

Locating Idle Vehicles in Tandem-Loop Automated Guided Vehicle Systems to Minimize the Maximum Response Time

  • Lee, Shiwoo
    • Industrial Engineering and Management Systems
    • /
    • v.6 no.2
    • /
    • pp.125-135
    • /
    • 2007
  • An automated guided vehicle (AGV) system is a group of collaborating unmanned vehicles which is commonly used for transporting materials within manufacturing, warehousing, or distribution systems. The performance of an AGV system depends on the dispatching rules used to assign vehicles to pickup requests, the vehicle routing protocols, and the home location of idle vehicles, which are called dwell points. In manufacturing and distribution environments which emphasize just-in-time principles, performance measures for material handling are based on response times for pickup requests and equipment utilization. In an AGV system, the response time for a pickup request is the time that it takes for the vehicle to travel from its dwell point to the pickup station. In this article, an exact dynamic programming algorithm for selecting dwell points in a tandem-loop multiple-vehicle AGV system is presented. The objective of the model is to minimize the maximum response time for all pickup requests in a given shift. The recursive algorithm considers time restrictions on the availability of vehicles during the shift.

A Lock-Time Improvement for an X-Band Frequency Synthesizer Using an Active Fast-Lock Loop Filter

  • Heo, Yun-Seong;Oh, Hyun-Seok;Jeong, Hae-Chang;Yeom, Kyung-Whan
    • Journal of electromagnetic engineering and science
    • /
    • v.11 no.2
    • /
    • pp.105-112
    • /
    • 2011
  • In phase-locked frequency synthesizers, a fast-lock technique is frequently employed to overcome the trade-off between a lock-time and a spurious response. The function of fast-lock in a conventional PLL (Phased Lock Loop) IC (Integrated Circuit) is limited by a factor of 16, which is usually implemented by a scaling of charge pumper, and consequently a lock time improvement of a factor of 4 is possible using the conventional PLL IC. In this paper, we propose a novel external active fast-lock loop filter. The proposed loop filter provides, conceptually, an unlimited scaling of charge pumper current, and can overcome conventional trade-off between lock-time and spur suppression. To demonstrate the validity of our proposed loop-filter, we fabricated an X-band frequency synthesizer using the proposed loop filter. The loop filter in the synthesizer is designed to have a loop bandwidth of 100 kHz in the fast-lock mode and a loop bandwidth of 5 kHz in the normal mode, which corresponds to a charge pumper current change ratio of 400. The X-band synthesizer shows successful performance of a lock-time of below 10 ${\mu}sec$ and reference spur suppression below -64 dBc.

Effect of Grouting Materials on Ground Effective Thermal Conductivity (그라우팅 재료가 지중 유효열전도도에 미치는 영향)

  • Sohn, Byong-Hu
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.3371-3376
    • /
    • 2007
  • The design of a ground-source heat pump system includes specifications for a ground loop heat exchanger where the heat transfer rate depends on the thermal conductivity of the ground. To evaluate this heat transfer property, in-situ thermal response tests on four vertical test boreholes with different grouting materials were conducted by adding a monitored amount of heat to water over various test lengths. By measuring the water temperatures entering and exiting the loop, water flow rate, and heat load, effective thermal conductivity values of the ground were determined. The effect of increasing thermal conductivity of grouting materials from 0.82 to 1.05 W/m$^{\circ}C$ resulted in overall increases in effective ground thermal conductivity by 25.8% to 69.5%.

  • PDF

POSITIONING MODEL OF THE AUTOMATED GUIDED VEHICLE IN LOOP LAYOUT TO MAXIMIZE THE REQUEST-CALL RESPONSE PROBABILITIES (루프레이아웃 AGVS에서의 작업요구 응답확률을 최대화 하기 위한 AGV대기 위치 결정 모형)

  • 김재연
    • Proceedings of the Korea Association of Information Systems Conference
    • /
    • 1996.11a
    • /
    • pp.199-204
    • /
    • 1996
  • It is discussed how to determine the home location of idle vehicles in an AGVS with a loop guide path in a way of maximizing the request-call response probabilities for all demand. Optimal home position is selected by solving the simultaneous equations easily. Static positioning strategy is analyzed in which a single home position is allocated to which every vehicle is routed whenever it becomes idle. The cases of unidirectional guidepath is considered only. We provide a numerical example to illustrate the search algorithm developed for the case and compare the searched optimal solutions with the others.

  • PDF

Robust Control using Observer for Brushless DC Motor (BLDC 모터의 관측자를 이용한 강인 제어)

  • Yu, Byung-Sam;Shin, Doo-Jin;Park, Eik-Dong;Huh, Uk-Youl
    • Proceedings of the KIEE Conference
    • /
    • 1999.11c
    • /
    • pp.552-554
    • /
    • 1999
  • In this paper, a robust control system with the disturbance observer is proposed for BLDC servo system. The overall control system consists of the speed controller which is implemented with PI controller and the disturbance observer with free parameters. The proposed control system is designed the command input response and the closed loop characteristics independently by using two-degrees-of-freedom concept, so it can improve the closed loop characteristics with no influence on the command input response. The effective suppression of disturbance with the observer improves the characteristics of the closed loop of the system. And also, by fluting the bandwidth of free parameters, measurement noise is considered. To verify the better performance of the proposed control system than that of the conventional PI controllers, the performance of the controller is analyzed theoretically and some simulation results are presented.

  • PDF

Optimum Parameter Determination of PLL Used in Timing Clock Recovery Circuit (타이밍 클릭 복원 회로에 사용된 PLL의 최적 파라미터 결정)

  • Ryu, Heunggyoon;ANN, Souguil
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.24 no.3
    • /
    • pp.376-380
    • /
    • 1987
  • The closed-loop transfer function of 2-nd order PLL (phase-looked loop)of which loop filter has active-lag 1-st order is found. Considering the three criteria of system performance: the transient response time of the circuit, noise bandwidth by the linear analysis and stability which uses root-locus method, the optimum value of damping factor is 1.0 and the natural frequency which depends upon the signal frequency can be determined after consideration of the trade-off relationship between the transient response time and the noise bandwidth.

  • PDF

An Application of loop-loop EM Method for Geotechnical Survey (지반조사를 위한 loop-loop 전자탐사 기법의 적용)

  • You Jin-Sang;Song Yoonho;Seo1 Soon-Jee;Song Young-Soo
    • Geophysics and Geophysical Exploration
    • /
    • v.4 no.2
    • /
    • pp.25-33
    • /
    • 2001
  • Loop-loop electromagnetic (EM) survey in frequency domain has been carried out in order to provide basic solution to geotechnical applications. Source and receiver configuration may be horizontal co-planar (HCP) and/or vertical co-planar (VCP). Three quadrature components of mutual impedance ratio for each configuration are used to construct the subsurface image. For the purpose of obtaining the model response and validating the reasonable performance of the inversion, we obtained each responses of two-layered and three-layered earth models and two-dimensional (2-D) isolated anomalous body. The response of 2-D isolated anomalous body has been calculated using extended Born approximation for the solution of 2.5-D integral equation describing EM scattering problem. As a result of the least-squares inversion with variable Lagrangian multiplier, we could construct more resolvable image from HCP data than VCP data. Furthermore, joint inversion of HCP and VCP data made better stability and resolution of the inversion. Resistivity values, however, did not exactly match the true ones. Loop-loop EM field data was obtained with EM34-3XL system manufactured by Geonics Ltd. (Canada). Electrical resistivity survey was conducted on the same line for the comparison in advance. Since the constructed image from loop-loop EM data by 2-D inversion algorithm showed almost similar resistivity distribution to that from electrical resistivity one, we expect the developed 2.5-D loop-loop EM inversion program can be applied for the reconnaissance site survey.

  • PDF

Internal Model Control of UPS Inverter using Resonance Model

  • Park J. H.;Kim D. W.;Kim J. K.;Lee H. W.;Noh T. K.;Woo J. I.
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.184-188
    • /
    • 2001
  • In this paper, a new fully digital control method for single-phase UPS inverter, which is based on the double control loop such as the outer voltage control loop and inner current control loop, is proposed. The inner current control loop is designed and implemented in the form of internal model control and takes the presence of computational time-delay into account. Therefore, this method provides an overshoot-free reference-to-output response. In the proposed scheme, the outer voltage control loop employing P controller with resonance model implemented by a DSP is introduced. The proposed resonance model has an infinite gain at resonant frequency, and it exhibits a function similar to an integrator for AC component. Thus the outer voltage control loop causes no steady state error as regard to both magnitude and phase. The effectiveness of the proposed control system has been demonstrated by the simulation and experimental results respectively.

  • PDF