• Title/Summary/Keyword: Resonant inverter

Search Result 601, Processing Time 0.022 seconds

Modified Dual-Buck Inverter Based on Resonant Link

  • Chen, Rong;Zhang, Jia-Sheng;Liu, Wei
    • Journal of Power Electronics
    • /
    • v.15 no.6
    • /
    • pp.1421-1428
    • /
    • 2015
  • The efficiency and reliability of the dual-buck inverter (DBI) were greatly improved by eliminating the shoot-through problem and optimally designing the freewheeling diode. The traditional DBI suffers from large harmonic components with low output voltage and large capacity output filter inductor. To overcome the aforementioned disadvantages, a modified DBI (MBDI) was proposed by adopting a quasi-resonant link and pulse density modulation (PDM). This paper first introduces the working principle of the MBDI and PDM, and then the selection principle of system parameters is presented. Finally, a mathematical model of the MBDIis built, and an experiment prototype is set up. Simulation and experimental results verify the correctness of the theoretical analysis and the feasibility of the scheme.

A Study on the Output Characteristics of High-Frequency Resonant Inverter Type for X-ray Generators in Short Exposure Time. (고주파 공진형 인버터 X선 장치의 단시간 출력특성에 관한 연구)

  • 이성길;임홍우;이상일;조금배;백형래
    • Proceedings of the KIPE Conference
    • /
    • 1998.07a
    • /
    • pp.129-133
    • /
    • 1998
  • This paper deals with a characteristic of output for high frequency resonant inverter type x-ray generator in short exposure time. In the same tube-voltage, the waveform is stable in long exposure time (200msec) but more decreasing exposure time (50msec), the waveform is distorted. The ripple factor of tube-voltage waveform distorted more and more increase tube-voltage and in this case output is also unstable. High-frequency resonant inverter type X-ray generator using PSU source which introduced in resent is stable tube-voltage waveform and low ripple factor.

  • PDF

Soft Switching Inverter with An Auxiliary Active Quasi-Resonant DC Link Snubber for AC Servo Motor Drive

  • Mun, Sang-Pil;Kim, Chil-Ryong;Lee, Jong-Kurl;Park, Man-Kyu;Kwon, Soon-Kurl
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.3
    • /
    • pp.79-87
    • /
    • 2008
  • This paper presents a simple circuit topology of the auxiliary active quasi-resonant DC link snubber-assisted three phase voltage source soft-switching inverter for small scale PM motor drive applications. The pulse processing drive circuit interface and its soft-switching operation are discussed from an experimental point of view. Moreover, its conductive noise is measured and evaluated for electrical AC servo motor drive as compared with that of the conventional hard switching inverter.

Active Front End Inverter with Quasi - resonance

  • Siebel, Henrik;Pacas, J.M.
    • Journal of Power Electronics
    • /
    • v.3 no.1
    • /
    • pp.17-23
    • /
    • 2003
  • A new three-phase soft-switching active front-end inverter is presented. The topology consists of a quasi-resonant PWM boost converter with an additional resonant branch, which provides low loss at high frequency operation. This leads to a high conversion efficiency and a remarkable reduction in the siBe of the input inductor. To synchronise the PWM pattern with the resonance cycle, a modified space vector modulation with asymmetrical PWM pattern is used. A high power factor can be achieved for both power flow directions. Due to a new control strategy the converter features a low content of harmonics in the line currents even for distorted line voltages.

A Study on the Optimization of Induction Heating System for Using Half-Bridge High-Frequency Series Resonant Inverter (Half-Bridge 고주파 직렬 공진형 인버터를 이용한 유도가열 시스템의 최적화에 관한 연구)

  • Kim, Chul-Ho;Shin, Dae-Cheul;Kwon, Hyuk-Min;Kim, Kee-Hwan;Kim, Yong-Ju
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.78-80
    • /
    • 2005
  • This paper is described the stability and optimization according to each load of induction heating system for using half-bridge high-frequency series resonant inverter. Each metallic package is inserted into the ceramic type vessel with external working coil. This working coil is connected to the resonant inverter. It evaluates performance and stability of this system according to metallic package.

  • PDF

The design of CCFL Driving Circuit by Resonant Invertor and Dimming IC (조도조절이 가능한 공진형 인버터 적용 CCFL 구동회로의 설계)

  • Kim, Cherl-Jin;Ji, Jae-Geun;Kim, Sung-Lae;Yoon, Shin-Yong
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.1181-1183
    • /
    • 2003
  • Cold cathode fluorescent lamp(CCFL) are widely used to illuminate the liquid crystal display(LCD). Usually, CCFL dimming methods are used to lamp current regulation or average current adjust feeding the CCFL inverter. Switching frequency of inverter is higher than resonant frequency at stabile states. In this study, design of CCFL driving circuit by half-bridge type series and parallel resonant inverter that variable frequency modulation method to control the output power. This method has advantages such as low EMI and reduced harmonics. And it is easy to dimming control use microprocessor. The validity of this study is confirmed from the simulation and experimental results.

  • PDF

Control Strategy of Resonant DC Link Inverter for UPS (UPS용 병렬공진형 직류링크인버터를 위한 제어방식에 관한 연구)

  • Beak, J.W.;Yoo, D.W.;Min, B.G.;Ryu, S.P.
    • Proceedings of the KIEE Conference
    • /
    • 1994.11a
    • /
    • pp.159-161
    • /
    • 1994
  • A new control technique which generates high-quality sinusoidal output voltage from a single-phase resonant do link inverter suitable for the UPS systems is presented. The inverter output voltage control system has the PID controller with a minor loop of the filter inductor current and tile feedforward controller. The proposed control scheme also solves resonant voltage overshoot without any additional switch or passive component, resulting in pulses with uniform amplitude and high efficiency. Experimental results in the case of linear and nonlinear loads are presented to confirm the usefulness of the Proposed control algorithms.

  • PDF

Active front end inverter with quasi - resonance

  • Siebel H.;Pacas J. M.
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.146-150
    • /
    • 2001
  • A new three-phase soft-switching active front-end inverter is presented. The topology consists of a quasi-resonant PWM boost converter with an additional resonant branch, which provides low loss at high frequency operation. This leads to a high conversion efficiency and a remarkable reduction in the size of the input inductor. To synchronise the PWM pattern with the resonance cycle, a modified space vector modulation with asymmetrical PWM pattern is used. A high power factor can be achieved for both power flow directions. Due to a new control strategy the converter features a low content of harmonics in the line currents even for distorted line voltages.

  • PDF

Active-clamp Class-E High Frequency Resonant Inverter with Single-st (단일 전력단으로 구성된 Active-clamp E급 고주파 공진 인버터)

  • Kang, Jin-Wook;Won, Jae-Sun;Kim, Dong-Hee;Ro, Chae-Gyun;Sim, Kwang-Yeal;Le, Bong-Sub
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.1193-1195
    • /
    • 2002
  • This paper presents Active-clamp Class-E high frequency resonant inverter with single-stage. The proposed circuit is integrated Active-c class-E circuit to boost converter with the funct power factor correction. Boost converter is opera positive and negative half cycle respectively at frequency(60Hz), operating in Discontinuous Con Mode(DCM) of boost converter performs high p factor. By adding active-clamp circuit in Cl inverter, main switch of inverter part is operat only ZVS(Zero Voltage Switch), but also reduce switching voltage stress of main switch. Simulation result using Psim4.1 show that the p prove the validity of theoretical analysis. This proposed inverter will be able to be pract used as a power supply in various fields are ind heating applications, DC-DC converter etc.

  • PDF

A Study On Sing1e-Stage Active-Clamp Type High Frequency Resonant Inverter (단일 전력단 능동 클램프형 고주파 공전 인버터에 관한 연구)

  • 강진욱;원재선;김동희;조규판;김경식
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.287-291
    • /
    • 2002
  • This paper presents active-clamp class-E high frequency resonant inverter with single-stage. The proposed circuit is integrated active-clamp class-E circuit to boost converter with the function of power factor correction. Boost converter is operated in positive and negative half cycle respectively at line frequency(60Hz), Such a operating in discontinuous conduction mode(DCM) of boost converter performs high power factor. By adding active-clamp circuit in class-E inverter, main switch of inverter part is operated not only ZVS(Zero Voltage Switch) but also reduced the switching voltage stress of main switch. This paper shows that simulation result using Psim 4.1 prove the validity of theoretical analysis. This proposed inverter will be able to be practically used as a power supply in various fields as induction heating applications, DC-DC converter etc.

  • PDF