• Title/Summary/Keyword: Resonant current

Search Result 960, Processing Time 0.024 seconds

Analysis of Bridge Inverter Circuit (브리지 인버어터 회로의 해석)

  • 박준열
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.15 no.3
    • /
    • pp.30-34
    • /
    • 1978
  • A bridge inverter circuit with a paralled resonant circuit load is analyzed. The approach to the circuit analysis leads to reasonable reality. The limit of trigger frequency, the range of SCR turn-off time, the peak capacitor voltage and the relation between the load current and trigger rate are derived for the suitable design criteria. Numerical method is used for calculation of transcendental equation.

  • PDF

A Study on Modeling of High-Frequency Leakage Currents in PWM Inverter Feeding an Induction Motor (유도전동기의 PWM제어와 누설 축전류 발생 모델링에 관한 연구)

  • 이재호;임경내;전진휘;박성준;김철우
    • Proceedings of the KIPE Conference
    • /
    • 1998.07a
    • /
    • pp.221-224
    • /
    • 1998
  • A PWM inverter with an induction motor often has a problem with a high-frequency leakage current that flows through the distributed electrostatic capacitance from the motor windings to ground. This paper presents an equivalent circuit for high-frequency leakage currents in PWM inverter feeding an induction motor, which forms an LCR series resonant circuit.

  • PDF

Improved ZCS-PWM Boost Converter (개선된 영전류 PWM 부스트 컨버터)

  • Ahn Jun-Youn;Choi Hang-Seok;Yoo K. J.;Cho B. H.
    • Proceedings of the KIPE Conference
    • /
    • 2002.07a
    • /
    • pp.382-385
    • /
    • 2002
  • In this paper, an improved ZCS-PWM boost converter is proposed to minimize conduction loss by flowing resonant current only through the auxiliary circuit. The operation principle of the proposed converter is explained and design procedure is established. Experimental results are presented to verify the theoretical analysis.

  • PDF

Energy Recovery Circuit for the Plasma Display Panel Sustainer

  • Cho, B.H.;Kim, W.S.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07a
    • /
    • pp.625-630
    • /
    • 2005
  • In this paper, several energy recovery circuits (ERC) for the plasma display panel (PDP) are reviewed and classified in a manner of operation characteristics. A typical ERC using the Regenerative Transformer (RT) is introduced and compared with conventional ones. RT-ERC can achieve zero-voltage-switching (ZVS) for main full-bridge switches and zero-current-switching (ZCS) for the resonant switches and diodes. The charging/discharging energy of panel capacitance is efficiently recovered with the RT and without a sub-circuit. The presented circuit is verified with simulation and experimental results.

  • PDF

Aperture-Coupled Microstrip Antenna with Four Slits and T-Slits for Compact Circular Polarization Operation (슬릿이 부설된 소형 원편파 개구결합 마이크로 스트립 안테나)

  • 김영두;김호용;이홍민
    • Proceedings of the IEEK Conference
    • /
    • 2003.11c
    • /
    • pp.327-330
    • /
    • 2003
  • A novel compact circular polarization operation of the microstrip antenna with four-slits and T-slits is proposed. The mechanism for compact size antenna is investigated with the behavior of the currents on the radiating patch. The equivalent surface current path due to the slits is lengthened, reducing the resonant frequency at a fixed patch size. The proposed compact CP design can have an antenna size reduction of about 33 ∼ 45% as compared to the conventional microstrip antenna. Details of the experimental and measured results are presented and analysed.

  • PDF

A New Current Fed Resonant Converter Suitable for Step Down Application (강압 응용에 적합한 새로운 전류원 공진형 컨버터)

  • Moon, Dongok;Lee, Sanghyuk;Choi, Sewan
    • Proceedings of the KIPE Conference
    • /
    • 2013.07a
    • /
    • pp.295-296
    • /
    • 2013
  • 본 논문에서는 새로운 전류원 공진형 컨버터를 제안한다. 제안한 컨버터는 입력전류 리플이 작으며 모든 스위치와 다이오드의 ZCS 턴온/턴오프를 성취하며 턴온/턴오프 전류의 di/dt가 0이다. 또한, 인터리빙 시 출력전류 리플을 이론적으로 완전히 제거할 수 있다. 제안하는 컨버터의 동작원리를 제시하고 실험을 통하여 타당성을 검증하였다.

  • PDF

Method of Moments Analysis for Theoretical Site Attenuation Curves (시험장감쇠량 이론곡선의 모멘트 법 해석)

  • Ki Chai Kim
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.29A no.7
    • /
    • pp.39-47
    • /
    • 1992
  • This paper showed that theoretical site attenuation curves were obtained simply by the method of moments analysis for current integral equations on antennas. Since the expansion coefficients of driving and receiving points were calculated from the method of moments procedure, site attenuations were evaluated simply using these basic antenna parameters. Theoretical site attenuations were calculated with half-wave resonant dipoles connected directly to a 50 ohm receiving system and connected to a 72/50 ohm matching network, respectively. Results were compared with other theoretical studies reported so far. Also included were experimental results for site attenuations to prove the validity of theoretical analysis.

  • PDF

ELECTRONIC BALLAST FOR MHD LAMPS OF AUTOMOTIVE HEADLIGHT (자동차 헤드라이트용 MHD 램프등의 전자의 안정기)

  • Park, Chong-Yeun;Ju, Byung-Hun
    • Proceedings of the KIEE Conference
    • /
    • 1999.07g
    • /
    • pp.3129-3131
    • /
    • 1999
  • The electronic ballast for MHD lamp was studied for automotive headlight application. Its basic principle is the Current Sourcing Push-Pull Resonant Inverter with DC I2Volt input Voltage. By changing the switching frequency according to the lamp state, the automotive requirement of very fast warm-up and the zero voltage switching condition were shown by the simulation of the ballast circuit.

  • PDF

A Study on Input Current Waveform Analysis for Step Up-Down AC-DC Converter of High Power Factor added Electric Isolation (고역률 스텝 업-다운 절연형 AC-DC 컨버터의 입력전류 파형분석에 관한 연구)

  • Kwak, Dong-Kurl;Kim, Choon-Sam;Lee, Bong-Seob;Kim, Sang-Hoon
    • Proceedings of the KIPE Conference
    • /
    • 2008.06a
    • /
    • pp.34-36
    • /
    • 2008
  • This paper is given a full detail of mathematical analyses of input current for novel active type power factor correction(PFC) AC-DC converter of step up-down added electric isolation. These are compared with harmonics components of input current for a conventional PFC converter of electric isolation type. The proposed PFC converter is constructed in using a new loss-less snubber circuit to achieve a soft switching of control device. Also the proposed converter for discontinuous conduction mode(DCM) eliminates the complicated circuit control requirement and reduces the size of components. The input current waveform in the proposed converter is got to be a sinusoidal form of discontinuous pulse in proportion to magnitude of ac input voltage under the constant duty cycle switching. Therefore, input power factor is nearly unity and the control method is simple. Particularly, the stored energy of loss-less snubber capacitor is recovered with input side and increases input current from resonant operation. The result is that input power factor of the proposed converter is higher than that of a conventional PFC converter. Some simulative results on computer and experimental results are included to confirm the validity of the analytical results.

  • PDF

A 2nd Order Harmonic Compensation Method for Wind Power System Using a PR Controller

  • Jeong, Hae-Gwang;Lee, Jong-Hyun;Lee, Kyo-Beum
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.3
    • /
    • pp.507-515
    • /
    • 2013
  • This paper proposes a compensation method for the $2^{nd}$-order harmonic of single-phase grid-connected wind power generation systems. Theoretically, a single-phase grid-connected inverter system has no choice but to cause the $2^{nd}$-order harmonic to DC-link voltage. The reference active current is affected by the DC-link voltage. The output current from the reference active current is distorted by the $1^{st}$ and $3^{rd}$-order harmonic. The proposed method can compensate, conveniently, the reference active current with the $2^{nd}$-order harmonic. To reduce the $2^{nd}$-order ripple in the reference active current, proposed method takes a PR controller as a feed-forward compensator. PR controllers can implement selective harmonic compensation without excessive computational requirements; the use of these controllers simplifies the method. Both the simulation and experimental results agree well with the theoretical analysis.