• Title/Summary/Keyword: Resonant inverter

Search Result 601, Processing Time 0.023 seconds

Analysis of high-frequency resonant Inverter character using efficient ozonizer (고효율 오존생기용 고주파 공진형 인버터의 특성 해석)

  • Kim, Young-Hoon;Hwang, Young-Min;Noh, In-Bae;Kim, Young-Bin;Heo, Tae-Won;Woo, Jung-In
    • Proceedings of the KIEE Conference
    • /
    • 2002.11d
    • /
    • pp.246-248
    • /
    • 2002
  • This paper presents a high-frequency voltage source inverter for silent corona discharge ozonizer application, which is characterized by the power control based on pulse density modulation (PDM). The PDM inverter produces either a square -wave ac-voltage state or a zero-voltage state at its ac terminals to control the average output voltage under constant do voltage and operating frequency. This results in a wide range of power control in the silent corona discharge load with a strong nonlinear characteristics. And proposed addition circuit for maintain discharge on the center of the airgap. In this paper, schemed equivalent electric circuit of the discharge electrode for simulation. Finally, the effectiveness of this discharge tube character of silent corona ozonizer is investigated in the simulation results.

  • PDF

The Power Supply for High Frequency Induction Heating by using the Current Resonance (전류공진을 이용한 고주파 유도가열용 전원장치)

  • Ra, B.H.;Lee, E.Y.;Song, D.H.;Suh, K.Y.;Lee, H.W.
    • Proceedings of the KIEE Conference
    • /
    • 2002.11d
    • /
    • pp.263-266
    • /
    • 2002
  • In this paper, It is indicating that an issues of the conventional boost converter for high frequency induction heating. To improve those issues, it is proposed, simulated and analyzed that the current resonant circuit, simulated. As the result, we knew that the proposed circuit has a good point to improve the waveform of input current and to make high efficiency. On the other side, in the inverter for the high current power supply, it is proposed that the high frequency inverter of the half bridge topology, be done the circuit analysis to extract the optimal circuit parameter. It is making sure of the soft switching operating by the inductor to reverse parallel connected on the inverter main switch, decreasing the surge voltage when the switch is turn-off by compulsion, and repressing the switch current and bringing the high current amplitude operation by the multi resonance.

  • PDF

A Study on Pulse Power Suppuy for Microwave Oven Using HVC Embedded High Frequency Transformer (HVC 내장형 고주파변압기를 이용한 Microwave Oven용 펄스전원장치에 관한 연구)

  • Park K.H.;Cho J.S.;Jung B.H.;Mok H.S.;Park H.B.
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.584-588
    • /
    • 2001
  • A conventional power supply to drive a microwave oven has ferro-resonant transformer and high voltage Capacitor(HVC). Though it is simple, transformer is bulky, heavy and has low-efficiency. To improve this defect a high frequency inverter type power supply has been investigated and developed in recent years. But, because of additional control circuit and switching device, inverter-type power supply is more expensive than conventional one. In this study, A new pulse power supply for Microwave Oven using novel HVC embedded high frequency transformer is proposed for down-sizing, cost reduction, and efficiency emprovement of Inverter type power supply. Also, equivalent circuit model is derived by impedance measurements. And the operation of proposed pulse power supply is verified by simulations and experimental results.

  • PDF

Modal Analysis of Resonance and Stable Domain Calculation of Active Damping in Multi-inverter Grid-connected Systems

  • Wu, Jian;Chen, Tao;Han, Wanqin;Zhao, Jiaqi;Li, Binbin;Xu, Dianguo
    • Journal of Power Electronics
    • /
    • v.18 no.1
    • /
    • pp.185-194
    • /
    • 2018
  • Interaction among multiple grid-connected inverters has a negative impact on the stable operations and power quality of a power grid. The interrelated influences of inverter inductor-capacitor-inductor filters constitute a high-order power network, and consequently, excite complex resonances at various frequencies. This study first establishes a micro-grid admittance matrix, in which inverters use deadbeat control. Multiple resonances can then be evaluated via modal analysis. For the active damping method applied to deadbeat control, the sampling frequency and the stable domain of the virtual damping ratio are also presented by analyzing system stability in the discrete domain. Simulation and experimental results confirm the efficiency of modal analysis and stable domain calculation in multi-inverter grid-connected systems.

Design of High Frequency Resonant High-tension Transformer in Inverter Type X-Ray Generator (인버터식 X선발생장치용 고주파 공진형 고압변압기 등의 설계)

  • Lee, Seong-Kil;Choi, Sung-Kwan
    • Journal of radiological science and technology
    • /
    • v.24 no.2
    • /
    • pp.5-11
    • /
    • 2001
  • Most of X-ray generator had used rectifier type transformer with high tension generator which is supplied in a clinical diagnosis. Because the ripple rate of tube voltage is high, X-ray generating efficiency is very low. In these days, high tension generator for inverter type X-ray generator is being supplied from a broad which uses semi-conductor switching element for the electric power that have a high speed switching ability to solve these problem. But, semi-conductor element with large capacity is used with X-ray tube's large consumption power and diffusion is difficult in the small size hospital because production cost is going up by doing digital control through DSP. Therefore, this paper designed and manufactured CR type voltage divider for feedback control of tube voltage with high frequency resonance type inverter and for high tension transformer with high frequency. It was to make economical diffusion type X-ray generator which has wide output voltage and load extent. It was preyed that the X-ray generator had the stability of X-ray tube's output characteristics.

  • PDF

Analysis and Control of NPC-3L Inverter Fed Dual Three-Phase PMSM Drives Considering their Asymmetric Factors

  • Chen, Jian;Wang, Zheng;Wang, Yibo;Cheng, Ming
    • Journal of Power Electronics
    • /
    • v.17 no.6
    • /
    • pp.1500-1511
    • /
    • 2017
  • The purpose of this paper is to study a high-performance control scheme for neutral-point-clamping three-level (NPC-3L) inverter fed dual three-phase permanent magnet synchronous motor (PMSM) drives by considering some asymmetric factors such as the non-identical parameters in phase windings. To implement this, the system model is analyzed for dual three-phase PMSM drives with asymmetric factors based on the vector space decomposition (VSD) principle. Based on the equivalent circuits, PI controllers with feedforward compensation are used in the d-q subspace for regulating torque, where the cut-off frequency of the PI controllers are set at the twice the fundamental frequency for compensating both the additional DC component and the second order component caused by asymmetry. Meanwhile, proportional resonant (PR) controllers are proposed in the x-y subspace for suppressing the possible unbalanced currents in the phase windings. A dual three-phase space vector modulation (DT-SVM) is designed for the drive, and the balancing factor is designed based on the numerical fitting surface for balancing the DC link capacitor voltages. Experimental results are given to demonstrate the validity of the theoretical analysis and the proposed control scheme.

Seamless Mode Transfer of Utility Interactive Inverters Based on Indirect Current Control

  • Lim, Kyungbae;Song, Injong;Choi, Jaeho;Yoo, Hyeong-Jun;Kim, Hak-Man
    • Journal of Power Electronics
    • /
    • v.19 no.1
    • /
    • pp.254-264
    • /
    • 2019
  • This paper proposes an indirect current control technique based on a proportional resonant (PR) approach for the seamless mode transfer of utility interactive inverters. Direct-current and voltage hybrid control methods have been used for inverter control under grid-connected and islanded modes. A large bandwidth can be selected due to the structure of single-loop control. However, this results in poor dynamic transients due to sudden changes of the controller during mode changes. Therefore, inverter control based on indirect current is proposed to improve the dynamic transients by consistently controlling the output voltage under all of the operation modes. A PR-based indirect current control topology is used in this study to maintain the load voltage quality under all of the modes. The design processes of the PR-based triple loop are analyzed in detail while considering the system stability and dynamic transients. The mode transfer techniques are described in detail for both sudden unintentional islanding and islanded mode voltage quality improvements. In addition, they are described using the proposed indirect control structure. The proposed method is verified by the PSiM simulations and laboratory-scale VDER-HILS experiments.

The Driving Characteristics of Ultrasonic Motor (초음파 모터의 구동 특성)

  • Choi, Jung-Seok;Baek, Soo-Hyun;Kim, Yong;Yoon, Shin-Yong;Choi, Chul-Yong;Kim, Il-Nam
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.783-785
    • /
    • 2002
  • In this paper, the driving characteristic for a ring type ultrasonic motor is described. For driving of ultrasonic motor, a two-phase parallel-resonant inverter was made. The driving circuit simulation results are compared with measured frequencis and amplitudes.

  • PDF

A Study on the Power Supply for Endura Electrodeless Lamp (엔두라 무전극 램프용 전원장치 연구)

  • 한수빈;박석인;정봉만;김규덕;이선근
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.15-18
    • /
    • 2002
  • Power supply technique for electrodeless lamps, especially Endura of Osram, is presented in this paper. The power supply uses a conventional power factor correction technique due to its proved performance. But in the inverter stage, resonant converter with parallel loading scheme is used to mitigate the variation of matching circuit characteristics by time varying load. Less performance but sufficient to predict future success compared to Osram's one is verified as a result of experiment of the prototype.

  • PDF

A Study on the Power Supply for Electrodeless Lamp (무전극 형광등용 전원)

  • Han, Soo-Bin;Jang, Woo-Jin
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.13-16
    • /
    • 2004
  • Power supply technique for electrodeless lamps is presented in this paper. The power supply uses a conventional power factor correction technique due to its proved performance. But in the inverter stage, resonant converter with parallel loading scheme is used to mitigate the variation of matching circuit characteristics by time varying load. Experiment and performance comparison for both Endura md QL are performed and further study to commercialization are discussed.

  • PDF