• 제목/요약/키워드: Resonant inverter

검색결과 601건 처리시간 0.024초

Control Strategies for Multilevel APFs Based on the Windowed-FFT and Resonant Controllers

  • Han, Yang
    • Journal of Power Electronics
    • /
    • 제12권3호
    • /
    • pp.509-517
    • /
    • 2012
  • This paper presents control strategies for cascaded H-bridge multilevel active power filters (APFs). A current loop controller is implemented using a proportional-resonant (PR) regulator, which achieves zero steady-state error at target frequencies. The power balancing mechanism for the dc-link capacitor voltages is analyzed and a voltage balancing controller is presented. To mitigate the picket-fence effect of the conventional FFT algorithm under asynchronous sampling conditions, the Hanning Windowed-FFT algorithm is proposed for reference current generation (RCG). This calculates the frequency, amplitude and phase of individual harmonic components accurately and as a result, selective harmonic compensation (SHC) is achieved. Simulation and experimental results are presented, which verify the validity and effectiveness of the devised control algorithms.

고주파 공진형 PWM 인버어터 제어 DC/DC 콘버어터 (A Novel High-Frequency Resonant Type PWM DC/DC Converter)

  • 이종무;위상봉;구현희;김요희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1987년도 정기총회 및 창립40주년기념 학술대회 학회본부
    • /
    • pp.343-346
    • /
    • 1987
  • This paper proposes a novel high-frequency resonant DC/DC converter having PWM(Pulse Width Modulation) inverter control function. The operating characteristics of this converter circuit are discussed from a thereotical point of view and compared with experimental results. The results of operating characteristic analysis are given leading to complete designing data.

  • PDF

부분공진기법을 이용한 태양광발전 제어시스템 (The Photovoltaic generation control system using partial resonant method)

  • 고강훈;이현우;김영철;최광주
    • 조명전기설비학회논문지
    • /
    • 제14권4호
    • /
    • pp.16-22
    • /
    • 2000
  • 본 논문은 트렌스포머를 제거하고 부분공짚 스위칭 기법올 적용한 승.강압초퍼와 고효율의 PWM 인버터를 결합한 트렌스포머리스형 계통연계 시스템을 구성하게 되므로 소형경량화가 가능하며, 비용저지감과 신뢰성 향상을 도모할 수 있다. 이러한 시스템의 장점으로서는 태양잔지의 발전전압의 크기에 관계없이 임의의 전력올 부하와 계통에 송전할 수 있으며, 계통과 동상의 신호로 제어함으로서 상 고역률올 얻을 수 있다.

  • PDF

고성능 무선충전 시스템 개발 (Developed high performance wireless charging system)

  • 조철희;진아비;장해용;김동희
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2018년도 전력전자학술대회
    • /
    • pp.368-369
    • /
    • 2018
  • In this paper, a wireless charging system for drones is developed. The system is consists of PFC(Power Factor Correction), Full-Bridge inverter, S-S(Series-Series) resonant circuit and Full-Bridge rectifier. The parameters of the S-S resonant circuit is designed and calculated. According to these parameters and the switching devices, the system model without PFC is setted up with thermal module devices in PSIM. When output voltage is setted to 50[V] and input voltage is changed from 100[V] to 380[V], The efficiency of the system model is measured by simulation.

  • PDF

다중일차권선 비접촉변압기를 이용한 비접촉 전원시스템의 공진주파수 추적에 관한 연구 (Study on resonant frequency tracking for contactless power system using multiple primary winding contactless transformer)

  • 김윤호;노성찬
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제55권3호
    • /
    • pp.182-188
    • /
    • 2006
  • Contactless power system is base on power transmission by magnetic force. The transformer loss is large because it separated with the gap. Also the system has unstable factor, since the parameters in the secondary can vary with the system movement. This paper proposes light train power transmission system using contactless transformer with multiple primary winding. To increase the system efficiency and to obtain the stable power transmission to the dynamic load, a resonant inverter is adopted. The proposed system was verified by the simulation using Spice and Maxwell. The designed contactless power transmission system is implemented for 5[kW] class and experimental results are discussed.

Analysis of Phase Error Effects Due to Grid Frequency Variation of SRF-PLL Based on APF

  • Seong, Ui-Seok;Hwang, Seon-Hwan
    • Journal of Power Electronics
    • /
    • 제16권1호
    • /
    • pp.18-26
    • /
    • 2016
  • This paper proposes a compensation algorithm for reducing a specific ripple component on synchronous reference frame phase locked loop (SRF-PLL) in grid-tied single-phase inverters. In general, SRF-PLL, which is based on all-pass filter to generate virtual voltage, is widely used to estimate the grid phase angle in a single-phase system. In reality, the estimated grid phase angle might be distorted because the phase difference between actual and virtual voltages is not 90 degrees. That is, the phase error is caused by the difference between cut-off frequency of all-pass filter and grid frequency under grid frequency variation. Therefore, the effects on phase angle and output current attributed to the phase error are mathematically analyzed in this paper. In addition, the proportional resonant (PR) controller is adapted to reduce the effects of phase error. The validity of the proposed algorithm is verified through several simulations and experiments.

LCCL 공진네트워크를 이용한 RPG용 공진형 인버터 시스템 설계 및 제어 (Design and Control of Resonant Inverter Systems Using LCCL Resonant Network for RPG)

  • 구근완;성원용;유승희;임창섭;이병국
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2017년도 전력전자학술대회
    • /
    • pp.60-61
    • /
    • 2017
  • 본 논문에서는 플라스마 부하의 특성을 고려하여 LCCL 공진 네트워크가 적용된 RPG (remote plasma generator)용 공진형 인버터를 설계 하고 제어한다. 공진네트워크 설계와 인버터 제어 시, 플라스마 부하가 가지는 특징인 Drop-out 현상을 방지하면서 정격범위 내에서 출력 전류를 얻을 수 있도록 하기 위해 위상천이 기법을 적용할 수 있도록 설계하고 시뮬레이션을 통해 설계된 공진네트워크의 타당성을 검증한다.

  • PDF

PWM 제어 방법을 이용한 LCL 직렬 공진 콘버터에 관한 연구 (LCL Type Series Resonant Converter with PWM Control Method)

  • 현동석;이요한;추병호;송인호;민경진
    • 전력전자학회논문지
    • /
    • 제2권2호
    • /
    • pp.19-28
    • /
    • 1997
  • 본 논문에서는 위상제어를 이용한 LCL형 직렬공진 콘버터의 간단한 AC 복소해석이 수행되었다. 이 해석에 근거하여 탱크 회로의 volt-ampere 정격을 증가시키지 않는 콘버터의 최적 설계를 가능하게 하는 일련의 특성곡선들을 제시하였다. 특히 정격부하나 경부하에서도 인버터 출력전류의 피크치를 최소화할 수 있게 되었다. 제시한 설계 예에서, 과부하에서 경부하에 이르는 넓은 부하범위에서 영전압 턴온 동작을 할 수 있음을 보여준다. 시뮬레이션과 실험결과를 통해 제안된 회로의 유용성을 증명한다.

  • PDF

수 초 지속 40 kV, 280 kW 고전압 펄스전원장치 개발 (Development of Few-second 40 kV, 280 kW High Voltage Pulse Power Supply)

  • 김성철;남상훈;허훈;공형섭;문철;김정호;오승섭;양종원;소준호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.990-991
    • /
    • 2015
  • To drive a magnetron injection gun, thsi paper decribes a design, fabrication and analysis results of proposed compact capacitor charging power supply (CCPS) formed resonant full-bridge inverter for electron gun power supply (EGPS). EGPS needs the -40 kV output voltage and 280 kW output power for few seconds continuously and have to be designed for the rise and fall time to be less than 1 ms with the ripple stability of output voltage of lower than 1%. In order to meet the requirements, we used eight resonant full-bridge modules operated in parallel. Each resonant full-bridge module can supply the current of 0.9 A and the voltage of 40 kV, and is operated by N-phase shift switching pattern. In this paper, we present the design, simulation and test results of interleaved CCPS.

  • PDF

A Simple Resonant DC Link Snubber-Assisted Bi-directional Three-phase PWM Converter for Battery Energy Storage Systems

  • Hiraki, Eiji;Nakaoka, Mutsuo
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제2B권3호
    • /
    • pp.133-139
    • /
    • 2002
  • In this paper, a prototype of an active auxiliary quasi-resonant DC link (QRDCL) snubber assisted voltage source bidirectional power converter (AC to DC and DC to AC) operating at zero voltage soft-switching (BVS) PWM nlode is presented for a Battery Energy Storage System (BESS). The operating principle of this QRDCL circuit and multifunctional control-based converter system, including PWM inverter mode in which energy flows from the battery bank to the three-phase utility-grid in addition to an active PWM converter mode in which energy flows from the utility-grid to the battery banks are described respectively by the control implementation on the basis of d-q coordinate plane transformation. The multifunctional operation characteristics of this three-phase ZVS PWM bi-directional converter with QRDCL is demonstrated fer a BESS under the power conditioning and processing schemes of energy supply mode and energy storage mode, and compared with a conventional three-phase hard switching PWM bi-directional converter for a BESS. The effectiveness of the three-phase ZVS PWM hi-directional converter with QRDCL is proven via the simulation analysis.