• Title/Summary/Keyword: Respiration signal

Search Result 155, Processing Time 0.024 seconds

Augmentation of respiratory muscle activities in preterm infants with feeding desaturation

  • Kwon, Dong Rak;Park, Gi Young;Jeong, Ji Eun;Kim, Woo Taek;Lee, Eun Joo
    • Clinical and Experimental Pediatrics
    • /
    • v.61 no.3
    • /
    • pp.78-83
    • /
    • 2018
  • Purpose: Frequent desaturation due to immature incoordination of suck-swallow-breathing in preterm infants can influence multiple organs such as the heart, lungs, and brain, which can then affect growth and development. Most notably in preterm infants, feeding desaturation may even affect pulmonary function during gavage feeding. Because respiratory muscle activities may reflect the work required during respiration, we evaluated the differences in these activities between full-term and preterm infants with feeding desaturation, and investigated the correlations with clinical variables. Methods: Nineteen preterm infants with feeding desaturation (group 1) and 19 age-matched full-term infants (group 2) were evaluated. Oromotor function was evaluated using video recording. The root-mean-square (RMS) envelope of the electromyography signal was calculated to quantify the activities of muscles involved in respiration. The differences in RMS between both groups and the correlation with clinical variables including gestational age (GA), birth weight (BW), and Apgar scores (AS) at 1 and 5 minutes after birth were evaluated. Results: The RMS values of the diaphragm (RMS-D) and rectus abdominis (RMS-R) were significantly greater in group 1 compared to group 2, and the 1- and 5-min AS were significantly lower in group 1 compared to group 2. RMS-D and RMS-R were inversely correlated with GA, BW, 1- and 5-min AS in all infants. Conclusion: This study showed that respiratory muscle activities were augmented during feeding in preterm infants compared to full-term infants. Additionally, respiratory muscle activities were inversely correlated with all clinical variables.

Differences of EEG and autonomic responses between olfactory stimuli with orange and valeric acid in human (오렌지향과 valeric acid향에 대한 뇌파와 자율신경계반응에 나타난 후각 감성)

  • 백은주;이윤영;이배환;문창현;이수환
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 1997.11a
    • /
    • pp.75-79
    • /
    • 1997
  • The present study was designed to investigate whether there is a consistint changes in the signals from the central and autonomic nervous systim due to olfactory stimulation. The olfactory stimuli were 0.6% orange and 2.5% valeric acid and the stimuli through the olfactory stimulator soth controlled consistint flow, controlled concentration, and saturated with vapour to prevent drying the nasal mucosa. A room air blunk served as the control stimulus, EEG was recorede from 4channels according to the international 10-20 systim. Additionally, ECG, EOG, heart rate, skin conductance and resputation were recorded comtinuously. The fast Fourier transform analysis of EEG waves was analysed with the power spectra. Averaged power spectra were computed for the following frequency bands ; delta(0-4.5Hz), theta (4.5-7Hz), alphal(7-9.5Hz), alpha2 (9.5-12.5Hz) and beta(12.5-30Hz). Withthe results of the subjective sensibility test for the ordor, the orange was related to pleasant and familiar and the valeric acid was realted to snpleasant and bothersome. There is the difference between orange and valeric acid in alphal at PG2-A2 channel. While the unpleasant stimuli seem to be increased in alphal, alpha2 and beta waves at all channels. Also, the heart rate, galvaric skin resistance seem to be decreased by pleasant stimuli and thd unpleasant stimuli shdwed the opposite. In respiration, respiration rate had been declinig tendency, and input/output ampoitued and duration showed an upward trend by olfactory stimulation with orange, while opposite by valeric acid. In conclusion, the consistent EEG changes and the autonomic responses suggests the possibilities of the subjective signal of human sensibility.

  • PDF

Reproducibility Evaluation of Deep inspiration breath-hold(DIBH) technique by respiration data and heart position analysis during radiation therapy for Left Breast cancer patients (좌측 유방암 환자의 방사선치료 중 환자의 호흡과 심장 위치 분석을 통한 Deep inspiration breath-hold(DIBH) 기법의 재현성 평가)

  • Jo, Jae Young;Bae, Sun Myung;Yoon, In Ha;Lee, Ho Yeon;Kang, Tae Young;Baek, Geum Mun;Bae, Jae Beom
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.297-303
    • /
    • 2014
  • Purpose : The purpose of this study is reproducibility evaluation of deep inspiration breath-hold(DIBH) technique by respiration data and heart position analysis in radiation therapy for Left Breast cancer patients. Materials and Methods : Free breathing(FB) Computed Tomography(CT) images and DIBH CT images of three left breast cancer patients were used to evaluate the heart volume and dose during treatment planing system( Eclipse version 10.0, Varian, USA ). The signal of RPM (Real-time Position Management) Respiratory Gating System (version 1.7.5, Varian, USA) was used to evaluate respiration stability of DIBH during breast radiation therapy. The images for measurement of heart position were acquired by the Electronic portal imaging device(EPID) cine acquisition mode. The distance of heart at the three measuring points(A, B, C) on each image was measured by Offline Review (ARIA 10, Varian, USA). Results : Significant differences were found between the FB and DIBH plans for mean heart dose (6.82 vs. 1.91 Gy), heart $V_{30}$ (68.57 vs. $8.26cm^3$), $V_{20}$ (76.43 vs. $11.34cm^3$). The standard deviation of DIBH signal of each patient was ${\pm}0.07cm$, ${\pm}0.04cm$, ${\pm}0.13cm$, respectively. The Maximum and Minimum heart distance on EPID images were measured as 0.32 cm and 0.00 cm. Conclusion : Consequently, using the DIBH technique with radiation therapy for left breast cancer patients is very useful to establish the treatment plan and to reduce the heart dose. In addition, it is beneficial to using the Cine acquisition mode of EPID for the reproducibility evaluation of DIBH.

Signal Analysis for Detecting Abnormal Breathing (비정상 호흡 감지를 위한 신호 분석)

  • Kim, Hyeonjin;Kim, Jinhyun
    • Journal of Sensor Science and Technology
    • /
    • v.29 no.4
    • /
    • pp.249-254
    • /
    • 2020
  • It is difficult to control children who exhibit negative behavior in dental clinics. Various methods are used for preventing pediatric dental patients from being afraid and for eliminating the factors that cause psychological anxiety. However, when it is difficult to apply this routine behavioral control technique, sedation therapy is used to provide quality treatment. When the sleep anesthesia treatment is performed at the dentist's clinic, it is challenging to identify emergencies using the current breath detection method. When a dentist treats a patient that is under the influence of an anesthetic, the patient is unconscious and cannot immediately respond, even if the airway is blocked, which can cause unstable breathing or even death in severe cases. During emergencies, respiratory instability is not easily detected with first aid using conventional methods owing to time lag or noise from medical devices. Therefore, abnormal breathing needs to be evaluated in real-time using an intuitive method. In this paper, we propose a method for identifying abnormal breathing in real-time using an intuitive method. Respiration signals were measured using a 3M Littman electronic stethoscope when the patient's posture was supine. The characteristics of the signals were analyzed by applying the signal processing theory to distinguish abnormal breathing from normal breathing. By applying a short-time Fourier transform to the respiratory signals, the frequency range for each patient was found to be different, and the frequency of abnormal breathing was distributed across a broader range than that of normal breathing. From the wavelet transform, time-frequency information could be identified simultaneously, and the change in the amplitude with the time could also be determined. When the difference between the amplitude of normal breathing and abnormal breathing in the time domain was very large, abnormal breathing could be identified.

A Study Concerning Analysis of Arousal State of locomotive Engineering During Operating Train (열차 운행 중인 기관사의 각성상태 분석에 관한 연구)

  • Yang, Heui-Kyung;Lee, Jeong-Whan;Lee, Young-Jae;Lee, Jae-Ho;Lim, Min-Gyu;Baek, Jong-Hyen;Song, Yong-Soo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.6
    • /
    • pp.891-898
    • /
    • 2012
  • The study for the passenger's comfortableness of vehicles and the arousal of car drivers has been done widely. On the other hand, there are few studies for the locomotive engineers. Human error means that the mistakes made by human, recently it receives attention in the field of safety engineering and human engineering. Comparing the operating condition of train with car, because of the simplification of the visual stimulus, the arousal level on the train goes down easily. The arousal level down makes judgement down, the accident risk from human error is getting bigger. In this study, we measured bio-signals(ECG, EDA, PPG, respiration and EEG) from 6 locomotive engineers to evaluate their arousal state while they operated the train. Also we recorded the 3 axes acceleration signal showing the vibration state of train. Also, the existence of tunnels were simultaneously measured. At the station section where the train speed goes down, the size of vector's sum decreases because of reduced vibration. Beta component in EEG tends to increase at the entering point of each station and tunnel. It is due to the arousal reaction and tension growth. The mean SCR(skin conductance response) was more increased in neutral section. As the button control movement (body movement) increases in the neutral section, it is appeared that SCR increase. RR interval tends to gradually increase during train operation for 1 hour 40 minutes. However, It tends to sharply decrease at the stop station because strong concentration needed to stop train on the exact point. The engineer's arousal reaction can be checked through analysing the bio-signal change during train operation. Therefore, if this analysing result is adopted to the sleepiness prevention caution system, it will be useful for the safety train operation.

Snoring Detection Sleep Pillow (코골이 감지 수면베개)

  • Tran, Minh;Ahn, Dohyun;Park, Jaehee
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.20 no.2
    • /
    • pp.105-110
    • /
    • 2019
  • People sleep about one-third of their lives and their sleep time varies according to age. Adult usually sleep 8 hours a day. However, that dose not guarantee good sleep. The cause of this is due to sleep disorders like snoring and sleep apnea. In this paper, the smart pillow for detecting snoring among sleep disorders is investigated. This pillow consists of two microphones located on the left and right side of the pillow. For simple detecting, the snoring signal was converted into the pulse using a peak detection circuit. The decision of the snoring occurrence was by pulse duration. The accuracy of the snoring detection was about 97%. The research results show that the smart pillow can be use to detect the snoring during sleeping.

A study on a target-tracking and noncontact type biosignal measurment system Using IR-Radar and Pan-Tilt system (원격 비접촉식 목표 추적형 생체신호측정시스템에 관한 연구)

  • Choi, Kwang-Wook;Kim, Cheol-Sung;Yang, Chul-Seung;Lee, Jeong-Gi
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.9
    • /
    • pp.2237-2242
    • /
    • 2014
  • As Single households increases for reason of communication development, extending human life, there are many problems occuring all over the world. In order to solve this problem with an invasion of privacy and manintain a healthy life, this paper suggest non-contact type bio-signal measurement system using IR-Radar, displacement sensor and Pan-Tilt system. The proposed system can increse the distance of measured respiration from 1m to over 8m, which is comprised of two IR-Radar for location tracking, one displacement sensor for non-contact type bio-signal measurement and one stepping motor drive system. The proposed system is verified through experiments and were confirmed the possibility.

Smart Air Conditioning Service Using Bio-signal and Emotional Lighting (생체신호와 감성조명을 이용한 스마트 에어컨 서비스)

  • Kim, Jong-Min;Ryu, Gab-Sang
    • Journal of the Korea Convergence Society
    • /
    • v.12 no.9
    • /
    • pp.31-37
    • /
    • 2021
  • Recently, in the market of home appliances, the technical differentiation of products using convergence technology has been receiving a lot of response to satisfy consumer demand. However, air-conditioner products are an area that requires research and development in the early stages of convergence technology. In this paper, it is developed that a non-contact bio-signal(respiration, movement) collection technology using IR-UWB(Impulse-Radio Ultra Wideband) technology, which controls the air-conditioner direction according to the user's location and also monitors sleep to provide an optimal sleep environment. In addition, emotional lighting and ASMR are developed to provide a comfortable and emotional place of life. Finally, based on the developed convergence technology, we develop intelligent smart air-conditioning services for the convenience of daily life and a comfortable resting space.

A Study On The Classification Of Driver's Sleep State While Driving Through BCG Signal Optimization (BCG 신호 최적화를 통한 주행중 운전자 수면 상태 분류에 관한 연구)

  • Park, Jin Su;Jeong, Ji Seong;Yang, Chul Seung;Lee, Jeong Gi
    • The Journal of the Convergence on Culture Technology
    • /
    • v.8 no.6
    • /
    • pp.905-910
    • /
    • 2022
  • Drowsy driving requires a lot of social attention because it increases the incidence of traffic accidents and leads to fatal accidents. The number of accidents caused by drowsy driving is increasing every year. Therefore, in order to solve this problem all over the world, research for measuring various biosignals is being conducted. Among them, this paper focuses on non-contact biosignal analysis. Various noises such as engine, tire, and body vibrations are generated in a running vehicle. To measure the driver's heart rate and respiration rate in a driving vehicle with a piezoelectric sensor, a sensor plate that can cushion vehicle vibrations was designed and noise generated from the vehicle was reduced. In addition, we developed a system for classifying whether the driver is sleeping or not by extracting the model using the CNN-LSTM ensemble learning technique based on the signal of the piezoelectric sensor. In order to learn the sleep state, the subject's biosignals were acquired every 30 seconds, and 797 pieces of data were comparatively analyzed.

Analysis of changes in dose distribution due to respiration during IMRT

  • Shin, Jung-Suk;Shin, Eun-Hyuk;Han, Young-Yih;Ju, Sang-Gyu;Kim, Jin-Sung;Ahn, Sung-Hwan;Kim, Tae-Gyu;Jeong, Bae-Kwon;Park, Hee-Chul;Ahn, Young-Chan;Choi, Doo-Ho
    • Radiation Oncology Journal
    • /
    • v.29 no.3
    • /
    • pp.206-213
    • /
    • 2011
  • Purpose: Intensity modulated radiation therapy (IMRT) is a high precision therapy technique that can achieve a conformal dose distribution on a given target. However, organ motion induced by respiration can result in significant dosimetric error. Therefore, this study explores the dosimetric error that result from various patterns of respiration. Materials and Methods: Experiments were designed to deliver a treatment plan made for a real patient to an in-house developed motion phantom. The motion pattern; the amplitude and period as well as inhale-exhale period, could be controlled by in-house developed software. Dose distribution was measured using EDR2 film and analysis was performed by RIT113 software. Three respiratory patterns were generated for the purpose of this study; first the 'even inhale-exhale pattern', second the slightly long exhale pattern (0.35 seconds longer than inhale period) named 'general signal pattern', and third a 'long exhale pattern' (0.7 seconds longer than inhale period). One dimensional dose profile comparisons and gamma index analysis on 2 dimensions were performed. Results: In one-dimensional dose profile comparisons, 5% in the target and 30% dose difference at the boundary were observed in the long exhale pattern. The center of high dose region in the profile was shifted 1 mm to inhale (caudal) direction for the 'even inhale-exhale pattern', 2 mm and 5 mm shifts to exhale (cranial) direction were observed for 'slightly long exhale pattern' and 'long exhale pattern', respectively. The areas of gamma index >1 were 11.88 %, 15.11%, and 24.33% for 'even inhale-exhale pattern', 'general pattern', and 'long exhale pattern', respectively. The long exhale pattern showed largest errors. Conclusion: To reduce the dosimetric error due to respiratory motions, controlling patient's breathing to be closer to even inhaleexhale period is helpful with minimizing the motion amplitude.