• 제목/요약/키워드: Resonance method

검색결과 2,472건 처리시간 0.027초

Wireless Power Transfer via Magnetic Resonance Coupling (MRC) with Reduced Standby Power Consumption

  • Lee, Byoung-Hee
    • Journal of Power Electronics
    • /
    • 제19권3호
    • /
    • pp.637-644
    • /
    • 2019
  • Wireless power transfer (WPT) technology with various transfer mechanisms such as inductive coupling, magnetic resonance and capacitive coupling is being widely researched. Until now, power transfer efficiency (PTE) and power transfer capability (PTC) have been the primary concerns for designing and developing WPT systems. Therefore, a lot of studies have been documented to improve PTE and PTC. However, power consumption in the standby mode, also defined as the no-load mode, has been rarely studied. Recently, since the number of WPT products has been gradually increasing, it is necessary to develop techniques for reducing the standby power consumption of WPT systems. This paper investigates the standby power consumption of commercial WPT products. Moreover, a standby power reduction technique for WPT systems via magnetic resonance coupling (MRC) with a parallel resonance type resonator is proposed. To achieve a further standby power reduction, the voltage control of an AC/DC travel adapter is also adopted. The operational principles and characteristics are described and verified with simulation and experimental results. The proposed method greatly reduces the standby power consumption of a WPT system via MRC from 2.03 W to 0.19 W.

Resonance Integral of Neptunium(237Np) from Energy Dependent Differential Neutron Capture Cross-Section by Using the Linac TOF Method and C6D6 Scintillation Spectrometer

  • Lee, Sam-Yol
    • 한국방사선학회논문지
    • /
    • 제5권4호
    • /
    • pp.217-221
    • /
    • 2011
  • $^{237}Np$ is very important material in the fission products of nuclear reactors. Resonance integral(RI) tests of this material is necessary to check between the experiments and the evaluated data. Such feedback to the evaluated data is very important to correct data and improve of codes. The RI for the $^{237}Np(n,{\gamma})^{238}Np$ reaction were measured by using the 46-MeV electron linear accelerator (linac) at the Research Reactor Institute, Kyoto University (KURRI). The measurement was performed in the energy region from 0.005 eV and 10 keV. RI obtained as 804.7 barns, compared with those of the evaluated data in JENDL-4.0 and Mughabghab.

공진주파수 스펙트럼법을 이용한 압전박막의 특성 평가 (Evaluating Piezoelectric Thin Film Characteristics Using Resonance Spectrum Method)

  • 최준영;장동훈;강성준;윤영섭
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2004년도 하계종합학술대회 논문집(2)
    • /
    • pp.477-480
    • /
    • 2004
  • We studied the characteristics of impedance and electromechanical coupling coefficient in ZnO and AIN thin films by using resonance frequency spectrum method. The response peak of impedance decreased with the decrease of thickness of piezoelectrics, the number of mode of response peak increased with the increase of substrate thickness. An error of $k_{t}^{2}$ estimated from input $k_{t}^{2}$ increased as the thickness of piezoelectrics decreased and the thickness of substrate increased. Also, the error was increased in case of a large acoustic impedance of substrate. It was found that the composite resonator operating in optimized condition could be designed through the resonance frequency spectrum analysis of composited resonator consisted of piezoelectric thin film and substrate.

  • PDF

전파 흡수체에 의한 구형 공동 공진기의 방사노이즈 억제 방법에 관한 연구 (A Study on the Method to Suppress Radiation-Noise with Electromagnetic Wave Absorber in the Rectangular Cavity Resonator)

  • 김경용;김왕섭
    • 전자공학회논문지A
    • /
    • 제28A권12호
    • /
    • pp.19-23
    • /
    • 1991
  • A method for suppressing unwanted resonance modes by attaching an electromagnetic wave absorber onto a metal case was studied to prevent performance deterioration of electronic devices. The electromagnetic wave absorber fabricated for this study had an attenuation characteristics above 20dB in the frequency band from 450MHz, 1150MHz. A rectangular cavity resonator whose resonance frequencies of TE$_{101}$, TE$_{102}$ modes were 900MHz, 1250MHz, respectively, was made to measure attenuation for the electromagnetic wave absorber-metal assembly. The result showed that the resonance mode for high attenuation was sensitive to the location of electromagnetic wave absorber, and the attenuation characteristics above 20dB could be obtained when electromagnetic wave absorber was properly positioned.

  • PDF

SK 지수를 이용한 표면 플라즈몬 공명 바이오 센서의 측정방법의 분류 (Classification of Measurement Methods of Surface Plasmon Resonance Biosensors by SK Index)

  • 이승기
    • 센서학회지
    • /
    • 제13권5호
    • /
    • pp.342-349
    • /
    • 2004
  • SK (SPR Kinds) index, which can categorize the complicated measurement methods of surface plasmon resonance by simple method, has been proposed and verified. SK index is composed of three digits, where each digit presents the type of immobilized ligand, the type of illumination and the kinds of varying parameter, sequentially. The measurement method of (33#) series among SK indices shows the possibility of the multi-sensing capability, by which the response of 2-dimensional array of immobilized ligands can be detected simultaneously. The proposed possibility of multi-sensing capability has been verified by the modeling that is based on Fresnel reflection model.

Piezoelectric and Acoustic Properties of Ultrasonic Sensor Using 2-2 Piezocomposites

  • Lee, Sang-Wook;Nam, Hyo-Duk;Ryu, Jeong-Tak;Kim, Yeon-Bo
    • 한국정보기술응용학회:학술대회논문집
    • /
    • 한국정보기술응용학회 2005년도 6th 2005 International Conference on Computers, Communications and System
    • /
    • pp.215-218
    • /
    • 2005
  • We have investigated on the development of 2-2 piezocomposites that have better piezoelectric activity and lower acoustic impedance than those of conventional piezoceramics. In this study, we have investigated the piezoelectric and acoustic properties of 2-2 piezocomposites sensor which were fabricated using dice-and-fill technique for the different volume fraction of PZT. The resonance characteristics measured by an impedance analyzer were similar to the analysis of finite element method. The resonance characteristics and the electromechanical coupling factor were the best when the volume fraction PZT was 0.6. It also showed the highest result from the standpoint of sensitivity, bandwidth and ring-down property and so on at the same condition. The specific characteristics shows that the 2-2 piezocomposites turned out to be superior to the ultrasonic sensor composed by single phase PZT.

  • PDF

고감도 단금속 및 쌍금속 표면 플라즈몬 공명 센서 설계를 위한 수치해석 연구 (Numerical Investigation on Surface Plasmon Resonance Sensor Design with High Sensitivity Using Single and Bimetallic Film Structures)

  • 권혁록;이성혁
    • 전기학회논문지
    • /
    • 제58권4호
    • /
    • pp.795-800
    • /
    • 2009
  • Surface plasmon resonance (SPR) has been widely used for biological and chemical sensing applications. The present study investigates numerically the optical characteristics for the single Au film and bimetallic Ag/Au film SPR configurations by using the multiple beam interference matrix (MBIM) method. We use the prism coupling method, especially Kretschmann configuration for excitation of surface plasmon wave (SPW). The estimated results of reflectance, phase shift and magnetic field intensity enhancement factor are provided for finding out the optimum configuration with high sensitivity for SPR measurement. As a result, the optimum thicknesses are found to be 52 nm for a single Au film and 5 nm to 36 nm for bimetallic Ag-Au film. From the comparison of full width half maximum (FWHM) values for reflectance, phase shift, and enhancement of magnetic field intensity, it is concluded that the highest sensitivity can be obtained when using the phase shift for SPR sensor.

두 개의 송신코일을 갖는 위상 천이 자기 공진 무선 전력 전송 시스템 (Phase Shifted Magnetic Resonance Wireless Power Transfer System with Two Transmit Coils)

  • 정재엽;이강현
    • 전력전자학회논문지
    • /
    • 제23권4호
    • /
    • pp.290-293
    • /
    • 2018
  • This paper proposes a new magnetic resonant wireless power transfer system. Two transmitters are arranged to secure a range wider than the existing one-to-one resonance, thereby enhancing the practicality of the system. Two identical transmission units are arranged to strengthen the magnetic field and to subsequently increase the magnitude and distance of the power transmitted to the reception unit. A constant power can be maintained in a wide range through the phase control of different output powers according to the positions of the transmitting and receiving coils. A constant power can also be obtained by transmitting to the receiver. The experiment results show that the proposed method outperforms the conventional method.

오류 역전파 알고리즘을 이용한 자기 공명 영상 자동 세그멘테이션 (Automatic segmentation of magnetic resonance images using error back-propagation algorithm)

  • 최재호;조범준
    • 한국통신학회논문지
    • /
    • 제22권11호
    • /
    • pp.2425-2431
    • /
    • 1997
  • 자기 공명 영상의 사용이 빈번해 짐에 따라 환자의 해부학적인 정확한 정보와 이를 빠르고 효과적으로 진단하는데 유용한 자동 영상 세그멘테이션 방법이 요구되고 있다. 본 논문에서는 오류 역전파 알고리즘으로 학습한 신경망을 이용하여 뇌의 자기 공명 영상을 자동적으로 세그멘테이션하는 방법을 제안한다. 특정 환자의 자기 공명 영상을 분할하여 학습시킨 신경망은 다른 환자의 자기 공명 영상도 자동적으로 세그멘테이션하여 뇌의 윤곽을 뚜렷하게 나타내었다.

  • PDF

공진과 반공진 특성을 동시고려한 모델 축소 (Model Reduction Considering Both Resonances and Antiresonances)

  • 허진석;이시복;이창일
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 춘계학술대회논문집
    • /
    • pp.985-990
    • /
    • 2001
  • The Frequency Response Function(FRF)s of FE Model reduced by SEREP methods accurately estimate the full model at resonance frequencies, However these FRFs are not accurate at antiresonance frequencies, Additionally, the truncation errors may he significant in the reduction mode1. So this paper considers the possibility of SERFP method through a numerical method to preserve dynamic behavior at antiresonance and appliers the static or dynamic compensation methods for truncation errors to the reduction model. This compensated reduction model is redesigned for pole-zero cancellation methods the objective of reducing a resonance frequency.

  • PDF