• Title/Summary/Keyword: Respiratory dust

Search Result 201, Processing Time 0.025 seconds

A Health Hazard and Environmental friendly Machining of Machining Fluids (가공유제의 인체피해와 친환경 가공)

  • 김남경;김해지
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.4
    • /
    • pp.128-135
    • /
    • 2003
  • To decrease environmental damage, the development of environmental friendly fluids provides attractive alternative to the conventional fluids. In this study, the effects of harmful ingredients (Cl, S) contained in the fluids that used in grinding and cutting processes to influence on the nasal cavities of the white rats were measured indirectly. Also, the level of the environmental influence in workshops was graded through analyzing the concentration and chemical ingredients of flying-dust, which generated from the friction and combustion in the cutting process, that for analyzing how harmful the influence of particles to workers then it could be used as the basic data for improving the environment. To improve the conventional machining fluid, which can be harmful on worker's bodies and the environment, the environmental friendly machining method was suggested through analyzing each lubrication properties of vegetable fluid and used-edible oil as alternative fluid. As a result, it was known that an emulsion type fluid might be the main cause leading to some respiratory ailments. Also this paper presents the possibility to use vegetable fluid and used-edible oil as the alternative of cutting fluids.

A Case Study on Development of Fine Dust STEAM Program for Enhancing Engineering Creative Problem Solving Ability of Chinese Elementary School Students (중국 초등학생의 공학 창의적 문제해결력 향상을 위한 미세먼지 STEAM 프로그램 개발 사례 연구)

  • Quan, Hai Yan;Byun, Moon Kyoung
    • Journal of Engineering Education Research
    • /
    • v.23 no.2
    • /
    • pp.14-23
    • /
    • 2020
  • Based on the constructivist learning environments model and the learner-centered psychological principles, STEAM education program with the theme of eliminating smog was developed. Through the program, senior elementary school students will learn and apply the convergence knowledge of science, technology, engineering, arts and mathematics such as the human body's respiratory system (S), immune system (S), big data (M, T), computer programming(M), and aduino sensor utilization (E) directly to solve the problem. After expert validity testing, we found that developed program meet the standards of STEAM education program development and can develop creative thinking skills to find and solve problems in students' daily lives. In addition, this study is meaningful in providing a reference example for the development of STEAM education programs that enhance convergence knowledge in the future.

Development of Real-time Environment Monitoring System Using 3G Integrated Environmental Sensors Based on AWS (AWS기반 3G 통합환경센서 모듈을 이용한 실시간 환경 모니터링 시스템 개발)

  • Chun, Seung-Man;Lee, Seung-Jun;Yun, Jang-Kyu;Suk, Soo-Young
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.13 no.2
    • /
    • pp.101-107
    • /
    • 2018
  • As indoor pollutants such as carbon dioxide and dust mainly affect the respiratory and circulatory systems, there is an increasing need for real-time indoor / outdoor environmental monitoring. In this paper, we have developed a real - time environmental monitoring system using the cloud-based 3G integrated environmental sensor module for environmental monitoring. A highly reliable environmental information monitoring system requires various IT technologies such as infrastructure (server, commercial software, etc.), service application software, security, and authentication. A real-time environment monitoring system based on cloud service that can provide reliable service satisfying these configuration requirements is proposed and implemented. It is expected that this system can be applied to various technologies such as indoor automatic window opening/closing system based on the Internet.

Pproperties of formaldehyde and CO2 adsorption type matrix using TiO2 photocatalysis (광촉매를 활용한 흡착형 경화체의 포름알데히드 및 CO2 특성)

  • Lee, Won-Gyu;Pyeon, Su-Jeong;Kyoung, In-Soo;Lee, Sang-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.11a
    • /
    • pp.153-154
    • /
    • 2018
  • As the air pollution progresses, the pollution degree of the indoor air quality is increased, and when the pollution degree of the indoor air quality is increased, it causes respiratory diseases and skin diseases. In addition, volatile organic compounds are released from the materials used for architectural interior decoration, and volatile organic compounds are the main cause of polluting indoor air quality. In order to improve indoor air quality, we tried to secure indoor air quality pollution by using photocatalyst which has the function of decomposing harmful substances. photocatalyst is a material that promotes chemical reaction by absorbing light. The photocatalyst used in the experiment was TiO2, In this study, an adsorption type hardener for reducing volatile organic compounds was prepared by photocatalytic reaction. the formaldehyde and CO2 concentrations of the cured products were analyzed according to the TiO2 content.

  • PDF

Pore Properties of Magnesium Oxide Matrix using Red Mud and Vermiculite (버미큘라이트 및 레드머드를 활용한 산화마그네슘 경화체의 공극 특성)

  • Lim, Hyun-Ung;Lee, Won-Gyu;Lee, Sang-Soo;Song, Ha-Young
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.11a
    • /
    • pp.120-121
    • /
    • 2018
  • Radon is one of the substances that pollute the indoor air and is classified as a first-level carcinogen by the International Agency for Research on Cancer(IARC) together with asbestos, and it is reported that it can cause lung cancer. The World Health Organization(WHO) reports that lung cancer is the second leading cause of lung cancer, and 6-15% of lung cancer patients report lung cancer caused by radon. Radon occurs in cracks in concrete and aged buildings, and is detected in soil, rocks, groundwater, and so on. It is a colorless, odorless and tasteless gas which is adsorbed to dust in the air and enters through human respiratory system. This study used vermiculite (expanded vermiculite), which has excellent ion exchange ability and a large number of pores, and industrial by - product red mud which has heavy metal adsorption ability, in order to adsorb radon. A matrix capable of adsorbing radon was prepared, and the characteristics of each material were compared and analyzed.

  • PDF

An Implementation of Inside Environment Purifying System Using ZIGBEE (ZIGBEE를 이용한 실내 환경 정화 시스템 구현)

  • Seo, Hyung-Yong;Lee, Jae-Heung
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • v.9 no.2
    • /
    • pp.447-450
    • /
    • 2005
  • This paper describes an implementation of system based on ZIGBEE wireless communication technique to prevent for diseases of skin ailments and respiratory ailments as sensing the air pollutions that breaks out in the inside and purifying. ZIGBEE wireless communication technique has features - low battery consumption, low cost, acceptance of the maximum 256 node and simple protocol structure of below 32Kbyte. Hardware platform is implemented by using ATmega128L in ATmel corporation and 2.4GHz RF-IC CC2420 in Chipcon corporation and dust sensor(GP2Y1010AU) and gas sensor(GSBT11) that confirm degree of inside air pollution for ZIGBEE wireless communication technique.

  • PDF

Black Lung Disease Among Coal Miners in Asia: A Systematic Review

  • Kurnia A. Akbar;Kraiwuth Kallawicha
    • Safety and Health at Work
    • /
    • v.15 no.2
    • /
    • pp.123-128
    • /
    • 2024
  • Background: Coal miners are highly prone to occupational health risks, such as black lung disease. This study aims to assess the prevalence of black lung disease and the factors associated with black lung disease among coal miners in Asia. Method: This systematic review, conducted according to the Preferred Reporting Items for Systematic Reviews and Meta-Analysis guidelines, searched through the scientific literature of the following databases: EBSCO, ScienceDirect, PubMed, and Scopus. We selected articles that studied black lung disease among coal miners from 48 countries in Asia and were published between 2014 and 2023. Article quality was evaluated using the Critical Appraisal Skills Program. Result: The seven articles that we review studied a total of 653,635 coal miners from various types of coal mines from three countries in Asia. Of these miners, 59,998 experienced black lung disease. Black lung disease is prevalent among 9.18% of coal miners in Asia, which is approximately four times higher than the worldwide prevalence. Common factors that influence black lung disease in Asia include age, years of dust exposure, smoking, drinking, working types, and sizes of mines, type of mines, respiratory functions, spirometry parameters, tenure, lack of attention to occupational health, inefficient surveillance, and weak occupational health service. Conclusion: Although the prevalence of black lung disease among coal miners in Asia is considerably high, it can be addressed through effective prevention measures, monitoring, control, and case reporting.

The Application of Impulse Oscillometry (IOS) in the Workers Who had been Exposed to Inorganic Dust Induced Early Airway Obstruction (Impulse Oscillometry (IOS)를 이용한 무기분진 노출자에서의 기도폐쇄 연구)

  • Lee, Joung-Oh;Lee, You-Lim;Choi, Byung-Soon;Lee, Hong-Ki
    • Tuberculosis and Respiratory Diseases
    • /
    • v.71 no.6
    • /
    • pp.431-437
    • /
    • 2011
  • Background: We tried to examine the small airway diseases which can be found early, in workers exposed to inorganic dusts. This is measured in normal breath by using the impulse oscillometry (IOS). Methods: The Pulmonary function test (forced vital capacit [FVC], forced expiratory volume in one second [$FEV_1$], forced expiratory flow between 25% and 75% of vital capacity [$FEF_{25-75}$]), IOS resistance (Rrs at 5, 10, 15, 20, 25, 35 Hz) and reactance (Xrs at 5, 10, 15, 20, 25, 35 Hz) were measured for 454 workers. The subjects were classified into 173 workers of normal (38.1%) and 281 patients with pneumoconiosis (61.9%). Results: There were significant differences between normal and patients with FVC ($3.82{\pm}0.61$ vs. $3.53{\pm}0.56L$), $FEV_1$ ($2.67{\pm}0.63$ vs. $2.35{\pm}0.48L$), and $FEF_{25-75}$ ($1.88{\pm}0.95$ vs. $1.47{\pm}0.80L/sec$) between groups (p<0.05). And as for IOS, there was no significant difference in resistance (Rrs) (p>0.05), and there were significant differences between normal and patients with reactance (Xrs) 15 Hz ($0.003{\pm}0.05$ vs. $-0.006{\pm}0.04kPa/L/s$), 20 Hz ($0.043{\pm}0.05$ vs. $0.031{\pm}0.04kPa/L/s$), and 35 Hz ($0.141{\pm}0.05$ vs. $0.131{\pm}0.05kPa/L/s$) between groups (p<0.05). Conclusion: We could find out that 15 Hz, 20 Hz, and 35 Hz values of reactance were significantly influenced by pneumoconiosis. When usefulness and reproducibility to carry out the IOS are considered, it is thought that in future work will be required to draw the reference values for normal Korean persons.

Change of Volume of Isoflow in Pneumoconiosis Patients with Small Opacity (소음영 진폐증 환자에서의 등기류용량(Volume of Isoflow)의 변화)

  • Oh, Sang-Yong;Kim, Jee-Won;Jung, Chang-Young;Kim, Kyung-Ah;Yun, Im-Goung
    • Tuberculosis and Respiratory Diseases
    • /
    • v.40 no.5
    • /
    • pp.540-547
    • /
    • 1993
  • Backgrounds: The measurement of volume of isoflow has been considered as a sensitive test for detecting small airway diseases showing normal pulmonary function in a routine pulmonary function test. To evaluate the functions of small airway among dust exposed workers, the changes of volume of isoflow were measured and its applicability of managing early stage pneumoconiosis patients was studied. Method: The subjects were 67 male, pneumoconiosis with small opacity and FEV1>80%, FEV1/FVC>75% in spirometry and the controls were 20 male, no dust-exposed office workers. The maximal epiratory volume curves after inhalation of indoor air and $He-O_2$ gas mixtures were measured and ${\Delta}V_{max50},\;{\Delta}V_{max75},\;V_{iso}V/VC$ between the dust exposed and control workers were compaired. Results: 1) There were no significant differences between two group in ${\Delta}V_{max50}$ and ${\Delta}V_{max75}$. But the ratio of $V_{iso}V/VC$ of the subjects was siginificantly higher than that of the control (p<0.01). This study confirms that $V_{iso}V/VC$ is a very useful index in early detection of small airway dysfunction. 2) The ratio of $V_{iso}V/VC$ of the subjects was signigicantly different between only smoker group and mixed group(smoker and nonsmoker). It suggestes that smoking is an important cousative factor of small airway dysfunction. 3) As the profusion of the chest X-ray increased, the rartio of $V_{iso}V/VC$ increased, but no significant difference of $V_{iso}V/VC$ was found between categories of pneumoconiosis. The categories of pneumoconiosis and small airway dysfunction may not be related. 4) No significant relationship was established between the duration of work and the ratio of $V_{iso}V/VC$. Conclusions : It is concluded that the measurement of $V_{iso}V/VC$ is useful to detect small airway dysfuction of early stage pnuemoconiosis patents with small opacities but showing normal pulmonary function in a routine pulmonary function test.

  • PDF

Air Pollution and Its Effects on E.N.T. Field (대기오염과 이비인후과)

  • 박인용
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1972.03a
    • /
    • pp.6-7
    • /
    • 1972
  • The air pollutants can be classified into the irritant gas and the asphixation gas, and the irritant gas is closely related to the otorhinolaryngological diseases. The common irritant gases are nitrogen oxides, sulfur oxides, hydrogen carbon compounds, and the potent and irritating PAN (peroxy acyl nitrate) which is secondarily liberated from photosynthesis. Those gases adhers to the mucous membrane to result in ulceration and secondary infection due to their potent oxidizing power. 1. Sulfur dioxide gas Sulfur dioxide gas has the typical characteristics of the air pollutants. Because of its high solubility it gets easily absorbed in the respiratory tract, when the symptoms and signs by irritation become manifested initially and later the resistance in the respiratory tract brings central about pulmonary edema and respiratory paralysis of origin. Chronic exposure to the gas leads to rhinitis, pharyngitis, laryngitis, and olfactory or gustatory disturbances. 2. Carbon monoxide Toxicity of carbon monoxide is due to its deprivation of the oxygen carrying capacity of the hemoglobin. The degree of the carbon monoxide intoxication varies according to its concentration and the duration of inhalation. It starts with headache, vertigo, nausea, vomiting and tinnitus, which can progress to respiratory difficulty, muscular laxity, syncope, and coma leading to death. 3. Nitrogen dioxide Nitrogen dioxide causes respiratory disturbances by formation of methemoglobin. In acute poisoning, it can cause pulmonary congestion, pulmonary edema, bronchitis, and pneumonia due to its strong irritation on the eyes and the nose. In chronic poisoning, it causes chronic pulmonary fibrosis and pulmonary edema. 4. Ozone It has offending irritating odor, and causes dryness of na sopharyngolaryngeal mucosa, headache and depressed pulmonary function which may eventually lead to pulmonary congestion or edema. 5. Smog The most outstanding incident of the smog occurred in London from December 5 through 8, 1952, because of which the mortality of the respiratory diseases increased fourfold. The smog was thought to be due to the smoke produced by incomplete combustion and its byproduct the sulfur oxides, and the dust was thought to play the secondary role. In new sense, hazardous is the photochemical smog which is produced by combination of light energy and the hydrocarbons and oxidant in the air. The Yonsei University Institute for Environmental :pollution Research launched a project to determine the relationship between the pollution and the medical, ophthalmological and rhinopharyngological disorders. The students (469) of the "S" Technical School in the most heavily polluted area in Pusan (Uham Dong district) were compared with those (345) of "K" High School in the less polluted area. The investigated group had those with subjective symptoms twice as much as the control group, 22.6% (106) in investigated group and 11.3% (39) in the control group. Among those symptomatic students of the investigated group. There were 29 with respiratory symptoms (29%), 22 with eye symptoms (21%), 50 with stuffy nose and rhinorrhea (47%), and 5 with sore thorat (5%), which revealed that more than half the students (52%) had subjective symptoms of the rhinopharyngological aspects. Physical examination revealed that the investigated group had more number of students with signs than those of the control group by 10%, 180 (38.4%) versus 99 (28.8%). Among the preceding 180 students of the investigated group, there were 8 with eye diseases (44%), 1 with respiratory disease (0.6%), 97 with rhinitis (54%), and 74 with pharyngotonsillitis (41%) which means that 95% of them had rharygoical diseases. The preceding data revealed that the otolaryngological diseases are conspicuously outnumbered in the heavily polluted area, and that there must be very close relationship between the air pollution and the otolaryngological diseases, and the anti-pollution measure is urgently needed.

  • PDF