• Title/Summary/Keyword: Respiration rate

Search Result 879, Processing Time 0.028 seconds

Development of Hospice Oriented Medical Record (HOMR) for Cancer Patients (호스피스 암 환자를 위한 의무기록지의 개발)

  • Seng, Jeong-Won;Hong, Sung-Moon;Kim, Si-Wan;Kim, Jeong-A;Park, Joon-Chul;Kim, Su-Hyun;Seo, Min-Jeong;Her, Sin-Hoe;Kim, Hye-Won;Hong, Myung-Ho;Choi, Youn-Seon
    • Journal of Hospice and Palliative Care
    • /
    • v.7 no.1
    • /
    • pp.49-63
    • /
    • 2004
  • Purpose: The Hospice Oriented Medical Record (HOMR) was developed for assessing the pain and symptoms of terminal cancer patients. Methods and Results: The HOMR consists of an instruction for users and 2 assessment pages which include the graph showing vital signs (temperature, blood pressure, pulse, respiration rate and pain score), current problem lists, performance status, laboratory data, pain characteristics and management, sedation score, associated symptoms and drug side effects, etc. Pilot study was performed in the inpatient Hospice Care Unit in Guro Hospital, Korea University Medical Center. Because an one-week progress data was recorded in HOMR as a flow sheet, the patient's condition and pain control status could be seen at a glance. Conclusion: The HOMR is useful for assessing the terminal cancer patients because it is simple and convenient to use. Further research is needed before it can be universally used in the clinical settings.

  • PDF

Selection of Quality Indicator to Determine the Freshness of Muskmelon (Cucumis melo L.) during Distribution (머스크멜론의 유통 중 신선도 판정을 위한 품질 지표 선정)

  • Kim, Ji-Young;Kwon, Ki-Hyun;Gu, Kyung-Hyung;Kim, Byeong-Sam
    • Food Science and Preservation
    • /
    • v.18 no.6
    • /
    • pp.824-829
    • /
    • 2011
  • This study was conducted to identify quality indicators to determine freshness of muskmelon during distribution. The correlation between each quality characteristic and organoleptic preference was analyzed after examining weight loss, firmness, soluble solid content, chromaticity, and respiration rate of and changes in the organoleptic characteristics during storage at 0, 10, 20 and $30^{\circ}C$ after harvesting. The correlation between weight loss and preference according to the storage temperature was shown to be significant (p<0.01). The correlation between firmness and preference was shown to be highly significant (R=0.74, 0.78, 0.88, and 0.83 at 0, 10, 20, and $30^{\circ}C$) under all temperature conditions, and was shown to be especially highly significant (p<0.01) when the temperature was high. In the case of storage at 20 and $30^{\circ}C$, a significant correlation between soluble-solid content and preference was shown. Therefore, it is right to apply the change in weight loss and firmness that indicated a high correlation with organoleptic preference as a quality indicator at all storage temperatures.

Quality Changes in Fresh-Cut Potato (Solanum tuberosum var. Romano) after Low-Temperature Blanching and Treatment with Anti-Browning Agents (저온 blanching 및 갈변저해물질의 처리에 따른 최소가공 감자의 저장 중 품질변화)

  • Hwang, Tae-Young;Jang, Ji-Hyun;Moon, Kwang-Deog
    • Food Science and Preservation
    • /
    • v.16 no.4
    • /
    • pp.499-505
    • /
    • 2009
  • Quality changes in fresh-cut potatoes during storage at $4^{\circ}C$ after treatment with low-temperature blanching and antibrowning agents were studied. Fresh-cut potatoes were treated by dipping for 1.5 min in a browning inhibitor solution containing 0.5% (w/v) ascorbic acid, 0.5% (w/v) citric acid, 0.5% (w/v) sodium chloride, 0.1% (w/v) trehalose, and 0.005% (w/v) biotin, at $60^{\circ}C$, with subsequent cooling for 1.5 min and storage at $4^{\circ}C$. The browning properties of fresh-cut potatoes were examined by measurement of polyphenol oxidase (PPO) activity and total phenolic content. Changes in quality attributes over a 14-day period were assessed in terms of titratable acidity, pH, water-soluble solid level, and gas analysis at $4^{\circ}C$. During storage, PPO activity increased, with the lowest activity seen after about 7 days of storage. Treatment with antibrowning solution at $4^{\circ}C$ increased visual sensory attributes during storage. Low-temperature blanching in distilled water more effectively inhibited browning compared with exposure to browning inhibitor solution, as assessed after 7 days of storage. Fresh-cut potatoes respired aerobically after different treatments during storage at $4^{\circ}C$.

Effect of biomass pyrolysis liquid on the quality characteristics of 'Xiangshui' pears (Pyrus ussuriensis) during storage (바이오매스 열분해액이 '향수'배의 저장 중 품질특성에 미치는 영향)

  • Zhang, Xian;Jiang, Gui-Hun;Li, Fan-Zhu;Eun, Jong-Bang
    • Food Science and Preservation
    • /
    • v.24 no.3
    • /
    • pp.374-380
    • /
    • 2017
  • The quality characteristics of 'Xiangshui' pears (Pyrus ussuriensis) treated with different concentrations of biomass pyrolysis liquid (BPL) during storage at $25^{\circ}C$ were investigated. The weight of 'Xiangshui' pears treated with BPL declined at a slower rate than that of the control. The rot index of BPL-treated 'Xiangshui' pears decreased with increasing storage times, and treatment with 20-fold-diluted BPL resulted in the lowest rot index after storage for 12 days. The total acid content of 'Xiangshui' pears treated with 20-fold-diluted BPL was 0.19%, and was the highest after storage for 12 days. After storage for 12 days, the total sugar content of 'Xiangshui' pears treated with 20-fold-diluted BPL was 7.19%; this was significantly higher than that of the control, but not significantly different from that of pears treated with other BPL dilutions. The vitamin C content of 'Xiangshui' pears showed a decreased trend, and pears treated with 20-fold-diluted BPL had a vitamin C content of 2.21 mg/100 g after storage for 12 days and showed the least decline compared to other treatments. In addition, respiration in 'Xiangshui' pears was effectively inhibited by treatment with BPL. In conclusion, BPL treatment exerts a protective effect on the quality of 'Xiangshui' pears during storage, with 20-fold-diluted BPL being the most effective.

Evaluation of Respiration Reproducibility of Chest General X-ray Examination using Self-made Respiratory Synchronization Device (자체 제작한 호흡 동기화 장치를 통한 흉부 일반촬영 검사의 호흡 재현성 평가)

  • Kwon, Oh-Young;Lee, Chang-Hun;Yong, Keum-Ju;Jin, Seon-Hui;Jung, Da-Bin;Heo, Yeong-Cheol
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.7
    • /
    • pp.1049-1056
    • /
    • 2021
  • The purpose of this study was to develop a respiratory synchronization device for X-ray (X-RSD) to increase the reproducibility of inspiration when examining the Chest X-ray of a patient who difficulty in breathing coordination. The X-RSD was self-made using an air pressure sensor and air was injected by connecting a ventilator to the mannequin for CPR. At this time, the amount of injected air was quantified using the SkillReporting device. After placing the X-RSD on the chest of the mannequin, the amount of air was tested in 6 steps from 200 to 700 cc by 100 cc increased. For the accuracy evaluation, the sensitivity of X-RSD was measured by repeating a total of 80 measurements, and the sensitivity was 100%, and very precise results were obtained. After that, the images examined while viewing the X-RSD of the chest lateral examination and the images obtained by the blind examination were compared and evaluated. The lung volume of X-RSD was larger than that of the blind test, and the deviation was smaller. Overall, the use of X-RSD can help with chest X-ray examination of patients who have difficulty in cooperating, and it is thought that it will be possible to contribute to the reduction of exposure dose by reducing the repeat rate of general X-ray examinations.

Relationship between Breathing Pattern Disorder and Joint Position Sense in Patients with Chronic Low Back Pain (만성요통환자의 호흡패턴이상과 관절위치감각의 관계)

  • Cho, Byungyun;Yoon, Junggyu
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.7 no.2
    • /
    • pp.1-10
    • /
    • 2019
  • Purpose : To investigate the relationship between breathing pattern disorder and joint position error (JPE) in patients with chronic low back pain (CLBP). Methods : Thirty nine patients with CLBP participated. End-tidal $CO_2$ and respiration rate (RR) were measured using a capnography. Breathing-hold time (BHT) and Nijmegen Questionnaire (NQ) were investigated. Thoracic excursion was measured with a cloth tape measurement technique. Joint position error were measured using a small laser point mounted on a lightweight headband. they were asked to relocate the head, after the neck movement on the horizontal plane. Pearson 's test was used for correlation analysis between respiratory variables and JPE in patients with CLBP. Independent t-test was used to verify the difference between thoracic and diaphragm breathing pattern in patients with CLBP. The significance level was set at 0.05. Results : There was a significant correlation between JPE (LR) and JPE (RR, EX) (r=.639, r=.813) (p<.001) and a low negative correlation with end-tidal $CO_2$ (r=-.357) (p<.05). There was a significant correlation between RR and JPE (EX) (r=.750) (p<.001). There was a low correlation between JPE (EX) and NQ (r=.333) (p<.05). There was a somewhat high negative correlation between NQ and thoracic excursion (r=-.528) (p<.001). There was a somewhat high negative correlation between thoracic excursion and JPE (LR, RR, EX) (r=-.470, r=-.484, r=-.602) (p<.001). There were no significant differences in the RR, BHT, NQ, and thoracic excursion between the thoracic and diaphragmatic breathing (p>.05). There was a significant difference in the JPE (EX), end - tidal $CO_2$, and VAS values between the thoracic and diaphragm breathing (p<.05). Conclusion : There was a correlation between JPE (EX) and NQ in patients with CLBP, and correlation between thoracic excursion and JPE (LR, RR, EX) and NQ. There was a significant difference in the JPE (EX), end-tidal $CO_2$ level, and VAS value in the comparison of thoracic breathing and diaphragm breathing. The results showed that breathing patterns and JPE were related to each other.

Imaging Diagnosis of Dilated Cardiomyopathy in a Maltese Dog

  • An, Soyon;Park, Junghyun;Mok, Jinsu;Kim, Areum;Han, Changhee;Song, Joong Hyun;Yu, Dohyeon;Hwang, Tae Sung;Lee, Hee-Chun
    • Journal of Veterinary Clinics
    • /
    • v.38 no.3
    • /
    • pp.163-168
    • /
    • 2021
  • A 6-year-old, spayed female, Maltese dog with tachypnea and dry cough was presented to Gyeongsang National University Veterinary Medical Teaching hospital. On physical examination, its respiration rate was 132 per minute. Decreased partial pressure of oxygen, partial pressure of carbon dioxide, and hyperlactatemia were found on arterial blood gas analysis. Its diastolic blood pressure was 80 mmHg. Auscultation revealed arrhythmia. Electrocardiogram revealed P pulmonale, P mitrale, and ventricular premature complexes. Thoracic radiographs revealed mild enlargement of both atrium and moderate enlargement of the left ventricular. There was also a moderate alveolar pattern in the right and caudal part of the left cranial lung lobe. Two-dimensional echocardiography showed enlargement of generalized four chambers without remarkable findings of valvular degeneration. M-mode echocardiography showed decreased left ventricular fractional shortening and enlarged left ventricular internal diameter at both end-systolic and end-diastolic. Color-flow Doppler imaging revealed eccentric turbulent flow starting below the left ventricular outflow tract and extending into the left atrium during systole. Spectral Doppler recordings revealed a high velocity flow through the mitral, tricuspid, aorta, and pulmonic regurgitation. Restrictive transmitral flow revealed high E-wave velocity, short E-wave deceleration time, and reduced A-wave velocity. There was also low ejection velocity thorough left ventricular out tract flow. Based on echocardiographic examination, dilated cardiomyopathy was the tentative diagnosis. The dog was medicated with inotropes, angiotensin converting enzyme inhibitor, and diuretics. At the 10-day following-up, the dog died suddenly. This report describes echocardiographic diagnosis and prognosis of dilated cardiomyopathy rarely reported in small breed dogs.

Revision of 22-year Records of Atmospheric Baseline CO2 in South Korea: Application of the WMO X2019 CO2 Scale and a New Baseline Selection Method (NIMS Filter) (지난 22년간 한반도 이산화탄소 배경농도 재산정 연구 - WMO/GAW 척도 변경과 NIMS 온실가스 배경농도 산출기법을 중심으로 -)

  • Seo, Wonick;Lee, Haeyoung;Kim, Yeon-Hee
    • Atmosphere
    • /
    • v.31 no.5
    • /
    • pp.593-606
    • /
    • 2021
  • The Korea Meteorological Administration/National Institute of Meteorological Sciences (KMA/NIMS) has monitored atmospheric CO2 at Anmyeondo (AMY) World Meteorological Organization (WMO) Global Atmosphere Watch Programme (GAW) regional station since 1999, and expanded its observations at Jeju Gosan Suwolbong station (JGS) in the South and at Ulleungdo-Dokdo stations in the East (ULD and DOK) since 2012. Due to a recent WMO CO2 scale update and a new filter (NIMS) to select baseline levels at each station, the 22 years of CO2 data are recalculated. After correction for the new CO2 scale, we confirmed that those corrected records are reasonable within the compatibility goal (±0.1 ppm of CO2) between KMA/NIMS and National Oceanic and Atmosphereic Administration (NOAA) flask-air measurements with the new scale. With the new NIMS filter, CO2 baseline levels are now more representative of the large-scale background compared to previous values, which contained large CO2 enhancements. Atmospheric CO2 observed in South Korea is 4 to 8 ppm greater than the global average while the amplitude of seasonal variation is similar (10~13 ppm) to the amplitude averaged over a comparable latitude zone (30°N-60°N). Variations in CO2 growth rate are also similar, increasing and decreasing similar to global values, as it reflects the net balance between terrestrial respiration and photosynthesis. In 2020, atmospheric CO2 continued increasing despite the COVID-19 pandemic. Even though fossil emission was reduced (around -7% globally), we still emitted large amounts of anthropogenic CO2. Overall, since CO2 has large natural variations and its source was derived from not only fossil fuel but also biomass burning, the small fossil emission reduction could not affect the atmospheric level directly.

Relationship between Breathing Pattern Disorder and Pain in Patients with Chronic Low Back Pain (만성요통환자의 호흡패턴이상과 통증과의 상관관계)

  • Lim, Chae-Gil
    • Journal of Korea Entertainment Industry Association
    • /
    • v.14 no.4
    • /
    • pp.355-363
    • /
    • 2020
  • To investigate the relationship between breathing pattern disorder and pain in patients with chronic low back pain(CLBP). One hundred four patients were measured the End-tidal CO2(EtCO2) and respiration rate(RR) using capnography. Also, The Breathing-hold time(BHT), Nijmegen Questionnaire(NQ), and Thoracic excursion examinated. There was a significant correlation between EtCO2 and BHT, thoracic excursion(r=.302, r=.281)(p<.01), and a low negative correlation with RR, VAS(r=-.253, -200)(p<.05). There was a significant correlation between NQ and RR(r=.237)(p<.05). There was a low correlation between thoracic excursion and VAS(r=-.370)(p<.01). There was a significant difference in the EtCO2, RR, BHT, thoracic excursion, and VAS between the thoracic and diaphragm breathing pattern(p<.05). There were no significant differences in the NQ(p>.05). There was a correlation between EtCO2 and BHT, thoracic excursion, RR, VAS in patients with CLBP. In addition, There was a correlation between RR and NQ, thoracic excursion, and VAS. As a result, it was found that there is a close relationship between breathing pattern disorder and pain. There was a significant difference in the EtCO2 level, RR, BHT, thoracic excursion and VAS value in the comparison of thoracic breathing pattern and diaphragm breathing pattern. This is a meaningful result of suggesting a breathing pattern treatment approach in the rehabilitation and pain management of chronic low back pain patients in clinical practice.

Comparison of Recovery Coefficients for Correction of Reduced SUV by Partial Volume Effect and Organ Movements in PET/CT Images (PET/CT 영상의 부분체적효과와 장기의 움직임으로 인해 감소된 SUV의 보정을 위한 회복계수의 비교)

  • Kim, Youngjae;Park, Hoon-Hee;Lee, Joo-Young;So, Young;Lee, Jeong-Woo
    • Journal of radiological science and technology
    • /
    • v.45 no.3
    • /
    • pp.241-248
    • /
    • 2022
  • In this study, a recovery coefficient (RC) calculation was conducted that can correct the underestimation of the standardized uptake value (SUV) due to the partial volume effect (PVE) through phantom measurements and formulas. The experiment was conducted using a dynamic phantom capable of implement cranio-caudal movement at a respiratory rate of 15 times per minute along with the measured phantom experiment of the stopped state, and the RC of the moving state is calculated and compared. Ingenuity TF (Philips Healthcare, Netherland) was used as a positron emission tomography/computed tomography (PET/CT) device. PET-CT Phantom (Biodex Medical System, USA) was used as a phantom for measurement. A phantom image in a stationary state was acquired, and a moving phantom image was acquired using the AZ-733V Respiratory Phantom (Anzai Medical Co, Japan) capable of breathing movement in the cranio-caudal direction under the same acquisition parameters. For RC calculation, the sphere maximum radioactivity concentration and the background mean radioactivity concentration of the acquired images were measured, and the initially determined sphere and background radioactivity concentrations were calculated. The calculated RC was 0.08 to 0.72. The size of sphere smaller, it was confirmed that the RC reduced. And the RC in the moving state reduced than in the stationary state. As a result of this study, the change of the RC was confirmed according to the size of spheres and the phantom moving. Using the RC derived by implement movement of breathing with the respiratory phantom, it is possible to considering correction of underestimated SUV by the partial volume effect of PET images and the patient movements.