• Title/Summary/Keyword: Resonant mode

Search Result 642, Processing Time 0.036 seconds

Active Noise Control of Reverberant Sound Field Using the Multi-Channel Adaptive Algorithm (다채널 적응 알고리즘을 이용한 잔향 음장에서의 능동소음제어에 관한 연구)

  • Kim, H.S.;Sohn, D.G.;Oh, J.E.
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.3 no.6
    • /
    • pp.23-29
    • /
    • 1995
  • In this study, Active noise controlis implemented with single channel and multi-channel adaptive algorithm in 3 dimensional reverberant enclosure sound. field, which occurrs in complicated acoustic mode. First, for the one case excited with the resonant frequency of an enclosure, a target of control and the other cases excited with band-pass filtered random noise(100~400Hz), it is implemented to control reducing interior noise of enclosure with single channel and realtime multi-channel adaptive algorithm for global noise reduction in enclosure.

  • PDF

A Study on Analysis and Design of HVC Embedded High Frequency Transformer for Microwave Oven (Inverter 구동 Microwave Oven용 HVC 내장형 고주파변압기의 해석 및 설계에 관한 연구)

  • Park, K.H.;Cho, J.S.;Mok, H.S.;Choe, G.H.
    • Proceedings of the KIEE Conference
    • /
    • 2001.04a
    • /
    • pp.293-296
    • /
    • 2001
  • A conventional power supply to drive a microwave oven has ferro-resonant transformer and high voltage capacitor(HVC). Though it is simple, transformer is bulky, heavy and has low-efficiency. To improve this defect, a high frequency inverter type power supply has been investigated and developed in recent years. But, because of additional control circuit and switching device, inverter-type power supply is more expensive than conventional one. In this study, The design procedure of a novel HVC embedded high frequency transformer is proposed for down-sizing and cost reduction of Inverter-type power supply. Also, equivalent circuit mode] is derived by FEM analysis and impedance measurements. And the operation of proposed HVC embedded transformer is verified by simulations and experimental results.

  • PDF

Multiplication of Displacements of the Langevin Type Piezoelectric Transducer using Various Shapes of Horns

  • Park, Tae-Gone;Kim, Myong-Ho;Park, Min-Ho
    • Transactions on Electrical and Electronic Materials
    • /
    • v.5 no.2
    • /
    • pp.61-65
    • /
    • 2004
  • Bolt-tightened Langevin type vibrators using longitudinal mode of bar were designed and fabricated. In order to amplify the displacement of the tip of the vibrators, stacked ceramics were used and five different shapes of the horns were designed and jointed. Resonant frequencies and vibration characteristics of vibrators and horns were analyzed by ANSYS(finite element analysis computer program), and the displacements of tips of the horns were measured. As results, when the numbers of the stacked ceramics were increased, the displacements of the tips were increased and the driving voltages were decreased. Step l horn (BLT-St1) showed maximum displacement of 36.92 $\mu\textrm{m}$ at 36.7 ㎑ with 45 V$\sub$rms/ and 0.11 A. The displacement amplification ratio was about 5.2. But, the stress of step l horn was concentrated on intersection, where two diameters meet. To lessen the stress, step3 shaped hem is recommended.

The Resonant Flyback Converter for DLP Projector (DLP 프로젝터용 공진형 플라이백 컨버터)

  • Park, Woo-Chol;Yoo, Byoung-Seon;Kim, Chang-Sun
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.986-987
    • /
    • 2006
  • 준공진형 플라이백 컨버터를 사용하여 Full HD급 DLP 프로젝터용 컨버터 설계에 대해 고찰하였다. 소형 경량화 시키기 위한 방법으로 Full Mode Packaging 형태로 절연설계에 유리하게 하였고, Shidegn사의 MR4040을 사용하여 부분공진 스위칭 동작에 의해 고효율 저노이즈를 실현하였다. 중부하 시 스위칭 주파수는 35KHz, 경부하시 스위칭 주파수는 최대 200KHz이고 입력전압 AC $90{\sim}264$[v], 출력전력 66W급의 컨버터을 제작하였으며 측정된 효율은 최고 93% 이다.

  • PDF

Sliding Conditions at the Interface between Soil and Underground Structure (지반과 지하구조물 경계의 미끄러짐 조건에 관한 연구)

  • 김대상
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.6 no.1
    • /
    • pp.7-11
    • /
    • 2002
  • By focusing on the resonant vibration mode of soil-underground structure system, this paper obtained dynamic soil stiffness and easy sliding conditions at the interface between soil and underground structure. Multi-step method is employed to isolate two primary causes of soil-structure interaction. Mohr-Coulomb criterion is used to determine the threshold level of the sliding. To find out the conditions the interface slides easily, parametric studies are performed about the factors governing sliding, which are the size and location of underground structures, ground condition, the configuration of surface deposit and interface friction coefficients.

Experimental investigations of higher-order springing and whipping-WILS project

  • Hong, Sa Young;Kim, Byoung Wan
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.6 no.4
    • /
    • pp.1160-1181
    • /
    • 2014
  • Springing and whipping are becoming increasingly important considerations in ship design as container ships increase in size. In this study, the springing and whipping characteristics of a large container ship were investigated through a series of systematic model tests in waves. A multi-segmented hull model with a backbone was adopted for measurement of springing and whipping signals. A conversion method for extracting torsion springing and whipping is described in this paper for the case of an open-section backbone. Higher-order springing, higher-mode torsion responses, and the effects of linear and nonlinear springing in irregular waves are highlighted in the discussion.

Stability Analysis of Cracked Cantilever Beam With Tip Mass and Follower Force (끝단질량과 종동력을 가진 크랙 외팔 보의 안정성 해석)

  • Yoon, Han-Ik;Son, In-Soo;Ahn, Tae-Su
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2007.04a
    • /
    • pp.99-104
    • /
    • 2007
  • In this paper a dynamic behavior(natural frequency) of a cracked cantilever beam with tip mass and follower force is presented. In addition. an analysis of the flutter and buckling instability of a cracked cantilever beam subjected to a follower compressive load is presented. Based on the Euler-Bernouli beam theory, the equation of motion can be constructed by using the Lagrange's equation. The vibration analysis on such cracked beam is conducted to identify the critical follower force for flutter ins stability based on the variation of the first two resonant frequencies of the beam. Besides. the effect of the crack's intensity and location on the flutter follower force is studied. The crack section is represented by a local flexibility matrix connecting two undamaged beam segments. The crack is assumed to be in the first mode of fracture and to be always opened during the vibrations.

  • PDF

The characteristics of two-electrod-ceramic filter using energy trapping effect (에너지 트래핑 효과를 이용한 이중전극 세라믹 필터의 특성)

  • Kim, Won-Seok;Park, Gi-Yub;Song, Jun-Tai
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1419-1421
    • /
    • 1994
  • The method of suppression based on the principle of energy trapping effect is very effective at high frequency. In this paper, We intended to get resonant frequency and bandpass filer characteristics in appling to vibration mode of PZT-4 and PZT-8 using trapped energy phenomenon. First, we theoretically analyzed a piezoelectric ceramic filter characteristics changing the thickness of ceramic plate, electrode spacing and distance between the two pairs of electrodes. We also experimentally investigated characteristics of ceramic filter made.

  • PDF

A High Efficiency and High Power Chopper Circuit QRAS using Soft Switching under Test Evaluation at 8kW

  • Tsuruta Yukinori;Kawamura Atsuo
    • Journal of Power Electronics
    • /
    • v.6 no.1
    • /
    • pp.1-7
    • /
    • 2006
  • This paper is a record of the study on a high efficiency and high power chopper based on the new soft switching method QRAS (Quasi~resonant Regenerating Active Snubber) designed for a Fuel Cell Electric Vehicle (FCEV). This power chopper is basically proposed for 25kHz soft switching. To confirm the practicality and effectiveness of the converter, the fabrication of a prototype-model using IGBTs was completed. Additionally, a 8kW rating test, a light load test, a current discontinuous mode test and a stable operation resonance test was completed. The circuit geometry, the basic operation, and the 8kW one-tenth-prototype test results are reported with a $97.5\%$ efficiency measurement.

THREE LEVEL SINGLE-PHASE SINGLE STAGE AC/DC RESONANT CONVERTER WITH A WIDE OUTPUT OPERATING VOLTAGE RANGE (넓은 출력 전압제어범위를 갖는 3레벨 단상 단일전력단 AC/DC 컨버터)

  • Marius, Takongmo;Lee, G.W;Kim, M.J;Kim, E.S
    • Proceedings of the KIPE Conference
    • /
    • 2018.07a
    • /
    • pp.434-435
    • /
    • 2018
  • In this paper, a single-phase single-stage three-level AC/DC converter with a wide controllable output voltage is presented. It integrates a PFC converter and a three level DC/DC converter into one. The proposed converter operates at a fixed frequency and provides a wide controllable output voltage ($200V_{dc}-430V_{dc}$) with high efficiencies over a wide load range. In addition, the input boost inductors operate in a discontinuous mode to improve the input power factor. Moreover, all the switching devices operate with ZVS, and the converter's THD is small especially at full load. The feasibility of the proposed converter is verified with experimental results of a 1.5kW prototype.

  • PDF